Your browser doesn't support javascript.
loading
Pharmacokinetic assessment of low dose decitabine in combination therapies: Development and validation of a sensitive UHPLC-MS/MS method for murine plasma analysis.
Anabtawi, Nadeen; Drabison, Thomas; Jin, Yan; Eisenmann, Eric D; Sparreboom, Alex; Govindarajan, Rajgopal; Baker, Sharyn D; Ahmed, Eman.
Afiliação
  • Anabtawi N; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Drabison T; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Jin Y; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Eisenmann ED; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Sparreboom A; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Govindarajan R; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Baker SD; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA. Electronic address: baker.2480@osu.edu.
  • Ahmed E; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
Article em En | MEDLINE | ID: mdl-38905720
ABSTRACT
Decitabine is a DNA methyltransferase inhibitor used in the treatment of acute myeloid leukemia and myelodysplastic syndrome. The notion that ongoing trials are presently exploring the combined use of decitabine, with or without the cytidine deaminase inhibitor cedazuridine, and other antileukemic drugs necessitates a comprehensive understanding of pharmacokinetic properties and an evaluation of drug-drug interaction liabilities. We report here the development and validation of a sensitive UHPLC-MS/MS method for quantifying decitabine in mouse plasma, which should be useful for such studies. The method involved a one-step protein precipitation extraction, and chromatographic separation on an XBridge HILIC column using gradient elution. The method was found to be robust, accurate, precise, and sufficiently sensitive (lower limit of quantitation, 0.4 ng/mL) to determine decitabine concentrations in microvolumes of plasma from mice receiving the agent orally or intravenously in the presence or absence of cedazuridine.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Decitabina Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Decitabina Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos