Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Rev Cardiovasc Med ; 24(10): 293, 2023 Oct.
Article in English | MEDLINE | ID: mdl-39077564

ABSTRACT

Background: We aimed to evaluate echocardiographic parameters to predict calcific aortic valve disease (CAVD) progression. CAVD ranges from aortic valve sclerosis (ASc) with no functional impairment of the aortic valve to severe aortic stenosis (AS). It remains uncertain, which patients with ASc have a particularly high risk of developing AS. Methods: We included a total of 153 patients with visual signs of ASc and peak flow velocity (Vmax) below 2.5 m/s at baseline echocardiography. Progression of CAVD to AS was defined as an increase in Vmax ≥ 2.5 m/s with a delta of ≥ 0.1 m/s; stable ASc was defined as Vmax below 2.5 m/s and a delta < 0.1 m/s. Finally, we compared clinical and echocardiographic parameters between these two groups. Results: The mean age at baseline was 73.5 ( ± 8.2) years and 66.7% were of male sex. After a mean follow-up of 1463 days, 57 patients developed AS, while 96 patients remained in the ASc group. The AS group showed significantly more calcification (p < 0.001) and thickening (p < 0.001) of the aortic valve cusps at baseline, although hemodynamics showed no evidence of AS in both groups (ASc group: Vmax 1.6 ± 0.3 m/s versus AS group: Vmax 1.9 ± 0.3 m/s; p < 0.001). Advanced calcification (odds ratio [OR]: 4.8, 95% confidence interval [CI]: 1.5-15.9; p = 0.009) and a cusp thickness > 0.26 cm (OR: 16.6, 95% CI: 5.4-50.7; p < 0.001) were independent predictors for the development of AS. Conclusions: The acquisition of simple echocardiographic parameter may help to identify patients with particularly high risk of developing AS.

2.
BMC Cardiovasc Disord ; 23(1): 454, 2023 09 12.
Article in English | MEDLINE | ID: mdl-37700226

ABSTRACT

BACKGROUND: Cardiovascular disease (CVD) remains the leading cause of death worldwide. The main driving force behind this association is coronary artery disease (CAD), the manifestation of atherosclerosis in the coronary circulation. Cornerstones in the development of CAD are pathologies in lipid metabolism. In recent years, ongoing research has identified ceramides, a subclass of sphingolipids to be mediators of CVD. The aim of this study is to investigate the influence of type II diabetes mellitus (DM) on circulating ceramides and hexosylceramides (HexCers) in CAD patients. METHODS: 24 patients aged 40-90 years with CAD confirmed by angiography were included into a pilot study. Patients with DM were identified by analysis of discharge letters or other medical documents available at the study center. During coronary angiography, arterial blood samples were collected and quantification of sphingolipids in patient serum was performed by mass spectrometry. RESULTS: Statistical analysis showed nine significantly different HexCers in CAD patients with DM compared to patients without DM. Among the nine significantly regulated HexCers, we identified seven d18:1 HexCers. This group contributes to the fourth most abundant subgroup of total ceramides and HexCers in this dataset. HexCer-d18:1-23:1(2-OH) showed the strongest downregulation in the patient group with DM. CONCLUSION: This study suggests that levels of circulating HexCers are downregulated in patients with CAD and concomitant DM compared to patients without DM. Further research is needed to investigate the underlying mechanisms and the suitability of HexCers as possible mediators and/or prognostic markers in CAD.


Subject(s)
Cardiovascular Diseases , Coronary Artery Disease , Diabetes Mellitus, Type 2 , Humans , Coronary Artery Disease/diagnostic imaging , Ceramides , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , Pilot Projects , Sphingolipids , Coronary Angiography
3.
Heart Vessels ; 38(2): 274-283, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36251050

ABSTRACT

In this prospective observational study, we investigated the impact of geriatric syndromes and frailty on mortality and evaluated the prognostic value of different frailty, nutritional, and geriatric assessment tools in high-risk patients with severe mitral valve regurgitation (MR) who were evaluated for mitral valve therapies including surgical, interventional, and conservative treatment options. We prospectively assessed multiple parameters including the CONUT Score, the Katz Index of independence in activities of daily living (ADL), the Fried Frailty Phenotype (FFP), and the Essential Frailty Toolset (EFT) Score in 127 patients with severe symptomatic MR requiring surgical/interventional treatment versus conservative monitoring. We compared their predictive value on mortality including multivariate regression analysis to identify the most suitable tool to predict outcomes in these patient groups. The frailty syndrome as assessed with the CONUT Score, Katz Index, EFT Score, and FFP was associated with higher rates of comorbidities, significantly higher risk scores such as logistic EuroSCORE, EuroSCORE II, and STS-PROM, and significantly higher mortality rates. The EFT Score and FFP were independent predictors of one-year all-cause mortality in our study cohort (EFT Score: HR 1.9, 95% CI 1.2 to 3.2; p = 0.01; FFP: HR 1.8, 95% CI 1.1 to 3.1; p = 0.015). Geriatric syndromes and frailty are associated with increased mortality in high-risk patients with symptomatic severe MR. The EFT Score and the FFP were independent predictors of one-year all-cause mortality.


Subject(s)
Aortic Valve Stenosis , Frailty , Mitral Valve Insufficiency , Humans , Aged , Frailty/complications , Frailty/diagnosis , Frail Elderly , Activities of Daily Living , Mitral Valve Insufficiency/surgery , Syndrome , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Geriatric Assessment
4.
Catheter Cardiovasc Interv ; 100(5): 850-859, 2022 11.
Article in English | MEDLINE | ID: mdl-35989489

ABSTRACT

BACKGROUND: A significant number of patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) suffer from extra-aortic cardiac damage. Few studies have investigated strategies to quantify cardiac damage and stratify patients accordingly in different risk groups. The aim of this retrospective multicenter study was to provide a user-friendly simplified staging system based on the proposed classification system of Généreux et al. as a tool to evaluate the prognosis of patients undergoing TAVR more easily. Moreover, we analyzed changes in cardiac damage after TAVR. METHODS: We assessed cardiac damage in patients, who underwent TAVR at the Heart Center Bonn or Düsseldorf, using pre- and postprocedural transthoracic echocardiography. Patients were assigned to the staging system proposed by Généreux et al. according to the severity of their baseline cardiac damage. Based on the established system, we created a simplified staging system to facilitate improved applicability. Finally, we compared clinical outcomes between the groups and evaluated changes in cardiac damage after TAVR. RESULTS: A total of 933 TAVR patients were included in the study. We found a significant association between cardiac damage and 1-year all-cause mortality (stage 0: 0% vs. stage 1: 3% vs. stage 2: 6.6%; p < 0.009). In multivariate analysis, cardiac damage was an independent predictor of 1-year all-cause mortality (hazard ratio: 2.0, 95% confidence interval: 1.1-3.8; p = 0.03). CONCLUSIONS: In patients undergoing TAVR, cardiac damage is associated with enhanced mortality. A simplified staging system can help identify patients at high risk for an adverse outcome.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Risk Factors , Retrospective Studies , Severity of Illness Index
5.
Catheter Cardiovasc Interv ; 99(1): 145-157, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34143555

ABSTRACT

BACKGROUND: Frailty is a multidimensional syndrome that affects mortality after aortic valve replacement (AVR). Malnutrition is often associated with the development of frailty. However, data regarding the association of frailty with nutritional status and underlying endocrinological dysregulation in patients with severe aortic valve stenosis are limited. OBJECTIVES: We aimed to systematically screen for frailty and malnutrition, to evaluate for underlying endocrinological disorders and inflammation, and to assess the ability of these parameters to predict outcomes after AVR. METHODS: Our study included 373 patients undergoing transcatheter and surgical AVR. Frailty was assessed using the Fried Frailty Phenotype (FFP), Essential Frailty Toolset, Lawton-Brody, and Katz Index. Malnutrition was measured using the Mini Nutritional Assessment (MNA-LF) and Controlling Nutritional Status. Outcomes of interest were 30-day and one-year mortality. RESULTS: The prevalence of frailty ranged from 6.4% to 65.7% and malnutrition from 5.9% to 10.5%, depending on the evaluation tool. Both parameters were associated with higher levels of cortisol and parathormone as well as lower levels of IGF-1, testosterone, DHEAS, and c-reactive protein. Malnutrition was associated with increased 30-day mortality, and both frailty and malnutrition with increased one-year mortality. In a multivariate analysis, malnutrition measured by the MNA-LF (OR: 2.32 [95%CI: 1.19-4.53], p = 0.01) and frailty as assessed by the FFP (OR: 1.42 [95%CI: 1.02-1.96], p = 0.03) were independent predictors of one-year mortality. CONCLUSION: The prevalence of frailty and malnutrition varies significantly depending on the assessment tool. Both syndromes share common endocrinological alterations. Frailty and malnutrition are independent risk factors for mortality after AVR.


Subject(s)
Aortic Valve Stenosis , Frailty , Malnutrition , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Endocrine System , Frail Elderly , Frailty/diagnosis , Humans , Malnutrition/diagnosis , Risk Factors , Treatment Outcome
6.
Heart Vessels ; 37(10): 1801-1807, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35505257

ABSTRACT

The left axillary artery is an attractive alternative access route for transcatheter aortic valve replacement (TAVR) and may provide better outcomes compared to other alternatives. Nevertheless, there remain concerns about vascular complications, lack of compressibility, and thorax-related complications. Between March 2019 and March 2021, 13 patients underwent transaxillary TAVR for severe aortic stenosis at the University Hospital Bonn. The puncture was performed with a puncture at the distal segment of the axillary artery through the axilla, with additional femoral access for applying a safety wire inside the axillary artery. Device success was defined according to the VARC 2 criteria. The study participants were advanced in age (77 ± 9 years old), and 54% were female, with an intermediate risk for surgery (STS risk score 4.7 ± 2.0%). The average diameter of the distal segment of the axillary artery was 5.8 ± 1.0 mm (i.e., the puncture site) and 7.6 ± 0.9 mm for the proximal axillary artery. Device success was achieved in all patients. 30-day major adverse cardiac and cerebrovascular events were 0%. With complete percutaneous management, stent-graft implantation was performed at the puncture site in 38.5% of patients. Minor bleeding was successfully managed with manual compression. Moreover, no thorax-related complications, hematomas, or nerve injuries were observed. Percutaneous trans-axilla TAVR was found to be feasible and safe. This modified approach may mitigate the risk of bleeding and serious complications in the thorax and be less invasive than surgical alternatives.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Axilla/surgery , Female , Femoral Artery/surgery , Hemorrhage/etiology , Humans , Male , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
7.
Echocardiography ; 39(1): 65-73, 2022 01.
Article in English | MEDLINE | ID: mdl-34921426

ABSTRACT

OBJECTIVE: To investigate the rate and clinical impact of a persisting iatrogenic atrial septal defect (iASD) after percutaneous left atrial appendage occlusion (LAAO). BACKGROUND: Percutaneous LAAO is an alternative to oral anticoagulation (OAC) for the prevention of ischemic stroke and systemic embolism in patients with atrial fibrillation (AF). Data regarding incidence and persistence of iASD after LAAO procedures and its clinical relevance is scarce. METHODS: We retrospectively analyzed 144 patients that underwent LAAO at our center between 2009 and 2020 who had at least one follow-up including transesophageal echocardiography (TEE). Baseline clinical, procedural data and echocardiographic characteristics in patients with and without evidence of an iASD were compared. We furthermore determined the rate of iASD persistence over time and evaluated outcomes of patients with and without spontaneous iASD closure. RESULTS: After a median of 92 days (IQR 75-108 days) after LAAO, 50 patients (50/144, 34.7%) showed evidence of an iASD. Patients with iASD had higher CHADS-VASc-scores (4.9±1.5 vs 4.2±1.2, p = 0.03), larger left atrial volumes (80.5±30.5 ml vs 67.1±19.7 ml, p = 0.01) and were more likely to have relevant mitral regurgitation (≥° II) (46.0% vs 12.3%, p = 0.001). LAAO procedures took longer (50.1±24.3 vs 41.1±17.8 min, p = 0.06) in patients with a persisting iASD. Furthermore, larger device sizes were implanted (24.3±3.4 mm vs 22.1±2.8 mm, p = 0.03). The presence of an iASD had no impact on RV dysfunction, thromboembolism or mortality. Spontaneous closure of an iASD was documented in 52.0% (26/50). Hereby, similar risk factors were identified for the persistence of an iASD in follow-up.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Heart Septal Defects, Atrial , Stroke , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Cardiac Catheterization/methods , Echocardiography, Transesophageal , Heart Septal Defects, Atrial/epidemiology , Heart Septal Defects, Atrial/surgery , Humans , Iatrogenic Disease/epidemiology , Incidence , Retrospective Studies , Treatment Outcome
8.
Artif Organs ; 43(7): 656-665, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30589446

ABSTRACT

Endoluminal left atrial appendage occlusion is an emerging therapy to treat patients suffering from atrial fibrillation with contraindications against oral anticoagulation. Different occlusion devices have been introduced into the clinical setting while comparative studies between the devices are sparse. This in vitro study compares several endoluminal left atrial appendage occlusion systems regarding 2 mechanical properties: radial (RF) and tug force (TF). Seven different occluder systems of various sizes (24 in total) underwent testing throughout their recommended sizing range. RF was measured in a commercial RF tester. TF was assessed according to a recently published bench test. RF increased with compression of the devices: The LAmbre 2228 device exerted the highest RF (8.6 N) at maximum compression of 16 mm. The lowest RF of 0.1 N was exhibited by the 27 mm Occlutech occluder at minimal compression. The highest TFs were exerted by the WaveCrest devices at maximum compression with 4.6 and 3.6 N for the 22 mm and the 27 mm device, respectively. The lowest TFs were measured for the first-generation Occlutech devices, particularly for the 24 mm device with 1.1 N at maximum compression and 0.4 N at minimum compression. A strong positive correlation was found between the number of hooks per millimeter circumference of an occluder and its tug force (r = 0.87, P < 0.01). The analysis revealed device stability to be more dependent on anchoring structures than on RF. The wide range of mechanical properties makes comparison of current LAA occluders difficult and emphasizes the need for standardized preclinical testing to prompt clinical compatibility.


Subject(s)
Atrial Appendage/surgery , Septal Occluder Device , Atrial Fibrillation/surgery , Humans , Mechanical Phenomena , Prosthesis Design , Prosthesis Implantation
10.
Clin Res Cardiol ; 113(1): 58-67, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37178161

ABSTRACT

BACKGROUND: Malnutrition is associated with adverse outcomes in patients with aortic stenosis. The Triglycerides × Total Cholesterol × Body Weight Index (TCBI) is a simple scoring model to evaluate the status of nutrition. However, the prognostic relevance of this index in patients undergoing transcatheter aortic valve replacement (TAVR) is unknown. This study aimed to evaluate the association of the TCBI with clinical outcomes in patients undergoing TAVR. METHODS: A total of 1377 patients undergoing TAVR were evaluated in this study. The TCBI was calculated by the formula; triglyceride (mg/dL) × total cholesterol (mg/dL) × body weight (kg)/1000. The primary outcome was all-cause mortality within 3 years. RESULTS: Patients with a low TCBI, based on a cut-off value of 985.3, were more likely to have elevated right atrial pressure (p = 0.04), elevated right ventricular pressure (p < 0.01), right ventricular systolic dysfunction (p < 0.01), tricuspid regurgitation ≥ moderate (p < 0.01). Patients with a low TCBI had a higher cumulative 3-year all-cause (42.3% vs. 31.6%, p < 0.01; adjusted HR 1.36, 95% CI 1.05-1.77, p = 0.02) and non-cardiovascular mortality (15.5% vs. 9.1%, p < 0.01; adjusted HR 1.95, 95% CI 1.22-3.13, p < 0.01) compared to those with a high TCBI. Adding a low TCBI to EuroSCORE II improved the predictive value for 3-year all-cause mortality (net reclassification improvement, 0.179, p < 0.01; integrated discrimination improvement, 0.005, p = 0.01). CONCLUSION: Patients with a low TCBI were more likely to have right-sided heart overload and exhibited an increased risk of 3-year mortality. The TCBI may provide additional information for risk stratification in patients undergoing TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Nutrition Assessment , Treatment Outcome , Aortic Valve Stenosis/surgery , Body Weight , Cholesterol , Aortic Valve/surgery , Severity of Illness Index , Risk Factors
11.
Clin Res Cardiol ; 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39256220

ABSTRACT

BACKGROUND AND OBJECTIVE: Transcatheter aortic valve replacement (TAVR) is an established treatment option for patients with symptomatic severe aortic stenosis across all stages of surgical risk. Rapid pacing during the procedure and the risk for the occurrence of conduction disturbances after TAVR requires the pre-interventional insertion of a temporary pacemaker (TP). However, this approach poses risks, including the risk of infection. For this reason, the following study aimed to investigate microbial growth on temporary pacemaker leads and its association with outcome post-TAVR and to identify associated pathogens and related risk factors. METHODS: A prospective study was conducted including 344 patients undergoing TAVR at the Heart Centre Bonn. Of these, 97 patients did not require TP leads as they already had permanent pacemakers; this group was considered as comparison group. The TP leads of the remaining 247 patients were removed, sonicated, and cultured to investigate bacterial growth over a period of 14 days. Finally, we compared patients without microbial growth (n = 184) and patients with microbial growth (n = 63). The primary endpoint of the study was 30-day all-cause mortality, secondary endpoints were periprocedural infections, the length of the postprocedural hospital stay, 30-day major vascular complications and the 30-day stroke rate. RESULTS: The majority of cases (74.5%) showed no bacterial growth. In the remaining cases (25.5%), diverse microorganisms were identified, mostly non-pathogenic bacteria. The statistical analysis revealed no significant differences between groups according to microbial growth in terms of 30-day mortality (p = 0.446), postprocedural hospital stay (p = 0.401), periprocedural infections (p = 0.434), 30-day major vascular complications (p = 1.0), and 30-day stroke rate (p = 1.0). Notably, the timing of sheath insertion was significantly associated with microbial growth; sheath placement more than 2 days prior to the procedure was associated with a significantly higher risk of microbial growth (OR: 2.1; 95% CI 1.1-4.3) (p = 0.030). CONCLUSIONS: The presence of temporary leads does not significantly impact clinical outcomes, irrespective of bacterial growth on the lead. However, the timing and duration of sheath placement plays a crucial role in contamination incidence. Thus, temporary leads/sheaths should be placed shortly before the procedure and removed promptly to reduce the risk of contamination/infection.

12.
J Am Heart Assoc ; 13(3): e031997, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38240198

ABSTRACT

BACKGROUND: Aortic stenosis has pathophysiological similarities with atherosclerosis, including the deposition of cholesterol-containing lipoproteins. The resulting cholesterol crystals activate the NLRP3 (NOD-like receptor protein 3) inflammasome, leading to inflammation and cardiovascular diseases. We aimed to investigate the cholesterol crystal dissolution rate (CCDR) of serum in patients with aortic stenosis and to assess the prognostic value of this biomarker. METHODS AND RESULTS: The study included 348 patients with aortic stenosis undergoing transcatheter aortic valve replacement. The CCDR was measured using flow cytometry to enumerate cholesterol crystals that were added to a serum solution, at baseline and after 2 hours of incubation. Based on the median CCDR, the cohort was stratified into high and low cholesterol crystal dissolvers. The incidence of the primary end point, a composite of 1-year all-cause mortality and major vascular complication, was significantly lower in the high CCDR group (7.3 per 100 person-years) compared with the low CCDR group (17.0 per 100 person-years, P=0.01). This was mainly driven by a lower 1-year mortality rate in patients with a high CCDR (7.3 versus 15.1 per 100 person-years, P=0.04). Unplanned endovascular interventions were significantly less frequent in high cholesterol crystal dissolvers (12.8 versus 22.6 per 100 person-years, P=0.04). Although low-density lipoprotein cholesterol levels were comparable in both groups (101.8±37.3 mg/dL versus 97.9±37.6 mg/dL, P=0.35), only patients with a low CCDR showed a benefit from statin treatment. In multivariate analysis, low CCDR (hazard ratio, 2.21 [95% CI, 0.99-4.92], P=0.04) was significantly associated with 1-year mortality. CONCLUSIONS: The CCDR is a novel biomarker associated with outcome in patients with aortic stenosis undergoing transcatheter aortic valve replacement. It may provide new insights into patients' anti-inflammatory capacity and additional prognostic information beyond classic risk assessment.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Treatment Outcome , Risk Assessment , Biomarkers , Aortic Valve/surgery , Risk Factors
13.
J Thorac Imaging ; 39(4): 224-231, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38389116

ABSTRACT

PURPOSE: Inflammatory changes in epicardial (EAT) and pericardial adipose tissue (PAT) are associated with increased overall cardiovascular risk. Using routine, preinterventional cardiac CT data, we examined the predictive value of quantity and quality of EAT and PAT for outcome after transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Cardiac CT data of 1197 patients who underwent TAVR at the in-house heart center between 2011 and 2020 were retrospectively analyzed. The amount and density of EAT and PAT were quantified from single-slice CT images at the level of the aortic valve. Using established risk scores and known independent risk factors, a clinical benchmark model (BMI, Chronic kidney disease stage, EuroSCORE 2, STS Prom, year of intervention) for outcome prediction (2-year mortality) after TAVR was established. Subsequently, we tested whether the additional inclusion of area and density values of EAT and PAT in the clinical benchmark model improved prediction. For this purpose, the cohort was divided into a training (n=798) and a test cohort (n=399). RESULTS: Within the 2-year follow-up, 264 patients died. In the training cohort, particularly the addition of EAT density to the clinical benchmark model showed a significant association with outcome (hazard ratio 1.04, 95% CI: 1.01-1.07; P =0.013). In the test cohort, the outcome prediction of the clinical benchmark model was also significantly improved with the inclusion of EAT density (c-statistic: 0.589 vs. 0.628; P =0.026). CONCLUSIONS: EAT density as a surrogate marker of EAT inflammation was associated with 2-year mortality after TAVR and may improve outcome prediction independent of established risk parameters.


Subject(s)
Adipose Tissue , Aortic Valve Stenosis , Inflammation , Pericardium , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Female , Male , Adipose Tissue/diagnostic imaging , Pericardium/diagnostic imaging , Retrospective Studies , Aged, 80 and over , Tomography, X-Ray Computed/methods , Inflammation/diagnostic imaging , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Predictive Value of Tests , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Risk Factors , Epicardial Adipose Tissue
14.
Sci Rep ; 13(1): 14181, 2023 08 30.
Article in English | MEDLINE | ID: mdl-37648792

ABSTRACT

Cerebral embolization is a known complication of transcatheter aortic valve implantation (TAVI) but the effect of the procedure on the ocular perfusion is currently unclear. Thus, we investigated post-procedural morphologic and perfusion changes of the retina and choroid, using optical coherence tomography angiography (OCTA) and color fundus photography (CFP) in a prospective cohort study. Ophthalmic examinations were conducted pre- and post-TAVI. OCTA images were analyzed quantitatively based on vessel density and skeleton density of the superficial and deep retinal plexus as well as the signal intensity and flow deficits in the choriocapillaris. CFP images were assessed for presence of acute retinal ischemia, optic nerve swelling, vessel emboli, hemorrhages and cotton wool spots. Data was analyzed using linear mixed models. Twenty patients (9 women; 11 men) at a mean age of 81 ± 6 years were included. Pre- and post-interventional ocular imaging data were available for 32 eyes. The analysis revealed a significant impairment of the choriocapillaris perfusion after TAVI with an increased proportion of flow deficits (p = 0.044). When controlling for blood pressure, the average size of choriocapillaris flow voids was significantly increased (systolic and diastolic, p = 0.039 and 0.029). Qualitatively, focal areas of retinal ischemia were detected on OCTA in 33% of participants. Silent emboli or cotton wool spots were identified on CFP in 21%. Our findings indicate a reduced choroidal perfusion as well as areas of retinal ischemia and embolization in a considerable proportion of patients following TAVI. Pending confirmation in a larger sample, these complications merit monitoring as well as inclusion in consent procedures for TAVI.


Subject(s)
Papilledema , Transcatheter Aortic Valve Replacement , Male , Humans , Female , Aged , Aged, 80 and over , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Face , Retina , Ischemia
15.
Cardiovasc Revasc Med ; 49: 42-46, 2023 04.
Article in English | MEDLINE | ID: mdl-36609100

ABSTRACT

BACKGROUND: Recently, the Chronic Kidney Disease-Epidemiology Collaboration working group has published new formulas for race-independent estimation of glomerular filtration rate (GFR). We investigated the old and new eGFR equations in patients transcatheter aortic valve implantation (TAVI). METHODS: We conducted a retrospective analysis based on the data from a prospective registry of patients who underwent TAVI from January 2008 to May 2019. The primary endpoint was 30-day mortality after TAVI, and the secondary endpoints included one- and three-year mortality. RESULTS: In total, 1792 patients undergoing TAVI were included in the present analysis. The thirty-day mortality was 4.6 % (95 % CI 3.8-5.7 %), and the one- and three-year mortality were 17.5 % (95 % CI 15.7-19.4 %) and 34.4 % (95 % CI 32.0-37.0 %). After the application of the new eGFR formula, 12.0 % of patients were reclassified within the GFR category in CKD, while 13.2 % of patients were reclassified within the GFR categories of the EuroSCORE II. Hazard ratios for 30-day, one-year, and three-year mortality increased after introduction of the new creatine-based eq. (1.51, 1.52, 1.49 vs. 1.87, 1.79, 1.74, respectively). Compared to the old equation, the new eGFR <60 ml/min/1.73 m2 had a better discrimination ability for the 30-day mortality (Harell's C: 0.563 (95 % CI 0.518-0.608) vs, 0.583 (95 % CI 0.546-0.636); delta Harell's C, 0.031 ± 0.022, p < 0.001). Similar findings were consistently observed in the cystatin creatinine-based equations. CONCLUSIONS: The application of the new race-independent estimators of GFR results in the reassessment of renal function in a significant proportion of TAVI patients and may influence the risk stratification of this population.


Subject(s)
Aortic Valve Stenosis , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Risk Assessment , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/therapy , Glomerular Filtration Rate , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Creatinine
16.
Hellenic J Cardiol ; 74: 1-7, 2023.
Article in English | MEDLINE | ID: mdl-37119968

ABSTRACT

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Retrospective Studies , Ventricular Function, Left , Stroke Volume , Heart Failure/complications , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Ventricular Remodeling , Severity of Illness Index
17.
Int J Cardiol Heart Vasc ; 46: 101205, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37122629

ABSTRACT

Background: Vascular injury and bleeding complications remain frequent after transcatheter aortic valve replacement (TAVR). Whether the access-site of preprocedural coronary angiography (CAG) affects TAVR-related complications is not known. The aim of this study was to evaluate the impact of transradial (TRA) versus transfemoral access (TFA) for preprocedural CAG on outcomes in patients undergoing subsequent TAVR. Methods: The study cohort included 1002 patients undergoing transfemoral TAVR, of whom 39.4% (395/1002) had undergone radial and 60.6% (607/1002) femoral access for pre-TAVR CAG. The primary endpoint was a composite of 30-day mortality and major vascular complications after TAVR. Key secondary endpoints included VARC-3-defined complications. Results: The primary endpoint occurred less frequently in patients with prior TRA (3.3%) as compared to patients with prior TFA (6.3%, p = 0.04), which was mainly driven by significantly lower rates of major vascular complications (0.8% vs 2.5%, p = 0.05). Moreover, incidences of periprocedural access-related vascular injury and unplanned endovascular interventions were lower in TRA patients (13.2% vs 18.0%, p = 0.05). The rate of major bleeding tended to be lower in the TRA (1.5%) as compared to the TFA group (3.5%) but was not significantly different (p = 0.07). Moreover, the rate of life-threatening bleeding was comparable between both groups (0.5% vs 0.8%, p = 0.71). Conclusion: Transradial access for preprocedural CAG was associated with significantly lower rates of vascular complications following subsequent TAVR as compared to transfemoral access. However, despite the tendency to lower major bleedings with transradial access, no significant association was detectable between the access-site of coronary angiography and TAVR-related bleeding complications.

18.
Clin Cardiol ; 46(1): 67-75, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36259730

ABSTRACT

BACKGROUND: Despite major advances, transcatheter aortic valve replacement (TAVR) is still associated with procedure-specific complications. Although previous studies reported lower bleeding rates in patients receiving protamine for heparin reversal, the optimal protamine-to-heparin dosing ratio is unknown. HYPOTHESIS: The aim of this study was a comparison of two different heparin antagonization regimens for the prevention of bleeding complications after TAVR. METHODS: The study included 1446 patients undergoing TAVR, of whom 623 received partial and 823 full heparin antagonization. The primary endpoint was a composite of 30-day mortality, life-threatening, and major bleeding. Safety endpoints included stroke and myocardial infarction at 30 days. RESULTS: Full antagonization of heparin resulted in lower rates of the primary endpoint as compared to partial heparin reversal (5.6% vs. 10.4%, p < .01), which was mainly driven by lower rates of life-threatening (0.5% vs. 1.6%, p = .05) and major bleeding (3.2% vs. 7.5%, p < .01). Moreover, the incidence of major vascular complications was significantly lower in patients with full heparin reversal (3.5% vs. 7.5%, p < .01). The need for red-blood-cell transfusion was lower in patients receiving full as compared to partial heparin antagonization (10.4% vs. 15.9%, p < .01). No differences were observed in the incidence of stroke and myocardial infarction between patients with full and partial heparin reversal (2.2% vs. 2.6%, p = .73 and 0.2% vs. 0.4%, p = .64, respectively). CONCLUSIONS: Full heparin antagonization resulted in significantly lower rates of life-threatening and major bleeding after TAVR as compared to partial heparin reversal. The occurrence of stroke and myocardial infarction was low and comparable between both groups.


Subject(s)
Aortic Valve Stenosis , Myocardial Infarction , Stroke , Transcatheter Aortic Valve Replacement , Humans , Heparin/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Protamines/adverse effects , Risk Factors , Treatment Outcome , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Stroke/prevention & control , Stroke/chemically induced , Myocardial Infarction/prevention & control , Myocardial Infarction/complications , Aortic Valve/surgery
19.
Hellenic J Cardiol ; 70: 1-9, 2023.
Article in English | MEDLINE | ID: mdl-36538975

ABSTRACT

OBJECTIVE: Several supra-annular self-expanding transcatheter systems are commercially available for transcatheter aortic valve implantation (TAVI). Comparative data in large-scale multicenter studies are scant. METHODS: This study included a total of 5175 patients with severe aortic stenosis undergoing TAVI with the ACURATE neo (n = 1095), Evolut R (n = 3365), or Evolut PRO (n = 715) by a transfemoral approach at five high-volume centers. Propensity score matching resulted in 654 triplets. Outcomes are reported according to the Valve Academic Research Consortium-3 (VARC-3) consensus. RESULTS: Moderate or severe paravalvular regurgitation (PVR) occurred significantly more often in the ACURATE neo group (5.2%) than in the Evolut R (1.8%) and Evolut PRO (3.3%) groups (p = 0.003). The rates of major vascular-/access-related complications (4.6%, 3.8%, and 5.0%; p = 0.56), type 3 or 4 bleeding (3.2%, 2.1%, and 4.1%; p = 0.12), and 30-day mortality (2.4%, 2.6%, and 3.7%; p = 0.40) were comparable. The rate of new permanent pacemaker implantation (PPI) was significantly lower in the ACURATE neo group (9.5%, 17.6%, and 16.8%; p < 0.001). Independent predictors for 2-year survival were a Society of Thoracic Surgeons (STS) risk score ≥5%, diabetes mellitus, a glomerular filtration rate <30 ml/min, baseline mean transvalvular gradient ≤ 30 mm Hg, treating center, and relevant PVR. CONCLUSION: In this multicenter study, TAVI with the ACURATE neo, Evolut R, or Evolut PRO was feasible and safe. The rate of relevant PVR was more frequent after the ACURATE neo implantation, with, however, lower rates of PPI. Two-year survival was mainly driven by baseline comorbidities.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Propensity Score , Prosthesis Design , Treatment Outcome
20.
Cardiovasc Res ; 119(3): 857-866, 2023 05 02.
Article in English | MEDLINE | ID: mdl-35727948

ABSTRACT

AIMS: The present study aims to characterize the genetic risk architecture of bicuspid aortic valve (BAV) disease, the most common congenital heart defect. METHODS AND RESULTS: We carried out a genome-wide association study (GWAS) including 2236 BAV patients and 11 604 controls. This led to the identification of a new risk locus for BAV on chromosome 3q29. The single nucleotide polymorphism rs2550262 was genome-wide significant BAV associated (P = 3.49 × 10-08) and was replicated in an independent case-control sample. The risk locus encodes a deleterious missense variant in MUC4 (p.Ala4821Ser), a gene that is involved in epithelial-to-mesenchymal transformation. Mechanistical studies in zebrafish revealed that loss of Muc4 led to a delay in cardiac valvular development suggesting that loss of MUC4 may also play a role in aortic valve malformation. The GWAS also confirmed previously reported BAV risk loci at PALMD (P = 3.97 × 10-16), GATA4 (P = 1.61 × 10-09), and TEX41 (P = 7.68 × 10-04). In addition, the genetic BAV architecture was examined beyond the single-marker level revealing that a substantial fraction of BAV heritability is polygenic and ∼20% of the observed heritability can be explained by our GWAS data. Furthermore, we used the largest human single-cell atlas for foetal gene expression and show that the transcriptome profile in endothelial cells is a major source contributing to BAV pathology. CONCLUSION: Our study provides a deeper understanding of the genetic risk architecture of BAV formation on the single marker and polygenic level.


Subject(s)
Bicuspid Aortic Valve Disease , Heart Valve Diseases , Animals , Humans , Bicuspid Aortic Valve Disease/metabolism , Bicuspid Aortic Valve Disease/pathology , Aortic Valve/pathology , Heart Valve Diseases/pathology , Genome-Wide Association Study , Zebrafish/genetics , Endothelial Cells/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL