Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Eur Radiol ; 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38189979

ABSTRACT

OBJECTIVES: To investigate intra-patient variability of iodine concentration (IC) between three different dual-energy CT (DECT) platforms and to test different normalization approaches. METHODS: Forty-four patients who underwent portal venous phase abdominal DECT on a dual-source (dsDECT), a rapid kVp switching (rsDECT), and a dual-layer detector platform (dlDECT) during cancer follow-up were retrospectively included. IC in the liver, pancreas, and kidneys and different normalized ICs (NICPV:portal vein; NICAA:abdominal aorta; NICALL:overall iodine load) were compared between the three DECT scanners for each patient. A longitudinal mixed effects analysis was conducted to elucidate the effect of the scanner type, scan order, inter-scan time, and contrast media amount on normalized iodine concentration. RESULTS: Variability of IC was highest in the liver (dsDECT vs. dlDECT 28.96 (14.28-46.87) %, dsDECT vs. rsDECT 29.08 (16.59-62.55) %, rsDECT vs. dlDECT 22.85 (7.52-33.49) %), and lowest in the kidneys (dsDECT vs. dlDECT 15.76 (7.03-26.1) %, dsDECT vs. rsDECT 15.67 (8.86-25.56) %, rsDECT vs. dlDECT 10.92 (4.92-22.79) %). NICALL yielded the best reduction of IC variability throughout all tissues and inter-scanner comparisons, yet did not reduce the variability between dsDECT vs. dlDECT and rsDECT, respectively, in the liver. The scanner type remained a significant determinant for NICALL in the pancreas and the liver (F-values, 12.26 and 23.78; both, p < 0.0001). CONCLUSIONS: We found tissue-specific intra-patient variability of IC across different DECT scanner types. Normalization mitigated variability by reducing physiological fluctuations in iodine distribution. After normalization, the scanner type still had a significant effect on iodine variability in the pancreas and liver. CLINICAL RELEVANCE STATEMENT: Differences in iodine quantification between dual-energy CT scanners can partly be mitigated by normalization, yet remain relevant for specific tissues and inter-scanner comparisons, which should be taken into account at clinical routine imaging. KEY POINTS: • Iodine concentration showed the least variability between scanner types in the kidneys (range 10.92-15.76%) and highest variability in the liver (range 22.85-29.08%). • Normalizing tissue-specific iodine concentrations against the overall iodine load yielded the greatest reduction of variability between scanner types for 2/3 inter-scanner comparisons in the liver and for all (3/3) inter-scanner comparisons in the kidneys and pancreas, respectively. • However, even after normalization, the dual-energy CT scanner type was found to be the factor significantly influencing variability of iodine concentration in the liver and pancreas.

2.
AJR Am J Roentgenol ; 222(5): e2330720, 2024 May.
Article in English | MEDLINE | ID: mdl-38353447

ABSTRACT

BACKGROUND. The 2022 Society of Radiologists in Ultrasound (SRU) consensus conference recommendations for small gallbladder polyps support management that is less aggressive than earlier approaches and may help standardize evaluation of polyps by radiologists. OBJECTIVE. The purpose of the present study was to assess the interreader agreement of radiologists in applying SRU recommendations for management of incidental gallbladder polyps on ultrasound. METHODS. This retrospective study included 105 patients (75 women and 30 men; median age, 51 years) with a gallbladder polyp on ultrasound (without features highly suspicious for invasive or malignant tumor) who underwent cholecystectomy between January 1, 2003, and January 1, 2021. Ten abdominal radiologists independently reviewed ultrasound examinations and, using the SRU recommendations, assessed one polyp per patient to assign risk category (extremely low risk, low risk, or indeterminate risk) and make a possible recommendation for surgical consultation. Five radiologists were considered less experienced (< 5 years of experience), and five were considered more experienced (≥ 5 years of experience). Interreader agreement was evaluated. Polyps were classified pathologically as nonneoplastic or neoplastic. RESULTS. For risk category assignments, interreader agreement was substantial among all readers (k = 0.710), less-experienced readers (k = 0.705), and more-experienced readers (k = 0.692). For surgical consultation recommendations, inter-reader agreement was substantial among all readers (k = 0.795) and more-experienced readers (k = 0.740) and was almost perfect among less-experienced readers (k = 0.811). Of 10 readers, a median of 5.0 (IQR, 2.0-8.0), 4.0 (IQR, 2.0-7.0), and 0.0 (IQR, 0.0-0.0) readers classified polyps as extremely low risk, low risk, and indeterminate risk, respectively. Across readers, the percentage of polyps classified as extremely low risk ranged from 32% to 72%; as low risk, from 24% to 65%; and as indeterminate risk, from 0% to 8%. Of 10 readers, a median of zero change to 0 (IQR, 0.0-1.0) readers recommended surgical consultation; the percentage of polyps receiving a recommendation for surgical consultation ranged from 4% to 22%. Of a total of 105 polyps, 102 were nonneo-plastic and three were neoplastic (all benign). Based on readers' most common assessments for nonneoplastic polyps, the risk category was extremely low risk for 53 polyps, low risk for 48 polyps, and indeterminate risk for one polyp; surgical consultation was recommended for 16 polyps. CONCLUSION. Ten abdominal radiologists showed substantial agreement for polyp risk categorizations and surgical consultation recommendations, although areas of reader variability were identified. CLINICAL IMPACT. The findings support the overall reproducibility of the SRU recommendations, while indicating opportunity for improvement.


Subject(s)
Incidental Findings , Polyps , Ultrasonography , Humans , Female , Male , Middle Aged , Polyps/diagnostic imaging , Polyps/surgery , Retrospective Studies , Ultrasonography/methods , Adult , Gallbladder Diseases/diagnostic imaging , Gallbladder Diseases/surgery , Aged , Observer Variation , Radiologists , Societies, Medical , Consensus , Practice Guidelines as Topic
3.
BMC Pediatr ; 24(1): 252, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622583

ABSTRACT

BACKGROUND: Cystic fibrosis is a chronic genetic disease that can affect the function of the respiratory system. Previous reviews of the effects of respiratory muscle training in people with cystic fibrosis are uncertain and do not consider the effect of age on disease progression. This systematic review aims to determine the effectiveness of respiratory muscle training in the clinical outcomes of children and adolescents with cystic fibrosis. METHODS: Up to July 2023, electronic databases and clinical trial registries were searched. Controlled clinical trials comparing respiratory muscle training with sham intervention or no intervention in children and adolescents with cystic fibrosis. The primary outcomes were respiratory muscle strength, respiratory muscle endurance, lung function, and cough. Secondary outcomes included exercise capacity, quality of life and adverse events. Two review authors independently extracted data and assessed study quality using the Cochrane Risk of Bias Tool 2. The certainty of the evidence was assessed according to the GRADE approach. Meta-analyses where possible; otherwise, take a qualitative approach. RESULTS: Six studies with a total of 151 participants met the inclusion criteria for this review. Two of the six included studies were published in abstract form only, limiting the available information. Four studies were parallel studies and two were cross-over designs. There were significant differences in the methods and quality of the methodology included in the studies. The pooled data showed no difference in respiratory muscle strength, lung function, and exercise capacity between the treatment and control groups. However, subgroup analyses suggest that inspiratory muscle training is beneficial in increasing maximal inspiratory pressure, and qualitative analyses suggest that respiratory muscle training may benefit respiratory muscle endurance without any adverse effects. CONCLUSIONS: This systematic review and meta-analysis indicate that although the level of evidence indicating the benefits of respiratory muscle training is low, its clinical significance suggests that we further study the methodological quality to determine the effectiveness of training. TRIAL REGISTRATION: The protocol for this review was recorded in the International Prospective Register of Systematic Reviews (PROSPERO) under registration number CRD42023441829.


Subject(s)
Cystic Fibrosis , Child , Adolescent , Humans , Cystic Fibrosis/therapy , Quality of Life , Breathing Exercises/methods , Chronic Disease , Respiratory Muscles
4.
Biochem Genet ; 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38864965

ABSTRACT

This study aimed to investigate the underlying mechanism and assess the biological role of long intergenic non-coding RNA (LINCRNA)-p21 in type 2 diabetes mellitus (T2DM). LINC-p21 and miR-335-3p expression levels were evaluated in blood from T2DM patients, healthy individuals, and mouse islet ß-cell line MIN6 cells grown in a high glucose environment. Apoptosis-related proteins, iNOS, and IGF-1 were detected in vitro and in vivo. Bioinformatics was used to predict that miR-335-3p had complementary binding sites to IGF-1, and a dual-luciferase reporter confirmed the targeting link between LINC-p21 and miR-335-3p. LINC-p21 was highly expressed in the T2DM serum and cells, and LINC-p21 was significantly associated with T2DM prognosis. In vitro and in vivo dysfunction of ß-cells was reduced by LINC-p21 knockdown. MiR-335-3p and IGF-1 may be potential targets of LINC-p21 and miR-335-3p, respectively, after the prediction of the target of LINC-p21 was verified by dual-luciferase assay. Anti-miR-335-3p made LINC-p21 knockdown function again; however, interference of IGF-1 mRNA restored the function of LINC-p21. The miR-335-3p/IGF-1 axis may have a role in the functional protection of pancreatic ß-cells by LINC-p21 silencing, boosting insulin production, and slowing the course of diabetes.

5.
Eur Radiol ; 33(4): 2439-2449, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36350391

ABSTRACT

OBJECTIVE: To quantitatively compare DLIR and ASiR-V with realistic anatomical images. METHODS: CT scans of an anthropomorphic phantom were acquired using three routine protocols (brain, chest, and abdomen) at four dose levels, with images reconstructed at five levels of ASiR-V and three levels of DLIR. Noise power spectrum (NPS) was estimated using a difference image by subtracting two matching images from repeated scans. Using the max-dose FBP reconstruction as the ground truth, the structure similarity index (SSIM) and gradient magnitude (GM) of difference images were evaluated. Image noise magnitude (σ), frequency location of the NPS peak (fpeak), mean SSIM (MSSIM), and mean GM (MGM) were used as quantitative metrics to compare image quality, for each anatomical region, protocol, algorithm, dose level, and slice thickness. RESULTS: Image noise had a strong (R2 > 0.99) power law relationship with dose for all algorithms. For the abdomen and chest, fpeak shifted from 0.3 (FBP) down to 0.15 mm-1 (ASiR-V 100%) with increasing ASiR-V strength but remained 0.3 mm-1 for all DLIR levels. fpeak shifted down for the brain protocol with increasing DLIR levels. Three levels of DLIR produced similar image noise levels as ASiR-V 40%, 80%, and 100%, respectively. DLIR had lower MSSIM but higher MGM than ASiR-V while matching imaging noise. CONCLUSION: Compared to ASiR-V, DLIR presents trade-offs between functionality and fidelity: it has a noise texture closer to FBP and more edge enhancement, but reduced structure similarity. These trade-offs and unique protocol-dependent behaviors of DLIR should be considered during clinical implementation and deployment. KEY POINTS: • DLIR reconstructed images demonstrate closer noise texture and lower structure similarity to FBP while producing equivalent noise levels comparable to ASiR-V. • DLIR has additional edge enhancement as compared to ASiR-V. • DLIR has unique protocol-dependent behaviors that should be considered for clinical implementation.


Subject(s)
Deep Learning , Humans , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Radionuclide Imaging , Algorithms , Image Processing, Computer-Assisted/methods
6.
Molecules ; 28(4)2023 Feb 05.
Article in English | MEDLINE | ID: mdl-36838530

ABSTRACT

In this work, the origins for the spectral difference between two isoflavones, formononetin (F) and ononin (FG), are revealed via a comparison study of the fluorescence molecular structure. The fluorescence enhancement of FG in hot alkaline conditions is reported for the first time. For F, there is almost no fluorescence under acidic conditions, but when the pH is >4.8, its fluorescence begins to increase due to the deprotonation of 7-OH. Under a pH between 9.3 and 12.0, the anionic form of F produces a strong and stable fluorescence. The fluorescence quantum yield (Yf) of F is measured to be 0.042. FG shows only weak fluorescence in aqueous solutions under a wide range of pH until it is placed in hot alkaline solutions, which is attributed to the cleavage reaction of the γ-pyrone ring in FG. The Yf of FG is determined to be 0.020. Based on the fluorescence sensitization methods of F and FG, the quantitative analysis and detection of two substances can be realized. The limit of the detections for F and FG are 2.60 ng·mL-1 and 9.30 ng·mL-1, respectively. The linear detection ranges of F and FG are 11.7~1860 ng·mL-1 and 14.6~2920 ng·mL-1, respectively. Although the structural relationship between F and FG is glycoside and aglycone, under hot alkaline conditions, the final products after the cleavage and hydrolysis reactions are essentially different. The different fluorescence characteristics between F and FG pave a way for further identification and a quantitative analysis of the corresponding components in Chinese herbal medicine.


Subject(s)
Isoflavones , Glucosides
7.
Radiology ; 304(3): 580-589, 2022 09.
Article in English | MEDLINE | ID: mdl-35638928

ABSTRACT

Background Studies have investigated the value of various dual-energy CT (DECT) technologies for determining renal stone composition. However, sparse multivendor comparison data exist. Purpose To compare the performance of four DECT technologies in determining renal stone composition at standard- and low-dose acquisitions. Materials and Methods This was an in vitro phantom study. Seventy-one urinary stones (size: 2.7-14.1 mm) of known chemical composition (51 calcium, four struvite, four cystine, and 12 urate) were placed in a custom-made cylindrical phantom. Consecutive scans with manufacturer-recommended protocols and dose-optimized institutional protocols (up to 80% reduction in volumetric CT dose index) were obtained with rapid kilovolt peak switching DECT (rsDECT) (n = 2), dual-source DECT (n = 2), twin-beam DECT (tbDECT) (n = 1), and dual-layer detector-based CT (dlDECT) (n = 1) scanners. The image data sets were analyzed using effective atomic number and dual-energy ratio indexes of maximally available and comparable spectra. The performance of each combination of scanner technology, method, and acquisition was assessed. Logistic regression models were used to calculate the area under the receiver operating characteristic curve (AUC). Results After image analysis, all scanners except tbDECT had an AUC greater than 0.95 in at least one acquisition in distinguishing urate from other stones. All DECT techniques were able to help differentiate calcium oxalate monohydrate stones with moderate accuracy (AUC: 0.70-0.83), and brushite was differentiated from urate with AUC greater than 0.99. There was no correlation between performance and acquisition with dose-optimized and/or vendor-recommended settings. Conclusion All four dual-energy CT (DECT) technologies enabled accurate determination of stone composition at standard- and low-dose acquisitions; however, performance varied based on the scanner parameters, DECT technique, and stone type. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Ringl and Apfaltrer in this issue.


Subject(s)
Kidney Calculi , Radiography, Dual-Energy Scanned Projection , Humans , Kidney Calculi/diagnostic imaging , Phantoms, Imaging , Technology , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods , Uric Acid/analysis
8.
AJR Am J Roentgenol ; 219(4): 614-623, 2022 10.
Article in English | MEDLINE | ID: mdl-35441533

ABSTRACT

BACKGROUND. Prior studies have provided mixed results for the ability to replace true unenhanced (TUE) images with virtual unenhanced (VUE) images when characterizing renal lesions by dual-energy CT (DECT). Detector-based dual-layer DECT (dlDECT) systems may optimize performance of VUE images for this purpose. OBJECTIVE. The purpose of this article was to compare dual-phase dlDECT examinations evaluated using VUE and TUE images in differentiating cystic and solid renal masses. METHODS. This retrospective study included 110 patients (mean age, 64.3 ± 11.8 years; 46 women, 64 men) who underwent renal-mass protocol dlDECT between July 2018 and February 2022. TUE, VUE, and nephrographic phase image sets were reconstructed. Lesions were diagnosed as solid masses by histopathology or MRI. Lesions were diagnosed as cysts by composite criteria reflecting findings from MRI, ultrasound, and the TUE and nephrographic phase images of the dlDECT examinations. One radiologist measured lesions' attenuation on all dlDECT image sets. Lesion characterization was compared between use of VUE and TUE images, including when considering enhancement of 20 HU or greater to indicate presence of a solid mass. RESULTS. The analysis included 219 lesions (33 solid masses; 186 cysts [132 simple, 20 septate, 34 hyperattenuating]). TUE and VUE attenuation were significantly different for solid masses (33.4 ± 7.1 HU vs 35.4 ± 8.6 HU, p = .002), simple cysts (10.8 ± 5.6 HU vs 7.1 ± 8.1 HU, p < .001), and hyperattenuating cysts (56.3 ± 21.0 HU vs 47.6 ± 16.3 HU, p < .001), but not septate cysts (13.6 ± 8.1 HU vs 14.0 ± 6.8 HU, p = .79). Frequency of enhancement 20 HU or greater when using TUE and VUE images was 90.9% and 90.9% in solid masses, 0.0% and 9.1% in simple cysts, 15.0% and 10.0% in septate cysts, and 11.8% and 38.2% in hyperattenuating cysts. All solid lesions were concordant in terms of enhancement 20 HU or greater when using TUE and VUE images. Twelve simple cysts and nine hyperattenuating cysts showed enhancement of 20 HU or greater when using VUE but not TUE images. CONCLUSION. Use of VUE images reliably detected enhancement in solid masses. However, VUE images underestimated attenuation of simple and hyperattenuating cysts, leading to false-positive findings of enhancement by such lesions. CLINICAL IMPACT. The findings do not support replacement of TUE acquisitions with VUE images when characterizing renal lesions by dlDECT.


Subject(s)
Cysts , Radiography, Dual-Energy Scanned Projection , Aged , Contrast Media , Female , Humans , Image Enhancement , Kidney , Male , Middle Aged , Radiography, Dual-Energy Scanned Projection/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
9.
AJR Am J Roentgenol ; 218(4): 746-755, 2022 04.
Article in English | MEDLINE | ID: mdl-34668387

ABSTRACT

BACKGROUND. Clinical use of the dual-energy CT (DECT) iodine quantification technique is hindered by between-platform (i.e., across different manufacturers) variability in iodine concentration (IC) values, particularly at low iodine levels. OBJECTIVE. The purpose of this study was to develop in an anthropomorphic phantom a method for reducing between-platform variability in quantification of low iodine content levels using DECT and to evaluate the method's performance in patients undergoing serial clinical DECT examinations on different platforms. METHODS. An anthropomorphic phantom in three body sizes, incorporating varied lesion types and scanning conditions, was imaged with three distinct DECT implementations from different manufacturers at varying radiation exposures. A cross-platform iodine quantification model for correcting between-platform variability at low iodine content was developed using the phantom data. The model was tested in a retrospective series of 30 patients (20 men, 10 women; median age, 62 years) who each underwent three serial contrast-enhanced DECT examinations of the abdomen and pelvis (90 scans total) for routine oncology surveillance using the same three DECT platforms as in the phantom. Estimated accuracy of phantom IC values was summarized using root-mean-square error (RMSE) relative to known IC. Between-platform variability in patients was summarized using root-mean-square deviation (RMSD). RMSE and RMSD were compared between platform-based IC (ICPB) and cross-platform IC (ICCP). ICPB was normalized to aorta and portal vein. RESULTS. In the phantom study, mean RMSE of ICPB across platforms and other experimental conditions was 0.65 ± 0.18 mg I/mL compared with 0.40 ± 0.08 mg I/mL for ICCP (38% decrease in mean RMSE; p < .05). Intrapatient between-platform variability across serial DECT examinations was higher for ICPB than ICCP (RMSD, 97% vs 88%; p < .001). Between-platform variability was not reduced by normalization of ICPB to aorta (RMSD, 97% vs 101%; p = .12) or portal vein (RMSD, 97% vs 97%; p = .81). CONCLUSION. The developed cross-platform method significantly decreased between-platform variability occurring at low iodine content with platform-based DECT iodine quantification. CLINICAL IMPACT. With further validation, the cross-platform method, which has been implemented as a web-based app, may expand clinical use of DECT iodine quantification, yielding meaningful IC values that reflect tissue biologic viability or treatment response in patients who undergo serial examinations on different platforms.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Abdomen , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Radiography, Dual-Energy Scanned Projection/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
10.
Molecules ; 27(15)2022 Jul 22.
Article in English | MEDLINE | ID: mdl-35897862

ABSTRACT

Chelerythrine (CH) and ethoxychelerythrine (ECH) are chemical reference substances for quality control of Chinese herbal medicines, and ECH is the dihydrogen derivative of CH. In this study, their fluorescence and absorption spectra, as well as their structural changes in different protic solvents were compared. It was observed that their emission fluorescence spectra in methanol were almost the same (both emitted at 400 nm), which may be attributed to the nucleophilic and exchange reactions of CH and ECH with methanol molecules with the common product of 6-methoxy-5,6-dihydrochelerythrine (MCH). When diluted with water, MCH was converted into CH, which mainly existed in the form of positively charged CH+ under acidic and near-neutral conditions with the fluorescence emission at 550 nm. With the increase of pH value of the aqueous solution, CH+ converted to 6-hydroxy-5,6-dihydrochelerythrine (CHOH) with the fluorescence emission at 410 nm. The fluorescence quantum yields of MCH and CHOH were 0.13 and 0.15, respectively, and both the fluorescence intensities were much stronger than that of CH+. It is concluded that CH and ECH can substitute each other in the same protic solvent, which was further verified by high-performance liquid chromatography. This study will help in the investigation of structural changes of benzophenanthridine alkaloids and will provide the possibility for the mutual substitution of standard substances in relevant drug testing.


Subject(s)
Methanol , Water , Benzophenanthridines , Chromatography, High Pressure Liquid , Methanol/chemistry , Solvents/chemistry , Spectrometry, Fluorescence
11.
Zhongguo Dang Dai Er Ke Za Zhi ; 24(4): 366-371, 2022 Apr 15.
Article in Zh | MEDLINE | ID: mdl-35527409

ABSTRACT

OBJECTIVES: To investigate the influencing factors for the quality of bowel preparation before colonoscopy in children and the association of the interval from the last administration of laxative to the start of colonoscopy (shortly referred to as waiting time) with the quality of bowel preparation. METHODS: A retrospective analysis was performed for the children who were admitted to the Department of Gastroenterology, Children's Hospital of Nanjing Medical University, from January to November 2020, and received bowel preparation with polyethylene glycol electrolyte powder combined with diet control before colonoscopy. According to the score of Boston bowel preparation scale, they were divided into two groups: adequate bowel preparation group (n=337) and inadequate bowel preparation group (n=30). Related data were collected from the children in both groups, including general information, possible influencing factors for the quality of bowel preparation, adverse reactions associated with bowel preparation, duration of colonoscopy, and postoperative diagnosis. Univariate and multivariate analyses were used to explore the influencing factors for the quality of bowel preparation. RESULTS: The univariate analysis showed that age, body weight, and waiting time were associated with inadequate bowel preparation (P<0.05). The multivariate analysis showed that older age (OR=2.155, 95%CI: 1.087-4.273, P=0.028) and longer waiting time (OR=1.559, 95% CI: 1.191-2.041, P=0.001) were independent risk factors for inadequate bowel preparation. The receiver operating characteristic (ROC) curve analysis showed that the cut-off value of waiting time was 5.5 hours in determining whether bowel preparation was adequate or not, with a sensitivity of 90.0%, a specificity of 50.7%, and an area under the ROC curve of 0.708. After grouping based on waiting time, it was found that the incidence rate of inadequate bowel preparation in the ≥5.5 hours group was significantly higher than that in the <5.5 hours group [14.0% (27/193) vs 1.7% (3/174), P<0.001]. CONCLUSIONS: For children who use polyethylene glycol electrolyte powder combined with diet control for bowel preparation, older age is an independent risk factor for inadequate bowel preparation before colonoscopy, which may be associated with an insufficient dose of polyethylene glycol in older children. Longer waiting time is also an independent risk factor for inadequate bowel preparation, and it is recommended that the waiting time should not exceed 5.5 hours.


Subject(s)
Cathartics , Colonoscopy , Child , Diet , Electrolytes , Humans , Polyethylene Glycols/adverse effects , Powders , Retrospective Studies
12.
Eur Radiol ; 31(12): 9240-9249, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34110426

ABSTRACT

OBJECTIVES: The accuracy of virtual unenhanced (VUE) images has been extensively investigated, yet data on their longitudinal reproducibility is limited. The study purpose was to evaluate the longitudinal reproducibility of VUE attenuation measurements on three different dual-energy CT (DECT) scanner types. METHODS: A total of 137 patients with repeated abdominal DECT either on a rapid kV switching (rsDECT; n = 46), a dual-layer detector (dlDECT; n = 43), or a dual-source scanner (dsDECT; n = 48) were retrospectively included. Attenuation was measured on VUE and corresponding contrast-enhanced images in the liver, spleen, kidneys, aorta, portal vein, and fat. Longitudinal reproducibility was evaluated by calculating the absolute inter-scan differences (HU) and the inter-scan variation (%). Measurement pairs with differences ≤ 10 HU were considered reproducible. Influence of contrast-enhanced attenuation on VUE reproducibility was analyzed using linear regression. RESULTS: The scanner-specific cohorts showed similar age (p-range: 0.35-0.99), sex (p-range: 0.68-1), body weight (p-range: 0.26-0.87), body diameter (p-range: 0.34-0.76), and inter-scan time (p-range: 0.52-0.83). In total, 94.9% of VUE measurements were reproducible for rsDECT, 93.8% for dlDECT, and 90.6% for dsDECT. Overall inter-scan variation was lowest in fat (4.0 (1.7-8.2)%) and highest in tissues with high contrast enhancement: the aorta (13.3 (4.6-21.3)%), portal vein (10.8 (5.7-19.8)%), and kidneys (10.7 (3.9-18.0)%). Significant differences in inter-scan variation were found between the scanner types for the aorta, portal vein, kidneys, and spleen. Inter-scan differences in contrast-enhanced attenuation significantly influenced inter-scan differences in VUE attenuation (p < 0.001; t-ratio: 4.34). CONCLUSIONS: Longitudinal reproducibility of VUE attenuation was high for all scanners, yet inter-scan variation of VUE attenuation was influenced by contrast enhancement, showing greatest magnitude and discrepancy between scanner types in vessels and the kidneys. KEY POINTS: • We found that 94.9% of attenuation measurements on virtual unenhanced images were reproducible for rapid kV switching DECT, 93.8% for dual-layer detector DECT, and 90.6% for dual-source DECT. • Inter-scan variation of attenuation in virtual unenhanced images was comparable between the three scanner types in the liver and fat, whereas inter-scan variation in the spleen, kidneys, portal vein, and aorta showed significant differences between scanner types (p < 0.05). • Inter-scan attenuation differences in contrast-enhanced images significantly influenced inter-scan differences in virtual unenhanced attenuation (p < 0.001, t-ratio: 4.34), suggesting a residual impact of contrast enhancement differences between examinations.


Subject(s)
Radiography, Dual-Energy Scanned Projection , Contrast Media , Humans , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
13.
Eur Radiol ; 31(7): 4438-4451, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33443600

ABSTRACT

OBJECTIVES: To investigate inter-scan and inter-scanner variation of iodine concentration (IC) and attenuation in virtual monoenergetic images at 65 keV (HU65keV) in patients with repeated abdominal examinations on dual-source (dsDECT), rapid kV switching (rsDECT), and dual-layer detector DECT (dlDECT). METHODS: We retrospectively included 131 patients who underwent two abdominal DECT examinations on the same scanner (dsDECT: n = 46, rsDECT: n = 45, dlDECT: n = 40). IC and HU65keV were measured by placing regions of interest in the liver, spleen, kidneys, aorta, portal vein, and inferior vena cava. Overall IC and HU65keV for each scanner, their inter-scan differences and proportional variation were calculated and compared between scanner types. RESULTS: The three scanner-specific cohorts showed similar weight, body diameter, age, sex, and contrast media injection parameters as well as inter-scan differences hereof (p range: 0.23-0.99). Absolute inter-scan differences of HU65keV and IC were comparable between scanners (p range: 0.08-1.0). Overall inter-scan variation was significantly higher in IC than HU65keV (p < 0.05). For the liver, rsDECT showed significantly lower inter-scan variation of IC compared to dsDECT/dlDECT (p = 0.005/0.01), while for the spleen, this difference was only significant compared to dsDECT (p = 0.015). Normalizing IC of the liver to the portal vein and of the spleen to the aorta did not significantly reduce inter-scan variation (p = 0.97 and 0.50). CONCLUSIONS: Iodine measurements across different DECT scanners show inter-scan variation which is higher compared to variation of attenuation values. Inter-scanner differences in longitudinal variation and overall iodine concentration depend on the scanner pairs and organs assessed and should be acknowledged in clinical and scientific DECT applications. KEY POINTS: • All scanner types showed comparable inter-scan variation of attenuation, while for iodine, the rapid kV switching DECT showed lower variability in the liver and spleen. • Iodine concentration showed higher inter-scan variation than attenuation measurements; normalization to vessels did not significantly improve inter-scan reproducibility of iodine concentration in parenchymal organs. • Differences between the three scanner types regarding overall iodine concentration and attenuation obtained from both timepoints were within the range of average intra-patient, inter-scan differences for most assessed organs and vessels.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Contrast Media , Humans , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
14.
Eur Radiol ; 31(11): 8342-8353, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33893535

ABSTRACT

OBJECTIVES: To investigate the image quality and perception of a sinogram-based deep learning image reconstruction (DLIR) algorithm for single-energy abdominal CT compared to standard-of-care strength of ASIR-V. METHODS: In this retrospective study, 50 patients (62% F; 56.74 ± 17.05 years) underwent portal venous phase. Four reconstructions (ASIR-V at 40%, and DLIR at three strengths: low (DLIR-L), medium (DLIR-M), and high (DLIR-H)) were generated. Qualitative and quantitative image quality analysis was performed on the 200 image datasets. Qualitative scores were obtained for image noise, contrast, small structure visibility, sharpness, and artifact by three blinded radiologists on a 5-point scale (1, excellent; 5, very poor). Radiologists also indicated image preference on a 3-point scale (1, most preferred; 3, least preferred). Quantitative assessment was performed by measuring image noise and contrast-to-noise ratio (CNR). RESULTS: DLIR had better image quality scores compared to ASIR-V. Scores on DLIR-H for noise (1.40 ± 0.53), contrast (1.41 ± 0.55), small structure visibility (1.51 ± 0.61), and sharpness (1.60 ± 0.54) were the best (p < 0.05) followed by DLIR-M (1.85 ± 0.52, 1.66 ± 0.57, 1.69 ± 0.59, 1.68 ± 0.46), DLIR-L (2.29 ± 0.58, 1.96 ± 0.61, 1.90 ± 0.65, 1.86 ± 0.46), and ASIR-V (2.86 ± 0.67, 2.55 ± 0.58, 2.34 ± 0.66, 2.01 ± 0.36). Ratings for artifacts were similar for all reconstructions (p > 0.05). DLIRs did not influence subjective textural perceptions and were preferred over ASIR-V from the beginning. All DLIRs had a higher CNR (26.38-102.30%) and lower noise (20.64-48.77%) than ASIR-V. DLIR-H had the best objective scores. CONCLUSION: Sinogram-based deep learning image reconstructions were preferred over iterative reconstruction subjectively and objectively due to improved image quality and lower noise, even in large patients. Use in clinical routine may allow for radiation dose reduction. KEY POINTS: • Deep learning image reconstructions (DLIRs) have a higher contrast-to-noise ratio compared to medium-strength hybrid iterative reconstruction techniques. • DLIR may be advantageous in patients with large body habitus due to a lower image noise. • DLIR can enable further optimization of radiation doses used in abdominal CT.


Subject(s)
Deep Learning , Algorithms , Humans , Image Processing, Computer-Assisted , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Tomography, X-Ray Computed
15.
Molecules ; 21(1): 77, 2016 Jan 11.
Article in English | MEDLINE | ID: mdl-26760995

ABSTRACT

Acute respiratory distress syndrome (ARDS),which is inflammatory disorder of the lung, which is caused by pneumonia, aspiration of gastric contents, trauma and sepsis, results in widespread lung inflammation and increased pulmonary vascular permeability. Its pathogenesis is complicated and the mortality is high. Thus, there is a tremendous need for new therapies. We have reported that HJB-1, a 17-hydroxy-jolkinolide B derivative, exhibited strong anti-inflammatory effects in vitro. In this study, we investigated its impacts on LPS-induced ARDS mice. We found that HJB-1 significantly alleviated LPS-induced pulmonary histological alterations, inflammatory cells infiltration, lung edema, as well as the generation of inflammatory cytokines TNF-α, IL-1ß and IL-6 in BALF. In addition, HJB-1 markedly suppressed LPS-induced IκB-α degradation, nuclear accumulation of NF-κB p65 subunit and MAPK phosphorylation. These results suggested that HJB-1 improved LPS-induced ARDS by suppressing LPS-induced NF-κB and MAPK activation.


Subject(s)
Anti-Inflammatory Agents/pharmacology , Diterpenes/pharmacology , Lung/drug effects , Pulmonary Edema/drug therapy , Respiratory Distress Syndrome/drug therapy , Animals , Anti-Inflammatory Agents/isolation & purification , Bronchoalveolar Lavage Fluid/chemistry , Disease Models, Animal , Diterpenes/isolation & purification , Drugs, Chinese Herbal , Enzyme Activation/drug effects , I-kappa B Kinase/antagonists & inhibitors , I-kappa B Kinase/metabolism , Injections, Intraperitoneal , Interleukin-1beta/antagonists & inhibitors , Interleukin-1beta/biosynthesis , Interleukin-1beta/immunology , Interleukin-6/antagonists & inhibitors , Interleukin-6/biosynthesis , Interleukin-6/immunology , Lipopolysaccharides , Lung/metabolism , Lung/pathology , Mice , Mitogen-Activated Protein Kinase Kinases/antagonists & inhibitors , Mitogen-Activated Protein Kinase Kinases/metabolism , Phosphorylation/drug effects , Pulmonary Edema/chemically induced , Pulmonary Edema/metabolism , Pulmonary Edema/pathology , Respiratory Distress Syndrome/chemically induced , Respiratory Distress Syndrome/metabolism , Respiratory Distress Syndrome/pathology , Tumor Necrosis Factor-alpha/antagonists & inhibitors , Tumor Necrosis Factor-alpha/biosynthesis , Tumor Necrosis Factor-alpha/immunology
16.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(4): 1001-6, 2016 Apr.
Article in Zh | MEDLINE | ID: mdl-30048097

ABSTRACT

Photovoltaic power generation is one of the best ways to utilize solar energy, but the cost of electricity is very high. To reduce the cost of photovoltaic power generation, in this paper, a type of planar luminescent solar concentrator waveguides based on Lumogen F Red 305 (LR305) dye with each size of 50 mm×50 mm×5 mm was proposed with radical polymerization method. The optical properties and photo-electricity outputs of the waveguides were characterized.

17.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(4): 1007-12, 2016 Apr.
Article in Zh | MEDLINE | ID: mdl-30048098

ABSTRACT

Flavanone derivatives are important active ingredients of natural medicine, so the synthesis of these compounds is one of the research hotspots of organic synthesis. Nevertheless, there is little research on fluorescence properties of these compounds up to now. Fluorescence properties of flavanone and 6 kinds of hydroxyl derivatives are studied in this paper. It is found that aqueous solutions of flavanone (FV), 7-hydroxyflavanone (7HF) and 6-hydroxyflavanone (6HF) have fluorescence, but aqueous solutions of 2'-hydroxyflavanone (2'HF), 4'-hydroxyflavanone (4'HF), naringenin and pinocembrin basically have no fluorescence. In three dimensional fluorescence spectra, excitation wavelengths λex of FV are located at 235, 265 and 340 nm, emission wavelength λem is at 386 nm; λex of 7HF are at 230, 276 and 315 nm, λem is at 391 nm; λex of 6HF are at 260 and 356 nm, em is at 482 nm. Influences of pH on fluorescence of FV, 7HF and 6HF are studied, and the reasons of pH affects on fluorescence are discussed from the viewpoint of molecular structure. The UV-absorption spectra of 7HF and 6HF at different pH are studied, and the proton ionization constants (pKa) of 7HF and 6HF are determined respectively to be 7.26±0.05 and 9.90±0.02, by a pH-absorption method. Influences of solvent (methanol) on fluorescence of FV, 7HF and 6HF are studied, and find that the fluorescence of FV and 7HF in methanol are weaker than that in water, but the fluorescence of 6HF in methanol is much stronger. In ordered media (SDS, CTAB and ß-CD), fluorescence of FV and 7HF decreased than that in water, but the fluorescence of 6HF enhanced in the media of ß-CD or CTAB. Using quinine sulfate or L-tryptophane as reference, fluorescence quantum yields of FV and 7HF aqueous solutions are measured to be 0.057 and 0.012, respectively; fluorescence quantum yields of 6HF in methanol or in aqueous solution containing 1.62 mg·mL-1 ß-CD are measured to be 0.064 or 0.012, respectively.

18.
Int J Mol Sci ; 16(12): 29496-507, 2015 Dec 10.
Article in English | MEDLINE | ID: mdl-26690415

ABSTRACT

Calycosin, an isoflavonoid phytoestrogen, isolated from Radix Astragali, was reported to possess anti-tumor, anti-inflammation, and osteogenic properties, but its impact on osteoclast differentiation remains unclear. In this study, we examined the effects of calycosin on osteoclastogenesis induced by RANKL. The results showed that calycosin significantly inhibited RANKL-induced osteoclast formation from primary bone marrow macrophages (BMMs). Calycosin also dose-dependently suppressed the formation of bone resorption pits by mature osteoclasts. In addition, the expression of osteoclatogenesis-related genes, including cathepsin K (CtsK), tartrate-resistant acid phosphatase (TRAP), and MMP-9, was significantly inhibited by calycosin. Furthermore, the results indicated that calycosin down-regulated the expression levels of NFATc1 and c-Fos through suppressing the activation of NF-κB and MAPKs. Our results indicate that calycosin has an inhibitory role in the bone loss by preventing osteoclast formation, as well as its bone resorptive activity. Therefore, calycosin may be useful as a therapeutic reagent for bone loss-associated diseases.


Subject(s)
Isoflavones/pharmacology , Mitogen-Activated Protein Kinases/metabolism , NF-kappa B/metabolism , Osteoclasts/physiology , RANK Ligand/physiology , Animals , Bone Resorption , Cell Differentiation/drug effects , Cells, Cultured , Gene Expression , MAP Kinase Signaling System , Macrophages/metabolism , Male , Mice, Inbred C57BL , NFATC Transcription Factors/genetics , NFATC Transcription Factors/metabolism , Osteoclasts/drug effects , Phosphorylation , Protein Processing, Post-Translational , Proto-Oncogene Proteins c-fos/genetics , Proto-Oncogene Proteins c-fos/metabolism , Transcriptional Activation
19.
Discov Oncol ; 15(1): 245, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38922489

ABSTRACT

LOXL2, an enzyme belonging to the LOX family, facilitates the cross-linking of extracellular matrix (ECM) elements. However, the roles of the LOXL2 gene in mechanisms of oncogenesis and tumor development have not been clearly defined. In this pan-cancer study, we examined the notable disparity in LOXL2 expression at the mRNA and protein levels among various cancer types and elucidated its interconnected roles in tumor progression, mutational profile, immune response, and cellular senescence. Apart from investigating the hyperexpression of LOXL2 being related to poorer prognosis in different types of tumors, this study also unveiled noteworthy connections between LOXL2 and genetic mutations, infiltration of tumor immune cells, and genes in immune checkpoint pathways. Further analysis revealed the participation of LOXL2 in multiple pathways related to cancer extracellular matrix remodeling and cellular senescence. Moreover, our investigation uncovered that the knockdown and inhibition of LOXL2 significantly attenuated the proliferation and migration of PC-9 and HCC-LM3 cells. The knock-down and inhibition of LOXL2 enhanced cellular senescence in lung and liver cancer cells, as confirmed by SA-ß-Gal staining and quantitative RT-PCR analyses. This comprehensive analysis offers valuable insights on the functions of LOXL2 in different types of cancer and its role in regulating the senescence of cancer cells.

20.
Tissue Cell ; 88: 102345, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38471267

ABSTRACT

BACKGROUND: Adiponectin (APN) has exhibited ameliorating effects on non-alcoholic fatty liver disease (NAFLD). This study investigates the roles of APN and its regulatory molecules in hepatic stellate cell (HSC) activation and the progression of NAFLD. METHODS: Mice were subjected to a high-fat diet (HFD) to establish NAFLD models. Liver tissue was examined for lipid metabolism, fibrosis, and inflammation. Mouse 3T3-L1 adipocytes were exposed to palmitic acid (PA) to mimic a high-fat environment. The conditioned medium (CM) from adipocytes was collected for the culture of isolated mouse HSCs. Gain- or loss-of-function studies of APN, nuclear receptor subfamily 2 group F member 2 (NR2F2), and STIP1 homology and U-box containing protein 1 (STUB1) were performed to analyze their roles in NAFLD and HSC activation in vivo and in vitro. RESULTS: APN expression was poorly expressed in HFD-fed mice and PA-treated 3T3-L1 adipocytes, which was attributed to the transcription inhibition mediated by NR2F2. Silencing of NR2F2 restored the APN expression, ameliorating liver steatosis, fibrosis, and inflammatory cytokine infiltration in mouse livers and reducing HSC activation. Similarly, the NR2F2 silencing condition reduced HSC activation in vitro. However, these effects were counteracted by artificial APN silencing. STUB1 facilitated the ubiquitination and protein degradation of NR2F2, and its upregulation mitigated NAFLD-like symptoms in mice and HSC activation, effects reversed by the NR2F2 overexpression. CONCLUSION: This study highlights the role of STUB1 in reducing HSC activation and alleviating NAFLD by attenuating NR2F2-mediated transcriptional repression of APN.


Subject(s)
3T3-L1 Cells , Adiponectin , Hepatic Stellate Cells , Non-alcoholic Fatty Liver Disease , Ubiquitin-Protein Ligases , Ubiquitination , Animals , Non-alcoholic Fatty Liver Disease/metabolism , Non-alcoholic Fatty Liver Disease/pathology , Mice , Hepatic Stellate Cells/metabolism , Adiponectin/metabolism , Ubiquitin-Protein Ligases/metabolism , Ubiquitin-Protein Ligases/genetics , Male , Mice, Inbred C57BL , Proteolysis/drug effects , Diet, High-Fat/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL