ABSTRACT
Background There are currently no evidence-based guidelines for the management of enlarged mediastinal lymph nodes found on lung cancer screening (LCS) CT scans. Purpose To assess the frequency and clinical significance of enlarged mediastinal lymph nodes on the initial LCS CT scans in National Lung Screening Trial (NLST) participants. Materials and Methods A retrospective review of the NLST database identified all CT trial participants with at least one enlarged (≥1.0 cm) mediastinal lymph node identified by site readers on initial CT scans. Each study was reviewed independently by two thoracic radiologists to measure the two largest nodes and to record morphologic characteristics. Scans with extensively calcified mediastinal lymph nodes or nodes measuring less than 1 cm were excluded. Frequency and time to lung cancer diagnosis, lung cancer stage, and histologic findings were compared between NLST participants with and without lymphadenopathy. Results Of the 26 722 NLST participants, 422 (1.6%) had enlarged noncalcified mediastinal lymph nodes on the initial LCS CT scan. Mediastinal lymphadenopathy was associated with an increase in lung cancer cases (72 of 422 participants [17.1%; 95% CI: 13.6, 21.0] vs 1017 of 26 300 [3.9%; 95% CI: 3.6, 4.1]; P < .001), earlier diagnosis (restricted mean survival time ± standard error, 2285 days ± 44 vs 2611 days ± 2; P < .001), the presence of lung nodules (P < .001), advanced stage at presentation (22 of 72 participants [31%] with cancer at stage IIIA vs 410 of 1017 [40.3%] at stage IA; P < .001), and increased mortality (P < .001). The majority of participants with lung cancers in the LCS group with mediastinal lymphadenopathy were detected at initial LCS CT (50 of 422 participants [11.8%; 95% CI: 8.9, 15.3] vs T1-T7, 22 of 422 [5.3%; 95% CI: 3.3, 7.8]; P < .001). There was no association between mediastinal lymphadenopathy and lung cancer histologic findings, CT appearance, or location of lung nodules (P > .05 based on unadjusted pairwise association analyses). Conclusion Noncalcified mediastinal lymphadenopathy in the low-dose lung cancer screening study sample was associated with an increase in lung cancer, an earlier diagnosis, more advanced-stage disease, and increased mortality. More aggressive treatment of these patients appears warranted. © RSNA, 2021 Online supplemental material is available for this article. See also the editorials by McLoud and by Mascalchi and Zompatori in this issue.
Subject(s)
Lung Neoplasms/pathology , Lymphadenopathy/diagnostic imaging , Mediastinum , Tomography, X-Ray Computed , Aged , Female , Humans , Male , Middle Aged , Neoplasm Staging , Retrospective StudiesABSTRACT
ABSTRACT: Chest computed tomography (CT) is one of the most frequently performed imaging studies. Incidental osseous and articular findings are commonly encountered in chest CTs in daily practice. The spectrum of findings is broad, varying from benign to malignant, and interpretation of these incidental musculoskeletal findings could be challenging for radiologists. In this review, we provide a systematic algorithmic approach for the diagnosis of common articular findings seen on chest CT with recommendations for appropriate follow-up evaluation.
Subject(s)
Thorax , Tomography, X-Ray Computed , Humans , Radiologists , Bone and BonesABSTRACT
OBJECTIVE. The virtual imaging trial is a unique framework that can greatly facilitate the assessment and optimization of imaging methods by emulating the imaging experiment using representative computational models of patients and validated imaging simulators. The purpose of this study was to show how virtual imaging trials can be adapted for imaging studies of coronavirus disease (COVID-19), enabling effective assessment and optimization of CT and radiography acquisitions and analysis tools for reliable imaging and management of COVID-19. MATERIALS AND METHODS. We developed the first computational models of patients with COVID-19 and as a proof of principle showed how they can be combined with imaging simulators for COVID-19 imaging studies. For the body habitus of the models, we used the 4D extended cardiac-torso (XCAT) model that was developed at Duke University. The morphologic features of COVID-19 abnormalities were segmented from 20 CT images of patients who had been confirmed to have COVID-19 and incorporated into XCAT models. Within a given disease area, the texture and material of the lung parenchyma in the XCAT were modified to match the properties observed in the clinical images. To show the utility, three developed COVID-19 computational phantoms were virtually imaged using a scanner-specific CT and radiography simulator. RESULTS. Subjectively, the simulated abnormalities were realistic in terms of shape and texture. Results showed that the contrast-to-noise ratios in the abnormal regions were 1.6, 3.0, and 3.6 for 5-, 25-, and 50-mAs images, respectively. CONCLUSION. The developed toolsets in this study provide the foundation for use of virtual imaging trials in effective assessment and optimization of CT and radiography acquisitions and analysis tools to help manage the COVID-19 pandemic.
Subject(s)
COVID-19/diagnostic imaging , Patient-Specific Modeling , Tomography, X-Ray Computed , Humans , Reproducibility of ResultsABSTRACT
OBJECTIVES: Comprehensive training in ultrasound (US) imaging during radiology residency is crucial if radiologists are expected to maintain a substantial role in this widely used imaging modality. This study aimed to evaluate the current curriculum of US training among radiology residency programs across the country via a nationwide survey. METHODS: A 28-question survey was distributed among all academic radiology departments in the United States and their radiology residents. The survey consisted of 4 sections: general demographic information, training information, clinical competency, and adequacy of training (perspective). The Student t test and 1-way analyses of variance were performed to assess statistical significance. RESULTS: Overall, 256 residents from 32 states completed the questionnaire. Only 114 (45%) residents reported having a dedicated rotation for performing US studies. Although 228 (89%) of trainees believed they received adequate experience for interpreting US studies, only 66 (26%) of them had the same belief about performing them. Only 116 (45%) of the residents were comfortable operating the US machines in their departments. Higher years of residency training, having a dedicated rotation for performing US studies, and having more than 10 hours per year of didactic lectures and/or more than 5 hours per year of case conferences dedicated to US had a positive impact on the residents' clinical competency and perspective (all P < .05). CONCLUSIONS: Most radiology residents do not feel confident in performing US examinations by themselves. However, higher clinical competency was reported in the residents who had dedicated rotations for performing US studies and received more hours of US lectures and case conferences throughout their residency.
Subject(s)
Internship and Residency , Radiology , Clinical Competence , Curriculum , Education, Medical, Graduate , Humans , Radiology/education , Surveys and Questionnaires , United StatesABSTRACT
Cardiac implantable electronic devices (CIEDs) frequently need to be extracted due to infection, hardware failure, and other causes. The extraction of the CIED is typically performed using percutaneous methods. While these procedures are mostly performed without incident there is a small risk of significant complications. Dedicated imaging pre-CEID removal to include the central veins and heart with multidetector computed tomography (MDCT) can be utilized to evaluate the lead course and termination, the integrity of the central veins and cardiac chambers, and identify potential complications that may alter the lead extraction procedure as well as reimplantation of subsequent leads. Indications for preprocedural imaging, the technique of dedicated preprocedural lead extraction MDCT, and the approach to the interpretation of the images is discussed in this review.
Subject(s)
Defibrillators, Implantable , Device Removal , Multidetector Computed Tomography , Pacemaker, Artificial , Device Removal/adverse effects , Humans , Predictive Value of Tests , Treatment OutcomeABSTRACT
The outbreak of coronavirus SARS-COV2 affected more than 180 countries necessitating fast and accurate diagnostic tools. Reverse transcriptase polymerase chain reaction (RT-PCR) has been identified as a gold standard test with Chest CT and Chest Radiography showing promising results as well. However, radiological solutions have not been used extensively for the diagnosis of COVID-19 disease, partly due to radiation risk. This study aimed to provide quantitative comparison of imaging radiation risk versus COVID risk. The analysis was performed in terms of mortality rate per age group. COVID-19 mortality was extracted from epidemiological data across 299, 004 patients published by ISS-Integrated surveillance of COVID-19 in Italy. For radiological risk, the study considered 659 Chest CT performed in adult patients. Organ doses were estimated using a Monte Carlo method and then used to calculate Risk Index that was converted into an upper bound for related mortality rate following NCI-SEER data. COVID-19 mortality showed a rapid rise for ages >30 years old (min: 0.30%; max: 30.20%), whereas only four deaths were reported in the analysed patient cohort for ages <20 years old. The rates decreased for radiation risk across age groups. The median mortality rate across all ages for Chest-CT and Chest-Radiography were 0.007% (min: 0.005%; max: 0.011%) and 0.0003% (min: 0.0002%; max: 0.0004%), respectively. COVID-19, Chest Radiography, and Chest CT mortality rates showed different magnitudes and trends across age groups. In higher ages, the risk of COVID-19 far outweighs that of radiological exams. Based on risk comparison alone, Chest Radiography and CT for COVID-19 care is justified for patients older than 20 and 30 years old, respectively. Notwithstanding other aspects of diagnosis, the present results capture a component of risk consideration associated with the use of imaging for COVID. Once integrated with other diagnostic factors, they may help inform better management of the pandemic.
Subject(s)
COVID-19 , Adult , Humans , Pandemics , RNA, Viral , Radiography, Thoracic , SARS-CoV-2 , Young AdultABSTRACT
Background: Perceived risk and worries of developing cancer are important constructs for cancer prevention. Many studies have investigated the relationship between health behaviors and subjective risk perception. However, factors correlated with lung cancer risk perception and worries in individuals more susceptible to lung cancer have rarely been investigated. Objective: To determine demographic, social, and behavioral determinants of cancer perceived risk and worries and to explore heterogeneities in these associations by the level of lung cancer risk in a nationally representative sample of American adults. Methods: For this cross-sectional study, data came from the Health Information National Trends Survey (HINTS) 2017, which included a 2277 representative sample of American adults. Smoking status, cancer perceived risk, cancer worries, age, gender, race, education, income, and insurance status were measured. We ran structural equation models (SEMs) for data analysis. Results: "Ever smoker" status was associated with higher cancer perceived risk (b = 0.25; 95% CI = 0.05â»0.44, p = 0.013) and worries (b = 0.34, 95% CI = 0.18â»0.50, p < 0.001), suggesting that "ever smokers" experience higher levels of cancer perceived risk and worries regarding cancer, compared to "never smokers". Other factors that correlate with cancer perceived risk and worries were race, age, income, and insurance status. Blacks demonstrated less cancer perceived risk and worry (b = -0.98, 95% CI = -1.37â»0.60, p < 0.001) in both low and high risk lung cancer groups. However, the effects of social determinants (income and insurance status) and age were observed in low but not high risk group. Conclusions: Determinants of cancer perceived risk and worries vary in individuals depending on the level of lung cancer risk. These differences should be considered in clinical practice and policy makings with the goal of improving participation rates in lung cancer screening programs.
Subject(s)
Health Risk Behaviors , Lung Neoplasms/epidemiology , Lung Neoplasms/psychology , Perception , Adult , Cross-Sectional Studies , Demography , Early Detection of Cancer , Female , Humans , Insurance, Health , Lung Neoplasms/prevention & control , Male , Middle Aged , Risk , Smoking/epidemiology , Social Class , Surveys and Questionnaires , United States/epidemiologyABSTRACT
OBJECTIVE: The objective of our study was to determine whether the conventionally used enhancement threshold of 10 HU for assessing tumor viability in treated hepatocellular carcinoma (HCC) lesions is valid. MATERIALS AND METHODS: To distinguish pseudoenhancement from enhancement in a tumor, we used an in vivo model: The attenuation of 54 hepatic cysts during the unenhanced and portal venous phases of MDCT, similar to what may be observed in HCC with central necrosis, was used to determine the threshold for pseudoenhancement. To validate this model, we compared the attenuation value of liver parenchyma in this cohort with that of 22 HCCs during the late arterial phase of enhancement. We tested the effect of this pseudoenhancement on quantifying necrosis in HCC compared with the conventionally used threshold of 10 HU. RESULTS: Values of enhancing HCC tissue on arterial phase MDCT (mean, 121.3 HU) were comparable with normal liver parenchyma on venous phase MDCT (117.3 HU) (p = 0.27). The threshold of 17.1 HU was the best threshold for the detection of pseudoenhancement in cysts (99% accuracy, 100% sensitivity, and 98% specificity). When this threshold was used instead of the conventional threshold of 10 HU, the mean necrosis proportion of treated HCC increased from 34.0% to 42.6% and the mean viable tumor proportion decreased from 66.0% to 57.4%. The quantification of viable HCC tissue based on 10 HU and the quantification of viable HCC tissue based on 17.1 HU were found to be significantly different (p < 0.0001). CONCLUSION: The threshold of 17.1 HU may be the appropriate cutoff for nonenhancement in a necrotic HCC. Use of this threshold may potentially affect how response to therapy is quantified and categorized.
Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Liver/diagnostic imaging , Liver/pathology , Multidetector Computed Tomography , Adult , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/pathology , Carcinoma, Hepatocellular/therapy , Cysts/diagnostic imaging , Cysts/pathology , Female , Humans , Liver Diseases/diagnostic imaging , Liver Diseases/pathology , Liver Neoplasms/pathology , Liver Neoplasms/therapy , Male , Middle Aged , Models, Theoretical , Necrosis/diagnostic imaging , Retrospective Studies , Tissue SurvivalABSTRACT
OBJECTIVE: To evaluate the contribution of iterative reconstruction on image quality of reduced-dose multidetector computed tomography of the thoracic aorta. METHODS: A torso phantom was scanned using two tube potentials (80 and 120 kVp) and five different tube currents (110, 75, 40, 20, and 10 mAs). All images were reconstructed with both filtered back projection (FBP) and iterative reconstruction. Aortic attenuation, image noise within the thoracic aorta, signal-to-noise ratio, and sharpness of the aortic wall were quantified in the phantom for the two reconstruction algorithms. Data were analyzed using paired t test. A value of P < 0.05 was considered significant. RESULTS: The aortic attenuation was similar for FBP and iterative reconstruction (P > 0.05). Image noise level was lower (P < 0.0001), and image sharpness was higher (P = 0.046) with iterative reconstruction. Signal-to-noise ratios were higher with iterative reconstruction compared with those with FBP (P < 0.0001). Signal-to-noise ratio at 80 kVp with iterative reconstruction (9.8 ± 4.4) was similar to the signal-to-noise ratio at 120 kVp with FBP (8.4 ± 3.3) (P = 0.196). CONCLUSIONS: Less image noise and higher image sharpness may be achieved with iterative reconstruction in reduced-dose multidetector computed tomography of the thoracic aorta.
Subject(s)
Aorta, Thoracic/diagnostic imaging , Multidetector Computed Tomography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Algorithms , Humans , Phantoms, Imaging , Radiation Dosage , Signal-To-Noise RatioABSTRACT
PURPOSE: To determine whether asymmetric spermatic cord vessel enhancement (ASE) on contrast-enhanced computed tomography (CECT) indicates scrotal pathology. METHODS: Sixty-one male patients with scrotal symptoms who underwent both scrotal ultrasound (US) and CECT within 24 h were identified through a radiology information system. Twenty-eight emergency department patients who underwent CECT only for unrelated symptoms were included for comparison. Two blinded radiologists independently reviewed each CECT scan for qualitative ASE. These data were compared with US diagnoses, when present. A third blinded radiologist reviewed each CECT scan for quantitative ASE by measuring Hounsfield unit (HU) density ratios. McNemar, Kappa, Student's t test, and ANOVA were used for analysis. RESULTS: Eighty-nine total patients included 28 with CECT only and 61 with CECT and US, of which 41 had abnormal US: 15 acute epididymitis and/or orchitis, 7 testicular neoplasms, 11 varicoceles, and 8 with other pathologies. Twenty patients with normal US and 28 patients with CECT only served as control groups. Identification of ASE agreed with US diagnosis of epididymitis (and/or orchitis) or testicular neoplasm (reader 1: κ = 0.79, reader 2: κ = 0.75) with average 95.5% sensitivity and 88.8% specificity, and no significant difference between readers (p = 0.58). For epididymitis (and/or orchitis) or testicular neoplasm patients, the average ratio of spermatic cord HU density (ipsilateral:contralateral) was significantly different from other patients (4.01 vs. 1.26, p = 0.0025). CONCLUSION: ASE on CECT shows stronger correlation with epididymitis (and/or orchitis) and testicular neoplasm compared with other scrotal pathologies. If discovered on CECT, this should prompt further clinical and/or imaging workup.
Subject(s)
Contrast Media , Epididymitis/diagnostic imaging , Radiographic Image Enhancement/methods , Spermatic Cord/diagnostic imaging , Testicular Neoplasms/diagnostic imaging , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Observer Variation , Reproducibility of Results , Retrospective Studies , Ultrasonography , Young AdultABSTRACT
CONTEXT: The accuracy for determining pancreatic cyst volume with commonly used spherical and ellipsoid methods is unknown. The role of CT volumetry in volumetric assessment of pancreatic cysts needs to be explored. OBJECTIVES: To compare volumes of the pancreatic cysts by CT volumetry, spherical and ellipsoid methods and determine their accuracy by correlating with actual volume as determined by EUS-guided aspiration. Setting This is a retrospective analysis performed at a tertiary care center. Patients Seventy-eight pathologically proven pancreatic cysts evaluated with CT and endoscopic ultrasound (EUS) were included. Design The volume of fourteen cysts that had been fully aspirated by EUS was compared to CT volumetry and the routinely used methods (ellipsoid and spherical volume). Two independent observers measured all cysts using commercially available software to evaluate inter-observer reproducibility for CT volumetry. MAIN OUTCOME MEASURES: The volume of pancreatic cysts as determined by various methods was compared using repeated measures analysis of variance. Bland-Altman plot and intraclass correlation coefficient were used to determine mean difference and correlation between observers and methods. The error was calculated as the percentage of the difference between the CT estimated volumes and the aspirated volume divided by the aspirated one. RESULTS: CT volumetry was comparable to aspirated volume (P=0.396) with very high intraclass correlation (r=0.891, P<0.001) and small mean difference (0.22 mL) and error (8.1%). Mean difference with aspirated volume and error were larger for ellipsoid (0.89 mL, 30.4%; P=0.024) and spherical (1.73 mL, 55.5%; P=0.004) volumes than CT volumetry. There was excellent inter-observer correlation in volumetry of the entire cohort (r=0.997, P<0.001). CONCLUSIONS: CT volumetry is accurate and reproducible. Ellipsoid and spherical volume overestimate the true volume of pancreatic cysts.
Subject(s)
Cystadenocarcinoma, Mucinous/diagnostic imaging , Cystadenoma, Mucinous/diagnostic imaging , Pancreatic Cyst/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Pseudocyst/diagnostic imaging , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Aged, 80 and over , Algorithms , Cystadenocarcinoma, Mucinous/pathology , Cystadenocarcinoma, Mucinous/surgery , Cystadenoma, Mucinous/pathology , Cystadenoma, Mucinous/surgery , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Observer Variation , Pancreatic Cyst/pathology , Pancreatic Cyst/surgery , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/surgery , Pancreatic Pseudocyst/pathology , Pancreatic Pseudocyst/surgery , Reproducibility of Results , Suction , Tumor Burden , Ultrasonography , Young AdultABSTRACT
BACKGROUND: Thoracic aortic aneurysm is one of the most common aorta pathologies worldwide, which is commonly evaluated by computed tomography angiography (CTA). One of the routine methods to improve the image quality of CTA is heart rate reduction prior to study by beta-blockade administration. PURPOSE: To assess the effect of beta-blockade on image quality of the ascending aorta in electrocardiography (ECG)-gated dual-source CTA (DSCTA) images. MATERIAL AND METHODS: In this retrospective study, ECG-gated thoracic aorta CTA images of 40 patients without beta-blocker administration were compared with ECG-gated images of 40 patients with beta-blockade. Images of the aorta were analyzed objectively and subjectively at three levels: sinus of Valsalva (sinus), sinotubular junction (STJ), and mid ascending aorta (MAA). Quantitative sharpness index (SI) and signal-to-noise ratio (SNR) were calculated and two radiologists evaluated the image quality using a 3-point scale. RESULTS: Mean heart rate in beta-blocker and non-beta-blocker groups was 61.7 beats per minute (bpm) (range, 58.1-63.9 bpm) and 72.9 bpm (range, 69.3-84.1 bpm), respectively (P < 0.05). Aorta wall SI, SNR, and subjective grading were comparable between the two groups at all three levels (P > 0.05). CONCLUSION: Beta-blocker premedication may not be necessary for imaging of ascending aorta with ECG-gated DSCTA.
Subject(s)
Adrenergic beta-Antagonists/pharmacology , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Cardiac-Gated Imaging Techniques/methods , Coronary Angiography/drug effects , Electrocardiography/methods , Premedication/methods , Coronary Angiography/methods , Female , Humans , Male , Middle Aged , Observer Variation , Radiographic Image Interpretation, Computer-Assisted/methods , Retrospective StudiesABSTRACT
RATIONALE AND OBJECTIVES: Managing contrast reactions is critical as contrast reactions can be life-threatening and unpredictable. Institutions need an effective system to handle these events. Currently, there is no standard practice for assigning trainees, radiologists, non-radiologist physicians, or other non-physician providers for management of contrast reaction. MATERIALS AND METHODS: The Association of Academic Radiologists (AAR) created a task force to address this gap. The AAR task force reviewed existing practices, studied available literature, and consulted experts related to contrast reaction management. The Society of Chairs of Academic Radiology Departments (SCARD) members were surveyed using a questionnaire focused on staffing strategies for contrast reaction management. RESULTS: The task force found disparities in contrast reactions management across institutions and healthcare providers. There is a lack of standardized protocols for assigning personnel for contrast reaction management. CONCLUSION: The AAR task force suggests developing standardized protocols for contrast reaction management. The protocols should outline clear roles for different healthcare providers involved in these events.
ABSTRACT
PURPOSE: The purpose of this study was to systematically review the reported performances of ChatGPT, identify potential limitations, and explore future directions for its integration, optimization, and ethical considerations in radiology applications. MATERIALS AND METHODS: After a comprehensive review of PubMed, Web of Science, Embase, and Google Scholar databases, a cohort of published studies was identified up to January 1, 2024, utilizing ChatGPT for clinical radiology applications. RESULTS: Out of 861 studies derived, 44 studies evaluated the performance of ChatGPT; among these, 37 (37/44; 84.1%) demonstrated high performance, and seven (7/44; 15.9%) indicated it had a lower performance in providing information on diagnosis and clinical decision support (6/44; 13.6%) and patient communication and educational content (1/44; 2.3%). Twenty-four (24/44; 54.5%) studies reported the proportion of ChatGPT's performance. Among these, 19 (19/24; 79.2%) studies recorded a median accuracy of 70.5%, and in five (5/24; 20.8%) studies, there was a median agreement of 83.6% between ChatGPT outcomes and reference standards [radiologists' decision or guidelines], generally confirming ChatGPT's high accuracy in these studies. Eleven studies compared two recent ChatGPT versions, and in ten (10/11; 90.9%), ChatGPTv4 outperformed v3.5, showing notable enhancements in addressing higher-order thinking questions, better comprehension of radiology terms, and improved accuracy in describing images. Risks and concerns about using ChatGPT included biased responses, limited originality, and the potential for inaccurate information leading to misinformation, hallucinations, improper citations and fake references, cybersecurity vulnerabilities, and patient privacy risks. CONCLUSION: Although ChatGPT's effectiveness has been shown in 84.1% of radiology studies, there are still multiple pitfalls and limitations to address. It is too soon to confirm its complete proficiency and accuracy, and more extensive multicenter studies utilizing diverse datasets and pre-training techniques are required to verify ChatGPT's role in radiology.
Subject(s)
Radiology , Humans , ForecastingABSTRACT
BACKGROUND: To assess changes in bone density and vertebral body height of patients undergoing lung transplant surgery using computed tomography (CT). METHODS: This institutional review board (IRB) approved retrospective observational study enrolled patients with a history of lung transplant who had at least two chest CT scans. Vertebral body bone density (superior, middle, and inferior sections) and height (anterior, middle, and posterior sections) were measured at T1-T12 at baseline and follow up CT scans. Changes in the mean bone density, mean vertebral height, vertebral compression ratio (VBCR), percentage of anterior height compression (PAHC), and percentage of middle height compression (PMHC) were calculated and analyzed. RESULTS: A total of 93 participants with mean age of 58 ± 12.3 years were enrolled. The most common underlying disease that led to lung transplants was interstitial lung diseases (57 %). The inter-scan interval was 34.06 ± 24.8 months. There were significant changes (p-value < 0.05) in bone density at all levels from T3 to T12, with the greatest decline at the T10 level from 163.06 HU to 141.84 HU (p-value < 0.05). The average VBCR decreased from 96.91 to 96.15 (p-value < 0.05). CONCLUSION: Routine chest CT scans demonstrate a gradual decrease in vertebral body bone density over time in lung transplant recipients, along with evident anatomic changes such as vertebral body bone compression. This study shows that utilizing routine chest CT for lung transplant recipients can be regarded as a cost-free tool for assessing the vertebral body bone changes in these patients and potentially aiding in the prevention of complications related to osteoporosis.
Subject(s)
Bone Density , Lung Transplantation , Tomography, X-Ray Computed , Humans , Lung Transplantation/adverse effects , Middle Aged , Female , Male , Tomography, X-Ray Computed/methods , Retrospective Studies , Bone Density/physiology , Vertebral Body/diagnostic imaging , Aged , Adult , Transplant Recipients , Radiography, Thoracic/economics , Radiography, Thoracic/methodsABSTRACT
Acute respiratory distress syndrome (ARDS) has a fibroproliferative phase that may be followed by pulmonary fibrosis. Pulmonary fibrosis following COVID-19 pneumonia has been described at autopsy and following lung transplantation. We hypothesized that protein mediators of tissue remodeling and monocyte chemotaxis are elevated in the plasma and endotracheal aspirates of critically ill patients with COVID-19 who subsequently develop features of pulmonary fibroproliferation. We enrolled COVID-19 patients admitted to the ICU with hypoxemic respiratory failure. (n = 195). Plasma was collected within 24h of ICU admission and at 7d. In mechanically ventilated patients, endotracheal aspirates (ETA) were collected. Protein concentrations were measured by immunoassay. We tested for associations between protein concentrations and respiratory outcomes using logistic regression adjusting for age, sex, treatment with steroids, and APACHE III score. In a subset of patients who had CT scans during hospitalization (n = 75), we tested for associations between protein concentrations and radiographic features of fibroproliferation. Among the entire cohort, plasma IL-6, TNF-α, CCL2, and Amphiregulin levels were significantly associated with in-hospital mortality. In addition, higher plasma concentrations of CCL2, IL-6, TNF-α, Amphiregulin, and CXCL12 were associated with fewer ventilator-free days. We identified 20/75 patients (26%) with features of fibroproliferation. Within 24h of ICU admission, no measured plasma proteins were associated with a fibroproliferative response. However, when measured 96h-128h after admission, Amphiregulin was elevated in those that developed fibroproliferation. ETAs were not correlated with plasma measurements and did not show any association with mortality, ventilator-free days (VFDs), or fibroproliferative response. This cohort study identifies proteins of tissue remodeling and monocyte recruitment are associated with in-hospital mortality, fewer VFDs, and radiographic fibroproliferative response. Measuring changes in these proteins over time may allow for early identification of patients with severe COVID-19 at risk for fibroproliferation.
Subject(s)
COVID-19 , Pulmonary Fibrosis , Humans , COVID-19/mortality , COVID-19/blood , COVID-19/pathology , Male , Female , Middle Aged , Aged , Pulmonary Fibrosis/pathology , Pulmonary Fibrosis/blood , Pulmonary Fibrosis/mortality , Monocytes/metabolism , Hospital Mortality , SARS-CoV-2 , Lung/pathology , Chemotaxis, Leukocyte , ChemotaxisABSTRACT
PURPOSE: Outcome evaluation in ocular adnexal lymphoma (OAL) is based on clinical assessment and conventional volumetric changes in tumor size. The purpose of this retrospective study was to compare if changes in apparent diffusion coefficient (ADC) tumor values obtained by diffusion-weighted MRI corresponded to changes in enhancing tumor volume in the evaluation of early treatment response or failure in patients with OAL. METHODS: A retrospective case series analysis of conventional contrast-enhanced orbital MRI and diffusion-weighted sequences was performed on 8 pathologically confirmed OAL tumors before and after therapy. Mean ADC values and normalized ADC ratios were obtained using a region-of-interest analysis method on enhancing OAL lesions; tumor volumes were calculated using a manual segmentation method. Changes in tumor volume, mean ADC tumor values, and normalized ADC ratios were compared before and after therapy using a Wilcoxon rank-sum test. RESULTS: Overall, a significant difference was found in mean ADC values and normalized ADC ratios within OAL tumors before and after therapy (p < 0.05), irrespective of the type of therapy administered. There was a trend toward decreased mean enhancing tumor volume after therapy (p = 0.161). An increase in ADC values and a decrease in enhancing tumor volume after therapy correlated with a positive treatment response in 7 of 8 tumors; a decrease in ADC values and an increase in enhancing tumor volume after therapy correlated with a negative treatment response in 1 of 8 tumors. CONCLUSIONS: Tracking changes in tumor ADC values after various treatment regimens for OAL may be useful in predicting early treatment response or failure and can provide complementary information that corresponds to conventional volume changes in tumor size. Further validation of these preliminary results in larger prospective randomized trials is needed.
Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Lymphoma/diagnosis , Orbital Neoplasms/diagnosis , Antineoplastic Agents/therapeutic use , Contrast Media , Humans , Lymphoma/therapy , Orbital Neoplasms/therapy , Pilot Projects , Radioimmunotherapy/methods , Regression Analysis , Retrospective StudiesABSTRACT
Purpose of Review: In this study, we planned and carried out a scoping review of the literature to learn how machine learning (ML) has been investigated in cardiovascular imaging (CVI). Recent Findings: During our search, we found numerous studies that developed or utilized existing ML models for segmentation, classification, object detection, generation, and regression applications involving cardiovascular imaging data. We first quantitatively investigated the different aspects of study characteristics, data handling, model development, and performance evaluation in all studies that were included in our review. We then supplemented these findings with a qualitative synthesis to highlight the common themes in the studied literature and provided recommendations to pave the way for upcoming research. Summary: ML is a subfield of artificial intelligence (AI) that enables computers to learn human-like decision-making from data. Due to its novel applications, ML is gaining more and more attention from researchers in the healthcare industry. Cardiovascular imaging is an active area of research in medical imaging with lots of room for incorporating new technologies, like ML. Supplementary Information: The online version contains supplementary material available at 10.1007/s40134-022-00407-8.
ABSTRACT
Background: Prompt interventions prevent adverse events (AE) in hypertrophic cardiomyopathy (HCM). We evaluated the pattern and the predictive role of feature tracking (FT)-cardiac magnetic resonance (CMR) imaging parameters in an HCM population with a normal left ventricular ejection fraction (LVEF) and a low fibrosis burden. Methods: The CMR and clinical data of 170 patients, consisting of 142 HCM (45 ± 15.7 years, 62.7% male) and 28 healthy (42.2 ± 11.26 years, 50% male) subjects, who were enrolled from 2015 to 2020, were evaluated. HCM patients had a normal LVEF with a late gadolinium enhancement (LGE) percentage below 15%. Between-group differences were described, and the potent predictors of AE were determined. A P-value below 0.05 was considered significant. Results: LV global longitudinal, circumferential, and radial strains (GLS, GCS, and GRS, respectively) and the LV myocardial mass index (MMI) were different between the healthy and HCM cases (all Ps < 0.05). Strains were significantly impaired in the HCM patients with a normal MMI. A progressive decrease in LVGLS and a distinct fall in LVGCS were noted with a rise in MMI. AE were predicted by LVGLS, LVGCS, and the LGE percentage, and LVGCS was the single robust predictor (HR, 1.144; 95% CI, 1.080-1.212; P = 0.001). An LVGCS below 16.2% predicted AE with 77% specificity and 58% sensitivity. Conclusions: LV strains were impaired in HCM patients with a normal EF and a low fibrosis burden, even in the presence of a normal MMI. CMR parameters, especially FT-CMR values, predicted AE in our HCM patients.
ABSTRACT
BACKGROUND: The coronary artery calcium score (CACS) indicates cardiovascular health. A concern in this regard is the ionizing radiation from computed tomography (CT). Recent studies have tried to introduce low-dose CT techniques to assess CACS. We aimed to investigate the accuracy of iterative reconstruction (IR) and threshold modification while applying low tube voltage in coronary artery calcium imaging. METHODS: The study population consisted of 107 patients. Each subject underwent an electrocardiogram-gated CT twice, once with a standard voltage of 120 kVp and then a reduced voltage of 80 kVp. The standard filtered back projection (FBP) reconstruction was applied in both voltages. Considering Hounsfield unit (HU) thresholds other than 130 (150, 170, and 190), CACS was calculated using the FBP-reconstructed 80 kVp images. Moreover, the 80 kVp images were reconstructed utilizing IR at different strength levels. CACS was measured in each set of images. The intraclass correlation coefficient (ICC) was used to compare the CACSs. RESULTS: A 64% reduction in the effective dose was observed in the 80 kVp protocol compared to the 120 kVp protocol. Excellent agreement existed between CACS at high-level (strength level = 5) IR in low-kVp images and the standard CACS protocol in scores ≥ 11 (ICC > 0.9 and p < 0.05). Increasing the threshold density to 190 HU in FBP-reconstructed low-kVp images yielded excellent agreement with the standard protocol in scores ≥ 11 (ICC > 0.9 and p < 0.05) and good agreement in score zero (ICC = 0.84 and p = 0.02). CONCLUSIONS: The modification of the density threshold and IR provides an accurate calculation of CACS in low-voltage CT with the potential to decrease patient radiation exposure.