Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Country/Region as subject
Language
Publication year range
1.
BMC Infect Dis ; 21(1): 75, 2021 Jan 14.
Article in English | MEDLINE | ID: mdl-33446137

ABSTRACT

BACKGROUND: The elderly population in Hong Kong is rapidly growing, and the need for residential care homes (RCHs) is increasing. The risk of being infected with micro-organisms increases among the frail and the vulnerable elderly population as their immunity system begins to deteriorate. Furthermore, the residents in RCHs are at high risk of healthcare-associated infections (HAIs) due to the confined living environments and individual co-morbidities. In relation to this, infection control practice (ICP) is considered a crucial and effective approach in preventing HAIs. This study aimed to observe the daily ICP of healthcare workers in RCH settings. METHODS: An observational study was conducted to observe daily ICP among healthcare workers in private and subsidized RCHs. Each RCH was separated into different units based on the location (common area and bedroom area) and nature of residents for successive days. The ICP episodes were observed until 200 opportunities in each unit. The ICP episodes were recorded by an electronic tool called "eRub," which is an ICP checklist based on international guidelines. RESULTS: The most frequent observed ICP episodes were hand hygiene (n = 1053), the use of gloves (n = 1053) and respiratory protection (n = 1053). The overall compliance of hand hygiene was poor, with only 15% of participants performing this during the "five moments for hand hygiene." Furthermore, the observations showed that 77.9% improperly performed the use of gloves, and 31.8% failed to wear a mask during the care provision for the elderly. However, the results showed that most healthcare workers can wear the mask in a proper way when they should. Generally, the personal care workers were the worst in terms of hand hygiene and use of gloves compared with the other types of healthcare workers. CONCLUSIONS: Despite the fact that the practice of hand hygiene, the use of gloves, and respiratory protection were the important elements of ICP, overall compliance to these elements was still poor. Personal care workers had the most frequent contact with the residents, but they had the worst compliance rate. Hence, continued monitoring and training among healthcare workers is needed, particularly personal care workers, in this healthcare service setting.


Subject(s)
Cross Infection/prevention & control , Guideline Adherence/statistics & numerical data , Health Facilities , Health Personnel , Homes for the Aged , Infection Control/methods , Nursing Homes , Cross Infection/epidemiology , Gloves, Protective , Hand Disinfection/methods , Hong Kong/epidemiology , Humans , Masks , Practice Guidelines as Topic , Respiratory Protective Devices
2.
Am J Infect Control ; 49(6): 746-752, 2021 06.
Article in English | MEDLINE | ID: mdl-33127437

ABSTRACT

BACKGROUND: The risk of hand recontamination is often neglected after using hand washing facilities, which can increase the spread of pathogens. The study aimed to evaluate the hygienic condition of posthandwashing facilities in public washrooms at different timeslots, particularly those near food courts and restaurants located in shopping malls. METHODS: This observational study was conducted in 12 public washrooms that ranged from low-end, middle-end, to high-end category on 3 different timeslots including baseline, T1 (immediate postcleaning) and T2 (1-hour postcleaning, with counting the footfall). Hand-touch surfaces with a high risk of recontamination after handwashing, which included paper tower dispensers, air drying outlets, and exit door handles, were evaluated by the surface adenosine triphosphate (ATP) bioluminescence method (ATP-value). ATP-values <500 relative light units (RLUs) were considered a good hygiene. Cleaning schedules and footfalls of each sampled washroom were obtained by direct observations. RESULTS: The overall mean ATP value of washroom was 785 RLU (N = 108); the ATP values of female and male washrooms at T2 were 203 and 3,718 RLUs, respectively. The highest ATP value was found on the exit door handles of male washrooms (range = 13-26,695 RLUs, mean = 3,229 RLU). Regarding passed/failed hygiene conditions, there were significant differences in the proportion of exit door handles between genders (P = .018) and timeslots (P = .007) as well as that of paper towel button/screw between timeslots (P= .025). CONCLUSION: Attention should be paid at the exit door handles of male washrooms, where are high risks of cross and re-contamination.


Subject(s)
Hand Disinfection , Hygiene , Adenosine Triphosphate , Colony Count, Microbial , Female , Humans , Luminescent Measurements , Male
SELECTION OF CITATIONS
SEARCH DETAIL