Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Language
Publication year range
1.
Lasers Surg Med ; 55(10): 900-911, 2023 12.
Article in English | MEDLINE | ID: mdl-37870158

ABSTRACT

OBJECTIVES: The study aimed to improve the safety and accuracy of laser osteotomy (bone surgery) by integrating optical feedback systems with an Er:YAG laser. Optical feedback consists of a real-time visual feedback system that monitors and controls the depth of laser-induced cuts and a tissue sensor differentiating tissue types based on their chemical composition. The developed multimodal feedback systems demonstrated the potential to enhance the safety and accuracy of laser surgery. MATERIALS AND METHODS: The proposed method utilizes a laser-induced breakdown spectroscopy (LIBS) system and long-range Bessel-like beam optical coherence tomography (OCT) for tissue-specific laser surgery. The LIBS system detects tissue types by analyzing the plasma generated on the tissue by a nanosecond Nd:YAG laser, while OCT provides real-time monitoring and control of the laser-induced cut depth. The OCT system operates at a wavelength of 1288 ± 30 nm and has an A-scan rate of 104.17 kHz, enabling accurate depth control. Optical shutters are used to facilitate the integration of these multimodal feedback systems. RESULTS: The proposed system was tested on five specimens of pig femur bone to evaluate its functionality. Tissue differentiation and visual depth feedback were used to achieve high precision both on the surface and in-depth. The results showed successful real-time tissue differentiation and visualization without any visible thermal damage or carbonization. The accuracy of the tissue differentiation was evaluated, with a mean absolute error of 330.4 µm and a standard deviation of ±248.9 µm, indicating that bone ablation was typically stopped before reaching the bone marrow. The depth control of the laser cut had a mean accuracy of 65.9 µm with a standard deviation of ±45 µm, demonstrating the system's ability to achieve the pre-planned cutting depth. CONCLUSION: The integrated approach of combining an ablative laser, visual feedback (OCT), and tissue sensor (LIBS) has significant potential for enhancing minimally invasive surgery and warrants further investigation and development.


Subject(s)
Laser Therapy , Lasers, Solid-State , Swine , Animals , Feedback , Osteotomy , Laser Therapy/methods , Lasers, Solid-State/therapeutic use , Light
2.
Sensors (Basel) ; 19(20)2019 Oct 11.
Article in English | MEDLINE | ID: mdl-31614587

ABSTRACT

Currently available groundwater flow prediction tools and methods are limited by insufficient spatial resolution of subsurface data and the unknown local heterogeneity. In this field study, fiber Bragg grating (FBG) sensors were installed in an extraction well field to investigate its potential to measure groundwater flow velocity. Reference in-situ pore pressure and temperature measurements were used to identify possible sources of FBG responses. FBG strain sensors were able to detect soil consolidation caused by groundwater extraction from 250 m distance. The results show that FBG responses were influenced by interface friction between soil and FBG packaging. FBG packaging slipped in soil and the effect was more pronounced during higher groundwater flow around a nearby well. These FBG fibers could be applied for indirect flow monitoring that does not require any tracer and provide real-time and long-term data during regular operation of extraction wells.

3.
Sensors (Basel) ; 19(7)2019 Apr 11.
Article in English | MEDLINE | ID: mdl-30978952

ABSTRACT

An understanding of groundwater flow near drinking water extraction wells is crucial when it comes to avoiding well clogging and pollution. A promising new approach to groundwater flow monitoring is the deployment of a network of optical fibers with fiber Bragg grating (FBG) sensors. In preparation for a field experiment, a laboratory scale aquifer was constructed to investigate the feasibility of FBG sensors for this application. Multiparameter FBG sensors were able to detect changes in temperature, pressure, and fiber shape with sensitivities influenced by the packaging. The first results showed that, in a simulated environment with a flow velocity of 2.9 m/d, FBG strain effects were more pronounced than initially expected. FBG sensors of a pressure-induced strain implemented in a spatial array could form a multiplexed sensor for the groundwater flow direction and magnitude. Within the scope of this research, key technical specifications of FBG interrogators for groundwater flow sensing were also identified.

4.
Phys Chem Chem Phys ; 18(24): 16281-92, 2016 Jun 28.
Article in English | MEDLINE | ID: mdl-27253197

ABSTRACT

In this experiment liquid water is subject to an inhomogeneous electric field (∇(2)Ea≈ 10(10) V m(2)) using a high voltage (20 kV) point-plane electrode system. Using interferometry it was found that the application of a strong electric field gradient to water generates local changes in the refractive index of the liquid, polarizes the surface and creates a downward moving electro-convective jet. A maximum temperature difference of 1 °C is measured in the immediate vicinity of the point electrode. Raman spectroscopy performed on water reveals an enhancement of the vibrational collective modes (3250 cm(-1)) as well as an increase in the local mode (3490 cm(-1)) energy. This bimodal enhancement indicates that the spectral changes are not due to temperature changes. The intense field gradient thus establishes an excited subpopulation of vibrational oscillators far from thermal equilibrium. Delocalization of the collective vibrational mode spatially expands this excited population beyond the microscale. Hindered rotational freedom due to electric field pinning of molecular dipoles retards the heat flow and generates a chemical potential gradient. These changes are responsible for the observed changes in the refractive index and temperature. It is demonstrated that polar liquids can thus support local non-equilibrium thermodynamic transient states critical to biochemical and environmental processes.

SELECTION OF CITATIONS
SEARCH DETAIL