Your browser doesn't support javascript.
loading
Batch Fabrication of Flexible Strain Sensors with High Linearity and Low Hysteresis for Health Monitoring and Motion Detection.
Liu, Boyang; Lan, Binxu; Shi, Liangjing; Cheng, Yin; Sun, Jing; Wang, Ranran.
Afiliação
  • Liu B; State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, China.
  • Lan B; School of Chemistry and Materials Science, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, 1 Sub-Lane Xiangshan, Hangzhou 310024, China.
  • Shi L; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing 100049, China.
  • Cheng Y; State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, China.
  • Sun J; State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, China.
  • Wang R; State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, China.
ACS Appl Mater Interfaces ; 16(28): 36821-36831, 2024 Jul 17.
Article em En | MEDLINE | ID: mdl-38953185
ABSTRACT
In recent years, flexible strain sensors have gradually come into our lives due to their superiority in the field of biomonitoring. However, these sensors still suffer from poor durability, high hysteresis, and difficulty in calibration, resulting in great hindrance of practical application. Herein, starting with interfacial interaction regulation and structure-induced cracking, flexible strain sensors with high performance are successfully fabricated. In this strategy, dopamine treatment is used to enhance the bonding between flexible substrates and carbon nanotubes (CNT). The combination within the conductive networks is then controlled by substituting the CNT type. Braid-like fibers are employed to achieve controllable expansion of the conductive layer cracks. Finally, we obtain strain sensors that possess high linearity (R2 = 0.997) with low hysteresis (5%), high sensitivity (GF = 60) and wide sensing range (0-50%), short response time (62 ms), outstanding stability, and repeatability (>10,000 cycles). Flexible strain sensors with all performances good are rarely reported. Static and dynamic respiration and pulse signal monitoring by the fiber sensor are demonstrated. Moreover, a knee joint monitoring system is constructed for the monitoring of various walking stances, which is of great value to the diagnosis and rehabilitation of many diseases.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Estado_mercado_regulacao Bases de dados: MEDLINE Assunto principal: Nanotubos de Carbono Limite: Humans Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Temas: ECOS / Estado_mercado_regulacao Bases de dados: MEDLINE Assunto principal: Nanotubos de Carbono Limite: Humans Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China