Catheter Cardiovasc Interv ; 92(7): E502-E511, 2018 12 01.
Article in English | MEDLINE | ID: mdl-30079472

ABSTRACT

OBJECTIVES: Based on outcomes of the BIOSOLVE-II study, a novel second generation drug-eluting absorbable metal scaffold gained CE-mark in 2016. The BIOSOLVE-III study aimed to confirm these outcomes and to obtain additional 12-month angiographic data. BACKGROUND: Bioresorbable scaffolds are intended to overcome possible long-term effects of permanent stents such as chronic vessel wall inflammation, stent crushing, and fractures. METHODS: The prospective, multicenter BIOSOLVE-II and BIOSOLVE-III studies enrolled 184 patients with 189 lesions (123 patients in BIOSOLVE-II and 61 patients in BIOSOLVE-III). Primary endpoints were in-segment late lumen loss at 6 months (BIOSOLVE-II) and procedural success (BIOSOLVE-III). RESULTS: Mean patient age was 65.5 ± 10.8 years and mean lesion reference diameter was 2.70 ± 0.43 mm. In BIOSOLVE-III, there were significantly more type B2/C lesions than in BIOSOLVE-II (80.3% versus 43.4%, P < 0.0001) and significantly more moderate-to-severe calcifications (24.2% versus 10.7%, P = 0.014). At 12 months, there was no difference in late lumen loss between the two studies; in the overall population, it was 0.25 ± 0.31 mm in-segment and 0.39 ± 0.34 mm in-scaffold. Target lesion failure occurred in six patients (3.3%) and included two cardiac deaths, one target-vessel myocardial infarction, and three clinically driven target lesion revascularizations. No definite or probable scaffold thrombosis was observed. CONCLUSION: The pooled outcomes of BIOSOLVE-II and BIOSOLVE-III provide further evidence on the safety and performance of a novel drug-eluting absorbable metal scaffold with constant clinical and angiographic performance parameters at 12 months and no definite or probable scaffold thrombosis.


Subject(s)
Absorbable Implants , Coronary Artery Disease/therapy , Coronary Vessels , Drug-Eluting Stents , Metals , Percutaneous Coronary Intervention/instrumentation , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/etiology , Coronary Vessels/diagnostic imaging , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
2.
EuroIntervention ; 13(4): 432-439, 2017 07 20.
Article in English | MEDLINE | ID: mdl-28504239

ABSTRACT

AIMS: We aimed to assess the safety and performance of the DREAMS 2G scaffold up to 24 months post implant. METHODS AND RESULTS: The present study population comprises a total of 184 patients with 189 lesions who were enrolled in the prospective, multicentre BIOSOLVE-II and BIOSOLVE-III trials. Clinical follow-up was scheduled at one, six, 12, 24 and 36 months. The present report includes pooled follow-up data at six months and BIOSOLVE-II data at 24 months. Patients were 65.5±10.8 years old, and lesions were 12.5±5.1 mm long with reference diameters of 2.7±0.4 mm. Procedural success was obtained in 97.8%. At six months, the composite clinical endpoint target lesion failure was 3.3% (95% CI: 1.2-7.1), based on two cardiac deaths (1.1%, one unknown and one not device-related), one target vessel myocardial infarction (0.6%), and three clinically driven target lesion revascularisations (1.7%). For BIOSOLVE-II at 24 months, the target lesion failure rate was 5.9% (95% CI: 2.4-11.8), based on two cardiac deaths (1.7%), one target vessel myocardial infarction (0.9%) and four target lesion revascularisations (3.4%). There was no definite or probable scaffold thrombosis. CONCLUSIONS: The present analysis provides additional evidence on the safety of a drug-eluting absorbable metal scaffold with promising clinical outcomes up to 24 months and absence of definite or probable scaffold thrombosis.


Subject(s)
Absorbable Implants , Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/therapeutic use , Myocardial Infarction/therapy , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/methods , Prospective Studies , Sirolimus/therapeutic use , Treatment Outcome