Your browser doesn't support javascript.
loading
Optimization of b-value distribution for four mathematical models of prostate cancer diffusion-weighted imaging using b values up to 2000 s/mm(2): simulation and repeatability study.
Merisaari, Harri; Jambor, Ivan.
Afiliação
  • Merisaari H; Department of Information Technology, University of Turku, Turku, Finland; Turku PET Centre, University of Turku, Turku, Finland.
Magn Reson Med ; 73(5): 1954-69, 2015 May.
Article em En | MEDLINE | ID: mdl-25045885
ABSTRACT

PURPOSE:

To find optimal b-value distributions for monoexponential, stretched exponential, kurtosis, and biexponential models of prostate cancer (PCa) diffusion-weighted imaging (DWI) using simulations and repeated DWI examinations.

METHODS:

Simulations aiming to minimize estimation accuracy error were performed. Ten PCa patients underwent in total four repeated 3-tesla DWI examinations using 12 equally spaced b values (0-2000 s/mm(2) ). Normalized mean signal intensities of regions-of-interest placed in normal tissue and PCa were fitted. In total, 210 different b-value combinations consisting of six b values, 0 and 100 s/mm(2) included in every b-value distribution, were evaluated in terms of accuracy and repeatability.

RESULTS:

The simulations and in vivo DWI data suggest the optimal b-value distribution for the monoexponential model consists of four to five equally distributed b values in the range of 0 to 1200 s/mm(2) . The parameters of the stretched exponential and kurtosis models are best estimated using five to seven b values in the ranges of 300 to 700 and close to 2000 s/mm(2) , in addition to low b value. B-value distribution consisting of eight to 10 b values in the ranges of 0 to 100, 800 to 1200, and 1800 to 2000 s/mm(2) is the preferred method for estimation of the biexponential model parameters of PCa DWI.

CONCLUSION:

The optimized b-value distributions demonstrated improved estimation accuracy and repeatability of DWI signal decay-derived parameters.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Próstata / Neoplasias da Próstata / Interpretação de Imagem Assistida por Computador / Imagens de Fantasmas / Imagem de Difusão por Ressonância Magnética / Modelos Teóricos Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Finlândia

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Próstata / Neoplasias da Próstata / Interpretação de Imagem Assistida por Computador / Imagens de Fantasmas / Imagem de Difusão por Ressonância Magnética / Modelos Teóricos Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Finlândia