Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Electrocardiol ; 81: 265-268, 2023.
Article in English | MEDLINE | ID: mdl-37947362

ABSTRACT

A16-year-old female underwent tilt table testing, which resulted positive for reflex vasodepressive syncope. 12­lead ECG during syncope showed T-wave inversion in infero-lateral leads, along with QTc interval increase >100 msec compared to baseline. These abnormalities rapidly disappeared in supine position with resumption of consciousness. Complete cardiac evaluation excluded heart disease. T-wave changes and moderate QTc prolongation are relatively common in young (mainly female) patients undergoing tilt table testing and they appear benign in nature. However, in a minority of cases, on the basis of the clinical context and after an accurate ECG analysis, further examinations may be warranted.


Subject(s)
Electrocardiography , Syncope, Vasovagal , Adolescent , Female , Humans , Electrocardiography/methods , Heart , Syncope/diagnosis , Syncope/etiology , Tilt-Table Test
2.
J Electrocardiol ; 69: 132-135, 2021.
Article in English | MEDLINE | ID: mdl-34717131

ABSTRACT

The term phenocopy indicates a condition that imitates one produced by a gene and is also used for acquired Brugada-like ECG manifestations. Cases of Brugada phenocopies are increasingly reported in literature and an international registry is ongoing. We describe two patients with Hypertrophic Cardiomyopathy (HCM) and Brugada ECG pattern. Both patients carried the same pathogenic splicing mutation in MYBPC3 gene (responsible for HCM) while no genetic mutation associated with Brugada Syndrome was identified. To the best of our knowledge, Brugada ECG pattern has been rarely reported in patients with HCM.


Subject(s)
Brugada Syndrome , Cardiomyopathy, Hypertrophic , Brugada Syndrome/diagnosis , Brugada Syndrome/genetics , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/genetics , Electrocardiography , Humans , Mutation , Phenotype
3.
J Cardiovasc Electrophysiol ; 31(4): 846-853, 2020 04.
Article in English | MEDLINE | ID: mdl-32064713

ABSTRACT

INTRODUCTION: Atrial tachycardia/fibrillation (AT/AF) episodes are common in implantable cardioverter-defibrillator (ICD) recipients and can be undetected by standard single-chamber devices. This study aims to explore whether a single-lead ICD with an atrial dipole (ICD DX; BIOTRONIK SE & Co, Berlin, Germany) could improve the AT/AF diagnosis and management as compared to standard ICD (ICD VR). METHODS AND RESULTS: We selected patients without AT/AF history from the THINGS registry which included consecutive patients implanted with ICD for standard indications. The ICD VR and the ICD DX groups included 236 (62.8%) and 140 (37.2%) patients, respectively, and had no significant differences in baseline characteristics. During a median follow-up of 27 months, there were 7 AT/AF diagnoses in the ICD VR and 18 in the ICD DX group. The 2-year incidence of AT/AF diagnosis was 3.6% (95% confidence interval [CI]: 1.6%-9.6%) for the ICD VR and 11.4% (95% CI: 6.8%-18.9%) for the ICD DX group (adjusted hazard ratio [HR]: 3.85 [95% CI: 1.58-9.41]; P = .003). Initiation of oral anticoagulation (OAC) due to AT/AF diagnosis was reported in 15 patients. The 2-year incidence of OAC onset was 3.6% (95% CI: 1.6%-7.8%) for the ICD VR and 6.3% (95% CI: 3.0%-12.7%) for ICD DX group (adjusted HR: 1.99 [95% CI: 0.72-5.56]; P = .184). CONCLUSION: We observed that atrial sensing capability in single-chamber ICD patients without evidence of atrial arrhythmias at implant is associated with a greater likelihood of detecting AT/AF episodes. The management of these diagnosed arrhythmias often led to clinical interventions, mainly represented by initiation of OAC therapy.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Function , Cardiomyopathies/therapy , Defibrillators, Implantable , Electric Countershock/instrumentation , Electrophysiologic Techniques, Cardiac/instrumentation , Heart Failure/therapy , Tachycardia, Supraventricular/diagnosis , Administration, Oral , Aged , Anti-Arrhythmia Agents/administration & dosage , Anticoagulants/administration & dosage , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Cardiomyopathies/diagnosis , Cardiomyopathies/epidemiology , Cardiomyopathies/physiopathology , Catheter Ablation , Electric Countershock/adverse effects , Female , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/physiopathology , Humans , Incidence , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Registries , Tachycardia, Supraventricular/epidemiology , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/therapy , Time Factors , Treatment Outcome
4.
Europace ; 21(10): 1603-1604, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31353412

ABSTRACT

Despite major therapeutic advances over the last decades, complex supraventricular and ventricular arrhythmias (VAs), particularly in the emergency setting or during revascularization for acute myocardial infarction (AMI), remain an important clinical problem. Although the incidence of VAs has declined in the hospital phase of acute coronary syndromes (ACS), mainly due to prompt revascularization and optimal medical therapy, still up to 6% patients with ACS develop ventricular tachycardia and/or ventricular fibrillation within the first hours of ACS symptoms. Despite sustained VAs being perceived predictors of worse in-hospital outcomes, specific associations between the type of VAs, arrhythmia timing, applied treatment strategies and long-term prognosis in AMI are vague. Atrial fibrillation (AF) is the most common supraventricular tachyarrhythmia that may be asymptomatic and/or may be associated with rapid haemodynamic deterioration requiring immediate treatment. It is estimated that over 20% AMI patients may have a history of AF, whereas the new-onset arrhythmia may occur in 5% patients with ST elevation myocardial infarction. Importantly, patients who were treated with primary percutaneous coronary intervention for AMI and developed AF have higher rates of adverse events and mortality compared with subjects free of arrhythmia. The scope of this position document is to cover the clinical implications and pharmacological/non-pharmacological management of arrhythmias in emergency presentations and during revascularization. Current evidence for clinical relevance of specific types of VAs complicating AMI in relation to arrhythmia timing has been discussed.


Subject(s)
Acute Coronary Syndrome/surgery , Cardiac Resynchronization Therapy/standards , Cardiology , Consensus , Percutaneous Coronary Intervention/standards , Societies, Medical , Tachycardia, Ventricular/therapy , Acute Coronary Syndrome/complications , Europe , Heart Conduction System/physiopathology , Humans , Prognosis , Risk Factors , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology
6.
Pacing Clin Electrophysiol ; 39(3): 250-60, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26643691

ABSTRACT

BACKGROUND: To understand the impact of a quadripolar left ventricular (LV) lead on reverse remodeling and phrenic nerve stimulation (PNS) in congestive heart failure patients treated by cardiac resynchronization therapy at 8-month follow-up (FU). METHODS: One hundred and fifty-eight patients received an LV Medtronic Performa lead (Medtronic Inc., Minneapolis, MN, USA) and were reevaluated at FU by echocardiography and measurement of electrical parameters. RESULTS: A targeted LV lead placement was achieved in 140 (89%) patients. Super responders and responders were 76 (50%) and 26 (18%), respectively, at FU; seven (4%) died and 13 (8%) were hospitalized for any cause. Nonischemic etiology was the only independent predictor of reverse remodeling. The configurations available only with the Performa leads reduced PNS occurrence at 8 V@0.4 ms from 43 (27%) to 14 (9%) of patients at implantation, and from 44 (28%) to 19 (12%) at last FU, compared to configurations available with bipolar leads. Patients with detectable PNS had >10/16 pacing configurations with a PNS safety margin >2 V both at implantation and at FU. During FU 16 (10%) patients had an adverse event possibly related to the lead or to modification of the underlying heart disease but 99% of these events were fixed by reprogramming of the pacing vector. CONCLUSIONS: Performa Lead enables an increased capability to achieve a targeted lead positioning in the broad clinical scenario of large- and small-volume implanting centers, with a relevant impact on the occurrence of reverse remodeling compared to literature data. The enhanced management of PNS resulted in a dislodgement rate of only 1%.


Subject(s)
Cardiac Resynchronization Therapy Devices , Electrodes, Implanted , Heart Failure/diagnosis , Heart Failure/prevention & control , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/prevention & control , Aged , Equipment Design , Equipment Failure Analysis , Female , Heart Failure/complications , Humans , Italy , Male , Treatment Outcome , Ventricular Dysfunction, Left/etiology , Ventricular Remodeling
10.
Recenti Prog Med ; 105(12): 469-72, 2014 Dec.
Article in Italian | MEDLINE | ID: mdl-25533235

ABSTRACT

Cardiac auscultation permits to distinguish between the innocent heart murmurs and pathologic murmurs; characteristics of pathologic murmurs include a holosystolic or diastolic murmur, maximal murmur intensity at the upper left sternal border and increased intensity when the patient stands. Murmurs should be described by their timing in the cardiac cycle, intensity, shape, pitch, location, radiation, and response to dynamic maneuvers. When the medical history and physical examination support the diagnosis of innocent heart murmur, neither further investigation nor referal is indicated. On the contrary, echocardiography is recommended for patients with any other abnormal physical examination findings that increase the likelihood of structural heart disease. In this review we discuss the definition and classification of murmurs, how to evaluate it.


Subject(s)
Heart Auscultation/methods , Heart Murmurs/diagnosis , Systolic Murmurs/diagnosis , Child , Echocardiography , Heart Murmurs/physiopathology , Humans , Systolic Murmurs/physiopathology
11.
J Innov Card Rhythm Manag ; 15(5): 5852-5856, 2024 May.
Article in English | MEDLINE | ID: mdl-38808172

ABSTRACT

A 78-year-old male patient with complete atrioventricular block underwent an uncomplicated pacemaker implantation. After 24 h, he presented acute chest pain, dyspnea, ST-segment-elevation in the anterior leads, left ventricular apical ballooning, and an ejection fraction of 35%. His coronary angiogram was normal. Within 2 days, his symptoms and electrocardiogram (ECG) abnormalities disappeared, while wall motion abnormalities recovered after 6 weeks. A diagnosis of takotsubo syndrome (TTS) was made. Pacemaker implantation has been described as a potential trigger for TTS. The clinical picture exhibits some peculiarities, including a higher percentage of men and asymptomatic patients and challenging ST-segment interpretation of paced ECGs. It is unclear whether pathophysiologic mechanisms are different compared to other forms of TTS and whether the acute initiation of ventricular pacing plays a role.

12.
Indian Heart J ; 65(1): 95-9, 2013.
Article in English | MEDLINE | ID: mdl-23438622

ABSTRACT

Orthostatic hypotension is the fall in blood pressure when upright and has a high prevalence in elderly population. Diagnostic and therapeutic work-up can be long and difficult. We describe the case of an 81-year-old male patient with long PR interval and episodes of 2:1 atrioventricular block, in whom the implantation of a dual chamber pacemaker led to the disappearance of orthostatic hypotension. The most likely mechanism was an impaired cardiac filling with a short diastolic time due to a very prolonged PR interval, a somewhat "pseudo-pacemaker syndrome". The correction of the first degree AV block with the implantation of the pacemaker and the optimization of the AV delay allowed us to correct the diastolic impairment and to resume a normal response to orthostatism. This case underlies the complex and multifactorial nature of orthostatic hypotension and the importance of a correct diagnosis of correctable causes to treat a very disabling condition.


Subject(s)
Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Hypotension, Orthostatic/prevention & control , Hypotension, Orthostatic/physiopathology , Pacemaker, Artificial , Aged, 80 and over , Electrocardiography , Humans , Male
13.
J Cardiovasc Med (Hagerstown) ; 24(12): 864-870, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37942788

ABSTRACT

AIMS: Brugada syndrome (BrS) is an inherited arrhythmic disease characterized by a coved ST-segment elevation in the right precordial electrocardiogram leads (type 1 ECG pattern) and is associated with a risk of malignant ventricular arrhythmias and sudden cardiac death. In order to assess the predictive value of the Shanghai Score System for the presence of a SCN5A mutation in clinical practice, we studied a cohort of 125 patients with spontaneous or fever/drug-induced BrS type 1 ECG pattern, variably associated with symptoms and a positive family history. METHODS: The Shanghai Score System items were collected for each patient and PR and QRS complex intervals were measured. Patients were genotyped through a next-generation sequencing (NGS) custom panel for the presence of SCN5A mutations and the common SCN5A polymorphism (H558R). RESULTS: The total Shanghai Score was higher in SCN5A+ patients than in SCN5A- patients. The 81% of SCN5A+ patients and the 100% of patients with a SCN5A truncating variant exhibit a spontaneous type 1 ECG pattern. A significant increase in PR (P = 0.006) and QRS (P = 0.02) was detected in the SCN5A+ group. The presence of the common H558R polymorphism did not significantly correlate with any of the items of the Shanghai Score, nor with the total score of the system. CONCLUSION: Data from our study suggest the usefulness of Shanghai Score collection in clinical practice in order to maximize genetic test appropriateness. Our data further highlight SCN5A mutations as a cause of conduction impairment in BrS patients.


Subject(s)
Brugada Syndrome , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/genetics , China/epidemiology , NAV1.5 Voltage-Gated Sodium Channel/genetics , Arrhythmias, Cardiac , Mutation , Electrocardiography
15.
Eur Heart J Acute Cardiovasc Care ; 9(1): 76-89, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31958018

ABSTRACT

This paper provides an update on the European Society of Cardiology task force report on the management of chest pain. Its main purpose is to provide an update on the decision algorithms and diagnostic pathways to be used in the emergency department for the assessment and triage of patients with chest pain symptoms suggestive of acute coronary syndromes.


Subject(s)
Acute Coronary Syndrome/diagnosis , Chest Pain/diagnosis , Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/diagnosis , Acute Coronary Syndrome/epidemiology , Acute Disease , Algorithms , Biomarkers/metabolism , Cardiology , Chest Pain/epidemiology , Decision Making , Emergency Service, Hospital/statistics & numerical data , Europe/epidemiology , Female , Humans , Male , Middle Aged , Myocardial Infarction/blood , Patient Care Management/standards , Percutaneous Coronary Intervention/methods , Risk Assessment , ST Elevation Myocardial Infarction/physiopathology , ST Elevation Myocardial Infarction/surgery , Societies, Medical/organization & administration , Triage , Troponin/blood
SELECTION OF CITATIONS
SEARCH DETAIL