Your browser doesn't support javascript.
loading
Quantitative assessment of temporal skin elasticity using shear wave elastography in pediatric cochlear implant users.
Yildiz, Muhammet; Ozkan, Mehmet Burak; Selcuk, Omer Tarik; Cetinkaya, Erdem Atalay; Ensari, Nuray; Yilmaz, Nevreste Didem Sonbay; Gur, Ozer Erdem.
Afiliação
  • Yildiz M; Department of Otorhinolaryngology-Head and Neck Surgery, Antalya Training and Research Hospital, Antalya, Turkey. Electronic address: dr_yildiz_muhammet@hotmail.com.
  • Ozkan MB; Department of Pediatric Radiology, Antalya Training and Research Hospital, Antalya, Turkey.
  • Selcuk OT; Department of Otorhinolaryngology-Head and Neck Surgery, Antalya Training and Research Hospital, Antalya, Turkey.
  • Cetinkaya EA; Department of Otorhinolaryngology-Head and Neck Surgery, Antalya Training and Research Hospital, Antalya, Turkey.
  • Ensari N; Department of Otorhinolaryngology-Head and Neck Surgery, Antalya Training and Research Hospital, Antalya, Turkey.
  • Yilmaz NDS; Department of Otorhinolaryngology-Head and Neck Surgery, Antalya Training and Research Hospital, Antalya, Turkey.
  • Gur OE; Department of Otorhinolaryngology-Head and Neck Surgery, Antalya Training and Research Hospital, Antalya, Turkey.
Int J Pediatr Otorhinolaryngol ; 137: 110257, 2020 Oct.
Article em En | MEDLINE | ID: mdl-32896336
ABSTRACT

OBJECTIVE:

To evaluate temporal skin thicknesses and stiffness values using shear wave elastography (SWE) in asymptomatic pediatric patients who underwent cochlear implantation. SUBJECTS AND

METHODS:

Sixty-four deafened pediatric patients with unilateral cochlear implant (CI) who had no complications were enrolled. The age, sex, weight, height, body mass index (BMI), CI side, duration of CI use and CI device brand of all participants were noted. Temporal skin thickness and stiffness values were measured from implanted and contralateral unimplanted sides using SWE.

RESULTS:

The mean skin thickness measurements of implanted and unimplanted sides were 11.87 ± 3.42 and 5.34 ± 1.56 mm, respectively. The mean skin stiffness measurements of implanted and unimplanted sides were 3.08 ± 0.7 and 1.29 ± 0.26 m/s, respectively. There were statistically significant differences in skin thickness and stiffness between implanted and unimplanted sides (P < .001, P < .001). The mean skin thickness and stiffness measurements did not differ among types of CI devices (P = .948, P = .362). Age had positive correlation with implanted (P < .001, P = .019) and unimplanted sides (P < .001, P < .001) skin thickness and stiffness. BMI had positive correlation with implanted (P < .001, P = .023) and unimplanted sides (P < .001, P < .001) skin thickness and stiffness. Duration of CI use had positive correlation with implanted side skin thickness (P < .001) and stiffness (P = .031).

CONCLUSION:

Temporal skin thickness and stiffness increase after CI surgery. SWE has the potential to improve diagnostic accuracy, and our results may provide important data for evaluation of clinical entities that affect temporal skin structures.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Pele / Dermatopatias / Implantes Cocleares / Implante Coclear / Técnicas de Imagem por Elasticidade / Perda Auditiva Neurossensorial Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En Revista: Int J Pediatr Otorhinolaryngol Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Pele / Dermatopatias / Implantes Cocleares / Implante Coclear / Técnicas de Imagem por Elasticidade / Perda Auditiva Neurossensorial Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En Revista: Int J Pediatr Otorhinolaryngol Ano de publicação: 2020 Tipo de documento: Article