Your browser doesn't support javascript.
loading
Microstructure-Driven Self-Transport and Convection of Water on Membrane Surface for Ultra-Fast, Highly Sensitive, Low-Cost Lateral-Flow Assays.
Liu, Yiren; Li, Juanhua; Xiao, Zihan; Wu, Tianyu; Zhou, Cuiping; Zhou, Jianhua.
Afiliação
  • Liu Y; School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China.
  • Li J; Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, 510275, China.
  • Xiao Z; School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China.
  • Wu T; Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, 510275, China.
  • Zhou C; School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China.
  • Zhou J; School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China.
Small ; 20(21): e2309956, 2024 May.
Article em En | MEDLINE | ID: mdl-38145329
ABSTRACT
Lateral-flow assay (LFA) is one of the most commonly used detection technologies, in which the chromatographic membranes are currently used as the lateral-flow membrane (e.g., nitrocellulose membrane, NC Mem). However, several disadvantages of existing chromatographic membranes limit the performance of LFA, including relatively low flow velocity of sample solution and relatively more residuals of sample on membrane, which increase detection time and detection noise. Herein, a surface structure membrane (SS Mem) is proposed, which enables fast self-transport of water with a convection manner and realizes low residuals of sample on membrane surface after the flow. On SS Mem, the flow velocity of water is 7.1-fold higher, and the residuals of sample are decreased by 60-67%, comparing those in NC Mem. SS Mem is used as lateral-flow membrane to prepare lateral-flow strips of nanogold LFA and fluorescence LFA for rapid detection of SARS CoV-2 nucleocapsid protein. These LFAs require 210 s per detection, with limits of detection of 3.98 pg mL-1 and 53.3 fg mL-1, sensitivity of 96.5%, and specificity of 90%. The results suggest that SS Mem enables ultrafast, highly sensitive lateral-flow immunoassays and shows great potential as a new type of lateral-flow membrane to broaden the application of LFA.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Água / SARS-CoV-2 Limite: Humans Idioma: En Revista: Small Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Água / SARS-CoV-2 Limite: Humans Idioma: En Revista: Small Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China