Fast and sensitive diagnosis of autoimmune disorders through amperometric biosensing of serum anti-dsDNA autoantibodies.
Arévalo, Beatriz; Serafín, Verónica; Sánchez-Paniagua, Marta; Montero-Calle, Ana; Barderas, Rodrigo; López-Ruíz, Beatriz; Campuzano, Susana; Yáñez-Sedeño, Paloma; Pingarrón, José M.
Afiliação
  • Arévalo B; Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria S/N, 28040, Madrid, Spain.
  • Serafín V; Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria S/N, 28040, Madrid, Spain.
  • Sánchez-Paniagua M; Department of Chemistry in Pharmaceutical Sciences, Faculty of Pharmacy, University Complutense of Madrid, Ciudad Universitaria S/N, 28040, Madrid, Spain.
  • Montero-Calle A; Chronic Disease Progamme, UFIEC, Institute de Salud Carlos III, 28220, Majadahonda, Madrid, Spain.
  • Barderas R; Chronic Disease Progamme, UFIEC, Institute de Salud Carlos III, 28220, Majadahonda, Madrid, Spain.
  • López-Ruíz B; Department of Chemistry in Pharmaceutical Sciences, Faculty of Pharmacy, University Complutense of Madrid, Ciudad Universitaria S/N, 28040, Madrid, Spain.
  • Campuzano S; Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria S/N, 28040, Madrid, Spain. Electronic address: susanacr@ucm.es.
  • Yáñez-Sedeño P; Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria S/N, 28040, Madrid, Spain. Electronic address: yseo@quim.ucm.es.
  • Pingarrón JM; Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria S/N, 28040, Madrid, Spain.
Biosens Bioelectron ; 160: 112233, 2020 Jul 15.
Article em En | MEDLINE | ID: mdl-32469729
This work reports the first amperometric biosensor involving the use of neutravidin-functionalized magnetic microbeads (NA-MBs) modified with a biotinylated-anti-dsDNA (b-dsDNA) as efficient magnetic microcarriers to selectively capture anti-dsDNA autoantibodies (IgG, IgA and IgM AAbs) present in the sera of patients with rheumatoid arthritis (RA). Subsequently, the attached anti-dsDNA AAbs are detected with a mixture of conventional HRP-labeled secondary antibodies (HRP-anti-human IgG/IgM/IgA mixture). The biorecognition event is monitored by amperometric transduction using the hydroquinone (HQ)/H2O2 system upon capturing the modified MBs on the surface of screen-printed carbon electrodes (SPCEs). The developed bioplatform exhibits a linear calibration plot ranging from 1 to 200 IU mL-1 with a LOD of 0.3 IU mL-1 for anti-dsDNA AAbs standards. In addition, the biosensor allows performing the determination of the anti-dsDNA AAbs levels directly in 100-times diluted serum samples from patients diagnosed with RA and in just 75 min. The obtained results are in agreement with those provided by an ELISA kit and allow discrimination between positive and negative samples.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Artrite Reumatoide / Autoanticorpos / DNA Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Artrite Reumatoide / Autoanticorpos / DNA Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Espanha