Your browser doesn't support javascript.
loading
Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population.
Orii, Makoto; Sone, Misato; Osaki, Takeshi; Kikuchi, Kei; Sugawara, Tsuyoshi; Zhu, Xucheng; Janich, Martin A; Nozaki, Atsushi; Yoshioka, Kunihiro.
Afiliação
  • Orii M; Department of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan. kori931@gmail.com.
  • Sone M; Department of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan.
  • Osaki T; Department of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan.
  • Kikuchi K; Department of Radiology Service, Iwate Medical University, Iwate, Japan.
  • Sugawara T; Department of Radiology Service, Iwate Medical University, Iwate, Japan.
  • Zhu X; GE Healthcare, Menlo Park, CA, USA.
  • Janich MA; GE Healthcare, Munich, Germany.
  • Nozaki A; GE Healthcare, Tokyo, Japan.
  • Yoshioka K; Department of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan.
Int J Cardiovasc Imaging ; 39(5): 1001-1011, 2023 May.
Article em En | MEDLINE | ID: mdl-36648573
ABSTRACT
This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Aprendizado Profundo Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Aprendizado Profundo Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão