Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
J Lipid Atheroscler ; 13(2): 184-193, 2024 May.
Article in English | MEDLINE | ID: mdl-38826178

ABSTRACT

Objective: Serum hemoglobin (Hb) level affects the viscosity of blood. Several studies have reported that Hb level is associated with adverse cardiovascular outcome. However, there is a paucity of evidence on the association between serum Hb level and the risk of subclinical atherosclerosis. Thus, the objective of this study was to investigate the relationship between Hb level and risk of carotid plaque in a health checkup cohort. Methods: This retrospective study analyzed a total of 3,805 individuals without history of cardiovascular disease (CVD) who underwent carotid ultrasonography (USG) between January 2016 and June 2018. Participants were divided into 4 groups based on Hb quartiles in each of male and female. Carotid plaque score was calculated based on USG reports. Multivariable logistic regression analysis was performed for each index of quartile groups regarding the risk of carotid plaque. Results: Of 3,805 individuals (mean age, 52.62±10.25 years; 2,674 [70.28%] males), mean Hb level was 15.11±0.75 g/dL in male and 13.35±0.74 g/dL in female. When the Q1 group was compared to the Q4, increasing quartile of Hb was associated with the presence of significant carotid plaque (plaque score ≥3) in male (adjusted odds ratio [OR], 1.538; 95% confidence interval [CI], 1.182-2.001; p=0.001) and female (adjusted OR, 1.749; 95% CI, 1.058-2.676; p=0.01). Conclusion: A high Hb level is associated with an increased risk of carotid plaques in individuals without history of CVD. This finding may support the need for early screening of CVD in individuals with high Hb levels.

2.
Circ Cardiovasc Interv ; 17(7): e013585, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38786579

ABSTRACT

BACKGROUND: The efficacy and safety of each third-generation drug-eluting stent with ultrathin struts and advanced polymer technology remain unclear. We investigated the clinical outcomes of percutaneous coronary intervention using the Coroflex ISAR polymer-free sirolimus-eluting stent (SES) or Orsiro biodegradable polymer SES. METHODS: The HOST-IDEA trial (Harmonizing Optimal Strategy for Treatment of Coronary Artery Stenosis-Coronary Intervention With Next-Generation Drug-Eluting Stent Platforms and Abbreviated Dual Antiplatelet Therapy), initially designed with a 2×2 factorial approach, sought to randomize patients undergoing percutaneous coronary intervention based on dual antiplatelet therapy duration (3 versus 12 months) and stent type (Coroflex ISAR versus Orsiro). Despite randomizing 2013 patients for dual antiplatelet therapy duration, the stent arm transitioned to a registry format during the trial. Among these, 328 individuals (16.3%) were randomized for Coroflex ISAR or Orsiro SES, while 1685 (83.7%) underwent percutaneous coronary intervention without stent-type randomization. In this study, the Coroflex ISAR (n=559) and Orsiro groups (n=1449) were matched using a propensity score. The prespecified primary end point was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization at 12 months. RESULTS: The baseline patient and procedural characteristics were well balanced between the Coroflex ISAR and Orsiro groups after propensity score matching (n=559, each group). The Coroflex ISAR group was significantly associated with a higher rate of target lesion failure, mainly driven by clinically driven target lesion revascularization, compared with the Orsiro group (3.4% versus 1.1%; hazard ratio, 3.21 [95% CI, 1.28-8.05]; P=0.01). A higher risk of target lesion failure in the Coroflex ISAR group was consistently observed across various subgroups. The rates of any bleeding (hazard ratio, 0.85 [95% CI, 0.51-1.40]; P=0.52) and major bleeding (hazard ratio, 1.58 [95% CI, 0.61-4.08]; P=0.34) were comparable between the 2 groups. CONCLUSIONS: In this propensity score-matched analysis of the stent arm registry from the HOST-IDEA trial, the Orsiro SES was associated with significantly better outcomes in terms of 1-year target lesion failure, mainly driven by clinically driven target lesion revascularization, than the Coroflex ISAR SES. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02601157.


Subject(s)
Absorbable Implants , Cardiovascular Agents , Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Polymers , Prosthesis Design , Registries , Sirolimus , Humans , Male , Female , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Aged , Middle Aged , Treatment Outcome , Time Factors , Polymers/chemistry , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Risk Factors , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/adverse effects , Sirolimus/administration & dosage , Sirolimus/adverse effects , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Dual Anti-Platelet Therapy , Hemorrhage/chemically induced , Risk Assessment , Coronary Stenosis/therapy , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Prospective Studies , Myocardial Infarction/etiology
SELECTION OF CITATIONS
SEARCH DETAIL