ABSTRACT
Granulated Activated Carbon (GAC) filtration is a common process for advanced wastewater treatment. In such filters, the removal of organic substances results from adsorptive as well as biological processes. This work investigated the potential of biological processes and their influence on GAC-filter performance. During 32 months, the removal of micropollutants,Dissolved Organic Carbon (DOC) and the spectral absorption coefficient was monitored in six GAC-filters. The effects of pre-treatment (cloth- and/or membrane-filtration), EBCT (from 6 - 35 min) and GAC-type were evaluated. Likewise, the impact of the influent´s fluctuations in temperature, flow and concentration (ammonia, nitrate, and soluble reactive phosphorus (sRP)) were analysed. Biological processes were tracked by the frequency of backwashing, oxygen consumption, removal of poorly absorbable micropollutants and production of transformation products. Pre-treatment influenced biofilm growth significantly. Membrane filtration delayed the first backwashing event by 122 d in comparison to cloth-filtration, where the first backwash was conducted after only 21 d. Removal of poorly absorbable substances was observed early on (40 - 50 d). Parallel operation contributed to a better utilisation of the GAC-capacity and the biological removal potential. Influent nitrogen species > 0.5 mg N/L promoted biofilm growth, whereas sRP seemed to have no effect. The developed biofilm and optimal operating conditions led to longer life spans of the GAC-filters, making carbon usage rates comparable to those from PAC applications. The results suggest that biological processes accounted for about 25 - 42% of the totally removed DOC at the end of the operation.
Subject(s)
Water Pollutants, Chemical , Water Purification , Charcoal , Filtration , Wastewater , Water Pollutants, Chemical/analysisABSTRACT
The removal of micropollutants from wastewater is an emerging issue that currently concerns the wastewater sector the most. Granular Activated Carbon (GAC) has gained recognition as a suitable technology for dealing with this problem. This study assesses the performance of six GAC-filters for the removal of micropollutants installed as final treatment step at a municipal wastewater treatment plant. The influence of the GAC-type and the Empty Bed Contact Time (EBCT) on the filter performance was evaluated. The breakthrough behaviour of 13 selected micropollutants as well as the removal of the Dissolved Organic Carbon (DOC) and UV absorption at 254 nm were investigated. Besides, the adsorbed DOC (qDOC) was introduced as assessment parameter (adsorbed and biodegraded DOC), instead of the commonly used treated bed volume. Finally, Size Exclusion Chromatography (SEC) with online DOC and UV254nm detection was applied for a better understanding of the influent and effluent characteristics. The results showed that the pore size distribution is a crucial feature of the activated carbon. A balanced proportion of macro-, meso and micropores may play a role in the better removal of micropollutants in presence of DOC. Regardless of the GAC-type, a minimum EBCT between 20 - 30 min was necessary. We proved that a short EBCT would not fully use the sorption capacity, whereas a long EBCT would increase the carbon demand without improving of the removal. Lastly, according to the SEC results, after a short operation time no difference between the influent and effluent chromatographable fractions (DOC and UV254nm) was observed.