Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Opt Express ; 31(21): 35225-35244, 2023 Oct 09.
Article in English | MEDLINE | ID: mdl-37859259

ABSTRACT

We report a resonant cavity infrared detector (RCID) with an InAsSb/InAs superlattice absorber with a thickness of only ≈ 100 nm, a 33-period GaAs/Al0.92Ga0.08As distributed Bragg reflector bottom mirror, and a Ge/SiO2/Ge top mirror. At a low bias voltage of 150 mV, the external quantum efficiency (EQE) reaches 58% at the resonance wavelength λres ≈ 4.6 µm, with linewidth δλ = 19-27 nm. The thermal background current for a realistic system scenario with f/4 optic that views a 300 K scene is estimated by integrating the photocurrent generated by background spanning the entire mid-IR spectral band (3-5 µm). The resulting specific detectivity is a factor of 3 lower than for a state-of-the-art broadband HgCdTe device at 300 K, where dark current dominates the noise. However, at 125 K where the suppression of background noise becomes critical, the estimated specific detectivity D* of 5.5 × 1012 cm Hz½/W is more than 3× higher. This occurs despite a non-optimal absorber cut-off that causes the EQE to decrease rapidly with decreasing temperature, e.g., to 33% at 125 K. The present RCID's advantage over the broadband device depends critically on its low EQE at non-resonance wavelengths: ≤ 1% in the range 3.9-5.5 µm. Simulations using NRL MULTIBANDS indicate that impact ionization in the bottom contact and absorber layers dominates the dark current at near ambient temperatures. We expect future design modifications to substantially enhance D* throughout the investigated temperature range of 100-300 K.

2.
Opt Express ; 27(3): 3771-3781, 2019 Feb 04.
Article in English | MEDLINE | ID: mdl-30732391

ABSTRACT

We report resonant-cavity infrared detectors with 34% external quantum efficiency at room temperature at the resonant wavelength of 4.0 µm, even though the absorber consists of only five quantum wells with a total thickness of 50 nm. The full width at half maximum (FWHM) linewidth is 46 nm, and the peak absorption is enhanced by nearly a factor of 30 over that for a single pass through the absorber. In spite of an unfavorable Shockley-Read lifetime in the current material, the dark current density is at the level of state-of-the-art HgCdTe detectors as quantified by "Rule 07." The Johnson-noise limited detectivity (D*) at 21°C is 7 × 109 cm Hz½/W. We expect that future improvements in the device design and material quality will lead to higher quantum efficiency, as well as a significant reduction of the dark current density consistent with the very thin absorber.

3.
ACS Appl Mater Interfaces ; 13(49): 58916-58926, 2021 Dec 15.
Article in English | MEDLINE | ID: mdl-34870961

ABSTRACT

Improved passivation strategies to address the more complex surface structure of large-diameter nanocrystals are critical to the advancement of infrared photodetectors based on colloidal PbS. In this contribution, the performance of short-wave infrared (SWIR) photodiodes fabricated with PbS/PbClx (core/shell) nanocrystals vs their PbS-only (core) counterparts are directly compared. Devices using PbS cores suffer from shunting and inefficient charge extraction, while core/shell-based devices exhibit greater external quantum efficiencies and lower dark current densities. To elucidate the implications of the shell chemistry on device performance, thickness-dependent energy level offsets and interfacial chemistry of nanocrystal films with the zinc oxide electron-transport layer are evaluated. The disparate device performance between the two synthetic methods is attributed to unfavorable interface dipole formation and surface defect states, associated with inadequate removal of native organic ligands in core-only films. The core/shell system offers a promising route to manage the additional nonpolar (100) surface facets of larger nanocrystals that conventional halide ligand treatments fail to sufficiently passivate.

SELECTION OF CITATIONS
SEARCH DETAIL