Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38195003

ABSTRACT

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/epidemiology , Arrhythmogenic Right Ventricular Dysplasia/therapy , Retrospective Studies , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Risk Factors , North America/epidemiology , Europe/epidemiology
2.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584394

ABSTRACT

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
3.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38674168

ABSTRACT

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Subject(s)
Defibrillators, Implantable , Magnetic Resonance Imaging , Pacemaker, Artificial , Humans , Defibrillators, Implantable/standards , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/instrumentation , Arrhythmias, Cardiac/diagnostic imaging
4.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38674259

ABSTRACT

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Subject(s)
Amyloidosis , Cardiomyopathies , Cicatrix , Magnetic Resonance Imaging , Humans , Male , Pilot Projects , Female , Cardiomyopathies/diagnostic imaging , Amyloidosis/diagnostic imaging , Amyloidosis/complications , Aged , Cicatrix/diagnostic imaging , Retrospective Studies , Middle Aged , Magnetic Resonance Imaging/methods , Software
5.
Medicina (Kaunas) ; 60(7)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-39064511

ABSTRACT

Mitral regurgitation (MR) is a broadly diffuse valvular heart disease (VHD) with a significant impact on the healthcare system and patient prognosis. Transcatheter mitral valve interventions (TMVI) are now well-established techniques included in the therapeutic armamentarium for managing patients with mitral regurgitation, either primary or functional MR. Even if the guidelines give indications regarding the correct management of this VHD, the wide heterogeneity of patients' clinical backgrounds and valvular and heart anatomies make each patient a unique case, in which the appropriate device's selection requires a multimodal imaging evaluation and a multidisciplinary discussion. Proper pre-procedural evaluation plays a pivotal role in judging the feasibility of TMVI, while a cooperative work between imagers and interventionalist is also crucial for procedural success. This manuscript aims to provide an exhaustive overview of the main parameters that need to be evaluated for appropriate device selection, pre-procedural planning, intra-procedural guidance and post-operative assessment in the setting of TMVI. In addition, it tries to give some insights about future perspectives for structural cardiovascular imaging.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Multimodal Imaging , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Multimodal Imaging/methods , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/standards , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/instrumentation
6.
Circulation ; 146(19): 1434-1443, 2022 11 08.
Article in English | MEDLINE | ID: mdl-36205131

ABSTRACT

BACKGROUND: A novel risk calculator based on clinical characteristics and noninvasive tests that predicts the onset of clinical sustained ventricular arrhythmias (VA) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) has been proposed and validated by recent studies. It remains unknown whether programmed ventricular stimulation (PVS) provides additional prognostic value. METHODS: All patients with a definite ARVC diagnosis, no history of sustained VAs at diagnosis, and PVS performed at baseline were extracted from 6 international ARVC registries. The calculator-predicted risk for sustained VA (sustained or implantable cardioverter defibrillator treated ventricular tachycardia [VT] or fibrillation, [aborted] sudden cardiac arrest) was assessed in all patients. Independent and combined performance of the risk calculator and PVS on sustained VA were assessed during a 5-year follow-up period. RESULTS: Two hundred eighty-eight patients (41.0±14.5 years, 55.9% male, right ventricular ejection fraction 42.5±11.1%) were enrolled. At PVS, 137 (47.6%) patients had inducible ventricular tachycardia. During a median of 5.31 [2.89-10.17] years of follow-up, 83 (60.6%) patients with a positive PVS and 37 (24.5%) with a negative PVS experienced sustained VA (P<0.001). Inducible ventricular tachycardia predicted clinical sustained VA during the 5-year follow-up and remained an independent predictor after accounting for the calculator-predicted risk (HR, 2.52 [1.58-4.02]; P<0.001). Compared with ARVC risk calculator predictions in isolation (C-statistic 0.72), addition of PVS inducibility showed improved prediction of VA events (C-statistic 0.75; log-likelihood ratio for nested models, P<0.001). PVS inducibility had a 76% [67-84] sensitivity and 68% [61-74] specificity, corresponding to log-likelihood ratios of 2.3 and 0.36 for inducible (likelihood ratio+) and noninducible (likelihood ratio-) patients, respectively. In patients with a ARVC risk calculator-predicted risk of clinical VA events <25% during 5 years (ie, low/intermediate subgroup), PVS had a 92.6% negative predictive value. CONCLUSIONS: PVS significantly improved risk stratification above and beyond the calculator-predicted risk of VA in a primary prevention cohort of patients with ARVC, mainly for patients considered to be at low and intermediate risk by the clinical risk calculator.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Primary Prevention , Female , Humans , Male , Arrhythmias, Cardiac/epidemiology , Arrhythmogenic Right Ventricular Dysplasia/epidemiology , Arrhythmogenic Right Ventricular Dysplasia/prevention & control , Death, Sudden, Cardiac/epidemiology , Defibrillators, Implantable , Primary Prevention/methods , Risk Assessment/methods , Risk Factors , Stroke Volume , Tachycardia, Ventricular/epidemiology , Ventricular Function, Right , Adult , Middle Aged
7.
J Cardiovasc Electrophysiol ; 34(5): 1216-1227, 2023 05.
Article in English | MEDLINE | ID: mdl-37087672

ABSTRACT

INTRODUCTION: The assessment of the ventricular myocardial substrate critically depends on the size of mapping electrodes, their orientation with respect to wavefront propagation, and interelectrode distance. We conducted a dual-center study to evaluate the impact of microelectrode mapping in patients undergoing catheter ablation (CA) of ventricular tachycardia (VT). METHODS: We included 21 consecutive patients (median age, 68 [12], 95% male) with structural heart disease undergoing CA for electrical storm (n = 14) or recurrent VT (n = 7) using the QDOT Micro catheter and a multipolar catheter (PentaRay, n = 9). The associations of peak-to-peak maximum standard bipolar (BVc ) and minibipolar (PentaRay, BVp ) with microbipolar (BVµMax ) voltages were respectively tested in sinus rhythm with mixed effect models. Furthermore, we compared the features of standard bipolar (BE) and microbipolar (µBE) electrograms in sinus rhythm at sites of termination with radiofrequency energy. RESULTS: BVµMax was moderately associated with both BVc (ß = .85, p < .01) and BVp (ß = .56, p < .01). BVµMax was 0.98 (95% CI: 0.93-1.04, p < .01) mV larger than corresponding BVc , and 0.27 (95% CI: 0.16-0.37, p < .01) mV larger than matching BVp in sinus rhythm, with higher percentage differences in low voltage regions, leading to smaller endocardial dense scar (2.3 [2.7] vs. 12.1 [17] cm2 , p < .01) and border zone (3.2 [7.4] vs. 4.8 [20.1] cm2 , p = .03) regions in microbipolar maps compared to standard bipolar maps. Late potentials areas were nonsignificantly greater in microelectrode maps, compared to standard electrode maps. At sites of VT termination (n = 14), µBE were of higher amplitude (0.9 [0.8] vs. 0.4 [0.2] mV, p < .01), longer duration (117 [66] vs. 74 [38] ms, p < .01), and with greater number of peaks (4 [2] vs. 2 [1], p < .01) in sinus rhythm compared to BE. CONCLUSION: microelectrode mapping is more sensitive than standard bipolar mapping in the identification of viable myocytes in SR, and may facilitate recognition of targets for CA.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Male , Aged , Female , Microelectrodes , Treatment Outcome , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/complications , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cicatrix
8.
J Cardiovasc Electrophysiol ; 34(5): 1257-1267, 2023 05.
Article in English | MEDLINE | ID: mdl-36994907

ABSTRACT

INTRODUCTION: The prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. METHODS: Five hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. RESULTS: Over a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic ≥ 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of ≥1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. CONCLUSION: The HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Ventricular Dysfunction, Left , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/complications , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Cardiac Resynchronization Therapy/adverse effects , Ventricular Dysfunction, Left/therapy
9.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37490930

ABSTRACT

AIMS: Infections resulting from cardiac implantable electronic device (CIED) implantation are severely impacting on patients' and on health care systems. The use of TYRXTM absorbable antibiotic-eluting envelope has proven to decrease major CIED infections within 12 months of CIED surgery. The aim is to evaluate the impact of the envelope use on infection-related clinical events in a real-world contemporary patient population. METHODS AND RESULTS: Data on patients undergoing CIED surgery were collected prospectively by participating centers of the One Hospital ClinicalService project. Patients were divided into two groups according to whether TYRXTM absorbable antibiotic-eluting envelope was used or not. Out of 1819 patients, 872 (47.9%) were implanted with an absorbable antibiotic-eluting envelope and included in the Envelope group and 947 (52.1%) patients who did not receive an envelope were included in the Control group. Compared to control, patients in the Envelope group had higher thrombo-embolic or hemorrhagic risk, higher BMI, lower LVEF and more comorbidities. During a mean follow-up of 1.4 years, the incidence of infection-related events was significantly higher in the control compared to the Envelope group (2.4% vs. 0.8%, P = 0.007). The five-year cumulative incidence of infection-related events was 8.1% in the control and 2.1% in the Envelope group (HR: 0.34, 95%CI: 0.14-0.80, P = 0.010). CONCLUSION: In our analysis, the use of an absorbable antibiotic-eluting envelope in the general CIED population was associated with a lower risk of systemic and pocket infection.


Subject(s)
Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Anti-Bacterial Agents/therapeutic use , Causality , Heart Diseases/complications , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/prevention & control
10.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37536671

ABSTRACT

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Cardiomyopathies , Channelopathies , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Channelopathies/complications , Channelopathies/therapy , Treatment Outcome , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Cardiomyopathies/complications , Cardiomyopathies/therapy , Registries
11.
Europace ; 25(4): 1467-1474, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36881780

ABSTRACT

AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Heart Failure , Sleep Apnea Syndromes , Humans , Defibrillators, Implantable/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Risk Assessment , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/therapy
12.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-36932709

ABSTRACT

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular/diagnosis , Follow-Up Studies , Prospective Studies , Electric Countershock , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy
13.
Europace ; 25(4): 1423-1431, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36794691

ABSTRACT

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Subject(s)
Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Case-Control Studies , Death, Sudden, Cardiac/etiology , Retrospective Studies , Treatment Outcome
14.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37656991

ABSTRACT

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Heart Failure , Humans , Algorithms , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Heart Atria , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/therapy
15.
Eur Heart J Suppl ; 25(Suppl C): C258-C260, 2023 May.
Article in English | MEDLINE | ID: mdl-37125284

ABSTRACT

Ablation targets of persistent atrial fibrillation remain poorly understood nowadays: due to structural alterations of the left atrium, isolation of the pulmonary veins alone has proved ineffective. New ablation targets such as the posterior wall, coronary sinus, and left atrial appendage were then sought. A new catheter (QDOT Micro™) has recently been released, which has the potential to increase the safety and efficacy of the procedure: it is connected to a new radiofrequency generator that allows for temperature-controlled ablation by reducing power and increasing irrigation with the increase in tissue temperature and allows to deliver power up to 90 W for few seconds (very high-power short-duration).

16.
Eur Heart J ; 43(32): 3041-3052, 2022 08 21.
Article in English | MEDLINE | ID: mdl-35766180

ABSTRACT

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) causes ventricular arrhythmias (VAs) and sudden cardiac death (SCD). In 2019, a risk prediction model that estimates the 5-year risk of incident VAs in ARVC was developed (ARVCrisk.com). This study aimed to externally validate this prediction model in a large international multicentre cohort and to compare its performance with the risk factor approach recommended for implantable cardioverter-defibrillator (ICD) use by published guidelines and expert consensus. METHODS AND RESULTS: In a retrospective cohort of 429 individuals from 29 centres in North America and Europe, 103 (24%) experienced sustained VA during a median follow-up of 5.02 (2.05-7.90) years following diagnosis of ARVC. External validation yielded good discrimination [C-index of 0.70 (95% confidence interval-CI 0.65-0.75)] and calibration slope of 1.01 (95% CI 0.99-1.03). Compared with the three published consensus-based decision algorithms for ICD use in ARVC (Heart Rhythm Society consensus on arrhythmogenic cardiomyopathy, International Task Force consensus statement on the treatment of ARVC, and American Heart Association guidelines for VA and SCD), the risk calculator performed better with a superior net clinical benefit below risk threshold of 35%. CONCLUSION: Using a large independent cohort of patients, this study shows that the ARVC risk model provides good prognostic information and outperforms other published decision algorithms for ICD use. These findings support the use of the model to facilitate shared decision making regarding ICD implantation in the primary prevention of SCD in ARVC.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Arrhythmias, Cardiac/etiology , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Humans , Retrospective Studies , Risk Factors
17.
J Cardiovasc Electrophysiol ; 33(5): 874-882, 2022 05.
Article in English | MEDLINE | ID: mdl-35262242

ABSTRACT

INTRODUCTION: Lesion Index (LSI) has been developed to predict lesion efficacy during radiofrequency (RF) catheter ablation. However, its value in predicting lesions size has still to be established. The aim of our study was to assess the lesions size reproducibility for prespecified values of LSI reached during RF delivery in an in vivo beating heart. METHODS: Ablation lesions were created with different values of LSI in seven domestic pigs by means of a contact force-sensing catheter (TactiCathTM , Abbott). Lesions were identified during RF delivery by means of a three-dimensional mapping system (EnSiteTM Precision, Abbott) and measured after heart explantation. Histology was carried out after gross examination on the first three lesions to confirm the accuracy of the macroscopic evaluation. RESULTS: A total of 64 myocardial lesions were created. Thirty-nine lesions were excluded from the analysis for the following reasons: histological confirmation of macroscopic lesion measurement (n = 3), transmurality (n = 24), unfavorable anatomic position (n = 10), not macroscopically identifiable (n = 2). In a final set of 25 nontransmural lesions, injury width and depth were, respectively, 4.6 ± 0.6 and 2.6 ± 0.8 mm for LSI = 4, 7.3 ± 0.8 and 4.7 ± 0.6 mm for LSI = 5, and 8.6 ± 1.2 and 7.2 ± 1.1 mm for LSI = 6. A strong linear correlation was observed between LSI and lesion width (r = .87, p < .00001) and depth (r = .89, p < .00001). Multiple linear regression analysis identified LSI as the only ablation parameter that significantly predicted lesion width (p < .001) and depth (p < .001). CONCLUSION: In our in vivo study, LSI proved highly predictive of lesion size and depth.


Subject(s)
Catheter Ablation , Animals , Catheter Ablation/adverse effects , Catheter Ablation/methods , Catheters , Heart , Humans , Reproducibility of Results , Sus scrofa , Swine
18.
J Cardiovasc Electrophysiol ; 33(7): 1567-1575, 2022 07.
Article in English | MEDLINE | ID: mdl-35634866

ABSTRACT

INTRODUCTION: Left ventricular (LV) lead optimal positioning is one of the most important determinants of cardiac resynchronization therapy (CRT) success. LV quadripolar active fixation (QAF) leads have been designed to ensure stable LV pacing in the target area and reduce the likelihood of phrenic nerve stimulation (PNS). The aim of this analysis is to compare performances, safety, and clinical outcomes of QAF with those of quadripolar passive fixation leads (QPL) and bipolar active fixation (BAF) leads in a real-world cohort of CRT patients. METHODS AND RESULTS: This retrospective analysis compared the procedure and follow-up data of 117 QAF included in the One Hospital ClinicalService project from nine Italian hospitals with two historical cohorts of 261 BAF and 124 QPL. QAF enabled basal pacing more frequently than QPL (24.1% vs. 6.5%, p < .001) but not differently from BAF (p = .981). At implant, mean QAF LV myocardial threshold (LVMT) was 1.21 ± 0.8 V at 0.4 ms, not different from that of BAF (p = .346) and QPL (p = .333). At a median follow-up of 22 months, LVMT was 1.37 ± 0.90 V (p = .036 vs. implant). Acute LV lead dislodgment occurrence was low in all cohorts: 1 (0.9%) in QAF, 4 in BAF (1.5%), and none (0.0%) in QPL. During follow-up, total LV-related complication rate was lower in QAF (0.5/100 patient-years) than in BAF (4.2/100 patient-years, p = .014) and QPL (3.6/100 patient-years, p = .055). QAF, BAF, and QPL annual rate of heart failure hospitalization were respectively 6.1/100 patient-years, 2.5/100 patient-years (p = .081), and 3.6/100 patient-years (p = .346). CRT responders' rate in QAF was 69.9%, with no difference in comparison to BAF (p = .998) and QPL (p = .509). During follow-up, mean left ventricular ejection fraction (LVEF) of QAF increased from 31.8 ± 10.1% to 40.3 ± 10.7% (p < .001). The average degree of echocardiographic response (ΔLVEF) did not differ between QAF and other cohorts; however, LVEF CRT responder's distribution of QAF differs from those of BAF (p = .003) and QPL (p = .022), due to a higher percentage of super-responders. CONCLUSIONS: QAF with short interelectrode spacing resulted in non-inferior clinical outcomes and CRT responders' rate in comparison to BAF and QPL, while reducing complication rate during follow-up and increasing the possibilities of electronic repositioning to manage PNS or to optimize resynchronization therapy.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy Devices , Follow-Up Studies , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left
19.
J Cardiovasc Electrophysiol ; 33(11): 2288-2296, 2022 11.
Article in English | MEDLINE | ID: mdl-35930617

ABSTRACT

INTRODUCTION: In patients with symptomatic permanent atrial fibrillation (PEAF) and narrow QRS, atrio-ventricular junction ablation (AVJA) plus cardiac resynchronization therapy (CRT) is superior to medical therapy in reducing heart failure (HF) hospitalization and all-cause mortality. To compare the mortality of a population of patients with HF, reduced EF (rEF), and PEAF treated with AVJA plus CRT with that of a contemporary cohort of patients in sinus rhythm (SR) with similar baseline characteristics. METHODS AND RESULTS: In this prospective, multicentre, observational study, all-cause mortality in a group of consecutive patients undergoing AVJA and implantable cardioverter-defibrillator (ICD) combined with CRT implantation for HFrEF, narrow QRS, and PEAF with uncontrolled ventricular rate was compared with that of a contemporary cohort of patients in SR undergoing ICD implantation (not combined with CRT) for HFrEF and narrow QRS. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 824 patients were enrolled. Propensity matching yielded 107 matched pairs. After a median follow-up of 52 months, all-cause mortality was similar in patients treated with AVJA plus CRT and in the control group (p = .434). In AVJA plus CRT patients, mortality was significantly lower than in control group patients with a history of paroxysmal/persistent AF (n = 45, p = .020), and similar to that of patients without a history of AF (n = 62, p = .459). CONCLUSIONS: After adjustment for patient characteristics, the long-term prognosis of patients with HFrEF, narrow QRS, and PEAF who underwent AVJA plus CRT was similar to that of a population of patients in SR with similar characteristics.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Heart Failure , Ventricular Dysfunction, Left , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Prospective Studies , Stroke Volume , Treatment Outcome , Ventricular Dysfunction, Left/therapy
20.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Article in English | MEDLINE | ID: mdl-36676690

ABSTRACT

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Subject(s)
Atrial Fibrillation , Pacemaker, Artificial , Humans , Bradycardia/therapy , Atrial Fibrillation/therapy , Treatment Outcome