Computational Analysis of Virtual Echocardiographic Assessment of Functional Mitral Regurgitation for Validation of Proximal Isovelocity Surface Area Methods.
Qin, Tongran; Caballero, Andrés; Hahn, Rebecca T; McKay, Raymond; Sun, Wei.
Afiliação
  • Qin T; Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
  • Caballero A; Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia; PAI+ Research Group, Energetics and Mechanics Department, Universidad Autónoma de Occidente, Cali, Colombia.
  • Hahn RT; Division of Cardiology, Columbia University Medical Center, New York, New York.
  • McKay R; Cardiology Department, The Hartford Hospital, Hartford, Connecticut.
  • Sun W; Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia. Electronic address: wei.sun@bme.gatech.edu.
J Am Soc Echocardiogr ; 34(11): 1211-1223, 2021 11.
Article em En | MEDLINE | ID: mdl-34214636
ABSTRACT

BACKGROUND:

Mitral regurgitation (MR) quantification by the proximal isovelocity surface area (PISA) method remains challenging. Using computer models, the authors evaluated the accuracy of different PISA methods and quantified their errors.

METHODS:

Five functional MR computer models of different geometric and tethering abnormalities were created, validated, and treated as phantom models, from which the reference values were directly obtained. Virtual two-dimensional (2D) PISA and three-dimensional (3D) PISA (both peak and integrated values) were performed on these phantom models. By comparing virtual PISA results with reference values, the accuracy of different PISA methods was evaluated, and their sources of errors were quantified.

RESULTS:

Compared with reference values of regurgitant flow rate, excellent correlations were found for true PISA (r = 0.99, bias = 32.3 ± 35.3 mL/sec), 3D PISA (r = 0.97, bias = -24.4 ± 55.5 mL/sec), followed by multiplane 2D hemicylindrical PISA (r = 0.88, bias = -24.1 ± 85.4 mL/sec) and hemiellipsoidal PISA (r = 0.91, bias = -55.7 ± 96.6 mL/sec). Weaker correlations were found for single-plane 2D hemispherical PISA (parasternal long-axis r = 0.71, bias = -77.6 ± 124.5 mL/sec; apical two-chamber r = 0.69, bias = -52.0 ± 122.0 mL/sec; apical four-chamber r = 0.82, bias = -65.5 ± 107.3 mL/sec). For regurgitant volume quantification, integrated PISA was more accurate than peak PISA. The bias of 3D PISA improved from -12.7 ± 7.8 mL (peak PISA) to -2.1 ± 5.3 mL (integrated PISA).

CONCLUSIONS:

For functional MR quantification, 2D hemispherical PISA had significant underestimation, multiplane 2D hemiellipsoidal and hemicylindrical PISA showed improved accuracy, and 3D PISA was the most accurate. The PISA method is subject to both systematic underestimation due to the Doppler angle effect and systematic overestimation when regurgitant flow is not perpendicular to PISA contour. Integrated PISA is able to capture dynamic MR and is therefore more accurate than peak PISA. The sum of regurgitant flow rates is the most feasible way to perform integrated PISA.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Ecocardiografia Tridimensional / Insuficiência da Valva Mitral Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Geórgia

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Ecocardiografia Tridimensional / Insuficiência da Valva Mitral Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Geórgia