Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Pharm Nanotechnol ; 10(2): 90-112, 2022.
Article in English | MEDLINE | ID: mdl-35142274

ABSTRACT

According to the interaction of nanoparticles with biological systems, enthusiasm for nanotechnology in biomedical applications has been developed in the past decades. Fe2O3 nanoparticles, as the most stable iron oxide, have special merits that make them useful widely for detecting diseases, therapy, drug delivery, and monitoring the therapeutic process. This review presents the fabrication methods of Fe2O3-based materials and their photocatalytic and magnetic properties. Then, we highlight the application of Fe2O3-based nanoparticles in diagnosis and imaging, different therapy methods, and finally, stimulus-responsive systems, such as pH-responsive, magneticresponsive, redox-responsive, and enzyme-responsive, with an emphasis on cancer treatment. In addition, the potential of Fe2O3 to combine diagnosis and therapy within a single particle called theranostic agent will be discussed.


Subject(s)
Drug Delivery Systems , Nanoparticles , Drug Delivery Systems/methods , Precision Medicine
2.
Sci Rep ; 7(1): 11437, 2017 09 12.
Article in English | MEDLINE | ID: mdl-28900202

ABSTRACT

In this paper we designed and fabricated a metasurface working as a radar cross section (RCS) reducer over an ultra wide band of frequency from 3.8 to 10.7 GHz. The designed metasurface is a chessboard-like surface made of alternating tiles, with each tile composed of identical unit cells. We develop a novel, simple, highly robust and fully automated approach for designing the unit cells. First, a topology optimization algorithm is used to engineer the shape of the two unit cells. The area of each unit cell is pixelated. A particle swarm optimization algorithm is applied wherein each pixel corresponds to a bit having a binary value of 1 or 0 indicating metallization or no metallization. With the objective of reducing the RCS over a specified frequency range, the optimization algorithm is then linked to a full wave three-dimensional electromagnetic simulator. To validate the design procedure, a surface was designed, fabricated and experimentally tested showing significantly enhanced performance than previous works. Additionally, angular analysis is also presented showing good stability and wide-angle behavior of the designed RCS reducer. The automated design procedure has a wide range of applications and can be easily extended to design surfaces for antennas, energy harvesters, noise mitigation in electronic circuit boards amongst others.

3.
Adv Biomed Res ; 4: 54, 2015.
Article in English | MEDLINE | ID: mdl-25802823

ABSTRACT

BACKGROUND: The pulsatility index (PI), measured by transcranial Doppler (TCD) ultrasonography, can reflect vascular resistance induced by cerebral small-vessel disease (SVD). We evaluated the value of TCD-derived PI for diagnosing SVD as compared with magnetic resonance imaging (MRI). MATERIALS AND METHODS: Fifty-six consecutive cases with SVD (based on MRI) and 48 controls with normal MRI underwent TCD. Based on MRI findings, patients were categorized into five subgroups of preventricular hyperintensity (PVH), deep white matter hyperintensity (DWMH), lacunar, pontin hyperintensity (PH), and PVH+DWMH+lacunar. The sensitivity and specificity of TCD in best PI cut-off points were calculated in each group. RESULTS: The sensitivity and specificity of TCD in comparison with MRI with best PI cut-off points were as follows: In PVH with PI = 0.83, the sensitivity and specificity was 90% and 98%, respectively. In DWMH with PI = 0.79, the sensitivity and specificity was 75% and 87.5%, respectively. In lacunar with PI = 0.80, the sensitivity and specificity was 73% and 90%, respectively. In PH with PI = 0.69, the sensitivity and specificity was 92% and 87.5%, respectively. And, in PVH+DWMH+lacunar subgroup with PI = 0.83, the sensitivity and specificity was 90% and 96%, respectively. CONCLUSIONS: Increased TCD derived PI can accurately indicate the SVD. Hence, TCD can be used as a non-invasive and inexpensive method for diagnosing SVD, and TCD-derived PI can be considered as a physiologic index of the disease as well.

SELECTION OF CITATIONS
SEARCH DETAIL