Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Clin Diabetes ; 40(2): 168-184, 2022.
Article in English | MEDLINE | ID: mdl-35669307

ABSTRACT

Automated insulin delivery (AID) systems, which connect an insulin pump, continuous glucose monitoring system, and software algorithm to automate insulin delivery based on real-time glycemic data, hold promise for improving outcomes and reducing therapeutic burden for people with diabetes. This article reviews the features of the Omnipod 5 Automated Insulin Delivery System and how it compares to other AID systems available on or currently under review for the U.S. market. It also provides practical guidance for clinicians on how to effectively train and onboard people with diabetes on the Omnipod 5 System, including how to personalize therapy and optimize glycemia. Many people with diabetes receive their diabetes care in primary care settings rather than in a diabetes specialty clinic. Therefore, it is important that primary care providers have access to resources to support the adoption of AID technologies such as the Omnipod 5 System.

2.
Clin Diabetes ; 41(1): 45-55, 2022.
Article in English | MEDLINE | ID: mdl-36714251

ABSTRACT

This article describes how the T1D Exchange Quality Improvement Collaborative leverages an innovative web platform, the QI Portal, to gather and store electronic medical record (EMR) data to promote benchmarking and population health improvement in a type 1 diabetes learning health system. The authors explain the value of the QI Portal, the process for mapping center-level data from EMRs using standardized data specifications, and the QI Portal's unique features for advancing population health.

3.
Diabetes Spectr ; 34(2): 139-148, 2021 May.
Article in English | MEDLINE | ID: mdl-34149254

ABSTRACT

Despite significant pharmacological and technological advances in the treatment of type 1 diabetes, the majority of youth in the United States do not meet the American Diabetes Association's recommended A1C goal. Understanding and managing glycemic variability is important in children and adolescents. Because A1C provides an incomplete picture of day-to-day glycemic fluctuations, continuous glucose monitoring (CGM)-derived metrics are a promising addition to address glycemic management challenges in youth with diabetes. In this article, we discuss how to develop practical strategies to optimize the use of CGM in the pediatric population, interpret the valuable data it provides, and develop personalized and actionable treatment goals.

4.
Clin Diabetes ; 39(3): 256-263, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34421200

ABSTRACT

Despite immense strides in therapeutic advances, clinical outcomes continue to be less than ideal for people with type 1 diabetes. This discrepancy has prompted an outpouring of quality improvement (QI) initiatives to address the medical, psychosocial, and health equity challenges that complicate ideal type 1 diabetes care and outcomes. This article reviews a framework for QI in diabetes care that guided the development of the T1D Exchange Quality Improvement Collaborative to improve care delivery and health outcomes in type 1 diabetes. Evaluation of the methodology, outcomes, and knowledge gained from these initiatives will highlight the importance of continued QI initiatives in diabetes care.

5.
Pediatr Diabetes ; 21(2): 377-383, 2020 03.
Article in English | MEDLINE | ID: mdl-31808586

ABSTRACT

BACKGROUND: Across all age groups, management of type 1 diabetes (T1D) places substantial responsibility and emotional burden upon families. This study explored parent perceptions of the burdens of caring for very young children with T1D. METHODS: Semi-structured qualitative interviews were conducted with parents (85% mothers) of 79 children with T1D, aged 1 to <8 years old, from four diverse pediatric diabetes clinical centers. Interviews were transcribed, coded, and analyzed using hybrid thematic analysis to derive central themes. RESULTS: Youth (77% White) had T1D for ≥6 months: age (M ± SD) 5.2 ± 1.5 years, diabetes duration 2.4 ± 1.3 years, and A1c 63 ± 10 mmol/mol (7.9 ± 0.9%); 66% used an insulin pump and 61% used CGM. Three major themes emerged related to diabetes burdens: (a) the emotional burden of diabetes on themselves and their children, (b) the burden of finding, training, and trusting effective secondary caregivers to manage the child's diabetes, and (c) suggestions for how more comprehensive, personalized diabetes education from healthcare providers for parents and secondary caregivers could help reduce parent burden and worry. CONCLUSIONS: In families with very young children with T1D, parental perceptions of the burden of managing diabetes are common and could be mitigated by tailored education programs that increase parent knowledge, bolster parents' confidence in themselves, and increase trust in their secondary caregivers to manage diabetes. Reduced parental burden and increased caregiver knowledge may positively impact child's glycemic control, as well as improve parent and child quality of life.


Subject(s)
Cost of Illness , Diabetes Mellitus, Type 1/psychology , Parents/psychology , Child , Child, Preschool , Diabetes Mellitus, Type 1/therapy , Female , Humans , Hypoglycemic Agents/administration & dosage , Insulin/administration & dosage , Interviews as Topic , Male , Parenting , Psychological Distress , Qualitative Research
6.
Diabetes Spectr ; 33(1): 22-30, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32116450

ABSTRACT

Despite significant advances in therapies for pediatric type 1 diabetes, achievement of glycemic targets remains elusive, and management remains burdensome for patients and their families. This article identifies common challenges in diabetes management at the patient-provider and health care system levels and proposes practical approaches to overcoming therapeutic inertia to enhance health outcomes for youth with type 1 diabetes.

7.
JAMA ; 323(23): 2388-2396, 2020 06 16.
Article in English | MEDLINE | ID: mdl-32543683

ABSTRACT

Importance: Adolescents and young adults with type 1 diabetes exhibit the worst glycemic control among individuals with type 1 diabetes across the lifespan. Although continuous glucose monitoring (CGM) has been shown to improve glycemic control in adults, its benefit in adolescents and young adults has not been demonstrated. Objective: To determine the effect of CGM on glycemic control in adolescents and young adults with type 1 diabetes. Design, Setting, and Participants: Randomized clinical trial conducted between January 2018 and May 2019 at 14 endocrinology practices in the US including 153 individuals aged 14 to 24 years with type 1 diabetes and screening hemoglobin A1c (HbA1c) of 7.5% to 10.9%. Interventions: Participants were randomized 1:1 to undergo CGM (CGM group; n = 74) or usual care using a blood glucose meter for glucose monitoring (blood glucose monitoring [BGM] group; n = 79). Main Outcomes and Measures: The primary outcome was change in HbA1c from baseline to 26 weeks. There were 20 secondary outcomes, including additional HbA1c outcomes, CGM glucose metrics, and patient-reported outcomes with adjustment for multiple comparisons to control for the false discovery rate. Results: Among the 153 participants (mean [SD] age, 17 [3] years; 76 [50%] were female; mean [SD] diabetes duration, 9 [5] years), 142 (93%) completed the study. In the CGM group, 68% of participants used CGM at least 5 days per week in month 6. Mean HbA1c was 8.9% at baseline and 8.5% at 26 weeks in the CGM group and 8.9% at both baseline and 26 weeks in the BGM group (adjusted between-group difference, -0.37% [95% CI, -0.66% to -0.08%]; P = .01). Of 20 prespecified secondary outcomes, there were statistically significant differences in 3 of 7 binary HbA1c outcomes, 8 of 9 CGM metrics, and 1 of 4 patient-reported outcomes. The most commonly reported adverse events in the CGM and BGM groups were severe hypoglycemia (3 participants with an event in the CGM group and 2 in the BGM group), hyperglycemia/ketosis (1 participant with an event in CGM group and 4 in the BGM group), and diabetic ketoacidosis (3 participants with an event in the CGM group and 1 in the BGM group). Conclusions and Relevance: Among adolescents and young adults with type 1 diabetes, continuous glucose monitoring compared with standard blood glucose monitoring resulted in a small but statistically significant improvement in glycemic control over 26 weeks. Further research is needed to understand the clinical importance of the findings. Trial Registration: ClinicalTrials.gov Identifier: NCT03263494.


Subject(s)
Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/blood , Glycated Hemoglobin/analysis , Hypoglycemic Agents/administration & dosage , Adolescent , Blood Glucose/analysis , Blood Glucose Self-Monitoring/instrumentation , Diabetes Mellitus, Type 1/drug therapy , Diabetic Ketoacidosis , Female , Humans , Hyperglycemia/diagnosis , Hyperglycemia/prevention & control , Hypoglycemia/chemically induced , Hypoglycemia/diagnosis , Hypoglycemia/prevention & control , Hypoglycemic Agents/adverse effects , Male , Mobile Applications , Monitoring, Ambulatory/instrumentation , Young Adult
8.
Diabetes Obes Metab ; 21(1): 170-172, 2019 01.
Article in English | MEDLINE | ID: mdl-30039636

ABSTRACT

For individuals aged 10 to <40 years with type 1 diabetes and dyslipidaemia, US national guidelines recommend consideration of statin therapy based on age, low-density lipoprotein cholesterol (LDL-C) level and other cardiovascular risk factors. We evaluated dyslipidaemia prevalence, statin therapy use, and associations between not meeting target LDL-C [<100 mg/dL (<5.55 mmol/L)] and other cardiovascular disease (CVD) risk factors in individuals aged 10 to <40 years in the T1D Exchange clinic registry. In 7223 participants, statin use was 2% in 10 to <18 year olds, 4% in 18 to <25 year olds, and 21% in 25 to <40 year olds. Individuals not on statin therapy with LDL-C above target were more likely to have ≥1 additional CVD risk factor(s) than those with LDL-C in the target range for all age groups (all P < 0.01). While most individuals not on statin therapy had LDL-C in the target range, those who did not were more likely to have ≥1 additional CVD risk factor(s), and therefore longitudinal study of lipid levels and statin use is needed to see if treatment of dyslipidaemia to target LDL-C levels may lower the risk of future CVD in individuals aged 10 to <40 years with type 1 diabetes.


Subject(s)
Diabetes Mellitus, Type 1 , Dyslipidemias , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Adolescent , Adult , Child , Cross-Sectional Studies , Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 1/epidemiology , Dyslipidemias/complications , Dyslipidemias/drug therapy , Dyslipidemias/epidemiology , Female , Humans , Male , United States/epidemiology , Young Adult
9.
Pediatr Diabetes ; 19(7): 1271-1275, 2018 11.
Article in English | MEDLINE | ID: mdl-29923262

ABSTRACT

BACKGROUND: To assess the change in rates of pediatric real-time or intermittent scanning continuous glucose monitoring (CGM) use over the past 5 years, and how it impacts glycemic control, data from two registries were compared: the US-based type 1 diabetes Exchange Registry (T1DX) and the German/Austrian DPV (Prospective Diabetes Follow-Up Registry). METHODS: Registry participants aged <18 years with T1D duration ≥1 year encompassed 29 007 individuals in 2011 and 29 150 participants in 2016. Demographic data, CGM use and hemoglobin A1c (HbA1c) were obtained from medical records. RESULTS: CGM use increased from 2011 to 2016 in both registries across all age groups, regardless of gender, ethnic minority status or insulin delivery method. The increase in CGM use was most pronounced in the youngest patients, and usage rates remain lowest for adolescent patients in 2016. For both registries in 2016, mean HbA1c was lower among CGM users regardless of insulin delivery method compared to pump only (P < 0.001) and injection only (P < 0.001), and CGM users were more likely to achieve glycemic target of HbA1c <7.5% (56% vs 43% for DPV and 30% vs 15% for T1DX, P < 0.001). T1DX participants had a higher mean HbA1c compared with DPV despite whether they were CGM users or non-users; however, the difference was less pronounced in CGM users (P < 0.001). CONCLUSIONS: Pediatric CGM use increased in both registries and was associated with lower mean HbA1c regardless of insulin delivery modality.


Subject(s)
Blood Glucose Self-Monitoring/statistics & numerical data , Blood Glucose/analysis , Diabetes Mellitus, Type 1/blood , Registries , Wearable Electronic Devices/statistics & numerical data , Adolescent , Child , Child, Preschool , Female , Humans , Male
10.
Pediatr Diabetes ; 19(1): 114-120, 2018 02.
Article in English | MEDLINE | ID: mdl-28429581

ABSTRACT

BACKGROUND: Fear of hypoglycemia is common in parents of young children with type 1 diabetes (T1D), but little is known about the specific fears that parents most often experience. Hypoglycemia fear has been associated with poorer glycemic control in older children, though not yet studied in a large cohort of very young children. MATERIALS AND METHODS: Parents of 549 children <7 years (mean 5.2 ± 1.2 years [19% <3 years]) with a mean diabetes duration of 2.4 ± 1.0 years (range 1-6 years) and mean HbA1c 8.2% ± 1.1% (66 ± 12 mmol/mol) registered in the T1D Exchange completed the worry scale of the Hypoglycemia Fear Survey modified for parents (HFS-P). RESULTS: Mean parental fear of hypoglycemia worry score was 36.1 ± 23.1 (possible range 0-100), with most frequent worries related to the child having a low while asleep and the child not recognizing a low. The mean worry score was not associated with the child's age, glycemic control, or recent severe hypoglycemic event. Parental worries about lows while sleeping were significantly higher in pump users than non-users (61% vs. 45%; P < .001), and tended to be higher in CGM users than non-users (62% vs 51%; P = .02). CONCLUSIONS: The greatest worries of parents of young children with T1D were related to hypoglycemia during sleep and other times/circumstances during which it would be difficult to detect hypoglycemia. Using advanced diabetes technologies may be an effort to temper fears about hypoglycemia during sleep, though the directionality of this relationship is undetermined. Additional studies can clarify this association and leverage use of diabetes technologies to improve glycemic control.


Subject(s)
Diabetes Mellitus, Type 1 , Fear , Hypoglycemia/chemically induced , Parents/psychology , Registries , Adult , Child , Child, Preschool , Circadian Rhythm , Female , Humans , Hypoglycemic Agents/adverse effects , Insulin/adverse effects , Male
14.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38277156

ABSTRACT

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1 , Glycated Hemoglobin , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Humans , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 1/blood , Child, Preschool , Insulin/administration & dosage , Insulin/therapeutic use , Female , Male , Blood Glucose/analysis , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Glycated Hemoglobin/analysis , Hypoglycemia/prevention & control , Treatment Outcome , Glycemic Control/methods , Blood Glucose Self-Monitoring
15.
Article in English | MEDLINE | ID: mdl-38375861

ABSTRACT

Background: The Omnipod® 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. Methods: A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed. Target glucose setting usage (i.e., 110-150 mg/dL in 10 mg/dL increments) was summarized and glycemic outcomes were examined. Subgroup analyses of those using the lowest average glucose target (110 mg/dL) and stratification by baseline characteristics (e.g., age, prior therapy, health insurance coverage) were conducted. Results: In total, 69,902 users were included. Multiple and higher glucose targets were more commonly used in younger age groups. Median percentage of time in range (TIR; 70-180 mg/dL) was 68.8%, 61.3%, and 53.6% for users with average glucose targets of 110, 120, and 130-150 mg/dL, respectively, with minimal time <70 mg/dL (all median <1.13%). Among those with an average glucose target of 110 mg/dL (n = 37,640), median TIR was 65.0% in children and adolescents (2-17 years) and 69.9% in adults (≥18 years). Subgroup analyses of users transitioning from Omnipod DASH or multiple daily injections and of Medicaid/Medicare users demonstrated favorable glycemic outcomes among these groups. Conclusion: These glycemic outcomes from a large and diverse sample of nearly 70,000 children and adults demonstrate effective use of the Omnipod 5 System under real-world conditions.

16.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37850941

ABSTRACT

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Subject(s)
Diabetes Mellitus, Type 1 , Adult , Child , Humans , Adolescent , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Glycated Hemoglobin , Insulin Infusion Systems , Blood Glucose , Blood Glucose Self-Monitoring
17.
J Pediatr Endocrinol Metab ; 26(3-4): 215-21, 2013.
Article in English | MEDLINE | ID: mdl-23744298

ABSTRACT

BACKGROUND: Premature adrenarche (PA) is often associated with bone age (BA) advanced by ≥2 years, which increases the concern for underlying pathology, but the frequency and clinical significance of this is unknown. Our objective was to identify the proportion of PA patients with very advanced BA and normal BA and compare the clinical characteristics of the two groups. METHODS: Charts of 427 patients aged 5-9 years, referred for early puberty over a 2-year period, were reviewed for clinical diagnosis, growth, parental heights, hormone levels and BA. We divided the PA patients into three separate groups based on degree of BA advancement. Predicted adult heights (PAH) were calculated and compared to mid-parental target height (TH). RESULTS: Of 427 patients, 266 (62%) had PA (82% female). Of the 121 with BA, 30.6% had very advanced BA (≥2 years) and this group was taller (Ht SD+1.72 vs. +0.72, p<0.00001) and had higher BMI (SD+1.70 vs. +0.99, p<0.001) than patients with BA advanced by <1 year, but hormone levels were quite similar. Mean PAH was slightly less than TH for patients with very advanced BA, but there were no girls with PAH <60 inches 152.4 cm or boys with PAH <65 inches 165.1 cm in height. CONCLUSIONS: Very advanced BA is common in PA, and patients were significantly taller and more overweight than their peers. The impact of advanced BA on PAH appears to be minor. We question the need for ordering a BA in patients with PA, and suggest that extensive testing is unnecessary simply because of advanced BA.


Subject(s)
Adrenal Hyperplasia, Congenital/physiopathology , Adrenarche/physiology , Bone Development/physiology , Puberty, Precocious/physiopathology , Body Height/physiology , Body Mass Index , Child , Child, Preschool , Cohort Studies , Dehydroepiandrosterone Sulfate/blood , Female , Humans , Male , Severity of Illness Index
18.
Front Digit Health ; 5: 1142021, 2023.
Article in English | MEDLINE | ID: mdl-37274763

ABSTRACT

Physical activity (PA) provides numerous health benefits for individuals with type 1 diabetes (T1D). However, the threat of exercise-induced hypoglycemia may impede the desire for regular PA. Therefore, we aimed to study the association between three common types of PA (walking, running, and cycling) and hypoglycemia risk in 50 individuals with T1D. Real-world data, including PA duration and intensity, continuous glucose monitor (CGM) values, and insulin doses, were available from the Tidepool Big Data Donation Project. Participants' mean (SD) age was 38.0 (13.1) years with a mean (SD) diabetes duration of 21.4 (12.9) years and an average of 26.2 weeks of CGM data available. We developed a linear regression model for each of the three PA types to predict the average glucose deviation from 70 mg/dl for the 2 h after the start of PA. This is essentially a measure of hypoglycemia risk, for which we used the following predictors: PA duration (mins) and intensity (calories burned), 2-hour pre-exercise area under the glucose curve (adjusted AUC), the glucose value at the beginning of PA, and total bolus insulin (units) within 2 h before PA. Our models indicated that glucose value at the start of exercise and pre-exercise glucose adjusted AUC (p < 0.001 for all three activities) were the most significant predictors of hypoglycemia. In addition, the duration and intensity of PA and 2-hour bolus insulin were weakly associated with hypoglycemia for walking, running, and cycling. These findings may provide individuals with T1D with a data-driven approach to preparing for PA that minimizes hypoglycemia risk.

19.
Diabetes Ther ; 14(3): 593-610, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36763329

ABSTRACT

INTRODUCTION: Despite recent advances in diabetes technology, most people living with type 1 diabetes mellitus (T1D) are unable to meet glycemic targets. Real-world evidence can provide insight into outcomes achieved with specific treatment devices when used in clinical practice. The aim of this study was to analyze real-world outcomes collected from a large cohort of people living with T1D and initiating treatment with the Omnipod DASH System. METHODS: In this retrospective observational study, real-world outcomes were analyzed from a database of information collected from people with T1D initiating the Omnipod DASH System. Information in the database was either taken directly from the patient's medical record or self-reported if medical records were unavailable. The primary outcome was change in glycated hemoglobin (HbA1c) from baseline (before initiation) to 3 months after initiation. Secondary outcomes were changes in total daily dose of insulin (TDD) and self-reported frequency of hypoglycemic events (< 70 mg/dL). Results are separated for the adult (≥ 18 years, N = 3341) and pediatric (< 18 years, N = 1397) cohorts. RESULTS: The change in HbA1c from baseline was - 0.9 ± 1.6% ( - 10 ± 18 mmol/mol; p < 0.0001) in adults and - 0.9 ± 2.0% ( - 10 ± 22 mmol/mol; p < 0.0001) in the pediatric cohort. For those previously using multiple daily injections, HbA1c decreased by - 1.0 ± 1.7% ( - 11 ± 19 mmol/mol) in adults and - 1.0 ± 2.1% ( - 11 ± 23 mmol/mol) in the pediatric cohort (both p < 0.0001). Hypoglycemic events decreased in adults from 2.9 to 1.3 episodes per week ( - 1.6 ± 3.2 events/week; p < 0.0001), and in the pediatric cohort from 2.8 to 1.5 episodes per week ( - 1.3 ± 2.7 events/week; p < 0.0001). In adults, TDD decreased by 19.9% (p < 0.0001), and it remained stable in the pediatric cohort (p > 0.05). CONCLUSIONS: Real-world outcomes from this large cohort of people initiating therapy with the Omnipod DASH System showed significant improvement in HbA1c and a substantial reduction in hypoglycemic events after 3 months of use.

20.
J Diabetes Sci Technol ; 17(2): 322-328, 2023 03.
Article in English | MEDLINE | ID: mdl-34632823

ABSTRACT

BACKGROUND: The benefits of Continuous Glucose Monitoring (CGM) on glycemic management have been demonstrated in numerous studies; however, widespread uptake remians limited. The aim of this study was to provide real-world evidence of patient attributes and clinical outcomes associated with CGM use across clinics in the U.S. based T1D Exchange Quality Improvement (T1DX-QI) Collaborative. METHOD: We examined electronic Health Record data from eight endocrinology clinics participating in the T1DX-QI Collaborative during the years 2017-2019. RESULTS: Among 11,469 type 1 diabetes patients, 48% were CGM users. CGM use varied by race/ethnicity with Non-Hispanic Whites having higher rates of CGM use (50%) compared to Non-Hispanic Blacks (18%) or Hispanics (38%). Patients with private insurance were more likely to use CGM (57.2%) than those with public insurance (33.3%) including Medicaid or Medicare. CGM users had lower median HbA1c (7.7%) compared to nonusers (8.4%). Rates of diabetic ketoacidosis (DKA) and severe hypoglycemia were significantly higher in nonusers compared to CGM users. CONCLUSION: In this real-world study of patients in the T1DX-QI Collaborative, CGM users had better glycemic control and lower rates of DKA and severe hypoglycemia (SH) events, compared to nonusers; however, there were significant sociodemographic disparities in CGM use. Quality improvement and advocacy measures to promote widespread and equitable CGM uptake have the potential to improve clinical outcomes.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetic Ketoacidosis , Hypoglycemia , United States/epidemiology , Humans , Aged , Diabetes Mellitus, Type 1/drug therapy , Blood Glucose , Blood Glucose Self-Monitoring , Medicare , Demography
SELECTION OF CITATIONS
SEARCH DETAIL