Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 263
Filter
Add more filters

Publication year range
1.
Circ J ; 88(7): 1147-1154, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38311419

ABSTRACT

BACKGROUND: High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs.Methods and Results: The amount of adipose tissue adjacent to the device and anteroposterior diameter at the basal heart region were measured preoperatively using chest CT. We examined the correlation between these measurements and shock impedance at the conversion test. We enrolled 43 patients with S-ICDs (mean [±SD] age 54±15 years; body mass index 23±4 kg/m2; PRAETORIAN score 30-270 points; amount of adipose tissue 1,250±716 cm3), who underwent intraoperative conversion tests by inducing ventricular fibrillation, which was terminated with a 65-J shock. A sufficient concordance correlation coefficient was observed between the shock impedance and the amount of adipose tissue (r=0.616, P<0.01) and anteroposterior diameter (r=0.645, P<0.01). In multiple regression analysis, the amount of adipose tissue (ß=0.439, P=0.009) and anteroposterior diameter (ß=0.344, P=0.038) were identified as independent predictive factors of shock impedance. CONCLUSIONS: The preoperative CT-measured amount of adipose tissue and basal heart anteroposterior diameter are independent predictors of shock impedance. These parameters may be more accurate in identifying higher shock impedance in patients with S-ICDs.


Subject(s)
Defibrillators, Implantable , Electric Impedance , Tomography, X-Ray Computed , Humans , Middle Aged , Male , Female , Aged , Adult , Adipose Tissue/diagnostic imaging , Ventricular Fibrillation/therapy , Ventricular Fibrillation/diagnostic imaging , Ventricular Fibrillation/physiopathology , Predictive Value of Tests
2.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-37438144

ABSTRACT

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Subject(s)
Heart Failure , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Angiography , Heart Failure/diagnostic imaging , Kaplan-Meier Estimate , Kidney/diagnostic imaging , Treatment Outcome
3.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38008428

ABSTRACT

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Proportional Hazards Models , Cardiac Catheterization
4.
Circ J ; 2024 Jan 12.
Article in English | MEDLINE | ID: mdl-38220206

ABSTRACT

BACKGROUND: This study aimed to clarify the effects of exercise-based cardiac rehabilitation (CR) on patients with heart failure.Methods and Results: Patients were divided into groups according to intervention duration (<6 and ≥6 months). We searched for studies published up to July 2023 in Embase, MEDLINE, PubMed, and the Cochrane Library, without limitations on data, language, or publication status. We included randomized controlled trials comparing the efficacy of CR and usual care on mortality, prehospitalization, peak oxygen uptake (V̇O2), and quality of life. Seventy-two studies involving 8,495 patients were included in this review. It was found that CR reduced the risk of rehospitalization for any cause (risk ratio [RR] 0.80; 95% confidence interval [CI] 0.70-0.92) and for heart failure (RR 0.88; 95% CI 0.78-1.00). Furthermore, CR was found to improve exercise tolerance (measured by peak V̇O2and the 6-min walk test) and quality of life. A subanalysis performed based on intervention duration (<6 and ≥6 months) revealed a similar trend. CONCLUSIONS: Our meta-analysis showed that although CR does not reduce mortality, it is effective in reducing rehospitalization rates and improving exercise tolerance and quality of life, regardless of the intervention duration.

5.
Echocardiography ; 41(1): e15712, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37937359

ABSTRACT

BACKGROUNDS: There are limited data on the clinical relevance of transvalvular flow rate (Qmean ) at rest (Qrest) and at peak stress (Qstress ) during dobutamine stress echocardiography (DSE) in patients with low-gradient severe aortic stenosis (LG-SAS). METHODS: We retrospectively analyzed the clinical data of patients with LG-SAS who underwent DSE. LG-SAS was defined as an aortic valve (AV) area index of < .6 cm2 /m2 and a mean AV pressure gradient (AVPG) of < 40 mm Hg. The primary endpoint included all-cause death and heart failure hospitalization. RESULTS: Of 100 patients (mean age 79.5 ± 7.3 years; men, 45.0%; resting left ventricular ejection fraction [LVEF] 52.1% ± 15.9%; resting stroke volume index 35.8 ± 7.7 mL/m2 ; Qrest 171.8 ± 34.9 mL/s), the primary endpoint occurred in 51 patients during a median follow-up of 2.84 (interquartile range 1.01-5.21) years. When the study patients were divided into three subgroups based on Qrest and Qstress , the multivariate analysis showed that Qrest < 200 mL/s and Qstress ≥200 mL/s (hazard ratio 3.844; 95% confidence interval 1.143-12.930; p = .030), as well as Qrest and Qstress < 200 mL/s (hazard ratio 9.444; 95% confidence interval 2.420-36.850; p = .001), were significantly associated with unfavorable outcomes with Qrest and Qstress ≥200 mL/s as a reference after adjusting for resting LVEF, resting mean AVPG, chronic kidney disease, New York Heart Association functional class III/IV, and AV replacement. CONCLUSIONS: Flow conditions based on the combination of Qrest and Qstress are helpful for risk stratification in LG-SAS patients.


Subject(s)
Aortic Valve Stenosis , Ventricular Function, Left , Male , Humans , Aged , Aged, 80 and over , Stroke Volume , Prognosis , Echocardiography, Stress , Aortic Valve Stenosis/diagnostic imaging , Retrospective Studies , Aortic Valve/diagnostic imaging , Severity of Illness Index
6.
Circ J ; 2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37482412

ABSTRACT

BACKGROUND: It remains unclear which comorbidities, other than lipid parameters, or combination of comorbidities, best predicts cardiovascular events in patients with known coronary artery disease (CAD) treated with statins. Therefore, we aimed to identify the nonlipid-related prognostic factors and risk stratification of patients with stable CAD enrolled in the REAL-CAD study.Methods and Results: Blood pressure, glucose level, and renal function were considered as risk factors in the 11,141 enrolled patients. The primary endpoint was a composite of cardiovascular death, nonfatal myocardial infarction, nonfatal ischemic stroke, and unstable angina. The secondary composite endpoint was the primary endpoint and/or coronary revascularization. A significantly worse prognosis at the primary endpoint was observed in the estimated glomerular filtration rate (eGFR) ≤60 group, and the combination of eGFR ≤60 and HbA1c ≥6.0 was the worst (hazard ratio (HR) 1.66; P<0.001). However, even in the eGFR >60 group, systolic blood pressure (SBP) ≥140 mmHg met the secondary endpoint (HR 1.33; P=0.006), and the combination of eGFR ≤60 and HbA1c ≥6.0 was also the worst at the secondary endpoint (HR 1.35; P=0.002). CONCLUSIONS: Regarding nonlipid prognostic factors contributing to the incidence of cardiovascular events in statin-treated CAD patients, renal dysfunction was the most significant, followed by poor glucose control and high SBP.

7.
Circ J ; 87(4): 517-524, 2023 03 24.
Article in English | MEDLINE | ID: mdl-36624061

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) has been used for percutaneous atrial septal defect (ASD) closure, with intracardiac echocardiography (ICE) guidance recently being introduced.Methods and Results: The Japanese Structural Heart Disease Registry was established by the Japanese Association of Cardiovascular Intervention and Therapeutics. This study analyzed data from the Registry for 2,859 consecutive cases undergoing percutaneous ASD closure between January 2015 and December 2020. ASD closure was performed under ICE guidance (n=519; 18.2%), TEE guidance (n=1,428; 49.9%), or TEE plus ICE guidance ("Both"; n=900 cases; 31.5%). The success rates were similar in the TEE, ICE, and both groups (99.0%, 99.2%, vs. 98.0%, respectively; P=0.054), as were complication rates (1.2%, 0.5%, vs. 2.1%, respectively; P=0.24). In the TEE and Both groups, 92.4% and 79.6% of patients required general anesthesia, compared with only 2.9% of patients in the ICE group (P<0.001). Fluoroscopic time was longer in the ICE and Both groups than in the TEE group (median [interquartile range] 19 [14-28] and 21 [13-30] vs. 12 [8-19] min, respectively; P<0.001). Rim deficiency and larger defect diameter were inversely related, whereas hospital volume was positively related to ICE guidance. CONCLUSIONS: Percutaneous transcatheter ASD closure was as feasible under ICE as under TEE guidance. ICE guidance is used for less challenging cases in high-volume centers in Japan.


Subject(s)
Cardiac Catheterization , Heart Septal Defects, Atrial , Humans , Cardiac Catheterization/methods , Treatment Outcome , Echocardiography, Transesophageal/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Fluoroscopy
8.
Pacing Clin Electrophysiol ; 46(12): 1643-1651, 2023 12.
Article in English | MEDLINE | ID: mdl-37904603

ABSTRACT

BACKGROUND: Predictors of worsening atrioventricular valve regurgitation and left ventricular (LV) systolic function after implantation of a leadless pacemaker (LPM) remain unclear compared with those of a transvenous pacemaker (TPM). METHODS: We retrospectively analyzed 205 patients who were newly implanted with a permanent pacemaker (119 LPMs and 86 TPMs) and underwent transthoracic echocardiography before and 8 ± 5 months after implantation. We evaluated the worsening of tricuspid and mitral regurgitation (TR and MR), defined as at least one-grade aggravation in severity, and changes in LV ejection fraction (LVEF). RESULTS: Worsening TR occurred more frequently in the LPM group compared to the TPM group (33% vs. 20%, p = .04); however, there was no significant difference between the two groups regarding worsening MR (26% vs. 18%, p = .18) and LVEF change (-2 ± 10% vs. -3 ± 8%, p = .40). In multivariable analysis, independent predictors for worsening TR, MR, and LVEF after implantation were found to be (1) the change from sinus rhythm at baseline to atrioventricular asynchronous right ventricular (RV) pacing (odds ratio [OR]: 5.68, 95% confidence interval [CI]: 1.94-16.70, p < .01); (2) the change from non-pacing ventricular contraction at baseline to RV pacing (OR: 2.42, 95% CI: 1.12-5.24, p = .02); and (3) a higher RV pacing burden (ß: -0.05, 95% CI: -0.08--0.02, p < .01), respectively. CONCLUSION: Worsening TR, MR, and LVEF after pacemaker implantation were not associated with the type of pacing device but loss of atrioventricular synchrony or dependency on RV pacing.


Subject(s)
Mitral Valve Insufficiency , Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Cardiac Pacing, Artificial , Retrospective Studies , Ventricular Function, Left , Mitral Valve Insufficiency/therapy
9.
Heart Vessels ; 38(1): 56-65, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35895151

ABSTRACT

The ventilatory efficiency for carbon dioxide output ([Formula: see text]CO2) during exercise, as measured by the minute ventilation vs. [Formula: see text]CO2 slope ([Formula: see text]E vs. [Formula: see text]CO2 slope), is a powerful prognostic index in patients with chronic heart failure (CHF). This measurement is higher in women than in men, and it increases with age. This study aimed to investigate the usefulness of the predicted value of the percentage [Formula: see text]E vs. [Formula: see text]CO2 slope (%[Formula: see text]E vs. [Formula: see text]CO2 slope) as a prognostic index in patients with CHF. A total of 320 patients with CHF and a left ventricular ejection fraction (LVEF) < 45% (male, 85.6%; mean age, 64.6 years) who underwent symptom-limited cardiopulmonary exercise tests using a cycle ergometer were included in the study. The %[Formula: see text]E vs. [Formula: see text]CO2 was calculated using predictive formulae based on age and sex. Cardiovascular-related death was defined as the primary endpoint. The mean follow-up duration was 7.5 ± 3.3 years. Of 101 patients who died during the study period, 75 experienced cardiovascular-related deaths. The average [Formula: see text]E vs. [Formula: see text]CO2 slope was 32.8 ± 8.0, and the average %[Formula: see text]E vs. [Formula: see text]CO2 slope was 119.6 ± 28.2%. The cumulative incidence of cardiovascular-related death after 10 years of follow-up were 44.7% (95% CI 34.4-54.6%) in patients with %[Formula: see text]E vs. [Formula: see text]CO2 slope > 120 and 15.0% (95% CI 9.4-21.8%) in patients with %[Formula: see text]E vs. [Formula: see text]CO2 slope ≤ 120. The multivariate Cox regression analysis indicated that a %[Formula: see text]E vs. [Formula: see text]CO2 slope > 120 was an independent predictor of cardiovascular-related death (adjusted hazard ratio, 3.24; 95% confidence interval 1.65-6.67; p < 0.01). The %[Formula: see text]E vs. [Formula: see text]CO2 slope can be used for risk stratification in patients with CHF and an LVEF < 45%.


Subject(s)
Carbon Dioxide , Heart Failure , Humans , Male , Female , Middle Aged , Stroke Volume , Oxygen Consumption , Ventricular Function, Left , Chronic Disease , Heart Failure/diagnosis , Heart Failure/therapy , Exercise Test
10.
Heart Vessels ; 38(8): 1075-1082, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36932249

ABSTRACT

Circulatory power (CP) and ventilatory power (VP), obtained by cardiopulmonary exercise testing (CPX), have been suggested to be excellent prognostic markers for heart failure. However, the normal values of these parameters in healthy Japanese populations remain unknown; thus, we aimed to investigate these values in such a population. A total of 391 healthy Japanese participants, 20-78 years of age, underwent CPX with a cycle ergometer with ramp protocols. Systolic blood pressure (SBP), heart rate, oxygen uptake ([Formula: see text]O2) at peak exercise, and the slope of minute ventilation ([Formula: see text]E) versus carbon dioxide ([Formula: see text]CO2) ([Formula: see text]E vs. [Formula: see text]CO2 slope) were measured. CP was calculated by multiplying the peak [Formula: see text]O2 and SBP values, and VP was calculated by dividing the peak SBP value by the [Formula: see text]E versus [Formula: see text]CO2 slope. For males and females, the average CP values were 6119 ± 1280 (mean ± standard deviation) and 4775 ± 914 mmHg·mL/min/kg, respectively (p < 0.001). The average VP values for males and females were 8.0 ± 1.3 and 6.9 ± 1.3 mmHg (p < 0.001). CP decreased with age in both sexes. VP increased with age in females, with no significant change in males. We calculated the normal values for CP and VP in a healthy Japanese population. The results can contribute to the evaluation of patients' CPX results as a reference.


Subject(s)
Carbon Dioxide , East Asian People , Exercise Test , Female , Humans , Male , Exercise/physiology , Oxygen Consumption , Reference Values , Young Adult , Adult , Middle Aged , Aged , Healthy Volunteers
11.
Int Heart J ; 64(6): 1157-1161, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-37967987

ABSTRACT

A 59-year-old man who had been diagnosed with human immunodeficiency virus-associated cardiomyopathy was referred for catheter ablation of ventricular tachycardia (VT). An electrocardiogram (ECG) waveform revealed that the clinical VT originated from the epicardium. A deceleration zone (DZ) was identified on an isochronal late activation map. Moreover, 2 forms of monomorphic VT were induced by different cycle length burst pacings from near the DZ. The morphologies of the 2 VTs with an identical cycle length were very likely to use a shared common pathway with bi-directional conduction around the slow conduction area in the left ventricle posterolateral small epicardial surface area. After ablation of the DZ, the VT was uninducible.


Subject(s)
Cardiomyopathies , Catheter Ablation , Tachycardia, Ventricular , Male , Humans , Middle Aged , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac/surgery , Heart Rate/physiology , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Treatment Outcome
12.
Angiogenesis ; 25(4): 535-546, 2022 11.
Article in English | MEDLINE | ID: mdl-35802311

ABSTRACT

BACKGROUND: Patients with critical limb ischemia (CLI) still have a high rate of lower limb amputation, which is associated with not only a decrease in quality of life but also poor life prognosis. Implantation of adipose-derived regenerative cells (ADRCs) has an angiogenic potential for patients with limb ischemia. OBJECTIVES: We investigated safety, feasibility, and efficacy of therapeutic angiogenesis by cell transplantation (TACT) of ADRCs for those patients in multicenter clinical trial in Japan. METHODS: The TACT-ADRC multicenter trial is a prospective, interventional, open-labeled study. Patients with CLI (Fontaine class III-IV) who have no other option for standard revascularization therapy were enrolled in this study. Thirty-four target ischemic limbs of 29 patients were received freshly isolated autologous ADRCs implantation. RESULTS: The overall survival rate at a post-operative period and at 6 months follow-up was 100% at any time points. As a primary endpoint for efficacy evaluation, 32 limbs out of 34 (94.1%) were free from major amputation for 6 months. Numerical rating scale (from 6 to 1) as QOL score, ulcer size (from 317 mm2 at to 109 mm2), and 6-min walking distance (from 255 to 369 m) improved in 90.6%, 83.3%, and 72.2% patients, respectively. CONCLUSIONS: Implantation of autologous ADRCs could be safe and effective for the achievement of therapeutic angiogenesis in the multicenter settings, as a result in no major adverse event, optimal survival rate, and limb salvage for patients with no-conventional option against critical limb ischemia. TRN: jRCTb040190118; Date: Nov. 24th, 2015.


Subject(s)
Chronic Limb-Threatening Ischemia , Quality of Life , Amputation, Surgical , Humans , Ischemia , Neovascularization, Pathologic , Prospective Studies , Treatment Outcome
13.
Circ J ; 86(8): 1283-1291, 2022 07 25.
Article in English | MEDLINE | ID: mdl-35095057

ABSTRACT

BACKGROUND: Implanting a ventricular demand leadless pacemaker (VVI-LPM) for patients with non-atrial fibrillation (AF) bradyarrhythmias such as sick sinus syndrome (SSS) or high-grade (i.e., second- or third-degree) atrioventricular (AV) block is not recommended unless they have limited vascular access or a high infection risk; nevertheless, an unexpectedly high number of VVI-LPM implantations have been performed. This study investigated the clinical outcomes of these unusual uses.Methods and Results:This study retrospectively analyzed 193 patients who were newly implanted with a VVI-LPM or an atrioventricular synchronous transvenous pacemaker (DDD-TPM) for non-AF bradyarrhythmias at a high-volume center in Japan from September 2017 to September 2020. Propensity score-matching produced 2 comparable cohorts treated with a VVI-LPM or DDD-TPM (n=58 each). Each group had 20 (34%) patients with SSS and 38 (66%) patients with high-grade AV block. During a median follow up of 733 (interquartile range 395-997) days, there were no significant differences between the VVI-LPM and DDD-TPM groups regarding late device-related adverse events (0% vs. 4%, log-rank P=0.155), but the VVI-LPM group had a significantly increased readmission rate for heart failure (HF) (29% vs. 2%, log-rank P=0.001) and a tendency to have higher all-cause mortality (28% vs. 4%, log-rank P=0.059). CONCLUSIONS: The implantation of a VVI-LPM for non-AF bradyarrhythmias increased the incidence of HF-related rehospitalization at the mid-term follow up compared to the use of a DDD-TPM.


Subject(s)
Atrioventricular Block , Heart Failure , Pacemaker, Artificial , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Bradycardia/therapy , Cardiac Pacing, Artificial/methods , Follow-Up Studies , Heart Failure/etiology , Humans , Pacemaker, Artificial/adverse effects , Propensity Score , Retrospective Studies
14.
Echocardiography ; 39(10): 1338-1343, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36184264

ABSTRACT

BACKGROUND: Although Doppler evaluation using a multiplanar method is recommended to assess the severity of aortic stenosis (AS) with transthoracic echocardiography, evidence on the diagnostic significance of a non-apical method is limited. This study aimed to compare the use of the apical with the use of the right parasternal view (RPV) method to evaluate AS severity and to examine the diagnostic significance of performing the RPV method in addition to the apical method during the evaluation. METHODS: This retrospective observational study included 276 consecutive patients (mean age: 79 ± 10 years; women, 56%) with severe AS (aortic valve area [AVA] ≤1.0cm2 ). The severity of AS according to the apical method and that according to the RPV for all subjects were compared, and the significance of performing the RPV method in addition to the apical method was examined. Furthermore, we compared the concordance group, in which the apical and RPV methods indicated matching in severity, and the discordant group, in which the apical and RPV methods did not indicate matching severity. RESULTS: Peak velocity (Vmax ), mean pressure gradient (MG) were significantly higher and the AVA, AVAi, and Doppler velocity index (DVI) were significantly smaller when the RPV was added to the apical view. Performing the RPV method in addition to the apical method significantly decreased the number of low PG AS cases (MG < 40 mmHg) from 69.9% to 65.0% and it increased the number of very severe AS cases (Vmax ≥ 5 m/s) from 8.7% to 14.5%. Deviation of Doppler angle was significantly greater in the discordant group compared to the concordant group (22.5 ± .6 vs. 31.8 ± 1.7, p < .001). CONCLUSIONS: By performing the RPV method in addition to the apical method to determine AS severity, the diagnosis of AS to be resolved in approximately 10% of cases. These results suggest that AS severity may be underestimated by using the apical method alone.


Subject(s)
Aortic Valve Stenosis , Echocardiography, Doppler , Humans , Female , Aged , Aged, 80 and over , Echocardiography, Doppler/methods , Severity of Illness Index , Aortic Valve Stenosis/diagnostic imaging , Echocardiography/methods , Retrospective Studies , Aortic Valve/diagnostic imaging
15.
Circ J ; 85(8): 1265-1272, 2021 07 21.
Article in English | MEDLINE | ID: mdl-33790146

ABSTRACT

BACKGROUND: The optimum cut-off value of premature atrial contraction (PAC) burden (CV-PACb) in 24-h Holter electrocardiography (24-h ECG) for predicting atrial fibrillation (AF) is debatable, with few validation data.Methods and Results:We retrospectively analyzed 61 patients already diagnosed with AF (AD-AF) and 147 patients never diagnosed with AF (ND-AF), aged ≥50 years, free of heart disease, and who had undergone 24-h ECG and transthoracic echocardiography (TTE). Receiver operating characteristic analysis demonstrated that 0.4% was the optimal CV-PACb differentiating AD-AF from ND-AF, with 69% sensitivity and 72% specificity (area under the curve [AUC] 0.72; 95% confidence interval [CI] 0.65-0.79); however, the left atrial volume index was not significant (AUC 0.60; 95% CI 0.51-0.68). To verify the CV-PACb, new propensity-matched cohorts (i.e., subjects with a PAC burden ≥0.4% and <0.4%; n=69 in each group) were compared based on new detection of AF at a median follow-up of 50 months (interquartile range 12-60 months) Multivariable Cox regression analysis revealed that among 24-h ECG and TTE findings, only PAC burden ≥0.4% was independently associated with incident AF (hazard ratio 5.28; 95% CI 1.28-26.11; P=0.023). CONCLUSIONS: A high PAC burden (≥0.4%) in 24-h ECG was a reliable indicator to identify undiagnosed AF, whereas TTE parameters did not show any predictive value.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/diagnosis , Atrial Premature Complexes/diagnosis , Electrocardiography , Electrocardiography, Ambulatory , Humans , Middle Aged , Predictive Value of Tests , Prognosis , Propensity Score , Retrospective Studies , Risk Factors
16.
Circ J ; 85(7): 1068-1075, 2021 06 25.
Article in English | MEDLINE | ID: mdl-33762527

ABSTRACT

BACKGROUND: Although diastolic flow reversal (DFR) in the descending aorta, assessed via transesophageal echocardiography (TEE), is a simple and easy indicator for evaluating aortic regurgitation, the association between DFR pattern and clinical outcomes following transcatheter aortic valve implantation (TAVI) is unclear. The purpose of this study was to evaluate the effect of DFR patterns on clinical outcomes following TAVI.Methods and Results:Two-hundred and eleven patients (mean age, 83.6±5.7 years; 69% female) who underwent TAVI were retrospectively assessed via intraprocedural TEE. DFR was evaluated using pulsed-wave Doppler in the descending aorta before and after TAVI. The primary endpoint was major adverse cardio-cerebrovascular events (MACCEs). Although only 7 patients (3.3%) had moderate or severe paravalvular leak, as assessed by color Doppler echocardiography, holo-DFR (HDFR) was observed in 33 patients (16.0%) after TAVI. MACCEs occurred in 40 patients during the median follow up of 282 days (interquartile range: 160-478 days). The estimated cumulative MACCE-free survival at 1 year was significantly lower in patients with HDFR than in those without HDFR. A Cox proportional hazards analysis revealed that HDFR after TAVI was independently associated with MACCEs. CONCLUSIONS: HDFR was associated with an increased risk of MACCEs after TAVI. DFR evaluated by intraprocedural echocardiography could serve as a simple and easy method for predicting clinical outcomes.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography , Echocardiography, Transesophageal , Female , Humans , Male , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
17.
Scand Cardiovasc J ; 55(5): 270-278, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34291701

ABSTRACT

Background. Moderate aortic stenosis (AS) increases left ventricular afterload and results in unfavorable outcomes in patients with reduced left ventricular ejection fraction (LVEF). Velocity ratio (VR) may be appropriate for the evaluation of aortic valve (AV) hemodynamics because of the low dependence on flow. Therefore, this study investigated the usefulness of VR on the clinical outcomes of such patients. Method. Clinical data of patients with moderate AS (AV area, 0.60-0.85 cm2/m2; peak AV velocity, 2.0-4.0 m/s) and reduced LVEF (LVEF 20-50%) were analyzed during 2010-2018. VR was calculated as peak left ventricular outflow tract velocity/peak AV velocity. The primary endpoint included all-cause death, heart failure hospitalization, and AV replacement. Results. In total, 104 patients (mean age, 75.9 ± 7.0 years; 62.5% men) were included. LVEF was 39.5% ± 7.8%. The AV area was 0.72 ± 0.08 cm2/m2, peak AV velocity was 2.59 ± 0.40 m/s, and VR was 0.30 ± 0.07. The follow-up period was 1.7 (0.5-3.5) years. Kaplan-Meier estimates for the endpoint were 59.9% at 3 years. Multivariable analysis revealed that VR (hazard ratio, 0.947; 95% confidence interval, 0.905-0.990; p = .018) was significantly related to this endpoint. Patients with a VR <0.25 had significantly higher incidence rates of the endpoint than those with a VR ≥0.25 (85.6% versus 47.8% at 3 years; p < .001). Conclusions. Patients with moderate AS and reduced LVEF have unfavorable clinical outcomes, particularly those with low VR.


Subject(s)
Aortic Valve Stenosis , Stroke Volume , Ventricular Function, Left , Aged , Aged, 80 and over , Aortic Valve Stenosis/physiopathology , Blood Flow Velocity/physiology , Female , Humans , Male , Patient Acuity , Stroke Volume/physiology , Ventricular Function, Left/physiology
18.
Heart Vessels ; 36(6): 782-789, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33452916

ABSTRACT

Despite the known association of cardiac rupture with acute myocardial infarction (AMI), it is still unclear whether the clinical characteristics are associated with the risk of in-hospital mortality in patients with AMI complicated by cardiac rupture. The purpose of this study was to investigate the association between the time of cardiac rupture occurrence and the risk of in-hospital mortality after AMI. We conducted a retrospective analysis of multicenter registry data from eight medical universities in Eastern Japan. From 10,278 consecutive patients with AMI, we included 183 patients who had cardiac rupture after AMI, and examined the incidence of in-hospital deaths during a median follow-up of 26 days. Patients were stratified into three groups according to the AMI-to-cardiac rupture time, namely the > 24-h group (n = 111), 24-48-h group (n = 20), and < 48-h group (n = 52). Cox proportional hazards regression analysis was used to estimate the hazard ratio (HR) and the confidence interval (CI) for in-hospital mortality. Around 87 (48%) patients experienced in-hospital death and 126 (67%) underwent a cardiac surgery. Multivariable Cox regression analysis revealed a non-linear association across the three groups for mortality (HR [CI]; < 24 h: 1.0, reference; 24-48 h: 0.73 [0.27-1.86]; > 48 h: 2.25 [1.22-4.15]) after adjustments for age, sex, Killip classification, percutaneous coronary intervention, blood pressure, creatinine, peak creatine kinase myocardial band fraction, left ventricular ejection fraction, and type of rupture. Cardiac surgery was independently associated with a reduction in the HR of mortality (HR [CI]: 0.27 [0.12-0.61]) and attenuated the association between the three AMI-to-cardiac rupture time categories and mortality (statistically non-significant) in the Cox model. These data suggest that the AMI-to-cardiac rupture time contributes significantly to the risk of in-hospital mortality; however, rapid diagnosis and prompt surgical interventions are crucial for improving outcomes in patients with cardiac rupture after AMI.


Subject(s)
Biomedical Research , Heart Rupture, Post-Infarction/epidemiology , Myocardial Infarction/diagnosis , Registries , Risk Assessment/methods , Universities , Aged , Female , Follow-Up Studies , Heart Rupture, Post-Infarction/diagnosis , Heart Rupture, Post-Infarction/physiopathology , Hospital Mortality/trends , Humans , Incidence , Japan/epidemiology , Male , Myocardial Infarction/mortality , Retrospective Studies , Risk Factors , Stroke Volume/physiology , Survival Rate/trends , Time Factors
19.
Heart Vessels ; 36(7): 1072-1079, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33484292

ABSTRACT

Preoperative frailty diminishes the potential for functional recovery after transcatheter aortic valve implantation (TAVI). However, perioperative changes in physical status and their impact on prognosis after TAVI have not previously been reported. Therefore, this study aimed to investigate whether perioperative changes in physical function affect prognosis in patients undergoing TAVI. We retrospectively reviewed 257 patients who underwent TAVI. The Short Physical Performance Battery (SPPB), an objective physical status assessment tool, was evaluated pre- and post-TAVI. Patients were divided into two groups: (i) patients whose SPPB score declined in the perioperative period (the decline group) and (ii) patients whose SPPB score did not decline in the perioperative period (the non-decline group). The primary endpoint was unplanned hospitalization owing to heart failure or cardiovascular death following TAVI. The mean follow-up period was 385 ± 151 days, mean age was 83.2 ± 5.8 years, and 67% of the patients were women. Sixteen patients required readmission owing to heart failure, and seven experienced cardiovascular-related death. Kaplan-Meier analysis revealed that the event-free rate was significantly lower in the decline group (log-rank, p = 0.006). A stepwise multivariate logistic regression analysis showed that a perioperative change in SPPB was significantly associated with primary endpoints (odds ratio, 1.51; 95% confidence interval, 1.12-2.04). Perioperative change in physical function was an independent risk factor for heart failure, hospitalization, or cardiovascular death following TAVI.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Exercise/physiology , Frailty/physiopathology , Risk Assessment/methods , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/epidemiology , Female , Follow-Up Studies , Frailty/epidemiology , Frailty/etiology , Humans , Incidence , Japan/epidemiology , Male , Patient Readmission/trends , Perioperative Period , Prognosis , Retrospective Studies , Risk Factors , Survival Rate/trends , Time Factors , Treatment Outcome
20.
Echocardiography ; 38(6): 916-923, 2021 06.
Article in English | MEDLINE | ID: mdl-33971038

ABSTRACT

BACKGROUND: The risk stratification of hypertrophic cardiomyopathy (HCM) without left ventricular outflow tract (LVOT) obstruction and the utility of exercise stress echocardiography (ESE) remains unclear. We investigated the value of right ventricular (RV) function and RV-pulmonary artery (PA) coupling during exercise in asymptomatic/minimally symptomatic patients with nonobstructive HCM (nHCM). METHOD AND RESULTS: This retrospective study evaluated 74 HCM patients (age 63 ± 13 years, 65% men) without LVOT obstruction (≥30 mmHg) who underwent​ ESE. Eight patients (11%) suffered from HCM-related cardiac events during a median 2.5 years follow-up. During exercise, tricuspid annular plane systolic excursion (Ex-TAPSE) and Ex-TAPSE/systolic pulmonary artery pressure [SPAP] ratio were more impaired in patients with than in those without events (22 ± 4 vs 26 ± 4 mm, P = .005; and 0.45 [0.41, 0.47] vs 0.56 [0.47, 0.82] mm/mmHg, P = .002). In Cox regression analysis, Ex-TAPSE (HR: 1.397, P = .002) and the Ex-TAPSE/SPAP ratio (HR: 2.737, P = .006) were associated with cardiac events. In Kaplan-Meier analysis, patients with a low Ex-TAPSE (<24 mm) and Ex-TAPSE/SPAP ratio (<0.50 mm/mmHg) had a higher incidence of adverse outcomes than those with high Ex-TAPSE (Log rank, P < .001 and =.001, respectively). CONCLUSIONS: A low Ex-TAPSE and Ex-TAPSE/SPAP ratio were associated with adverse outcomes in nHCM. Evaluation of RV functional performance during exercise may play a crucial role in the risk stratification of nHCM.


Subject(s)
Cardiomyopathy, Hypertrophic , Ventricular Dysfunction, Right , Aged , Cardiomyopathy, Hypertrophic/diagnostic imaging , Female , Humans , Male , Middle Aged , Prognosis , Retrospective Studies , Systole , Ventricular Function, Right
SELECTION OF CITATIONS
SEARCH DETAIL