Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Country/Region as subject
Language
Publication year range
1.
J Nutr ; 148(suppl_2): 1413S-1421S, 2018 08 01.
Article in English | MEDLINE | ID: mdl-31505677

ABSTRACT

OBJECTIVE: We describe the purpose of the Dietary Supplement Ingredient Database (DSID), the statistical methodology underlying online calculators of analytically verified supplement content estimates, and the application and significance of DSID label adjustments in nutritional epidemiology. BACKGROUND AND HISTORY: During dietary supplement (DS) manufacturing, many ingredients are added at higher than declared label amounts, but overages are not standardized among manufacturers. As a result, researchers may underestimate nutrient intakes from DSs. The DSID provides statistical tools on the basis of the results of chemical analysis to convert label claims into analytically predicted ingredient amounts. These adjustments to labels are linked to DS products reported in NHANES. RATIONALE: Tables summarizing the numbers of NHANES DS products with ingredient overages and below label content show the importance of DSID adjustments to labels for accurate intake calculations. RECENT DEVELOPMENTS: We show the differences between analytically based estimates and labeled content for vitamin D, calcium, iodine, caffeine, and omega-3 (n-3) fatty acids and their potential impact on the accuracy of intake assessments in large surveys. Analytical overages >20% of label levels are predicted for several nutrients in 50-99% of multivitamin-mineral products (MVMs) reported in NHANES: for iodine and selenium in adult MVMs, for iodine and vitamins D and E in children's MVMs, and for iodine, chromium, and potassium in nonprescription prenatal MVMs. Predicted overages of 10-20% for calcium can be applied to most MVMs and overages >10% for folic acid in the vast majority of adult and children's MVMs. FUTURE DIRECTIONS: DSID studies are currently evaluating ingredient levels in prescription prenatal MVMs and levels of constituents in botanical DSs. CONCLUSIONS: We estimate that the majority of MVM products reported in NHANES have significant overages for several ingredients. It is important to account for nonlabeled additional nutrient exposure from DSs to better evaluate nutritional status in the United States.


Subject(s)
Databases, Factual , Dietary Supplements/analysis , Dietary Supplements/standards , Food Labeling/standards , Humans , Laboratories , Minerals/administration & dosage , Minerals/analysis , Minerals/standards , Nutrition Surveys , Quality Control , United States , Vitamins/administration & dosage , Vitamins/analysis , Vitamins/standards
2.
J AOAC Int ; 92(2): 680-7, 2009.
Article in English | MEDLINE | ID: mdl-19485230

ABSTRACT

The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.


Subject(s)
Chromatography, High Pressure Liquid/methods , Mass Spectrometry/methods , Vitamins/analysis , Solubility , Tablets , Vitamins/administration & dosage , Water
SELECTION OF CITATIONS
SEARCH DETAIL