Your browser doesn't support javascript.
loading
Health risk assessment from inhalation exposure to indoor formaldehyde: A systematic review and meta-analysis.
Khoshakhlagh, Amir Hossein; Mohammadzadeh, Mahdiyeh; Ghobakhloo, Safiye; Cheng, Hefa; Gruszecka-Kosowska, Agnieszka; Knight, Jasper.
Afiliação
  • Khoshakhlagh AH; Department of Occupational Health Engineering, School of Health, Kashan University of Medical Sciences, Kashan, Iran.
  • Mohammadzadeh M; Department of Health in Emergencies and Disasters, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran. Electronic address: m.mohammadzadeh997@gmail.com.
  • Ghobakhloo S; Department of Environmental Health Engineering, School of Health, Kashan University of Medical Sciences, Kashan, Iran.
  • Cheng H; MOE Key Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871, China.
  • Gruszecka-Kosowska A; AGH University of Krakow, Faculty of Geology, Geophysics, and Environmental Protection, Department of Environmental Protection, Al. Mickiewicza 30, 30-059, Krakow, Poland.
  • Knight J; School of Geography, Archaeology & Environmental Studies, University of the Witwatersrand, Johannesburg 2050, South Africa.
J Hazard Mater ; 471: 134307, 2024 Jun 05.
Article em En | MEDLINE | ID: mdl-38678702
ABSTRACT
This systematic review and meta-analysis investigated studies on formaldehyde (FA) inhalation exposure in indoor environments and related carcinogenic (CR) and non-carcinogenic (HQ) risk. Studies were obtained from Scopus, PubMed, Web of Science, Medline, and Embase databases without time limitation until November 21, 2023. Studies not meeting the criteria of Population, Exposure, Comparator, and Outcomes (PECO) were excluded. The 45 articles included belonged to the 5 types of sites dwelling environments, educational centers, kindergartens, vehicle cabins, and other indoor environments. A meta-analysis determined the average effect size (ES) between indoor FA concentrations, CR, and HQ values in each type of indoor environment. FA concentrations ranged from 0.01 to 1620 µg/m3. The highest FA concentrations were stated in water pipe cafés and the lowest in residential environments. In more than 90% of the studies uncertain (1.00 ×10-6 risk (CR>1.00 ×10-4) due to FA inhalation exposure was reported and non-carcinogenic risk was stated acceptable. The meta-analysis revealed the highest CR values due to inhalation of indoor FA in high-income countries. As 90% of the time is spent indoors, it is crucial to adopt effective strategies to reduce FA concentrations, especially in kindergartens and schools, with regular monitoring of indoor air quality.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Exposição por Inalação / Formaldeído Limite: Humans Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Exposição por Inalação / Formaldeído Limite: Humans Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã