Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Radiographics ; 43(5): e220105, 2023 05.
Article in English | MEDLINE | ID: mdl-37104124

ABSTRACT

To translate artificial intelligence (AI) algorithms into clinical practice requires generalizability of models to real-world data. One of the main obstacles to generalizability is data shift, a data distribution mismatch between model training and real environments. Explainable AI techniques offer tools to detect and mitigate the data shift problem and develop reliable AI for clinical practice. Most medical AI is trained with datasets gathered from limited environments, such as restricted disease populations and center-dependent acquisition conditions. The data shift that commonly exists in the limited training set often causes a significant performance decrease in the deployment environment. To develop a medical application, it is important to detect potential data shift and its impact on clinical translation. During AI training stages, from premodel analysis to in-model and post hoc explanations, explainability can play a key role in detecting model susceptibility to data shift, which is otherwise hidden because the test data have the same biased distribution as the training data. Performance-based model assessments cannot effectively distinguish the model overfitting to training data bias without enriched test sets from external environments. In the absence of such external data, explainability techniques can aid in translating AI to clinical practice as a tool to detect and mitigate potential failures due to data shift. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Subject(s)
Algorithms , Artificial Intelligence , Humans
2.
Minim Invasive Ther Allied Technol ; 31(3): 410-417, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33207973

ABSTRACT

INTRODUCTION: Minimally invasive image-guided interventions have changed the face of procedural medicine. For these procedures, safety and efficacy depend on precise needle placement. Needle targeting devices help improve the accuracy of needle placement, but their use has not seen broad penetration. Some of these devices are costly and require major modifications to the clinical workflow. In this article, we developed a low-cost, disposable, and easy-to-use angulation tracking device, which was based on a redesigned commercial passive needle holder. MATERIAL AND METHODS: The new design provided real-time angulation information for needle tracking. In this design, two potentiometers were used as angulation sensors, and they were connected to two axes of the passive needle holder's arch structure through a 3 D-printed bridge structure. A control unit included an Arduino Pro Mini, a Bluetooth module, and two rechargeable batteries. The angulation was calculated and communicated in real time to a novel developed smartphone app, where real-time angulation information was displayed for guiding the operator to position the needle to the planned angles. RESULTS: The open-air test results showed that the average errors are 1.03° and 1.08° for left-right angulation and head-foot angulation, respectively. The animal cadaver tests revealed that the novel system had an average angular error of 3.2° and a radial distance error of 3.1 mm. CONCLUSIONS: The accuracy was comparable with some commercially available solutions. The novel and low-cost needle tracking device may find a role as part of a real-time precision approach to both planning and implementation of image-guided therapies.


Subject(s)
Needles , Surgical Instruments , Animals , Image-Guided Biopsy/methods , Phantoms, Imaging , Workflow
3.
Radiology ; 297(1): 6-14, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32840473

ABSTRACT

Artificial intelligence (AI) is becoming increasingly present in radiology and health care. This expansion is driven by the principal AI strengths: automation, accuracy, and objectivity. However, as radiology AI matures to become fully integrated into the daily radiology routine, it needs to go beyond replicating static models, toward discovering new knowledge from the data and environments around it. Continuous learning AI presents the next substantial step in this direction and brings a new set of opportunities and challenges. Herein, the authors discuss the main concepts and requirements for implementing continuous AI in radiology and illustrate them with examples from emerging applications.


Subject(s)
Artificial Intelligence , Radiology/trends , Big Data , Humans
4.
Radiology ; 296(2): 348-355, 2020 08.
Article in English | MEDLINE | ID: mdl-32515678

ABSTRACT

Background Microstructural MRI has the potential to improve diagnosis and characterization of prostate cancer (PCa), but validation with histopathology is lacking. Purpose To validate ex vivo diffusion-relaxation correlation spectrum imaging (DR-CSI) in the characterization of microstructural tissue compartments in prostate specimens from men with PCa by using registered whole-mount digital histopathology (WMHP) as the reference standard. Materials and Methods Men with PCa who underwent 3-T MRI and robotic-assisted radical prostatectomy between June 2018 and January 2019 were prospectively studied. After prostatectomy, the fresh whole prostate specimens were imaged in patient-specific three-dimensionally printed molds by using 3-T MRI with DR-CSI and were then sliced to create coregistered WMHP slides. The DR-CSI spectral signal component fractions (fA, fB, fC) were compared with epithelial, stromal, and luminal area fractions (fepithelium, fstroma, flumen) quantified in PCa and benign tissue regions. A linear mixed-effects model assessed the correlations between (fA, fB, fC) and (fepithelium, fstroma, flumen), and the strength of correlations was evaluated by using Spearman correlation coefficients. Differences between PCa and benign tissues in terms of DR-CSI signal components and microscopic tissue compartments were assessed using two-sided t tests. Results Prostate specimens from nine men (mean age, 65 years ± 7 [standard deviation]) were evaluated; 20 regions from 17 PCas, along with 20 benign tissue regions of interest, were analyzed. Three DR-CSI spectral signal components (spectral peaks) were consistently identified. The fA, fB, and fC were correlated with fepithelium, fstroma, and flumen (all P < .001), with Spearman correlation coefficients of 0.74 (95% confidence interval [CI]: 0.62, 0.83), 0.80 (95% CI: 0.66, 0.89), and 0.67 (95% CI: 0.51, 0.81), respectively. PCa exhibited differences compared with benign tissues in terms of increased fA (PCa vs benign, 0.37 ± 0.05 vs 0.27 ± 0.06; P < .001), decreased fC (PCa vs benign, 0.18 ± 0.06 vs 0.31 ± 0.13; P = .01), increased fepithelium (PCa vs benign, 0.44 ± 0.13 vs 0.26 ± 0.16; P < .001), and decreased flumen (PCa vs benign, 0.14 ± 0.08 vs 0.27 ± 0.18; P = .004). Conclusion Diffusion-relaxation correlation spectrum imaging signal components correlate with microscopic tissue compartments in the prostate and differ between cancer and benign tissue. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Lee and Hectors in this issue.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Prostate/diagnostic imaging , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Aged , Histocytochemistry , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Prospective Studies , Reproducibility of Results
5.
J Magn Reson Imaging ; 49(1): 270-279, 2019 01.
Article in English | MEDLINE | ID: mdl-30069968

ABSTRACT

BACKGROUND: Patient-specific 3D-printed molds and ex vivo MRI of the resected prostate have been two important strategies to align MRI with whole-mount histopathology (WMHP) for prostate cancer (PCa) research, but the combination of these two strategies has not been systematically evaluated. PURPOSE: To develop and evaluate a system that combines patient-specific 3D-printed molds with ex vivo MRI (ExV) to spatially align in vivo MRI (InV), ExV, and WMHP in PCa patients. STUDY TYPE: Prospective cohort study. POPULATION: Seventeen PCa patients who underwent 3T MRI and robotic-assisted laparoscopic radical prostatectomy (RALP). FIELD STRENGTH/SEQUENCES: T2 -weighted turbo spin-echo sequences at 3T. ASSESSMENT: Immediately after RALP, the fresh whole prostate specimens were imaged in patient-specific 3D-printed molds by 3T MRI and then sectioned to create WMHP slides. The time required for ExV was measured to assess impact on workflow. InV, ExV, and WMHP images were registered. Spatial alignment was evaluated using: slide offset (mm) between ExV slice locations and WMHP slides; overlap of the 3D prostate contour on InV versus ExV using Dice's coefficient (0 to 1); and 2D target registration error (TRE, mm) between corresponding landmarks on InV, ExV, and WMHP. Data are reported as mean ± standard deviation (SD). STATISTICAL TESTING: Differences in 2D TRE before versus after registration were compared using the Wilcoxon signed-rank test (P < 0.05 considered significant). RESULTS: ExV (duration 115 ± 15 min) was successfully incorporated into the workflow for all cases. Absolute slide offset was 1.58 ± 1.57 mm. Dice's coefficient was 0.865 ± 0.035. 2D TRE was significantly reduced after registration (P < 0.01) with mean (±SD of per patient means) of 1.9 ± 0.6 mm for InV versus ExV, 1.4 ± 0.5 mm for WMHP versus ExV, and 2.0 ± 0.5 mm for WMHP versus InV. DATA CONCLUSION: The proposed system combines patient-specific 3D-printed molds with ExV to achieve spatial alignment between InV, ExV, and WMHP with mean 2D TRE of 1-2 mm. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:270-279.


Subject(s)
Magnetic Resonance Imaging , Printing, Three-Dimensional , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Aged , Equipment Design , Humans , Laparoscopy , Male , Middle Aged , Prospective Studies , Prostatectomy/methods , Reproducibility of Results , Robotic Surgical Procedures , Robotics , Seminal Vesicles/pathology
6.
Radiology ; 282(3): 903-912, 2017 03.
Article in English | MEDLINE | ID: mdl-27755912

ABSTRACT

Purpose To identify the variables and factors that affect the quantity and quality of nucleic acid yields from imaging-guided core needle biopsy. Materials and Methods This study was approved by the institutional review board and compliant with HIPAA. The authors prospectively obtained 232 biopsy specimens from 74 patients (177 ex vivo biopsy samples from surgically resected masses were obtained from 49 patients and 55 in vivo lung biopsy samples from computed tomographic [CT]-guided lung biopsies were obtained from 25 patients) and quantitatively measured DNA and RNA yields with respect to needle gauge, number of needle passes, and percentage of the needle core. RNA quality was also assessed. Significance of correlations among variables was assessed with analysis of variance followed by linear regression. Conditional probabilities were calculated for projected sample yields. Results The total nucleic acid yield increased with an increase in the number of needle passes or a decrease in needle gauge (two-way analysis of variance, P < .0001 for both). However, contrary to calculated differences in volume yields, the effect of needle gauge was markedly greater than the number of passes. For example, the use of an 18-gauge versus a 20-gauge biopsy needle resulted in a 4.8-5.7 times greater yield, whereas a double versus a single pass resulted in a 2.4-2.8 times greater yield for 18- versus 20-gauge needles, respectively. Ninety-eight of 184 samples (53%) had an RNA integrity number of at least 7 (out of a possible score of 10). Conclusion With regard to optimizing nucleic acid yields in CT-guided lung core needle biopsies used for genomic analysis, there should be a preference for using lower gauge needles over higher gauge needles with more passes. ©RSNA, 2016 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 21, 2016.


Subject(s)
Genomics , Lung Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Biopsy, Needle , Female , Humans , Lung/pathology , Male , Middle Aged , Prospective Studies , Young Adult
7.
Eur Radiol ; 27(9): 3647-3651, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28280932

ABSTRACT

Advances in informatics and information technology are sure to alter the practice of medical imaging and image-guided therapies substantially over the next decade. Each element of the imaging continuum will be affected by substantial increases in computing capacity coincident with the seamless integration of digital technology into our society at large. This article focuses primarily on areas where this IT transformation is likely to have a profound effect on the practice of radiology. KEY POINTS: • Clinical decision support ensures consistent and appropriate resource utilization. • Big data enables correlation of health information across multiple domains. • Data mining advances the quality of medical decision-making. • Business analytics allow radiologists to maximize the benefits of imaging resources.


Subject(s)
Radiology Information Systems/trends , Radiology/trends , Clinical Decision-Making/methods , Data Mining/methods , Data Mining/trends , Decision Support Systems, Clinical/trends , Humans , Information Technology/trends , Internet/trends , Medical Informatics/trends
8.
J Digit Imaging ; 35(5): 1358-1361, 2022 10.
Article in English | MEDLINE | ID: mdl-35441279

Subject(s)
Radiology , Humans
9.
J Neurointerv Surg ; 15(3): e7, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35177517

ABSTRACT

Robotic-assisted technology has shown to be promising in coronary and peripheral vascular interventions. Early case reports have also demonstrated its efficacy in neuro-interventions. However, there is no prior report demonstrating use of the robotic-assisted platform for spinal angiography. We report the feasibility of the robotic-assisted thoracic and lumbar spinal angiography.


Subject(s)
Robotic Surgical Procedures , Humans , Treatment Outcome , Angiography
10.
IEEE Trans Biomed Eng ; 70(2): 401-412, 2023 02.
Article in English | MEDLINE | ID: mdl-35853075

ABSTRACT

OBJECTIVE: Gadolinium-based contrast agents (GBCAs) have been widely used to better visualize disease in brain magnetic resonance imaging (MRI). However, gadolinium deposition within the brain and body has raised safety concerns about the use of GBCAs. Therefore, the development of novel approaches that can decrease or even eliminate GBCA exposure while providing similar contrast information would be of significant use clinically. METHODS: In this work, we present a deep learning based approach for contrast-enhanced T1 synthesis on brain tumor patients. A 3D high-resolution fully convolutional network (FCN), which maintains high resolution information through processing and aggregates multi-scale information in parallel, is designed to map pre-contrast MRI sequences to contrast-enhanced MRI sequences. Specifically, three pre-contrast MRI sequences, T1, T2 and apparent diffusion coefficient map (ADC), are utilized as inputs and the post-contrast T1 sequences are utilized as target output. To alleviate the data imbalance problem between normal tissues and the tumor regions, we introduce a local loss to improve the contribution of the tumor regions, which leads to better enhancement results on tumors. RESULTS: Extensive quantitative and visual assessments are performed, with our proposed model achieving a PSNR of 28.24 dB in the brain and 21.2 dB in tumor regions. CONCLUSION AND SIGNIFICANCE: Our results suggest the potential of substituting GBCAs with synthetic contrast images generated via deep learning.


Subject(s)
Brain Neoplasms , Gadolinium , Humans , Magnetic Resonance Imaging/methods , Image Enhancement/methods , Diffusion Magnetic Resonance Imaging , Contrast Media
11.
Acad Radiol ; 30(3): 412-420, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35644754

ABSTRACT

RATIONALE AND OBJECTIVES: To develop artificial intelligence (AI) system that assists in checking endotracheal tube (ETT) placement on chest X-rays (CXRs) and evaluate whether it can move into clinical validation as a quality improvement tool. MATERIALS AND METHODS: A retrospective data set including 2000 de-identified images from intensive care unit patients was split into 1488 for training and 512 for testing. AI was developed to automatically identify the ETT, trachea, and carina using semantically embedded neural networks that combine a declarative knowledge base with deep neural networks. To check the ETT tip placement, a "safe zone" was computed as the region inside the trachea and 3-7 cm above the carina. Two AI outputs were evaluated: (1) ETT overlay, (2) ETT misplacement alert messages. Clinically relevant performance metrics were compared against prespecified thresholds of >85% overlay accuracy and positive predictive value (PPV) > 30% and negative predictive value NPV > 95% for alerts to move into clinical validation. RESULTS: An ETT was present in 285 of 512 test cases. The AI detected 95% (271/285) of ETTs, 233 (86%) of these with accurate tip localization. The system (correctly) did not generate an ETT overlay in 221/227 CXRs where the tube was absent for an overall overlay accuracy of 89% (454/512). The alert messages indicating that either the ETT was misplaced or not detected had a PPV of 83% (265/320) and NPV of 98% (188/192). CONCLUSION: The chest X-ray AI met prespecified performance thresholds to move into clinical validation.


Subject(s)
Artificial Intelligence , Intubation, Intratracheal , Humans , Retrospective Studies , Intubation, Intratracheal/methods , Trachea/diagnostic imaging , Neural Networks, Computer
12.
J Med Imaging (Bellingham) ; 10(5): 051805, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37113505

ABSTRACT

Purpose: To integrate and evaluate an artificial intelligence (AI) system that assists in checking endotracheal tube (ETT) placement on chest x-rays (CXRs) in clinical practice. Approach: In clinical use over 17 months, 214 CXR images were ordered to check ETT placement with AI assistance by intensive care unit (ICU) physicians. The system was built on the SimpleMind Cognitive AI platform and integrated into a clinical workflow. It automatically identified the ETT and checked its placement relative to the trachea and carina. The ETT overlay and misplacement alert messages generated by the AI system were compared with radiology reports as the reference. A survey study was also conducted to evaluate usefulness of the AI system in clinical practice. Results: The alert messages indicating that either the ETT was misplaced or not detected had a positive predictive value of 42% (21/50) and negative predictive value of 98% (161/164) based on the radiology reports. In the survey, radiologist and ICU physician users indicated that they agreed with the AI outputs and that they were useful. Conclusions: The AI system performance in real-world clinical use was comparable to that seen in previous experiments. Based on this and physician survey results, the system can be deployed more widely at our institution, using insights gained from this evaluation to make further algorithm improvements and quality assurance of the AI system.

13.
Radiology ; 263(1): 243-52, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22438447

ABSTRACT

A diagnostic radiology value chain is constructed to define its main components, all of which are vulnerable to change, because digitization has caused disaggregation of the chain. Some components afford opportunities to improve productivity, some add value, while some face outsourcing to lower labor cost and to information technology substitutes, raising commoditization risks. Digital image information, because it can be competitive at smaller economies of scale, allows faster, differential rates of technological innovation of components, initiating a centralization-to-decentralization technology trend. Digitization, having triggered disaggregation of radiology's professional service model, may soon usher in an information business model. This means moving from a mind-set of "reading images" to an orientation of creating and organizing information for greater accuracy, faster speed, and lower cost in medical decision making. Information businesses view value chain investments differently than do small professional services. In the former model, producing a better business product will extend image interpretation beyond a radiologist's personal fund of knowledge to encompass expanding external imaging databases. A follow-on expansion with integration of image and molecular information into a report will offer new value in medical decision making. Improved interpretation plus new integration will enrich and diversify radiology's key service products, the report and consultation. A more robust, information-rich report derived from a "systems" and "computational" radiology approach will be facilitated by a transition from a professional service to an information business. Under health care reform, radiology will transition its emphasis from volume to greater value. Radiology's future brightens with the adoption of a philosophy of offering information rather than "reads" for decision making. Staunchly defending the status quo via turf wars is unlikely to constitute a forward-looking, competitive strategy.


Subject(s)
Models, Organizational , Practice Management, Medical/organization & administration , Radiology/economics , Radiology/trends , Decision Making , Efficiency, Organizational , Forecasting , Health Care Reform , Humans , Organizational Culture , Organizational Innovation , Organizational Objectives
14.
Rofo ; 194(1): 21-28, 2022 01.
Article in English | MEDLINE | ID: mdl-34139780

ABSTRACT

The future of IR will evolve as a result of current trends in advances in medicine, disease biology, technology, and IR devices and accoutrements. Changes in the trends that lie at the center of the differentiation of IR from other treatment specialties will have the greatest impact. Differentiation revolves around image guidance knowledge and procedural treatment skills and involves three key components: access, mapping, and action, all of which have the common thread of imaging knowledge. The main trends that are discussed are: image-guided diagnostics (IgDx), image-guided treatment (IgRx), sub-specialization in IgRx, large device design for IgRx, multimodality IgRx, interdisciplinary IgRx, and decentralized IgRx growth. Success in attaining a patient-facing "front-line" patient position will determine the future not only of IR but of radiology as a field. IgRx is anti-commoditization immunization. KEY POINTS:: · It is useful to conceptually separate diagnostic (IgDx) and treatment (IgRx) IR procedures.. · Subspecialization in IgRx will innovate IR practices for all practitioners.. · Advances in IR-tailored imaging equipment and integration of multimodality imaging will create, expand, and facilitate new treatments.. · Other treatment disciplines will be integrated into IgRx in a complementary fashion.. · Expansion of IR services into outpatient imaging sites and outpatient clinics will help establish important direct patient care.. · The adoption of these trends will follow a "diffusion of innovations" sigmoid curve pattern spanning different time intervals.. CITATION FORMAT: · Enzmann D. Trends that Impact IR's Future. Fortschr Röntgenstr 2022; 194: 21 - 28.


Subject(s)
Radiology , Diagnostic Imaging , Humans
15.
JCO Clin Cancer Inform ; 6: e2100142, 2022 01.
Article in English | MEDLINE | ID: mdl-35025671

ABSTRACT

PURPOSE: Multidisciplinary oncology meetings, or tumor boards (TBs), ensure and facilitate communication between specialties regarding the management of cancer cases to improve patient care. The organization of TB and the preparation and presentation of patient cases are typically inefficient processes that require the exchange of patient information via e-mail, the hunting for data and images in the electronic health record, and the copying and pasting of patient data into desktop presentation software. METHODS: We implemented a standards-based electronic health record-integrated application that automated several aspects of TB organization and preparation. We hypothesized that this application would increase the efficiency of TB preparation, reduce errors in patient entry, and enhance communication with the clinical team. Our experimental design used a prospective evaluation by pathologists who were timed in preparing for weekly TBs using both the new application and the conventional method. In addition, patient data entry errors associated with each method were tracked, and TB attendees completed a survey evaluating satisfaction with the new application. RESULTS: The total time savings for TB preparation using the digital TB application over the conventional method was 5 hours and 19 minutes, representing a 45% reduction in preparation time (P < .01). Survey results showed that 91% of respondents preferred the digital method and believed that it improved the flow of the TB meeting. In addition, most believed that the digital method had an impact on subsequent patient care. CONCLUSION: This study provides further evidence that new electronic systems have the potential to significantly improve the overall TB paradigm by optimizing and enhancing case organization, preparation, and presentation.


Subject(s)
Electronic Health Records , Neoplasms , Communication , Humans , Medical Oncology , Neoplasms/therapy
16.
BMJ Case Rep ; 14(3): 1-3, 2021 Mar 10.
Article in English | MEDLINE | ID: mdl-33692074

ABSTRACT

Robotic-assisted technology has shown to be promising in coronary and peripheral vascular interventions. Early case reports have also demonstrated its efficacy in neuro-interventions. However, there is no prior report demonstrating use of the robotic-assisted platform for spinal angiography. We report the feasibility of the robotic-assisted thoracic and lumbar spinal angiography.


Subject(s)
Robotic Surgical Procedures , Robotics , Coronary Angiography , Humans , Spine , Treatment Outcome
17.
J Am Med Inform Assoc ; 28(6): 1259-1264, 2021 06 12.
Article in English | MEDLINE | ID: mdl-33537772

ABSTRACT

OBJECTIVE: To demonstrate enabling multi-institutional training without centralizing or sharing the underlying physical data via federated learning (FL). MATERIALS AND METHODS: Deep learning models were trained at each participating institution using local clinical data, and an additional model was trained using FL across all of the institutions. RESULTS: We found that the FL model exhibited superior performance and generalizability to the models trained at single institutions, with an overall performance level that was significantly better than that of any of the institutional models alone when evaluated on held-out test sets from each institution and an outside challenge dataset. DISCUSSION: The power of FL was successfully demonstrated across 3 academic institutions while avoiding the privacy risk associated with the transfer and pooling of patient data. CONCLUSION: Federated learning is an effective methodology that merits further study to enable accelerated development of models across institutions, enabling greater generalizability in clinical use.


Subject(s)
Deep Learning , Information Dissemination , Humans , Privacy
18.
Cereb Cortex ; 19(11): 2746-54, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19321653

ABSTRACT

The human visual pathways that are specialized for object recognition stretch from lateral occipital cortex (LO) to the ventral surface of the temporal lobe, including the fusiform gyrus. Plasticity in these pathways supports the acquisition of visual expertise, but precisely how training affects the different regions remains unclear. We used functional magnetic resonance imaging to measure neural activity in both LO and the fusiform gyrus in radiologists as they detected abnormalities in chest radiographs. Activity in the right fusiform face area (FFA) correlated with visual expertise, measured as behavioral performance during scanning. In contrast, activity in left LO correlated negatively with expertise, and the amount of LO that responded to radiographs was smaller in experts than in novices. Activity in the FFA and LO correlated negatively in experts, whereas in novices, the 2 regions showed no stable relationship. Together, these results suggest that the FFA becomes more engaged and left LO less engaged in interpreting radiographic images over the course of training. Achieving expert visual performance may involve suppressing existing neural representations while simultaneously developing others.


Subject(s)
Neural Inhibition/physiology , Occipital Lobe/physiology , Pattern Recognition, Visual/physiology , Physicians , Professional Competence , Radiology , Visual Cortex/physiology , Female , Humans , Male , Middle Aged
19.
J Am Coll Radiol ; 17(10): 1299-1306, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32387372

ABSTRACT

Diagnostic radiology (DxR), having had successful serial co-evolutions with imaging equipment and PACS, is faced with another. With a backdrop termed "globotics transition," it should create an IT and informatics infrastructure capable of integrating artificial intelligence (AI) into current critical communication functions of PACS and incorporating functions currently residing in balkanized products. DxR will face the challenge of adopting sustaining and disruptive AI innovations simultaneously. In this co-evolution, a major selection force for AI will be increasing the flow of information and patients; "increasing" means faster flow over larger areas defined by geography and content. Larger content includes a broader spectrum of imaging and nonimaging information streams that facilitate medical decision making. Evolution to faster flow will gravitate toward a hierarchical IT architecture consisting of many small channels feeding into fewer larger channels, something potentially difficult for current PACS. Smartphone-like architecture optimized for communication and integration could provide a large-channel backbone and many smaller feeding channels for basic functions, as well as those needing to innovate rapidly. New, more flexible architectures stimulate market competition in which DxR could act as an artificial selection force to influence development of faster increased flow in current PACS companies, in disruptors such as consolidated AI companies, or in entirely new entrants like Apple or Google. In this co-evolution, DxR should be able to stimulate design of a modern communication medium that increases the flow of information and decreases the time and energy necessary to absorb it, thereby creating even more indispensable clinical value for itself.


Subject(s)
Radiology Information Systems , Radiology , Artificial Intelligence , Diagnostic Imaging , Humans , Smartphone
20.
J Am Coll Radiol ; 17(9): 1086-1095, 2020 09.
Article in English | MEDLINE | ID: mdl-32717183

ABSTRACT

OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic resulted in significant loss of radiologic volume as a result of shelter-at-home mandates and delay of non-time-sensitive imaging studies to preserve capacity for the pandemic. We analyze the volume-related impact of the COVID-19 pandemic on six academic medical systems (AMSs), three in high COVID-19 surge (high-surge) and three in low COVID-19 surge (low-surge) regions, and a large national private practice coalition. We sought to assess adaptations, risks of actions, and lessons learned. METHODS: Percent change of 2020 volume per week was compared with the corresponding 2019 volume calculated for each of the 14 imaging modalities and overall total, outpatient, emergency, and inpatient studies in high-surge AMSs and low-surge AMSs and the practice coalition. RESULTS: Steep examination volume drops occurred during week 11, with slow recovery starting week 17. The lowest total AMS volume drop was 40% compared with the same period the previous year, and the largest was 70%. The greatest decreases were seen with screening mammography and dual-energy x-ray absorptiometry scans, and the smallest decreases were seen with PET/CT, x-ray, and interventional radiology. Inpatient volume was least impacted compared with outpatient or emergency imaging. CONCLUSION: Large percentage drops in volume were seen from weeks 11 through 17, were seen with screening studies, and were larger for the high-surge AMSs than for the low-surge AMSs. The lowest drops in volume were seen with modalities in which delays in imaging had greater perceived adverse consequences.


Subject(s)
Coronavirus Infections/prevention & control , Diagnostic Imaging/statistics & numerical data , Infection Control/organization & administration , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Positron Emission Tomography Computed Tomography/statistics & numerical data , Radiology/statistics & numerical data , COVID-19 , Coronavirus Infections/epidemiology , Diagnostic Imaging/methods , Female , Forecasting , Humans , Incidence , Learning , Male , Pandemics/statistics & numerical data , Pneumonia, Viral/epidemiology , Radiology/trends , Risk Assessment , United States
SELECTION OF CITATIONS
SEARCH DETAIL