Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 68
Filter
Add more filters

Publication year range
1.
Opt Express ; 26(5): 6294-6301, 2018 Mar 05.
Article in English | MEDLINE | ID: mdl-29529821

ABSTRACT

Warm dense conditions in titanium foils irradiated with intense femtosecond laser pulses are diagnosed using an x-ray imaging spectroscopy technique. The line shapes of radially resolved titanium Kα spectra are measured with a toroidally bent GaAs crystal and an x-ray charge-coupled device. Measured spectra are compared with the K-shell emissions modeled using an atomic kinetics - spectroscopy simulation code. Kα line shapes are strongly affected by warm (5-40 eV) bulk electron temperatures and imply multiple temperature distributions in the targets. The spatial distribution of temperature is dependent on the target thickness, and a thin target shows an advantage to generate uniform warm dense conditions in a large area.

2.
Phys Rev Lett ; 113(18): 184801, 2014 Oct 31.
Article in English | MEDLINE | ID: mdl-25396373

ABSTRACT

We report on a novel compact laser-driven neutron source with an unprecedented short pulse duration (<50 ps) and high peak flux (>10(18) n/cm(2)/s), an order of magnitude higher than any existing source. In our experiments, high-energy electron jets are generated from thin (<3 µm) plastic targets irradiated by a petawatt laser. These intense electron beams are employed to generate neutrons from a metal converter. Our method opens venues for enhancing neutron radiography contrast and for creating astrophysical conditions of heavy element synthesis in the laboratory.

3.
Phys Rev Lett ; 111(8): 082502, 2013 Aug 23.
Article in English | MEDLINE | ID: mdl-24010431

ABSTRACT

The plasma astrophysical S factor for the 3He(d,p)4He fusion reaction was measured for the first time at temperatures of few keV, using the interaction of intense ultrafast laser pulses with molecular deuterium clusters mixed with 3He atoms. Different proportions of D2 and 3He or CD4 and 3He were mixed in the gas target in order to allow the measurement of the cross section for the 3He(d,p)4He reaction. The yield of 14.7 MeV protons from the 3He(d,p)4He reaction was measured in order to extract the astrophysical S factor at low energies. Our result is in agreement with other S factor parametrizations found in the literature.

4.
Phys Rev Lett ; 111(5): 055002, 2013 Aug 02.
Article in English | MEDLINE | ID: mdl-23952411

ABSTRACT

Two different methods have been employed to determine the plasma temperature in a laser-cluster fusion experiment on the Texas Petawatt laser. In the first, the temperature was derived from time-of-flight data of deuterium ions ejected from exploding D(2) or CD(4) clusters. In the second, the temperature was measured from the ratio of the rates of two different nuclear fusion reactions occurring in the plasma at the same time: D(d,(3)He)n and (3)He(d,p)(4)He. The temperatures determined by these two methods agree well, which indicates that (i) the ion energy distribution is not significantly distorted when ions travel in the disassembling plasma; (ii) the kinetic energy of deuterium ions, especially the "hottest part" responsible for nuclear fusion, is well described by a near-Maxwellian distribution.

5.
Phys Rev Lett ; 109(12): 126803, 2012 Sep 21.
Article in English | MEDLINE | ID: mdl-23005973

ABSTRACT

We measured a change in the current transport of an antenna-coupled, multigate, GaAs/AlGaAs field-effect transistor when terahertz electromagnetic waves irradiated the transistor and attribute the change to bolometric heating of the electrons in the two dimensional electron channel. The observed terahertz absorption spectrum indicates coherence between plasmons excited under adjacent biased device gates. The experimental results agree quantitatively with a theoretical model we developed that is based on a generalized plasmonic transmission line formalism and describes an evolution of the plasmonic spectrum with increasing electron density modulation from homogeneous to the crystal limit. These results demonstrate an electronically induced and dynamically tunable plasmonic band structure.

6.
Rev Sci Instrum ; 93(6): 063103, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35777994

ABSTRACT

A new type of compact high-resolution high-sensitivity gamma-ray spectrometer for short-pulse intense gamma-rays (250 keV to 50 MeV) has been developed by combining the principles of scintillators and attenuation spectrometers. The first prototype of this scintillator attenuation spectrometer (SAS) was tested successfully in Trident laser experiments at LANL. Later versions have been used extensively in the Texas Petawatt laser experiments in Austin, TX, and more recently in OMEGA-EP laser experiments at LLE, Rochester, NY. The SAS is particularly useful for high-repetition-rate laser applications. Here, we give a concise description of the design principles, capabilities, and sample preliminary results of the SAS.

7.
Rev Sci Instrum ; 92(1): 013510, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33514225

ABSTRACT

In pump-probe experiments with an X-ray Free Electron Laser (XFEL) and a high-power optical laser, spatial overlap of the two beams must be ensured to probe a pumped area with the x-ray beam. A beam monitoring diagnostic is particularly important in short-pulse laser experiments where a tightly focused beam is required to achieve a relativistic laser intensity for generation of energetic particles. Here, we report the demonstration of on-shot beam pointing measurements of an XFEL and a terawatt class femtosecond laser using 2D monochromatic Kα imaging at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source. A thin solid titanium foil was irradiated by a 25-TW laser for fast electron isochoric heating, while a 7.0 keV XFEL beam was used to probe the laser-heated region. Using a spherical crystal imager (SCI), the beam overlap was examined by measuring 4.51 keV Kα x rays produced by laser-accelerated fast electrons and the x-ray beam. Measurements were made for XFEL-only at various focus lens positions, laser-only, and two-beam shots. Successful beam overlapping was observed on ∼58% of all two-beam shots for 10 µm thick samples. It is found that large spatial offsets of laser-induced Kα spots are attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. By applying the Kα measurements to x-ray Thomson scattering measurements, we found an optimum x-ray beam spot size that maximizes scattering signals. Monochromatic x-ray imaging with the SCI could be used as an on-shot beam pointing monitor for XFEL-laser or multiple short-pulse laser experiments.

8.
Nat Commun ; 11(1): 6174, 2020 12 02.
Article in English | MEDLINE | ID: mdl-33268784

ABSTRACT

Radiographic imaging with x-rays and protons is an omnipresent tool in basic research and applications in industry, material science and medical diagnostics. The information contained in both modalities can often be valuable in principle, but difficult to access simultaneously. Laser-driven solid-density plasma-sources deliver both kinds of radiation, but mostly single modalities have been explored for applications. Their potential for bi-modal radiographic imaging has never been fully realized, due to problems in generating appropriate sources and separating image modalities. Here, we report on the generation of proton and x-ray micro-sources in laser-plasma interactions of the focused Texas Petawatt laser with solid-density, micrometer-sized tungsten needles. We apply them for bi-modal radiographic imaging of biological and technological objects in a single laser shot. Thereby, advantages of laser-driven sources could be enriched beyond their small footprint by embracing their additional unique properties, including the spectral bandwidth, small source size and multi-mode emission.


Subject(s)
Gryllidae/ultrastructure , Multimodal Imaging/methods , Radiography/methods , Animals , Lasers , Multimodal Imaging/instrumentation , Protons , Radiography/instrumentation , X-Rays
9.
J Phys Condens Matter ; 21(19): 195803, 2009 May 13.
Article in English | MEDLINE | ID: mdl-21825498

ABSTRACT

A plasmonic terahertz detector that integrates a voltage-controlled planar barrier into a grating gated GaAs/AlGaAs high electron mobility transistor has been fabricated and experimentally characterized. The plasmonic response at fixed grating gate voltage has a full width at half-maximum of 40 GHz at ∼405 GHz. Substantially increased responsivity is achieved by introducing an independently biased narrow gate that produces a lateral potential barrier electrically in series with the resonant grating gated region. DC electrical characterization in conjunction with bias-dependent terahertz responsivity and time constant measurements indicate that a hot electron bolometric effect is the dominant response mechanism at 20 K.

10.
Rev Sci Instrum ; 90(8): 083302, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31472598

ABSTRACT

Calibrated diagnostics for energetic particle detection allow for the systematic study of charged particle sources. The Fujifilm BAS-TR imaging plate (IP) is a reusable phosphorescent detector for radiation applications such as x-ray and particle beam detection. The BAS-TR IP has been absolutely calibrated to many low-Z (low proton number) ions, and extending these calibrations to the mid-Z regime is beneficial for the study of laser-driven ion sources. The Texas Petawatt Laser was used to generate energetic ions from a 100 nm titanium foil, and charge states Ti10+ through Ti12+, ranging from 6 to 27 MeV, were analyzed for calibration. A plastic detector of CR-39 with evenly placed slots was mounted in front of the IP to count the number of ions that correspond with the IP levels of photo-stimulated luminescence (PSL). A response curve was fitted to the data, yielding a model of the PSL signal vs ion energy. Comparisons to other published response curves are also presented, illustrating the trend of PSL/nucleon decreasing with increasing ion mass.

11.
Bone Joint J ; 100-B(11): 1416-1423, 2018 11.
Article in English | MEDLINE | ID: mdl-30418054

ABSTRACT

AIMS: The aim of this study was to assess the quality and scope of the current cost-effectiveness analysis (CEA) literature in the field of hand and upper limb orthopaedic surgery. MATERIALS AND METHODS: We conducted a systematic review of MEDLINE and the CEA Registry to identify CEAs that were conducted on or after 1 January 1997, that studied a procedure pertaining to the field of hand and upper extremity surgery, that were clinical studies, and that reported outcomes in terms of quality-adjusted life-years. We identified a total of 33 studies that met our inclusion criteria. The quality of these studies was assessed using the Quality of Health Economic Analysis (QHES) scale. RESULTS: The mean total QHES score was 82 (high-quality). Over time, a greater proportion of these studies have demonstrated poorer QHES quality (scores < 75). Lower-scoring studies demonstrated several deficits, including failures in identifying reference perspectives, incorporating comparators and sensitivity analyses, discounting costs and utilities, and disclosing funding. CONCLUSION: It will be important to monitor the ongoing quality of CEA studies in orthopaedics and ensure standards of reporting and comparability in accordance with Second Panel recommendations. Cite this article: Bone Joint J 2018;100-B:1416-23.


Subject(s)
Orthopedic Procedures/economics , Upper Extremity/surgery , Cost-Benefit Analysis , Hand/surgery , Humans , Orthopedic Procedures/methods , Quality-Adjusted Life Years , Registries , Research Design
12.
Aust Dent J ; 2018 Jun 07.
Article in English | MEDLINE | ID: mdl-29878377

ABSTRACT

BACKGROUND: Oral and dental disease is a major cause of long-term morbidity following allogeneic blood and marrow transplantation (Allo-BMT). This study aimed to describe the extent and range of oral and dental complications in BMT recipients and to identify gaps in service provision provided to this high-risk group. METHODS: Participants were Allo-BMT recipients, aged >18 years, and received transplants between 2000 and 2012 in NSW. They completed seven surveys, the purpose-designed Sydney Post-BMT Study survey and six other validated instruments. RESULTS: Of 441 respondents, many reported dry mouth (45.1%), dental caries (36.7%), mouth ulcers (35.3%), oral GVHD (35.1%), gingivitis (16.2%), tooth abscess (6.1%) and oral cancer (1.5%). Regular dental visits were reported by 66.2% of survivors. Middle-high income, older age and geographic location showed a positive association with regular dental visits. Of those who did not visit the dentist regularly, 37% stated they did not feel it necessary, 36% reported cost and 20% stated it was not advised by the treating team. CONCLUSION: Despite oral complications commonly occurring after Allo-BMT, many survivors receive inadequate dental care. These results emphasize the need for improved oral health education, the importance of regular dental checks and improvement in the delivery of dental health services for BMT survivors.

13.
Phys Rev E Stat Nonlin Soft Matter Phys ; 76(5 Pt 2): 056402, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18233771

ABSTRACT

We present measurements of the fast-electron-relaxation time in short-pulse (0.5 ps) laser-solid interactions for laser intensities of 10(17), 10(18), and 10(19) Wcm2, using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. We find that the laser coupling to hot electrons increases as the laser intensity becomes relativistic, and that the thermalization of fast electrons occurs over time scales on the order of 10 ps at all laser intensities. The experimental data are analyzed using a combination of models that include Kalpha generation, collisional coupling, and plasma expansion.

14.
Phys Rev E ; 95(3-1): 031201, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28415304

ABSTRACT

We present equation of state (EOS) measurements of solid-density copper heated to 5-10 eV. A copper sample was heated isochorically by hydrogen ions accelerated from an adjacent foil by a high intensity pulsed laser, and probed optically. The measured temperature and expansion are compared against simulations using the most up-to-date wide range EOS tables available.

15.
Phys Rev E Stat Nonlin Soft Matter Phys ; 74(1 Pt 2): 016403, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16907194

ABSTRACT

We have studied experimentally the angular distributions of fusion neutrons from plasmas of multi-keV ion temperature, created by 40 fs, multi-TW laser pulses in dense plumes of D2 and CD4 clusters. A slight anisotropy in the neutron emission is observed. We attribute this anisotropy to the fact that the differential cross section for DD fusion is anisotropic even at low collision energies, and this, coupled with the geometry of the gas jet target, leads to beam-target neutrons that are slightly directed. The qualitative features of this anisotropy are confirmed by Monte Carlo simulations.

16.
Bone Marrow Transplant ; 51(10): 1361-1368, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27214081

ABSTRACT

Allogeneic haematopoietic stem cell transplantation (allo-HSCT) entails long-term morbidities that impair survivors' quality of life through broad physical and psychosocial sequelae. Current data and survival measurements may be inadequate for contemporary Australian allo-HSCT recipients. This study sought to comprehensively describe survivorship in an up-to-date, local setting through validated measurements and a novel questionnaire designed to complement and address limitations of current instruments. All adults who received an allo-HSCT between 2000 and 2012 in New South Wales were eligible and included, if alive, those literate and consenting to the study, which encompassed seven survey instruments. Four hundred and forty-three survivors participated, which is 76% of contactable (n=583) and 66% of eligible survivors (n= 669). Chronic GVHD (cGVHD) and co-morbidity rates were similar to published data. Noteworthy results include prevalent sexual dysfunction (66% females, 52% males), loss of income (low income increased from 21 to 36%, P<0.001) and employment (full-time employment fell from 64 to 33%, P<0.001), suboptimal vaccination (31% complete), and health screening (≈50%). Risk factors for poor vaccination and health screening were cGVHD, younger age, less education, rural/regional residence and transplantation <2 years. This study suggests that improvement in survivorship may necessitate structural changes in the current delivery of health services.


Subject(s)
Hematopoietic Stem Cell Transplantation/psychology , Quality of Life , Survivors/psychology , Adult , Aged , Delivery of Health Care/standards , Female , Graft vs Host Disease , Hematopoietic Stem Cell Transplantation/adverse effects , Humans , Male , Middle Aged , New South Wales , Surveys and Questionnaires , Transplantation, Homologous , Young Adult
17.
Phys Rev E ; 94(3-1): 033208, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27739766

ABSTRACT

We report on experiments irradiating isolated plastic spheres with a peak laser intensity of 2-3×10^{20}Wcm^{-2}. With a laser focal spot size of 10 µm full width half maximum (FWHM) the sphere diameter was varied between 520 nm and 19.3 µm. Maximum proton energies of ∼25 MeV are achieved for targets matching the focal spot size of 10 µm in diameter or being slightly smaller. For smaller spheres the kinetic energy distributions of protons become nonmonotonic, indicating a change in the accelerating mechanism from ambipolar expansion towards a regime dominated by effects caused by Coulomb repulsion of ions. The energy conversion efficiency from laser energy to proton kinetic energy is optimized when the target diameter matches the laser focal spot size with efficiencies reaching the percent level. The change of proton acceleration efficiency with target size can be attributed to the reduced cross-sectional overlap of subfocus targets with the laser. Reported experimental observations are in line with 3D3V particle in cell simulations. They make use of well-defined targets and point out pathways for future applications and experiments.

18.
Phys Rev E Stat Nonlin Soft Matter Phys ; 72(3 Pt 2): 036408, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16241580

ABSTRACT

The compact multipulse terawatt (COMET) laser facility at LLNL was used to irradiate Al-coated 2-50 microm Ti foils with approximately 10(19) W cm(-2) , 500 fs, 3-6 J laser pulses. Laser-plasma interactions on the front side of the target generate hot electrons with sufficient energy to excite inner-shell electrons in Ti, creating Kalpha emission which has been measured using a focusing spectrometer with spatial resolution aimed at the back surface of the targets. The spatial extent of the emission varies with target thickness. The high spectral resolution (lambda/Deltalambda approximately equal to 3800) is sufficient to measure broadening of the Kalpha emission feature due to the emergence of blueshifted satellites from ionized Ti in a heated region of the target. A self-consistent-field model is used to spectroscopically diagnose thermal electron temperatures up to 40 eV in the strongly coupled Ti plasmas.

19.
Sci Rep ; 5: 13968, 2015 Sep 14.
Article in English | MEDLINE | ID: mdl-26364764

ABSTRACT

We report results of new pair creation experiments using ~100 Joule pulses of the Texas Petawatt Laser to irradiate solid gold and platinum targets, with intensities up to ~1.9 × 10(21) W.cm(-2) and pulse durations as short as ~130 fs. Positron to electron (e+/e-) ratios >15% were observed for many thick disk and rod targets, with the highest e+/e- ratio reaching ~50% for a Pt rod. The inferred pair yield was ~ few ×10(10) with emerging pair density reaching ~10(15)/cm(3) so that the pair skin depth becomes < pair jet transverse size. These results represent major milestones towards the goal of creating a significant quantity of dense pair-dominated plasmas with e+/e- approaching 100% and pair skin depth ≪ pair plasma size, which will have wide-ranging applications to astrophysics and fundamental physics.

20.
Am J Clin Pathol ; 78(5): 783-5, 1982 Nov.
Article in English | MEDLINE | ID: mdl-7137124

ABSTRACT

Neuroendocrine (Merkel cell) carcinoma of the skin is usually a tumor found in elderly individuals. Microscopically, the tumor is a small cell carcinoma that involves primarily the dermis. The dominant ultrastructural features are the presence of short cell processes containing small, dense-core, membrane-bound granules. The tumor is often locally aggressive, has the potential to metastasize to lymph nodes, and eventually causes death. The authors report a case of such a neoplasm that affected a 24-year-old man with congenital ectodermal dysplasia. It was associated with a concurrent basal cell carcinoma.


Subject(s)
Adenocarcinoma/pathology , Skin Neoplasms/pathology , Adult , Humans , Male , Nose
SELECTION OF CITATIONS
SEARCH DETAIL