Microdosimetry in 3D realistic mitochondria phantoms: Geant4 Monte Carlo tracking of 250keV photons in phantoms reconstructed from microscopic images.
Zein, S; Francis, Z; Montarou, G; Chandez, F; Kane, M S; Chevrollier, A.
Afiliação
  • Zein S; Saint Joseph University, Faculty of Sciences, Department of Physics, Beirut, Lebanon; Laboratoire de Physique de Clermont (Particules, pLasmas, Univers, applicationS), Université Clermont Auvergne, CNRS/IN2P3, F-63000 Clermont-Ferrand, France. Electronic address: sara.zein@clermont.in2p3.fr.
  • Francis Z; Saint Joseph University, Faculty of Sciences, Department of Physics, Beirut, Lebanon.
  • Montarou G; Laboratoire de Physique de Clermont (Particules, pLasmas, Univers, applicationS), Université Clermont Auvergne, CNRS/IN2P3, F-63000 Clermont-Ferrand, France.
  • Chandez F; Laboratoire de Physique de Clermont (Particules, pLasmas, Univers, applicationS), Université Clermont Auvergne, CNRS/IN2P3, F-63000 Clermont-Ferrand, France.
  • Kane MS; PREMMi/Mitochondrial Medicine Research Centre, Institut MITOVASC, CNRS UMR 6015, INSERM U1083, Université d'Angers, CHU d'Angers, Angers, France.
  • Chevrollier A; PREMMi/Mitochondrial Medicine Research Centre, Institut MITOVASC, CNRS UMR 6015, INSERM U1083, Université d'Angers, CHU d'Angers, Angers, France.
Phys Med ; 42: 7-12, 2017 Oct.
Article em En | MEDLINE | ID: mdl-29173923
Mitochondria are considered to be sensitive radiation targets since they control processes vital to the cell's functioning. These organelles are starting to get attention and some studies are investigating the radiation dose inside them. In previous studies, mitochondria are represented as simple ellipsoids inside the cell not taking into consideration the complexity of their shape. In this study, realistic phantoms are built based on deconvolved widefield fluorescent microscopic images of the mitochondrial networks of fibroblast cells. The phantoms are imported into Geant4 as tessellated volumes taking into account the geometrical complexity of these organelles. Irradiation with 250keV photons is performed and the lineal energy is calculated. The lineal energy distributions inside the produced phantoms are compared with those calculated inside simple volumes, a sphere and an ellipsoid, where the effect of the shape and volume is clearly seen on lineal energies.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Radiometria / Fótons / Imagens de Fantasmas / Imageamento Tridimensional / Mitocôndrias Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Radiometria / Fótons / Imagens de Fantasmas / Imageamento Tridimensional / Mitocôndrias Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2017 Tipo de documento: Article