Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
J Cardiovasc Electrophysiol ; 30(9): 1499-1507, 2019 09.
Article in English | MEDLINE | ID: mdl-31199536

ABSTRACT

INTRODUCTION: Autonomic modulation has been used as a therapy to control recurrent ventricular arrhythmia (VA). This study was to explore stellate ganglion block (SGB) effect on cardiac electrophysiologic properties and evaluate the long-term outcome of cardiac sympathetic denervation (CSD) for patients with recurrent VA and structural heart disease (SHD). MATERIALS AND METHODS: Patients who had recurrent VA due to SHD were enrolled prospectively. Electrophysiologic study and ventricular tachycardia (VT) induction were performed before and after left and right SGB. VA burden and long-term outcomes were assessed for a separate patient group who underwent left or bilateral CSD for drug-refractory VA due to SHD. RESULTS: Electrophysiologic study of nine patients showed that baseline mean (SD) corrected sinus node recovery time (cSNRT) increased from 320.4 (73.3) ms to 402.9 (114.2) ms after left and 482.4 (95.7) ms after bilateral SGB (P = .03). SGB did not significantly change P-R, QRS, and Q-T intervals and ventricular effective refractory period, nor did the inducibility of VA. Nineteen patients underwent left (n = 14) or bilateral (n = 5) CSD. CSD reduced VA burden and appropriate ICD therapies from a median (interquartile range) of 2.5 (0.4-11.6) episodes weekly to 0.1 (0.0-2.4) episodes weekly at 6-month follow-up (P = .002). Three-year freedom from orthotopic heart transplant (OHT) and death was 52.6%. New York Heart Association functional class III/IV and VT rate less than 160 beats per minute were predictors of recurrent VA, OHT, and death. CONCLUSION: SGB increased cSNRT without changing heart rate. CSD was more beneficial for patients with mild-to-moderate heart failure and faster VA.


Subject(s)
Cardiomyopathies/complications , Heart/innervation , Stellate Ganglion/surgery , Sympathectomy , Tachycardia, Ventricular/therapy , Action Potentials , Adult , Aged , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Female , Heart Rate , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Stellate Ganglion/physiopathology , Sympathectomy/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome
2.
Heart Rhythm O2 ; 5(3): 158-167, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38560372

ABSTRACT

Background: Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends. Objectives: We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County. Methods: The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed. Results: A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (P < .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years. Conclusion: Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.

3.
medRxiv ; 2023 May 10.
Article in English | MEDLINE | ID: mdl-37214896

ABSTRACT

Background: Cardiovascular implantable electronic devices (CIEDs) such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends. Objectives: Describe trends in noninfectious CIED complications over the past three decades in Olmsted County. Methods: The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966-current. CIED implants between 1988-2018 were determined. Trends in noninfectious complications within 30 days of implant were analyzed. Results: 175 out of 2536 (6.9%) patients who received CIED experienced device complications. 3.8% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.9%), followed by hematoma (2.1%). Complications went up from 1988 to 2005, then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (p<0.01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity score has trended up over the 30 years. Conclusions: Our study describes a real-world trend of CIED complications over three decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.

4.
JACC Clin Electrophysiol ; 8(1): 88-100, 2022 01.
Article in English | MEDLINE | ID: mdl-34454890

ABSTRACT

OBJECTIVES: This study sought to describe trends in cardiovascular implantable electronic device (CIED) insertion over the past 3 decades in Olmsted County. BACKGROUND: Trends in CIED insertion in the United States have not been extensively studied. METHODS: The Rochester Epidemiology Project is a medical records linkage system comprising the records of all residents of Olmsted County from 1966 to the present. CIED insertion between 1988 and 2018 was determined using International Classification of Diseases-Ninth Revision, International Classification of Diseases-10th Revision, and Current Procedural Terminology codes. Age- and sex-adjusted incidence rates, adjusted to the 2010 US White population, were calculated. Trends in incidence over time, across age groups, and between sex are estimated using Poisson regression models. RESULTS: The age- and sex-adjusted incidence of device implants for the study period were as follows: overall CIED: 82.4 (95% CI: 79.2-85.6); permanent pacemaker (PPM): 62.9 (95% CI: 60.0-65.7); implantable cardioverter-defibrillator (ICD): 14.0 (95% CI: 12.6-15.3); and cardiac resynchronization therapy (CRT): 5.6 (95% CI: 4.7-6.4) per 100,000 per year. The overall incidence of CIED insertion increased between 1988 to 1993 and 2000 to 2005 and then decreased between 2000 to 2005 and 2012 to 218 (P < 0.0001). PPM and ICD insertion incidence followed these trends, whereas the incidence of CRT insertion increased between 2000 to 2005 and 2012 to 2018. CIED insertion incidence increased with age (P < 0.0001). CIED insertion incidence was greater in men (116.3 vs 57.3 per 100,000 per year in men vs women; P < 0.0001). The overall survival of CRT recipients improved (P = 0.0044). CONCLUSIONS: The incidence values for PPM and ICD implants are decreasing, while the incidence of CRT implants is increasing. CIEDs are increasingly inserted in the elderly, men, and patients with higher comorbidities.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Pacemaker, Artificial , Aged , Electronics , Female , Humans , Male , Risk Factors , United States/epidemiology
5.
Nat Protoc ; 15(5): 1853-1877, 2020 05.
Article in English | MEDLINE | ID: mdl-32313253

ABSTRACT

neuECG, the simultaneous noninvasive recording of ECG and skin sympathetic nerve activity (SKNA), directly records sympathetic nerve activity over a long period of time. It can be used to measure sympathetic tone in healthy subjects and in subjects with non-cardiovascular diseases. The electrical activity that can be measured on the surface of the skin originates from the heart, the muscle or nerve structures. Because the frequency content of nerve activity falls in a higher frequency range than that of the ECG and myopotential, it is possible to use high-pass or band-pass filtering to specifically isolate the SKNA. neuECG is voltage calibrated and does not require invasive procedures to impale electrodes in nerves and thus has advantages over microneurography. Here, we present a protocol that takes <10 min to set up. The neuECG can be continuously recorded over a 24-h period or longer. We also describe methods to efficiently analyze neuECG from humans using commercially available hardware and software to facilitate adoption of this technology in clinical research.


Subject(s)
Diagnostic Techniques, Neurological , Electrocardiography , Sympathetic Nervous System , Healthy Volunteers , Humans , Skin/innervation
6.
Chin Med J (Engl) ; 132(6): 631-637, 2019 Mar 20.
Article in English | MEDLINE | ID: mdl-30855343

ABSTRACT

BACKGROUND: The comparative outcomes of subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (T-ICD) have not been well studied. The aim of this study was to evaluate the safety and efficacy of currently available S-ICD and T-ICD. METHODS: The study included 86 patients who received an S-ICD and 1:1 matched to those who received single-chamber T-ICD by gender, age, diagnosis, left ventricular ejection fraction (LVEF), and implant year. The clinical outcomes and implant complications were compared between the two groups. RESULTS: The mean age of the 172 patients was 45 years, and 129 (75%) were male. The most common cardiac condition was hypertrophic cardiomyopathy (HCM, 37.8%). The mean LVEF was 50%. At a mean follow-up of 23 months, the appropriate and inappropriate ICD therapy rate were 1.2% vs. 4.7% (χ = 1.854, P = 0.368) and 9.3% vs. 3.5% (χ = 2.428, P = 0.211) in S-ICD and T-ICD groups respectively. There were no significant differences in device-related major and minor complications between the two groups (7.0% vs. 3.5%, χ = 1.055, P = 0.496). The S-ICD group had higher T-wave oversensing than T-ICD group (9.3% vs. 0%, χ = 8.390, P = 0.007). Sixty-five patients had HCM (32 in S-ICD and 33 in T-ICD). The incidence of major complications was not significantly different between the two groups. CONCLUSIONS: The efficacy of an S-ICD is comparable to that of T-ICD, especially in a dominantly HCM patient population. The S-ICD is associated with fewer major complications demanding reoperation.


Subject(s)
Cardiomyopathy, Hypertrophic/therapy , Defibrillators, Implantable , Tachycardia, Ventricular/therapy , Adult , Cardiomyopathy, Hypertrophic/physiopathology , Death, Sudden, Cardiac/prevention & control , Electrocardiography , Female , Humans , Male , Middle Aged , Tachycardia, Ventricular/physiopathology
7.
Heart Rhythm ; 16(11): 1669-1675, 2019 11.
Article in English | MEDLINE | ID: mdl-31201964

ABSTRACT

BACKGROUND: Heightened sympathetic nerve activity is associated with occurrence of ventricular arrhythmia (VA). OBJECTIVE: To investigate the association of skin sympathetic nerve activity (SKNA) and VA occurrence. METHODS: We prospectively enrolled 65 patients with severe cardiomyopathy. Of these, 39 had recent sustained VA episodes (VA-1 group), 11 had intractable VA undergoing sedation with general anesthesia (VA-2 group), and 15 had no known history of VA (VA-Ctrl group). All patients had simultaneous SKNA and electrocardiogram recording. SKNA was assessed using an average value (aSKNA), a variable value (vSKNA), and the number of bursts of SKNA (bSKNA). RESULTS: The VA-1 group had higher aSKNA and vSKNA compared with the VA-Ctrl group (aSKNA: 1.41 ± 0.53 µV vs 0.98 ± 0.41 µV, P = .003; vSKNA: 0.52 ± 0.22 µV vs 0.30 ± 0.16 µV, P < .001) and the VA-2 group (aSKNA: 0.83 ± 0.22 µV, P < .001; vSKNA: 0.23 ± 0.11 µV; P < .001). Although the VA-2 group had more VA episodes than the VA-1 group (median, 5 vs 2; P = .01), their SKNA was the lowest among the 3 groups. Multivariate Cox regression analysis showed that a higher aSKNA at baseline was an independent predictor of lower VA recurrence rate during a 417 ± 279-day follow-up (hazard ratio, 0.325; 95% confidence interval [CI], 0.119-0.883; P = .03). A >15% reduction in aSKNA after therapy was associated with a lower subsequent VA event rate (hazard ratio, 0.222; 95% CI, 0.057-0.864; P = .03). CONCLUSION: Patients with VA had increased SKNA as compared with control. Both SKNA and sustained VA could be suppressed by general anesthesia. The aSKNA at baseline was an independent predictor of VA recurrence.


Subject(s)
Arrhythmias, Cardiac/physiopathology , Cardiomyopathies/physiopathology , Skin/innervation , Sympathetic Nervous System/physiopathology , Ventricular Dysfunction/physiopathology , Aged , Electrocardiography , Female , Humans , Male , Middle Aged , Prospective Studies
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 202: 301-304, 2018 Sep 05.
Article in English | MEDLINE | ID: mdl-29800893

ABSTRACT

In this work, we have designed and synthesized the fluorescent probe 1, which showed a highly selective and sensitive response to Cys over Hcy/GSH in the test. Moreover, the color of probe solution has changed dramatically from colorless to pink with the addition of Cys within 10 min. Meanwhile, the fluorescence intensity exhibited perfectly positive correlation with concentration of Cys from 0 to 200 µM, which offered the important condition for quantitative analysis. Finally, the bioimaging and fluorescence response of probe 1 for fetal calf serum are a powerful safeguard for practical detection of Cys. Therefore, this near-infrared probe will be of great benefit for detecting Cys in the biological systems.


Subject(s)
Cysteine/analysis , Fluorescent Dyes/chemistry , Glutathione/analysis , Homocysteine/analysis , Spectroscopy, Near-Infrared , HeLa Cells , Humans , Imaging, Three-Dimensional , Spectrometry, Fluorescence , Spectrophotometry, Ultraviolet , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL