Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Circulation ; 147(24): 1788-1797, 2023 06 13.
Article in English | MEDLINE | ID: mdl-37061802

ABSTRACT

BACKGROUND: Research suggests NT-proBNP (N-terminal pro-B-type natriuretic peptide) to be a strong predictor of incident atrial fibrillation (AF) and stroke. However, its utility in AF screening remains unknown. The aim of this study was to investigate NT-proBNP as a potential marker for screening efficacy with respect to AF yield and stroke prevention. METHODS: In the LOOP Study (Atrial Fibrillation Detected by Continuous ECG Monitoring Using Implantable Loop Recorder to Prevent Stroke in High-Risk Individuals), 6004 AF-naïve individuals at least 70 years old and with additional stroke risk factors were randomized 1:3 to either screening with an implantable loop recorder (ILR) and initiation of anticoagulation upon detection of AF episodes lasting ≥6 minutes or usual care (control). This post hoc analysis included study participants with available NT-proBNP measurement at baseline. RESULTS: A total of 5819 participants (96.9% of the trial population) were included. The mean age was 74.7 years (SD, 4.1 years) and 47.5% were female. The median NT-proBNP level was 15 pmol/L (interquartile range, 9-28 pmol/L) corresponding to 125 pg/mL (interquartile range, 76-233 pg/mL). NT-proBNP above median was associated with an increased risk of AF diagnosis both in the ILR group (hazard ratio, 1.84 [95% CI, 1.51-2.25]) and the control group (hazard ratio, 2.79 [95% CI, 2.30-3.40]). Participants with NT-proBNP above the median were also at higher risk of clinical events compared with those having lower levels (hazard ratio, 1.21 [95% CI, 0.96-1.54] for stroke or systemic embolism [SE], 1.60 [95% CI, 1.32-1.95] for stroke/SE/cardiovascular death, and 1.91 [95% CI, 1.61-2.26] for all-cause death). Compared with usual care, ILR screening was associated with significant reductions in stroke/SE and stroke/SE/cardiovascular death among participants with NT-proBNP above median (hazard ratio, 0.60 [95% CI, 0.40-0.90] and 0.70 [95% CI, 0.53-0.94], respectively) but not among those with lower levels (Pinteraction=0.029 for stroke/SE and 0.045 for stroke/SE/cardiovascular death). No risk reduction in all-cause death was observed in either NT-proBNP subgroup for ILR versus control (Pinteraction=0.68). Analyzing NT-proBNP as a continuous variable yielded similar findings. CONCLUSIONS: In an older population with additional stroke risk factors, ILR screening for AF was associated with a significant reduction in stroke risk among individuals with higher NT-proBNP levels but not among those with lower levels. These findings should be considered hypothesis generating and warrant further study before clinical implementation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02036450.


Subject(s)
Atrial Fibrillation , Embolism , Stroke , Aged , Female , Humans , Male , Atrial Fibrillation/diagnosis , Biomarkers , Embolism/complications , Natriuretic Peptide, Brain , Peptide Fragments , Stroke/prevention & control
2.
Stroke ; 55(4): 1136-1140, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38456295

ABSTRACT

The bulk of the current knowledge on atrial fibrillation (AF)-associated stroke risk and benefit of oral anticoagulation derives from studies on patients with clinically diagnosed AF. Subclinical AF (SCAF), defined as AF discovered during the interrogation of prolonged heart monitoring, is often asymptomatic and short-lasting, is associated with increased stroke risk compared with sinus rhythm, and may progress to clinical AF. Despite the extensive screening for and treatment of SCAF, especially in secondary stroke prevention, the net benefit of this practice is not established. Recent studies of SCAF have provided new insights: (1) SCAF is extremely common and may sometimes indicate physiological findings, (2) the stroke risk associated with SCAF is lower than that of clinically detected AF, and (3) any benefit on stroke risk may be countered by increased bleeding risk (no net benefit). How should we interpret the latest knowledge in the setting of poststroke AF screening and prevention?


Subject(s)
Atrial Fibrillation , Stroke , Humans , Stroke/diagnosis , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Risk Factors
3.
Eur Heart J Suppl ; 26(Suppl 4): iv19-iv32, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39099577

ABSTRACT

A budget impact analysis estimates the short-term difference between the cost of the current treatment strategy and a new treatment strategy, in this case to implement population screening for atrial fibrillation (AF). The aim of this study is to estimate the financial impact of implementing population-based AF-screening of 75-year-olds compared with the current setting of no screening from a healthcare payer perspective in eight European countries. The net budget impact of AF-screening was estimated in country-specific settings for Denmark, Germany, Ireland, Italy, Netherlands, Serbia, Spain, and Sweden. Country-specific parameters were used to allow for variations in healthcare systems and to reflect the healthcare sector in the country of interest. Similar results can be seen in all countries AF-screening incurs savings of stroke-related costs since AF treatment reduces the number of strokes. However, the increased number of detected AF and higher drug acquisition will increase the drug costs as well as the costs of physician- and control visits. The net budget impact per invited varied from €10 in Ireland to €122 in the Netherlands. The results showed the increased costs of implementing AF-screening were mainly driven by increased drug costs and screening costs. In conclusion, across Europe, though the initial cost of screening and more frequent use of oral anti-coagulants will increase the healthcare payers' costs, introducing population screening for AF will result in savings of stroke-related costs.

4.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37068888

ABSTRACT

AIMS: Insights into subclinical atrial fibrillation (AF) development are warranted to inform the strategies of screening and subsequent clinical management upon AF detection. Hence, this study sought to characterize the onset and progression of subclinical AF with respect to 12-lead electrocardiogram (ECG) parameters. METHODS AND RESULTS: We included AF-naïve individuals aged 70-90 years with additional stroke risk factors who underwent implantable loop recorder (ILR) monitoring in the LOOP Study. Using data from daily ILR recordings and the computerized analysis of baseline ECG, we studied empirically selected ECG parameters for AF detection (≥6 min), cumulative AF burden, long-lasting AF (≥24 h), and AF progression. Of 1370 individuals included, 419 (30.6%) developed AF during follow-up, with a mean cumulative AF burden of 1.5% [95% CI: 1.2-1.8]. Several P-wave-related and ventricular ECG parameters were associated with new-onset AF and with cumulative AF burden in AF patients. P-wave duration (PWD), P-wave terminal force in Lead V1, and interatrial block (IAB) further demonstrated significant associations with long-lasting AF. Among AF patients, we observed an overall reduction in cumulative AF burden over time (IRR 0.70 [95% CI: 0.51-0.96]), whereas IAB was related to an increased risk of progression to AF ≥24 h (HR 1.86 [95% CI: 1.02-3.39]). Further spline analysis also revealed longer PWD to be associated with this progression in AF duration. CONCLUSION: We identified several ECG parameters associated with new-onset subclinical AF detected by ILR. Especially PWD and IAB were robustly related to the onset and the burden of AF as well as progression over time.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/complications , Electrocardiography/methods , Stroke/prevention & control , Risk Factors , Electrodes, Implanted/adverse effects , Interatrial Block , Electrocardiography, Ambulatory
5.
Europace ; 25(1): 6-27, 2023 02 08.
Article in English | MEDLINE | ID: mdl-35894842

ABSTRACT

Despite marked progress in the management of atrial fibrillation (AF), detecting AF remains difficult and AF-related complications cause unacceptable morbidity and mortality even on optimal current therapy. This document summarizes the key outcomes of the 8th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). Eighty-three international experts met in Hamburg for 2 days in October 2021. Results of the interdisciplinary, hybrid discussions in breakout groups and the plenary based on recently published and unpublished observations are summarized in this consensus paper to support improved care for patients with AF by guiding prevention, individualized management, and research strategies. The main outcomes are (i) new evidence supports a simple, scalable, and pragmatic population-based AF screening pathway; (ii) rhythm management is evolving from therapy aimed at improving symptoms to an integrated domain in the prevention of AF-related outcomes, especially in patients with recently diagnosed AF; (iii) improved characterization of atrial cardiomyopathy may help to identify patients in need for therapy; (iv) standardized assessment of cognitive function in patients with AF could lead to improvement in patient outcomes; and (v) artificial intelligence (AI) can support all of the above aims, but requires advanced interdisciplinary knowledge and collaboration as well as a better medico-legal framework. Implementation of new evidence-based approaches to AF screening and rhythm management can improve outcomes in patients with AF. Additional benefits are possible with further efforts to identify and target atrial cardiomyopathy and cognitive impairment, which can be facilitated by AI.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Artificial Intelligence , Early Diagnosis , Consensus , Cognition , Stroke/prevention & control
6.
Cerebrovasc Dis ; 51(3): 403-412, 2022.
Article in English | MEDLINE | ID: mdl-34883489

ABSTRACT

BACKGROUND: Atrial remodeling is associated with future atrial fibrillation (AF) and stroke. AF has been associated with cognitive impairment and cerebral white matter lesions. We wished to investigate the possible direct association between atrial remodeling and cerebrovascular disease in patients with and without AF documented by implantable loop recorder (ILR). METHODS: Cardiac and cerebral magnetic resonance imaging were acquired in a cross-sectional study, including participants ≥70 years of age with stroke risk factors without known AF. Cerebrovascular disease was visually rated using the Fazekas scale and number of lacunar strokes. Left atrial (LA) and ventricular volumes and function were analyzed. Associations between atrial remodeling and cerebrovascular disease were assessed with logistic regression models. The analyses were stratified according to sinus rhythm or any AF during 3 months of continuous ILR monitoring to account for subclinical AF. RESULTS: Of 200 participants investigated, 87% had a Fazekas score ≥1 and 45% had ≥1 lacunar infarct. Within 3 months of ILR monitoring, AF was detected in 28 (14%) participants. For participants with sinus rhythm (n = 172), lower LA passive emptying fraction was associated with Fazekas score after multivariable adjustment (OR [95% CI]: 0.51 [0.27; 0.86] p = 0.02), and increased LA maximum (OR [95% CI]: 1.38 [1.07; 1.82] p = 0.01) and minimum volumes (OR [95% CI]: 1.48 [1.03; 2.17] p = 0.04) were associated with lacunar infarcts. There were no significant associations in patients with AF. CONCLUSION: In AF-free patients, as documented by ILR monitoring, we found an independent association between LA passive emptying fraction and Fazekas score and between atrial volumes and lacunar infarcts.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Cerebrovascular Disorders , Stroke, Lacunar , Stroke , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Cerebrovascular Disorders/complications , Cerebrovascular Disorders/diagnostic imaging , Cross-Sectional Studies , Humans , Magnetic Resonance Imaging , Stroke/complications , Stroke, Lacunar/complications , Stroke, Lacunar/etiology
7.
Eur Heart J ; 42(38): 3979-3988, 2021 10 07.
Article in English | MEDLINE | ID: mdl-34471928

ABSTRACT

AIMS: The aim of this study was to investigate the association between within-individual changes in physical activity and onset of atrial fibrillation (AF). METHODS AND RESULTS: A total of 1410 participants from the general population (46.2% women, mean age 74.7 ± 4.1 years) with risk factors but with no prior AF diagnosis underwent continuous monitoring for AF episodes along with daily accelerometric assessment of physical activity using an implantable loop recorder during ≈3.5 years. The combined duration of monitoring was ≈1.6 million days, where 10 851 AF episodes lasting ≥60 min were detected in 361 participants (25.6%) with a median of 5 episodes (2, 25) each. The median daily physical activity was 112 (66, 168) min/day. A dynamic parameter describing within-individual changes in daily physical activity, i.e. average daily activity in the last week compared to the previous 100 days, was computed and used to model the onset of AF. A 1-h decrease in average daily physical activity was associated with AF onset the next day [odds ratio 1.24 (1.18-1.31)]. This effect was modified by overall level of activity (P < 0.001 for interaction), and the signal was strongest in the tertile of participants with lowest activity overall [low: 1.62 (1.41-1.86), mid: 1.27 (1.16-1.39), and high: 1.10 (1.01-1.19)]. CONCLUSIONS: Within-individual changes in physical activity are associated with the onset of AF episodes as detected by continuous monitoring in a high-risk population. For each person, a 1-h decrease in daily physical activity during the last week increased the odds of AF onset the next day by ≈25%, while the strongest association was seen in the group with the lowest activity overall. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, identifier: NCT02036450.


Subject(s)
Atrial Fibrillation , Aged , Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , Electrocardiography, Ambulatory , Exercise , Female , Humans , Male , Risk Factors
8.
Circulation ; 141(19): 1510-1522, 2020 05 12.
Article in English | MEDLINE | ID: mdl-32114796

ABSTRACT

BACKGROUND: Stroke is an increasing health problem worldwide. Atrial fibrillation (AF) is a major risk factor for stroke, and the attention given to AF screening is rising, as new monitoring technologies emerge. We aimed to evaluate the performance of a large panel of screening strategies and to assess population characteristics associated with diagnostic yield. METHODS: Individuals with stroke risk factors but without AF were recruited from the general population to undergo screening with an implantable loop recorder. New-onset AF lasting ≥6 minutes was adjudicated by senior cardiologists. After continuous monitoring for >3 years, complete day-to-day heart rhythm data sets were reconstructed for every participant, including exact time of onset and termination of all AF episodes. Random sampling was applied to assess the sensitivity and negative predictive value of screening with various simulated screening strategies compared with the implantable loop recorder. The diagnostic yield across strategies and population subgroups was compared by use of nonparametric tests. RESULTS: The rhythm data sets comprised 590 participants enduring a total of 659 758 days of continuous monitoring and 20 110 AF episodes. In these data, a single 10-second ECG yielded a sensitivity (and negative predictive value) of 1.5% (66%) for AF detection, increasing to 8.3% (67%) for twice-daily 30-second ECGs during 14 days and to 11% (68%), 13% (68%), 15% (69%), 21% (70%), and 34% (74%) for a single 24-hour, 48-hour, 72-hour, 7-day, or 30-day continuous monitoring, respectively. AF detection further improved when subsequent screenings were performed or when the same monitoring duration was spread over several periods compared with a single period (eg, three 24-hour monitorings versus one 72-hour monitoring; P<0.0001 for all comparisons). The sensitivity was consistently higher among participants with age ≥75 years, male sex, CHADS2 score >2, or NT-proBNP (N-terminal pro-B-type natriuretic peptide) ≥40 pmol/L and among participants with underlying ≥24-hour AF episodes compared with shorter AF (P<0.0001 for all screening strategies). CONCLUSIONS: In screening for AF among participants with stroke risk factors, the diagnostic yield increased with duration, dispersion, and number of screenings, although all strategies had low yield compared with the implantable loop recorder. The sensitivity was higher among participants who were older, were male, or had higher NT-proBNP. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02036450.


Subject(s)
Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory/instrumentation , Heart Conduction System/physiopathology , Heart Rate , Mass Screening/instrumentation , Remote Sensing Technology/instrumentation , Stroke/epidemiology , Action Potentials , Aged , Aged, 80 and over , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Denmark , Female , Humans , Male , Predictive Value of Tests , Reproducibility of Results , Risk Assessment , Risk Factors , Stroke/diagnosis , Time Factors
9.
Am Heart J ; 242: 15-23, 2021 12.
Article in English | MEDLINE | ID: mdl-34428441

ABSTRACT

AIMS: To study the relationship between subclinical atrial fibrillation (AF) and changes in cognitive function in a large cohort of individuals with stroke risk factors. METHODS: Individuals with no prior AF diagnosis but with risk factors for stroke were recruited to undergo annual cognitive assessment with the Montreal Cognitive Assessment (MoCA) along with implantable loop recorder (ILR) monitoring for AF for 3 years. If AF episodes lasting ≥6 minutes were detected, oral anticoagulation (OAC) treatment was initiated. RESULTS: A total of 1194 participants (55.2 % men, mean age 74.5 (±3.9)) had a combined duration of heart rhythm monitoring of ≈1.3 million days. Among these, 339 participants (28.3%) had adjudicated AF, with a median AF burden of 0.072% (0.02, 0.39), and 324 (96%) initiated OAC. When stratifying the participants into AF burden groups (No AF, AFlow (AF burden <0.25%), and AFhigh, (AF burden >0.25%)), only participants in the AFlow group had a decrease in MoCA score over time (P = .03), although this was not significant after adjustment for stroke risk factors. A subgroup analysis of 175 participants (14.6%) with a MoCA <26 at 3 years found no association to AF diagnosis or burden. CONCLUSIONS: In a high-risk population, subclinical AF detected by continuous monitoring and subsequently treated with OAC was not associated with a significant change in MoCA score over a 3-year period.


Subject(s)
Atrial Fibrillation , Cognitive Dysfunction , Cost of Illness , Monitoring, Physiologic , Aged , Atrial Fibrillation/epidemiology , Cognitive Dysfunction/epidemiology , Female , Humans , Male , Risk Factors , Stroke/epidemiology
10.
Am Heart J ; 219: 117-127, 2020 01.
Article in English | MEDLINE | ID: mdl-31699295

ABSTRACT

BACKGROUND: Recent studies have suggested a high prevalence of subclinical atrial fibrillation (AF) in various patient populations, and interest in AF screening has increased. However, knowledge about episode duration is scarce, and risk factors for short or long subclinical AF episodes have yet to be recognized. The aim of the study was to assess AF by long-term continuous screening and to investigate predictors of episodes lasting ≥6 minutes, ≥5.5 hours, or ≥24 hours, respectively. METHODS: A total of 597 patients aged ≥70 years and diagnosed with ≥1 of hypertension, diabetes, previous stroke, or heart failure were recruited from the general population to receive implantable loop recorder with remote monitoring. Exclusion criteria included history of AF or cardiac implantable electronic device. AF episodes were adjudicated by senior cardiologists. RESULTS: During 40 (37; 42) months of continuous monitoring, AF was detected in 209 (35%) of the patients. The cumulative incidences at 3 years were 33.8% (30.2%-37.8%), 16.1% (13.4%-19.4%), and 5.7% (4.1%-7.9%) for AF episodes lasting ≥6 minutes, ≥5.5 hours, and ≥24 hours, respectively. Slower resting sinus rate and higher body mass index, N-terminal prohormone of brain natriuretic peptide, and troponin T at baseline were independently associated with AF detection. Addition of these markers to a model of sex, age, and comorbidities improved prediction of AF episodes ≥24 hours (time-dependent area under the receiver operating characteristic curve 79% vs 65%, P = .037). CONCLUSIONS: A considerable burden of previously unknown AF was detected when long-term monitoring was applied in at-risk patients. Biomarkers were associated with AF incidence and improved prediction of long AF episodes.


Subject(s)
Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory/instrumentation , Electrodes, Implanted , Aged , Area Under Curve , Atrial Fibrillation/blood , Atrial Fibrillation/epidemiology , Biomarkers/blood , Body Mass Index , C-Reactive Protein/metabolism , Female , Heart Rate , Humans , Incidence , Male , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Time Factors , Troponin T/blood
11.
Europace ; 22(5): 724-731, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32125356

ABSTRACT

AIMS: We aimed to investigate whether left atrial (LA) markers from cardiovascular magnetic resonance (CMR) were able to predict atrial fibrillation (AF) in elderly patients with risk factors for stroke. METHODS AND RESULTS: At baseline, 203 participants with stroke risk factors but without history of AF underwent advanced CMR and received an implantable loop recorder. During a median of 40 (37-42) months of continuous monitoring, incident AF was detected in 79 patients (39%). With regards to CMR markers, a steep increase in incidence rate of AF was seen with LA maximum volume (LAmax) above 55 mL/m2, LA minimum volume (LAmin) above 30 mL/m2, LA total emptying fraction (LA TEF) below 45%, LA active emptying fraction (LA AEF) below 37%, LA strain S below 25%, LA strain A below 17%, and LA strain rate A above -1.7 s-1. After multivariate adjustment, the above-mentioned CMR markers remained associated with AF incidence: hazard ratio (95% confidence interval) 1.25 (1.06-1.48) and 1.51 (1.22-1.87) per 10 mL/m2 increase of LAmax and LAmin, respectively, 1.49 (1.26-1.76) and 1.46 CI (1.25-1.71) per 5% decrease in LA TEF and LA AEF, respectively, 1.23 (1.05-1.44) and 1.56 (1.18-2.06) per 5% decrease in LA strain S and A, respectively, and 2.06 (1.31-3.23) per s-1 increase in LA strain rate A. In prediction analyses, LA functional indices increased area under the receiver operating characteristic curve significantly. CONCLUSION: The risk of AF, including asymptomatic AF, increases significantly with increasing LA volumes and worsening LA function.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Function, Left , Heart Atria/diagnostic imaging , Humans , Magnetic Resonance Imaging
13.
Europace ; 21(7): 1055-1062, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-30843038

ABSTRACT

AIMS: Prolonged corrected QT interval (QTc) might be associated with arrhythmia recurrence after atrial fibrillation (AF) ablation. The effect of short-term amiodarone in this setting remains unknown. This study seeks to quantify short-term amiodarone's impact on QTc, and to investigate QTc and amiodarone treatment as predictors of recurrence of arrhythmia after ablation. METHODS AND RESULTS: The Short-term AMIOdarone treatment after CATheter ablation for atrial fibrillation (AMIO-CAT) trial randomized patients to 8 weeks of oral amiodarone or placebo following AF ablation. Scheduled and symptom-driven 12-lead electrocardiography and 3-day Holter-monitorings were performed. The endpoint was atrial fibrillation, atrial flutter or atrial tachycardia (AF/AT) lasting >30 s. The cut-off for prolonged QTc was 450 ms for men and 460 ms for women. A total of 212 patients were included, of which 108 were randomized to amiodarone and 104 to placebo. From baseline to 1 month QTc in the amiodarone group increased by 27 (±30) ms, while at 6 months QTc had normalized. After 3-months of blanking, new AF/AT recurrence was detected in 63% of patients with prolonged QTc vs. 41% of patients with normal QTc at baseline, and in multivariate Cox regression, prolonged QTc was associated with AF/AT recurrence [hazard ratio (HR) 2.19, P = 0.023]. Among patients with baseline QTc below median, amiodarone treatment decreased the rate of AF/AT recurrences (HR 0.43, P = 0.008). CONCLUSIONS: Amiodarone increased QTc with 27 ms compared to placebo, and this effect decreased rapidly after drug discontinuation. Prolonged QTc at baseline independently predicted AF/AT recurrence, and baseline QTc identified patients who would possibly benefit from short-term amiodarone following ablation.


Subject(s)
Amiodarone/administration & dosage , Anti-Arrhythmia Agents/administration & dosage , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Catheter Ablation/methods , Long QT Syndrome/complications , Long QT Syndrome/drug therapy , Administration, Oral , Combined Modality Therapy , Denmark , Double-Blind Method , Electrocardiography , Female , Humans , Male , Middle Aged , Recurrence
14.
Am Heart J ; 187: 122-132, 2017 May.
Article in English | MEDLINE | ID: mdl-28454796

ABSTRACT

Atrial fibrillation (AF) increases the rate of stroke 5-fold, and AF-related strokes have a poorer prognosis compared with non-AF-related strokes. Atrial fibrillation and stroke constitute an intensifying challenge, and health care organizations are calling for awareness on the topic. Previous studies have demonstrated that AF is often asymptomatic and consequently undiagnosed. The implantable loop recorder (ILR) allows for continuous, long-term electrocardiographic monitoring with daily transmission of arrhythmia information, potentially leading to improvement in AF detection and stroke prevention. METHODS: The LOOP study is an investigator-initiated, randomized controlled trial with 6,000 participants randomized 3:1 to a control group or to receive an ILR with continuous electrocardiographic monitoring. Participants are identified from Danish registries and are eligible for inclusion if 70years or older and previously diagnosed as having at least one of the following conditions: hypertension, diabetes mellitus, heart failure, or previous stroke. Exclusion criteria include history of AF and current oral anticoagulation treatment. When an AF episode lasting ≥6minutes is detected, oral anticoagulation will be initiated according to guidelines. Expected follow-up is 4years. The primary end point is time to stroke or systemic embolism, whereas secondary end points include time to AF diagnosis and death. CONCLUSION: The LOOP study will evaluate health benefits and cost-effectiveness of ILR as a screening tool for AF to prevent stroke in patients at risk. Secondary objectives include identification of risk factors for the development of AF and characterization of arrhythmias in the population. The trial holds the potential to influence the future of stroke prevention.


Subject(s)
Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory , Stroke/prevention & control , Aged , Aged, 80 and over , Atrial Fibrillation/physiopathology , Cognition Disorders/etiology , Cost-Benefit Analysis , Electrocardiography, Ambulatory/economics , Female , Humans , Male , Quality of Life , Research Design , Risk Factors
15.
Blood Press ; 26(1): 54-63, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27662908

ABSTRACT

OBJECTIVE: To investigate the influence of cardiovascular risk factors, including fasting plasma glucose (FPG), on the association between electrocardiographic (ECG) and echocardiographic left ventricular hypertrophy (LVH) in an elderly population. METHODS: We tested cross-sectional associations between electrocardiographic and echocardiographic LVH, defining LVH according to the Sokolow-Lyon voltage combination, Cornell voltage-duration product, or left ventricular mass index (LVMI). Differences between standardized LVMI and Sokolow-Lyon voltage combination or Cornell voltage-duration product (absolute value/cut-off value for LVH) were used as outcome variables in order to identify explanatory variables associated with diagnostic discrepancies between ECG and echocardiography. RESULTS: Of the 1382 subjects included, 77% did not display any signs of LVH, 6% had LVH defined by ECG only, 13% had LVH defined by echocardiography only, and 5% had LVH on both ECG and echocardiography. Older subjects and those with higher blood pressure and RWT were more likely to have a relatively greater LVMI on echocardiography than that predicted on ECG (odds ratio: 1.65 per 10 years (95% confidence interval (CI): 1.27-2.15), p = .0002, odds ratio: 1.17 per 10 mmHg (95% CI: 1.09-1.25), p < .0001, and odds ratio: 1.21 per 0.10 (95% CI: 1.02-1.42), p = .03). In addition, discrepancy was also seen in females and subjects receiving antihypertensive medication (odds ratio: 1.41 (95% CI: 1.04-1.89), p = .03 and odds ratio: 1.41 (95% CI: 1.06-1.87), p = .02), but FPG did not independently influence discrepancy between ECG and echocardiography. CONCLUSION: Age, blood pressure, female sex, greater RWT and use of antihypertensive medication were associated with a greater risk of non-consistency between LVH determined by ECG and echocardiography.


Subject(s)
Blood Glucose/metabolism , Blood Pressure , Echocardiography , Electrocardiography , Hypertrophy, Left Ventricular , Aged , Female , Humans , Hypertrophy, Left Ventricular/blood , Hypertrophy, Left Ventricular/diagnostic imaging , Hypertrophy, Left Ventricular/physiopathology , Male , Middle Aged
16.
Open Heart ; 11(1)2024 May 07.
Article in English | MEDLINE | ID: mdl-38719497

ABSTRACT

BACKGROUND: The treatment of pulmonary hypertension (PH) has improved rapidly in recent decades. There is increasing evidence to support the role of early intervention and treatment in affecting clinical outcomes in PH. OBJECTIVES: To assess treatment effects before and after the escalation of specific PH treatments using continuous heart monitoring with a Reveal LINQ loop recorder. METHODS: Patients were compared before and after treatment escalation. Treatment escalation was defined as an additional pulmonary arterial hypertension (PAH) drug, pulmonary endarterectomy, percutaneous balloon angioplasty or bilateral lung transplantation. Specifically, changes in heart rate variability (HRV), heart rate (HR) and physical activity were assessed. RESULTS: In this prospective study, 41 patients (27 with PAH and 14 with chronic thromboembolic pulmonary hypertension (CTEPH)) were enrolled. Among them, 15 (36.6%) patients underwent PH treatment escalation. Prior to escalation, patients were monitored for a median of 100 (range: 68-100) days and after therapy escalation for a median duration of 165 (range: 89-308) days. In the escalation group, there was a significant increase in HRV, physical activity indexed by daytime HR and a significant decrease in nighttime HR assessed at baseline and after treatment escalation in both the PAH and CTEPH groups. This was paralleled by significant improvements in WHO functional class, 6-min walking distance and N-terminal pro-b-type natriuretic peptide. CONCLUSIONS: This is the first study to demonstrate an association between specific PH therapies and changes in HRV, HR nighttime and physical activity. This indicates the potential of continuous monitoring in the evaluation of treatment effects in PH.


Subject(s)
Heart Rate , Hypertension, Pulmonary , Humans , Female , Male , Middle Aged , Prospective Studies , Heart Rate/physiology , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/therapy , Treatment Outcome , Endarterectomy/methods , Aged , Antihypertensive Agents/therapeutic use , Time Factors , Angioplasty, Balloon/methods , Adult , Lung Transplantation , Electrocardiography, Ambulatory/methods , Pulmonary Artery/physiopathology
17.
Article in English | MEDLINE | ID: mdl-39168942

ABSTRACT

BACKGROUND: Advances in medical treatment and outcomes in implantable cardioverter-defibrillator (ICD) recipients incentivize a need for improved candidate selection and identification of risk factors for ICD therapy. We examined contemporary rates of and risk factors for ICD therapy. METHODS: Patients with ICD for primary (PP) or secondary prevention (SP), implanted between January 2010 and December 2020, were followed for appropriate and inappropriate incident and recurrent shock. RESULTS: Overall, 2998 patients (mean age 61.8 ± 12.7 years, 20% female, 73% ICD carriers, and 47.1% SP) were analyzed with a median follow-up of 4.3 (interquartile range (IQR) 2.1-7.4) years. A total of 426/2998 (14.2%) patients had shock; 364/2998 (12.1%) had appropriate and 82/2998 (2.7%) inappropriate shock, with annualized event rates of 2.34 (2.11-2.59) and 0.49 (0.39-0.61) per 100 person-years, respectively. Of those with shock, 133/364 (36.5%) experienced recurrent appropriate shock and 8/364 (2.2%) received recurrent inappropriate shock, with event rates of 10.57 (8.85-12.53) and 0.46 (0.20-0.92), respectively. In multivariable analyses, female sex was associated with a reduced risk of incident appropriate shock (hazard ratio 0.69 [95% confidence interval 0.52; 0.91]). Of other variables, only revascularization status was associated with recurrent appropriate shock in PP, and CRT-D with recurrent appropriate shock in the overall cohort. CONCLUSION: One in eight ICD recipients received appropriate shock 2-7 years after guideline-directed implantation. More than one-third of patients with a first shock experienced recurrent shock. Few clinical variables showed potential in predicting shocks, illustrating a need for more advanced tools to select candidates for implantation.

18.
TH Open ; 8(1): e19-e30, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38197016

ABSTRACT

Background Atrial fibrillation (AF) prevalence is rising; however, data on the bleeding risks associated with the detection of subclinical AF are needed. Objective Our objective was to determine the bleeding increment associated with implantable loop recorder (ILR) screening for subclinical AF and subsequent anticoagulation initiation compared with usual care. Methods This post hoc study utilized LOOP trial data from 6,004 elderly patients with stroke risks randomized to either ILR ( n = 1,503) or usual care ( n = 4,503). The mean follow-up time was 64.5 months, and none were lost to follow-up. The primary exposure was the initiation of oral anticoagulation, and the main outcome was the risk of major bleeding events following initiation of oral anticoagulants (OACs), determined by time-dependent cox regression. Second, we investigated antithrombotic prescription patterns and major bleeding events after antiplatelet treatment and in subgroups. Results OAC was initiated in 1,019 participants with a mean age (years) of 78.8 (± 4.67) in control versus 77.0 (± 4.84) in ILR, p < 0.0001. Altogether did 202 participants end or pause OAC treatment. Among AF patients (n = 910) had 40 (28%) completely ended OAC and 105 (72%) temporarily paused OAC during follow-up. Major bleeding events totaled 221 (3.7%). Forty-seven major bleeding events followed an OAC initiation in 1,019 participants (4.6%); 26 versus 21 events in the control and ILR groups, respectively. The hazard ratio (HR) for major bleeding after OAC initiation compared with before initiation was 2.08 (1.50-2.90) p < 0.0001 overall, 2.81 (1.82-4.34) p < 0.0001 for control and 1.32 (0.78-2.23) p = 0.31 for the ILR group ( p = 0.07 for interaction). Antiplatelet treatment resulted in an overall adjusted HR of 1.3 (0.96-1.75) p = 0.09. For OAC users aged ≥75 years in the ILR group, the rate of major bleeding was 1.73 (0.92-2.96) compared with 0.84 (0.36-1.66) for an age <75 years, and the rate of the corresponding control subgroup aged ≥75 years was 2.20 (1.23-3.63) compared with 1.64 (0.82-2.93) for an age <75 years. Conclusion The individual risk of major bleeding increased twofold after initiation of oral anticoagulation for all patients in this study. However, the patients screened for subclinical AF did not have a higher bleeding risk after initiation of anticoagulation compared with those in usual care. Trial Registration: The LOOP study is registered at ClinicalTrials.gov, identifier: NCT020364 50.

19.
Int J Cardiovasc Imaging ; 40(3): 591-599, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38245893

ABSTRACT

Epicardial adipose tissue (EAT) has endocrine and paracrine functions and has been associated with metabolic and cardiovascular disease. This study aimed to investigate the association between EAT, determined by cardiac magnetic resonance imaging (CMR), and incident atrial fibrillation (AF) following long-term continuous heart rhythm monitoring by implantable loop recorder (ILR). This study is a sub-study of the LOOP study. In total, 203 participants without a history of AF received an ILR and underwent advanced CMR. All participants were at least 70 years of age at inclusion and had at least one of the following conditions: hypertension, diabetes, previous stroke, or heart failure. Volumetric measurements of atrial- and ventricular EAT were derived from CMR and the time to incident AF was subsequently determined. A total of 78 participants (38%) were diagnosed with subclinical AF during a median of 40 (37-42) months of continuous monitoring. In multivariable Cox regression analyses adjusted for age, sex, and various comorbidities, we found EAT indexed to body surface area to be independently associated with the time to AF with hazard ratios (95% confidence intervals) up to 2.93 (1.36-6.34); p = 0.01 when analyzing the risk of new-onset AF episodes lasting ≥ 24 h. Atrial EAT assessed by volumetric measurements on CMR images was significantly associated with the incident AF episodes as detected by ILR.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/complications , Epicardial Adipose Tissue , Predictive Value of Tests , Magnetic Resonance Imaging , Heart Atria , Adipose Tissue/diagnostic imaging
20.
Circ Cardiovasc Imaging ; 17(3): e016197, 2024 03.
Article in English | MEDLINE | ID: mdl-38440875

ABSTRACT

BACKGROUND: Left atrial (LA) speckle tracking provides detailed information on atrial function. Its utility for predicting subclinical atrial fibrillation (SCAF) is unclear. Therefore, we sought to investigate whether LA strain measures could predict SCAF detected by long-term continuous rhythm monitoring. METHODS: This was an echocardiographic substudy of the LOOP study, where elderly at risk of stroke were randomized to receive a loop recorder (Reveal LINQ) or control. Participants who received a loop recorder were included in this analysis. Echocardiography included LA reservoir, conduit, and contraction strain. Participants were followed with continuous rhythm monitoring for SCAF (≥6 minutes). Cox proportional hazards regression was applied to adjust for atrial fibrillation risk factors. RESULTS: In total, 956 participants were eligible for analysis. Median continuous rhythm monitoring was 35 months (IQR, 20-40 months), during which 278 (29%) were diagnosed with SCAF. The mean age was 74 years, 56% were male, median CHA2DS2-VASc-score was 4. LA reservoir strain was an independent predictor of SCAF after multivariable adjustments (HR, 1.04 [1.02-1.05], per 1% decrease) and so was contraction strain. The findings were unchanged in competing risk analyses and in participants with normal LA size and diastolic function. Participants with low reservoir strain (<33%) had a significantly higher risk of SCAF compared with those with high reservoir strain (incidence rate, 14.5 [12.4-16.9] versus 9.8 [8.2-11.8] events/100 person-years). The same was noted for low versus high contraction strain. CONCLUSIONS: LA reservoir and contraction strain are independent predictors of SCAF in elderly at risk of stroke. This also applies to individuals with normal LA size and diastolic function. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02036450.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Male , Aged , Female , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/complications , Heart Atria/diagnostic imaging , Echocardiography , Stroke/etiology , Stroke/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL