Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Aust N Z J Obstet Gynaecol ; 60(5): 675-682, 2020 10.
Article in English | MEDLINE | ID: mdl-32124434

ABSTRACT

BACKGROUND: Competing risk models used for midpregnancy prediction of preterm pre-eclampsia have shown detection rates (DR) of 85%, at fixed false-positive rate (FPR) of 10%. The full algorithm used between 19+0 and 24+6  weeks includes maternal factors, mean arterial pressure (MAP), mean uterine artery pulsatility index (UtAPI), serum placental growth factor (PlGF) level in multiples of the median (MoM), and soluble Fms-like tyrosine kinase-1 (sFlt-1) level in MoM. AIMS: To assess performance of the Fetal Medicine Foundation (FMF) algorithm at midpregnancy to screen for preterm (<37 weeks) pre-eclampsia. The outcome measured was preterm pre-eclampsia. MATERIALS AND METHODS: This is a prospective study including singleton pregnancies at 19-22 weeks gestation. Maternal bloods were collected and analysed using three different immunoassay platforms. Maternal characteristics, medical history, MAP, mean UtAPI, serum PlGF MoM and serum sFlt-1 MoM were used for risk assessment. DR and FPR were calculated, and receiver operating characteristic curves produced. RESULTS: Five hundred and twelve patients were included. Incidence of preterm pre-eclampsia was 1.6%. Using predicted risk of pre-eclampsia of one in 60 or more and one in 100 or higher, as given by the FMF predictive algorithm, the combination with the best predictive performance for preterm pre-eclampsia included maternal factors, MAP, UtAPI and PlGF MoM, giving DRs of 100% and 100%, respectively, and FPRs of 9.3 for all platforms and 12.9-13.5, respectively. Addition of sFlt-1 to the algorithm did not appear to improve performance. sFlt-1 MoM and PlGF MoM values obtained on the different platforms performed very similarly. CONCLUSIONS: Second trimester combined screening for preterm pre-eclampsia by maternal history, MAP, mean UtAPI and PlGF MoM using the FMF algorithm performed very well in this patient population.


Subject(s)
Pre-Eclampsia , Algorithms , Biomarkers , Female , Humans , Infant, Newborn , Placenta Growth Factor , Pre-Eclampsia/diagnosis , Predictive Value of Tests , Pregnancy , Prospective Studies , Vascular Endothelial Growth Factor Receptor-1
2.
Aust N Z J Obstet Gynaecol ; 58(2): 192-196, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28850663

ABSTRACT

AIM: To compare the performance of three different screening methods (National Institute for Health and Clinical Excellence (NICE) guidelines, American College of Obstetricians and Gynecologists (ACOG) recommendations and Fetal Medicine Foundation (FMF) algorithm) for second trimester prediction of preeclampsia. METHODS: This was a prospective non-intervention study in singleton pregnancies, including women attending for second trimester morphologic ultrasound at 19-22 weeks. Maternal characteristics, medical history, mean arterial pressure and mean uterine artery Doppler pulsatility index were recorded and used for risk assessment. Outcomes measured were preeclampsia with delivery before 34, before 37 and after 37 weeks gestation. Detection rates, false positive rates and positive likelihood ratios were calculated, and receiver operating characteristic curves were produced. RESULTS: We screened 543 women during the study. The incidence of preeclampsia before 34, before 37 and after 37 weeks was 0.5, 1.4 and 3.4%, respectively. Detection rates for prediction of preterm preeclampsia were 75% (95% CI 34.9-96.8), 87% (95% CI 47.3-99.6), 100% (95% CI 63.0-100) and 100% (95% CI 63.0-100) for NICE guidelines, ACOG recommendations, FMF algorithm with a 1:100 cut-off and FMF algorithm at 1:60 cut-off, respectively. False positive rates were, 22, 67, 19 and 12% for NICE guidelines, ACOG recommendations, FMF algorithm with a 1:100 cut-off and FMF algorithm at 1:60 cut-off, respectively. CONCLUSION: Second trimester combined screening for preterm preeclampsia by maternal history, mean arterial pressure and mean uterine artery Doppler pulsatility index (FMF algorithm) was superior to screening by maternal factors alone (NICE guidelines and ACOG recommendations).


Subject(s)
Algorithms , Pre-Eclampsia/diagnosis , Prenatal Diagnosis , Adult , Female , Humans , Pre-Eclampsia/physiopathology , Predictive Value of Tests , Pregnancy , Pregnancy Trimester, Second , Prospective Studies , Pulsatile Flow , Risk Assessment , Ultrasonography, Prenatal , Uterine Artery/physiology , Victoria
3.
Placenta ; 86: 11-14, 2019 10.
Article in English | MEDLINE | ID: mdl-31491692

ABSTRACT

We performed an inter-assay comparison among three immunoassay platforms for midpregnancy testing of sFlt-1, PlGF and the sFlt-1/PlGF ratio, which are established markers for pre-eclampsia. Maternal blood was collected 19-22 weeks' gestation. Raw data values were converted to multiples of the median (MoM). PlGF and sFlt-1 values among platforms were highly correlated (p < 0.001). There was significant variation in raw data values for PlGF and sFlt-1 among platforms, eliminated following conversion to MoM. When directly comparing raw data values among platforms, platform-specific reference ranges values should be used. MoM values were equivalent among platforms, allowing direct inter-assay result comparison.


Subject(s)
Immunoassay/instrumentation , Placenta Growth Factor/blood , Vascular Endothelial Growth Factor Receptor-1/blood , Biomarkers/blood , Female , Humans , Pregnancy
4.
Pregnancy Hypertens ; 16: 112-119, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31056145

ABSTRACT

OBJECTIVES: Pre-eclampsia remains a significant cause of morbidity and mortality. Placental biomarkers soluble Fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PlGF) have been investigated previously for their ability to predict pre-eclampsia. We compared the performance of these biomarkers for midpregnancy pre-eclampsia prediction using three different immunoassay platforms. STUDY DESIGN: Prospective study including singleton pregnancies 19-22 weeks' gestation. Maternal bloods were collected at recruitment. Screening performances using receiver operating characteristic (ROC) curves for PlGF and sFlt-1/PlGF ratio raw data and MoM values in isolation were evaluated for three immunoassay platforms using selected cut-off values. MAIN OUTCOME MEASURES: Pre-eclampsia was defined as early-onset (<34 weeks' at delivery) and preterm (<37 weeks' at delivery). RESULTS: For prediction of preterm pre-eclampsia, PlGF MoM and sFlt-1/PlGF ratio MoM performed similarly, with areas under the curve (AUC), detection rates (DR) and false positive rates (FPR) for PlGF MoM and sFlt-1/PlGF ratio MoM being 0.77-0.79 and 0.71-0.74, 62.5% for both and 9.7-14.9 and 10.7-17.7, respectively. For the prediction of early-onset pre-eclampsia, sFlt-1/PlGF ratio raw data and MoM values performed similarly, with AUC, DR and FPR being 0.92-0.97 and 0.93-0.96, 100% for both, and 4.13-16.9 and 9.4-12.2, respectively. CONCLUSIONS: For midpregnancy prediction of preterm pre-eclampsia, PlGF MoM for all three platforms and sFlt-1/PlGF ratio MoM for the two platforms that tested sFlt-1 performed similarly. For midpregnancy prediction of early-onset pre-eclampsia at midpregnancy, sFlt-1/PlGF ratio raw data and MoM values using the early-onset cut-off for the two platforms that tested sFlt-1 gave similar performance from a clinical perspective.


Subject(s)
Membrane Proteins/blood , Pre-Eclampsia/diagnosis , Prenatal Diagnosis , Vascular Endothelial Growth Factor Receptor-1/blood , Adult , Biomarkers/blood , Female , Humans , Pre-Eclampsia/blood , Predictive Value of Tests , Pregnancy , Pregnancy Trimester, Second
5.
J Matern Fetal Neonatal Med ; 28(13): 1495-9, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25184419

ABSTRACT

OBJECTIVE: To determine the utility of ultrasound (US) in late pregnancy for identifying fetuses with growth disturbances. METHODS: This study was designed as a retrospective study of birth weights over a 12-month period at the Royal Hobart Hospital (RHH) and Barwon Health (BH). Data were collected from the discharge summaries and medical records at both hospitals targeting abnormal fetal weight below 10th percentile (small for gestational age - SGA) and above 90th percentile (large for gestational age - LGA). RESULTS: There were 4079 study patients from both hospitals. After weight adjustment by gender and gestational age, an abnormal fetal weight was detected in 741 cases (babies over the 90th percentile or below 10th percentile). One hundred and twenty-eight patients with high-risk pregnancies were excluded. Therefore, a total of 613 patients remained that were considered to be low-risk pregnancies with abnormal foetal growth; 305 patients from RHH and 308 from BH. The antenatal detection rate for LGA was 35.9%, at RHH by combination of US and clinical evaluation, while for BH it was 34.8% by clinical evaluation alone (p = 0.910). The antenatal detection rate for SGA was 36.8% via US and clinical evaluation at RHH and 54.5% by clinical evaluation alone at BH (p = 0.006). CONCLUSION: This study shows no benefit in the use of routine US for the antenatal diagnosis of LGA compared with clinical evaluation in low-risk pregnancies. US evaluation was inferior to clinical evaluation in the antenatal diagnosis of SGA in low-risk pregnancies.


Subject(s)
Fetal Macrosomia/diagnostic imaging , Infant, Small for Gestational Age , Pregnancy Trimester, Third , Ultrasonography, Prenatal , Diagnostic Tests, Routine , Female , Fetal Macrosomia/diagnosis , Gestational Age , Humans , Infant, Newborn , Predictive Value of Tests , Pregnancy , Retrospective Studies , Risk Factors , Ultrasonography, Prenatal/methods
SELECTION OF CITATIONS
SEARCH DETAIL