The assessment of effectiveness, tolerance, and patient satisfaction with the use of a new fixed-dose combination product, containing salmeterol and fluticasone propionate, Salflumix Easyhaler® in the treatment of asthma in the daily clinical practice.
Doniec, Zbigniew; Olszanecka-Glinianowicz, Magdalena; Hantulik, Piotr; Almgren-Rachtan, Agnieszka; Chudek, Jerzy.
Afiliação
  • Doniec Z; Department of Pneumonology, Institute of Tuberculosis and Lung Diseases, Rabka-Zdrój, Poland.
  • Olszanecka-Glinianowicz M; Health Promotion and Obesity Management Unit, Department of Pathophysiology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, Katowice, Poland.
  • Hantulik P; Orion Pharma Poland Co. Ltd, Warszawa, Poland.
  • Almgren-Rachtan A; Euromedic Medical Centre, Katowice, Poland.
  • Chudek J; Pathophysiology Unit, Department of Internal Diseases and Oncological Chemotherapy, Faculty of Medical Sciences in Katowice, Medical University of Silesia, Katowice, Poland.
J Asthma ; 60(4): 754-760, 2023 04.
Article em En | MEDLINE | ID: mdl-35730239
ABSTRACT

BACKGROUND:

The effectiveness of a fix-dose salmeterol/fluticasone combination therapy in asthma was previously shown for the original product. The study aim was to evaluate the clinical effectiveness and safety of a second entry DPI - dry powder inhaler (Salflumix Easyhaler) in patients with asthma in everyday clinical practice. PATIENTS AND

METHODS:

This multicenter Investigator-Initiated Study that enrolled 2,037 adult outpatients with asthma treated with Salflumix Easyhaler, was conducted by 220 pulmonologists across Poland. Asthma control was assessed during 3 visits with 6 ± 2 weeks intervals based on the Asthma Control Test (ACT). In addition, patient Satisfaction with Asthma Treatment Questionnaire (SATQ) and adherence and adverse events (AEs) were monitored.

RESULTS:

During the observation (86 ± 30 days) the percentage of patients with controlled asthma (ACT 20-25 pts) increased from 35.5% at the first visit to 86.5% at the third visit (p < 0.001). In the subgroup analysis, there were more patients not obtaining asthma control among patients that switched from the treatment with other devices than in naive ones. Global SATQ scores increased from 5.8 ± 0.7 to 6.2 ± 0.6 during the observation. Patients' satisfaction with the use of the Salflumix Easyhaler was high. Adherence exceeded 95%. Eight AEs were reported.

CONCLUSIONS:

Salflumix Easyhaler is highly effective and well-tolerated by naïve patients with asthma and those switching from another device. In general, patients show good compliance with medical product and are satisfied with the use of this new device, and not reporting difficulties and errors related to its' use. Their physicians' overall perception of Salflumix Easyhaler use is very positive.