Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 740
Filter
Add more filters

Publication year range
1.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38588025

ABSTRACT

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Kaplan-Meier Estimate , Stroke/epidemiology , Stroke/etiology , Stroke/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality , Risk Factors , Germany
2.
N Engl J Med ; 386(4): 327-339, 2022 01 27.
Article in English | MEDLINE | ID: mdl-34767705

ABSTRACT

BACKGROUND: Tricuspid regurgitation is common in patients with severe degenerative mitral regurgitation. However, the evidence base is insufficient to inform a decision about whether to perform tricuspid-valve repair during mitral-valve surgery in patients who have moderate tricuspid regurgitation or less-than-moderate regurgitation with annular dilatation. METHODS: We randomly assigned 401 patients who were undergoing mitral-valve surgery for degenerative mitral regurgitation to receive a procedure with or without tricuspid annuloplasty (TA). The primary 2-year end point was a composite of reoperation for tricuspid regurgitation, progression of tricuspid regurgitation by two grades from baseline or the presence of severe tricuspid regurgitation, or death. RESULTS: Patients who underwent mitral-valve surgery plus TA had fewer primary-end-point events than those who underwent mitral-valve surgery alone (3.9% vs. 10.2%) (relative risk, 0.37; 95% confidence interval [CI], 0.16 to 0.86; P = 0.02). Two-year mortality was 3.2% in the surgery-plus-TA group and 4.5% in the surgery-alone group (relative risk, 0.69; 95% CI, 0.25 to 1.88). The 2-year prevalence of progression of tricuspid regurgitation was lower in the surgery-plus-TA group than in the surgery-alone group (0.6% vs. 6.1%; relative risk, 0.09; 95% CI, 0.01 to 0.69). The frequencies of major adverse cardiac and cerebrovascular events, functional status, and quality of life were similar in the two groups at 2 years, although the incidence of permanent pacemaker implantation was higher in the surgery-plus-TA group than in the surgery-alone group (14.1% vs. 2.5%; rate ratio, 5.75; 95% CI, 2.27 to 14.60). CONCLUSIONS: Among patients undergoing mitral-valve surgery, those who also received TA had a lower incidence of a primary-end-point event than those who underwent mitral-valve surgery alone at 2 years, a reduction that was driven by less frequent progression to severe tricuspid regurgitation. Tricuspid repair resulted in more frequent permanent pacemaker implantation. Whether reduced progression of tricuspid regurgitation results in long-term clinical benefit can be determined only with longer follow-up. (Funded by the National Heart, Lung, and Blood Institute and the German Center for Cardiovascular Research; ClinicalTrials.gov number, NCT02675244.).


Subject(s)
Cardiac Valve Annuloplasty , Disease Progression , Mitral Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Aged , Dilatation, Pathologic , Female , Follow-Up Studies , Humans , Intention to Treat Analysis , Male , Mitral Valve/surgery , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/mortality , Pacemaker, Artificial , Postoperative Complications , Quality of Life , Reoperation , Survival Analysis , Tricuspid Valve/pathology , Tricuspid Valve Insufficiency/complications , Tricuspid Valve Insufficiency/therapy
3.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38833618

ABSTRACT

AIMS: Debulking of infective mass to reduce the burden if infective material is a fundamental principle in the surgical management of infection. The aim of this study was to investigate the validity of this principle in patients undergoing transvenous lead extraction in the context of bloodstream infection (BSI). METHODS AND RESULTS: We performed an observational single-centre study on patients that underwent transvenous lead extraction due to a BSI, with or without lead-associated vegetations, in combination with a percutaneous aspiration system during the study period 2015-22. One hundred thirty-seven patients were included in the final analysis. In patients with an active BSI at the time of intervention, the use of a percutaneous aspiration system had a significant impact on survival (log-rank: P = 0.0082), while for patients with a suppressed BSI at the time of intervention, the use of a percutaneous aspiration system had no significant impact on survival (log-rank: P = 0.25). CONCLUSION: A reduction of the infective burden by percutaneous debulking of lead vegetations might improve survival in patients with an active BSI.


Subject(s)
Device Removal , Prosthesis-Related Infections , Humans , Female , Male , Device Removal/methods , Aged , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/mortality , Middle Aged , Treatment Outcome , Defibrillators, Implantable/adverse effects , Suction , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial/microbiology , Endocarditis, Bacterial/surgery , Endocarditis, Bacterial/microbiology , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/mortality , Endocarditis, Bacterial/etiology , Retrospective Studies , Time Factors , Risk Factors , Aged, 80 and over
4.
Artif Organs ; 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38651352

ABSTRACT

BACKGROUND: In vitro assessment is mandatory for artificial heart valve development. This study aims to investigate the effects of pulse duplicator features on valve responsiveness, conduct a sensitivity analysis across valve prosthesis types, and contribute on the development of versatile pulse duplicator systems able to perform reliable prosthetic aortic valve assessment under physiologic hemodynamic conditions. METHODS: A reference pulse duplicator was established based on literature. Further optimization process led to new designs that underwent a parametric study, also involving different aortic valve prostheses. These designs were evaluated on criteria such as mean pressure differential and pulse pressure (assessed from high-fidelity pressure measurements), valve opening and closing behavior, flow, and regurgitation. Finally, the resulting optimized setup was tested under five different hemodynamic settings simulating a range of physiologic and pathologic conditions. RESULTS: The results show that both, pulse duplicator design and valve type significantly influence aortic and ventricular pressure, flow, and valve kinematic response. The optimal design comprised key features such as a compliance chamber and restrictor for diastolic pressure maintenance and narrow pulse pressure. Additionally, an atrial reservoir was included to prevent atrial-aortic interference, and a bioprosthetic valve was used in mitral position to avoid delayed valve closing effects. CONCLUSION: This study showed that individual pulse duplicator features can have a significant effect on valve's responsiveness. The optimized versatile pulse duplicator replicated physiologic and pathologic aortic valve hemodynamic conditions, serving as a reliable characterization tool for assessing and optimizing aortic valve performance.

5.
Artif Organs ; 48(1): 83-90, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37723833

ABSTRACT

BACKGROUND: Driveline infections (DLI) are a serious complication in patients with left ventricular assist devices (LVAD). Apart from the differentiation between superficial and deep DLI, there is no consensus on the classification of the severity of DLI. Little is known about risk factors and typical bacteria causing DLI in centrifugal-flow LVADs. METHODS: In this single-center study with 245 patients, DLI were classified by their local appearance using a modification of a score suggested by the Sharp Memorial group. The driveline exit site was inspected routinely every 6 months. RESULTS: Severe DLI were detected in 34 patients (15%) after 6 months and in 24 patients (22%) after 24 months. The proportion of patients with DLI increased significantly during the follow-up (p = 0.0096). The most common bacteria in local smears were Corynebacterium, coagulase-negative Staphylococcus, and Staphylococcus aureus. Fifty-nine patients were hospitalized more than once for DLI. In these patients, S. aureus was the most common bacterium. It was also the most common bacterium in blood cultures. Higher BMI, no partnership, and a HeartMate 3 device were identified as risk factors for DLI in a multivariable cause-specific Cox regression. CONCLUSION: This study is a standardized analysis of DLI in a large cohort with centrifugal-flow LVADs.


Subject(s)
Heart Failure , Heart-Assist Devices , Prosthesis-Related Infections , Humans , Incidence , Heart-Assist Devices/adverse effects , Staphylococcus aureus , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Retrospective Studies , Heart Failure/etiology
6.
J Cardiothorac Vasc Anesth ; 38(5): 1150-1160, 2024 May.
Article in English | MEDLINE | ID: mdl-38378323

ABSTRACT

OBJECTIVE: Acute kidney injury (AKI) requiring renal-replacement therapy (RRT) after heart transplantation (OHT) is common and impairs outcomes. This study aimed to identify independent donor and recipient risk factors associated with RRT after OHT. DESIGN: A retrospective data analysis. SETTING: Data were collected from clinical routines in a maximum-care university hospital. PARTICIPANTS: Patients who underwent OHT. INTERVENTIONS: The authors retrospectively analyzed data from 264 patients who underwent OHT between 2012 and 2021; 189 patients were eligible and included in the final analysis. MEASUREMENTS AND MAIN RESULTS: The mean age was 48.0 ± 12.3 years, and 71.4% of patients were male. Ninety (47.6%) patients were on long-term mechanical circulatory support (lt-MCS). Posttransplant AKI with RRT occurred in 123 (65.1%) patients. In a multivariate analysis, preoperative body mass index >25 kg/m² (odds ratio [OR] 4.74, p < 0.001), elevated preoperative creatinine levels (OR for each mg/dL increase 3.44, p = 0.004), administration of red blood cell units during transplantation procedure (OR 2.31, p = 0.041) and ischemia time (OR for each hour increase 1.77, p = 0.004) were associated with a higher incidence of RRT. The use of renin-angiotensin-aldosterone system blockers before transplantation was associated with a reduced risk of RRT (OR 0.36, p = 0.013). The risk of mortality was 6.9-fold higher in patients who required RRT (hazard ratio 6.9, 95% CI: 2.1-22.6 p = 0.001). Previous lt-MCS, as well as donor parameters, were not associated with RRT after OHT. CONCLUSIONS: The implementation of guideline-directed medical therapy, weight reduction, minimizing ischemia time (ie, organ perfusion systems, workflow optimization), and comprehensive patient blood management potentially influences renal function and outcomes after OHT.


Subject(s)
Acute Kidney Injury , Heart Transplantation , Humans , Male , Adult , Middle Aged , Female , Retrospective Studies , Acute Kidney Injury/epidemiology , Acute Kidney Injury/etiology , Acute Kidney Injury/therapy , Risk Factors , Renal Replacement Therapy , Heart Transplantation/adverse effects , Ischemia/etiology
7.
Eur Heart J ; 44(41): 4310-4320, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37632756

ABSTRACT

In October 2021, the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) jointly agreed to establish a Task Force (TF) to review recommendations of the 2018 ESC/EACTS Guidelines on myocardial revascularization as they apply to patients with left main (LM) disease with low-to-intermediate SYNTAX score (0-32). This followed the withdrawal of support by the EACTS in 2019 for the recommendations about the management of LM disease of the previous guideline. The TF was asked to review all new relevant data since the 2018 guidelines including updated aggregated data from the four randomized trials comparing percutaneous coronary intervention (PCI) with drug-eluting stents vs. coronary artery bypass grafting (CABG) in patients with LM disease. This document represents a summary of the work of the TF; suggested updated recommendations for the choice of revascularization modality in patients undergoing myocardial revascularization for LM disease are included. In stable patients with an indication for revascularization for LM disease, with coronary anatomy suitable for both procedures and a low predicted surgical mortality, the TF concludes that both treatment options are clinically reasonable based on patient preference, available expertise, and local operator volumes. The suggested recommendations for revascularization with CABG are Class I, Level of Evidence A. The recommendations for PCI are Class IIa, Level of Evidence A. The TF recognized several important gaps in knowledge related to revascularization in patients with LM disease and recognizes that aggregated data from the four randomized trials were still only large enough to exclude large differences in mortality.


Subject(s)
Cardiology , Coronary Artery Disease , Percutaneous Coronary Intervention , Thoracic Surgery , Humans , Coronary Artery Disease/surgery , Percutaneous Coronary Intervention/methods , Coronary Artery Bypass/methods , Treatment Outcome
8.
Clin Infect Dis ; 76(6): 1050-1058, 2023 03 21.
Article in English | MEDLINE | ID: mdl-36318608

ABSTRACT

BACKGROUND: The microbial etiology of prosthetic valve infective endocarditis (PVE) can be difficult to identify. Our aim was to investigate the benefit of molecular imaging technique fluorescence in situ hybridization (FISH) combined with 16S rRNA-gene polymerase chain reaction (PCR) and sequencing (FISHseq) for the analysis of infected prosthetic heart valves. METHODS: We retrospectively evaluated the diagnostic outcome of 113 prosthetic valves from 105 patients with suspected PVE, treated in 2003-2013 in the Department of Cardiac Surgery, Charité University Medicine Berlin. Each prosthetic valve underwent cultural diagnostics and was routinely examined by FISH combined with 16S rRNA gene PCR and sequencing. We compared classical microbiological culture outcomes (blood and valve cultures) with FISHseq results and evaluated the diagnostic impact of the molecular imaging technique. RESULTS: Conventional microbiological diagnostic alone turned out to be insufficient, as 67% of preoperative blood cultures were noninformative (negative, inconclusive, or not obtained) and 67% of valve cultures remained negative. FISHseq improved the conventional cultural diagnostic methods in PVE in 30% of the cases and increased diagnostic accuracy. Of the valve culture-negative PVE cases, FISHseq succeeded in identifying the causative pathogen in 35%. CONCLUSIONS: FISHseq improves PVE diagnostics, complementing conventional cultural methods. In addition to species identification, FISH provides information about the severity of PVE and state of the pathogens (eg, stage of biofilm formation, activity, and localization on and within the prosthetic material). As a molecular imaging technique, FISHseq enables the unambiguous discrimination of skin flora as contaminant or infectious agent.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis , Prosthesis-Related Infections , Humans , Endocarditis, Bacterial/microbiology , Heart Valve Prosthesis/adverse effects , Retrospective Studies , In Situ Hybridization, Fluorescence , RNA, Ribosomal, 16S/genetics , Prosthesis-Related Infections/microbiology , Endocarditis/etiology , Molecular Imaging
9.
Am J Physiol Heart Circ Physiol ; 325(4): H729-H738, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37594484

ABSTRACT

Atrial contractility and functional reserve in atrial remodeling (AR) without (AR/-AF) or with atrial fibrillation (AR/+AF) are not well characterized. In this study, functional measurements were performed in right atrial muscle strips (n = 71) obtained from patients (N = 22) undergoing routine cardiac surgery with either no AR [left atrial (LA) diameter < 40 mm and no history of AF (hAF)], AR/-AF (LA diameter ≥ 40 mm, no hAF), or AR/+AF (hAF and LA diameter ≥ 40 mm or LAEF < 45%). AR/-AF and AR/+AF were associated with a prolongation of half-time-to-peak (HTTP, P < 0.001) and time-to-peak (TTP) contraction (P < 0.01) when compared with no AR. This effect was seen at baseline and during ß-adrenergic stimulation with isoproterenol (Iso). Early relaxation assessed by half-relaxation time (HRT) was prolonged in AR/-AF (P = 0.03) but not in AR/+AF when compared with no AR at baseline, but this delay in relaxation in AR/-AF was attenuated with Iso. Late relaxation (τ) did not differ between AR/-AF and no AR but was consistently shorter in AR/+AF than no AR before (P = 0.04) and during Iso (P = 0.01), indicating accelerated late relaxation in AR/+AF. Relative force increase during Iso was higher (P = 0.01) and more dispersed (P = 0.047) in patients with AR/+AF. Relative adrenergic response was unaltered in the myocardium of patients with AR/-AF and AR/+AF. In conclusion, AR/-AF and AR/+AF are associated with changes in myocardial inotropic reserve and contractility. The changes are particularly pronounced in patients with AR/+AF, suggesting that the progression from AR/-AF to AR/+AF is associated with progressive alterations in atrial function that may contribute to arrhythmogenesis.NEW & NOTEWORTHY Mechanical alterations in atrial remodeling without (AR/-AF) and with atrial fibrillation (AR/+AF) have not been studied in detail in human atrial tissue preparations. To our knowledge, this is the first study to compare the mechanical phenotype and inotropic reserve in human atrial myocardial preparations from patients with no atrial remodeling, AR/-AF, and AR/+AF. We identify specific patterns of contractile dysfunction and heterogeneity for both, AR/-AF and AR/+AF, indicating the progression of atrial disease.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Humans , Heart Atria , Isoproterenol/pharmacology , Myocardium , Adrenergic Agents , Phenotype
10.
Europace ; 25(2): 578-585, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36477494

ABSTRACT

AIMS: In patients with infections of cardiac implantable electronic devices (CIEDs), the identification of causative pathogens is complicated by biofilm formations and previous antibiotic therapy. In this work, the impact of an additional fluorescence in situ hybridization (FISH), in combination with polymerase chain reaction and sequencing (FISHseq) was investigated. METHODS AND RESULTS: In 36 patients with CIED infections, FISHseq of explanted devices was performed and compared with standard microbiological cultivation of preoperative and intraoperative samples. The mean age was 61.9 (±16.2) years; 25 (69.4%) were males. Most patients (62.9%) had heart failure with reduced ejection fraction. Infections occurred as endoplastits (n = 26), isolated local generator pocket infection (n = 8), or both (n = 2); CIED included cardiac resynchronization therapy defibrillator (n = 17), implantable cardioverter defibrillator (n = 11), and pacemaker (n = 8) devices. The overall positive FISHseq detection rate was 97%. Intraoperatively, pathogens were isolated in 42 vs. 53% in standard cultivation vs. FISHseq, respectively. In 16 of 17 FISHseq-negative patients, the nucleic acid strain DAPI (4',6-diamidino-2-phenylindole) indicated inactive microorganisms, which were partially organized in biofilms (n = 4) or microcolonies (n = 2). In 13 patients in whom no pathogen was identified preoperatively, standard cultivation and FISHseq identified pathogens in 3 (23%) vs. 8 (62%), respectively. For the confirmation of preoperatively known bacteria, a combined approach was most efficient. CONCLUSION: Fluorescence in situ hybridization sequencing is a valuable tool to detect causative microorganisms in CIED infections. The combination of FISHseq with preoperative cultivation showed the highest efficacy in detecting pathogens. Additional cultivation of intraoperative tissue samples or swabs yielded more confirmation of pathogens known from preoperative culture.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Male , Female , Humans , In Situ Hybridization, Fluorescence , Anti-Bacterial Agents/therapeutic use , Polymerase Chain Reaction , Prosthesis-Related Infections/diagnosis
11.
Europace ; 26(1)2023 Dec 28.
Article in English | MEDLINE | ID: mdl-38193546

ABSTRACT

AIMS: Ongoing clinical trials investigate the therapeutic value of stereotactic cardiac radioablation (cRA) in heart failure patients with ventricular tachycardia. Animal data indicate an effect on local cardiac conduction properties. However, the exact mechanism of cRA in patients remains elusive. Aim of the current study was to investigate in vivo and in vitro myocardial properties in heart failure and ventricular tachycardia upon cRA. METHODS AND RESULTS: High-density 3D electroanatomic mapping in sinus rhythm was performed in a patient with a left ventricular assist device and repeated ventricular tachycardia episodes upon several catheter-based endocardial radio-frequency ablation attempts. Subsequent to electroanatomic mapping and cRA of the left ventricular septum, two additional high-density electroanatomic maps were obtained at 2- and 4-month post-cRA. Myocardial tissue samples were collected from the left ventricular septum during 4-month post-cRA from the irradiated and borderzone regions. In addition, we performed molecular biology and mitochondrial density measurements of tissue and isolated cardiomyocytes. Local voltage was altered in the irradiated region of the left ventricular septum during follow-up. No change of local voltage was observed in the control (i.e. borderzone) region upon irradiation. Interestingly, local activation time was significantly shortened upon irradiation (2-month post-cRA), a process that was reversible (4-month post-cRA). Molecular biology unveiled an increased expression of voltage-dependent sodium channels in the irradiated region as compared with the borderzone, while Connexin43 and transforming growth factor beta were unchanged (4-month post-cRA). Moreover, mitochondrial density was decreased in the irradiated region as compared with the borderzone. CONCLUSION: Our study supports the notion of transiently altered cardiac conduction potentially related to structural and functional cellular changes as an underlying mechanism of cRA in patients with ventricular tachycardia.


Subject(s)
Catheter Ablation , Heart Failure , Tachycardia, Ventricular , Humans , Myocytes, Cardiac , Electrophysiologic Techniques, Cardiac/methods , Heart Ventricles , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Arrhythmias, Cardiac , Catheter Ablation/methods
12.
Eur Heart J ; 43(29): 2729-2750, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35466382

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has matured into a standard treatment option for patients with severe symptomatic aortic valve stenosis (AS) across the whole spectrum of risk. The advances in the interventional treatment of AS raise the question of which patients with severe AS should be referred to surgery. The myriad of clinical permutations does not allow providing a single, uniform treatment strategy. Rather, the advent of TAVI along with established surgical aortic valve replacement (SAVR) fundamentally enforces the role of the multidisciplinary heart team for decision-making recommending the best individual choice of the two options based on a thorough review of clinical and anatomical factors as well as lifetime management considerations. Involvement of the informed patient expressing treatment preferences is a key for a shared decision-making process. Herein, we provide an in-depth review of evidence informing the decision-making process between TAVI and SAVR and key elements for treatment selection. Special attention is given to the populations that have been excluded from randomized clinical trials, and also lifetime management strategies of patients with severe AS are proposed.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Surg Technol Int ; 432023 12 29.
Article in English | MEDLINE | ID: mdl-38237112

ABSTRACT

Recently, temporary mechanical circulatory support (tMCS) has been increasingly used for cardiogenic shock therapy. Originally designed as a bail-out option for patients who could not be weaned from cardiopulmonary bypass, the indications for tMCS have been expended and now enable us to support a wide range of patients with various cardiac pathologies. Modern tMCS devices include microaxial flow pumps (mAFP) which are small, versatile systems that can provide both acute cardiac support and cardiac protection for high-risk interventions. In this paper, we review different surgical implantation techniques with modern mAFP as well as specific aspects of preoperative indications and patient evaluation.

14.
Am Heart J ; 254: 1-11, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35940247

ABSTRACT

The PSY-HEART-I trial indicated that a brief expectation-focused intervention prior to heart surgery improves disability and quality of life 6 months after coronary artery bypass graft surgery (CABG). However, to investigate the clinical utility of such an intervention, a large multi-center trial is needed to generalize the results and their implications for the health care system. The PSY-HEART-II study aims to examine whether a preoperative psychological intervention targeting patients' expectations (EXPECT) can improve outcomes 6 months after CABG (with or without heart valve replacement). EXPECT will be compared to Standard of Care (SOC) and an intervention providing emotional support without targeting expectations (SUPPORT). In a 3-arm multi-center randomized, controlled, prospective trial (RCT), N = 567 patients scheduled for CABG surgery will be randomized to either SOC alone or SOC and EXPECT or SOC and SUPPORT. Patients will be randomized with a fixed unbalanced ratio of 3:3:1 (EXPECT: SUPPORT: SOC) to compare EXPECT to SOC and EXPECT to SUPPORT. Both psychological interventions consist of 2 in-person sessions (à 50 minute), 2 phone consultations (à 20 minute) during the week prior to surgery, and 1 booster phone consultation post-surgery 6 weeks later. Assessment will occur at baseline approx. 3-10 days before surgery, preoperatively the day before surgery, 4-6 days later, and 6 months after surgery. The study's primary end point will be patients' illness-related disability 6 months after surgery. Secondary outcomes will be patients' expectations, subjective illness beliefs, quality of life, length of hospital stay and blood sample parameters (eg, inflammatory parameters such as IL-6, IL-8, CRP). This large multi-center trial has the potential to corroborate and generalize the promising results of the PSY-HEART-I trial for routine care of cardiac surgery patients, and to stimulate revisions of treatment guidelines in heart surgery.


Subject(s)
Cardiac Surgical Procedures , Quality of Life , Humans , Prospective Studies , Coronary Artery Bypass/methods , Preoperative Care/methods , Treatment Outcome , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
15.
Eur Biophys J ; 51(2): 171-184, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34477935

ABSTRACT

The primary aim of this article is to review the clinical challenges related to the supply of power in implanted left ventricular assist devices (LVADs) by means of transcutaneous drivelines. In effect of that, we present the preventive measures and post-operative protocols that are regularly employed to address the leading problem of driveline infections. Due to the lack of reliable wireless solutions for power transfer in LVADs, the development of new driveline configurations remains at the forefront of different strategies that aim to power LVADs in a less destructive manner. To this end, skin damage and breach formation around transcutaneous LVAD drivelines represent key challenges before improving the current standard of care. For this reason, we assess recent strategies on the surface functionalization of LVAD drivelines, which aim to limit the incidence of driveline infection by directing the responses of the skin tissue. Moreover, we propose a class of power transfer systems that could leverage the ability of skin tissue to effectively heal short diameter wounds. In this direction, we employed a novel method to generate thin conductive wires of controllable surface topography with the potential to minimize skin disruption and eliminate the problem of driveline infections. Our initial results suggest the viability of the small diameter wires for the investigation of new power transfer systems for LVADs. Overall, this review uniquely compiles a diverse number of topics with the aim to instigate new research ventures on the design of power transfer systems for IMDs, and specifically LVADs.


Subject(s)
Heart-Assist Devices
16.
Artif Organs ; 46(8): 1573-1584, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35230721

ABSTRACT

BACKGROUND: Despite numerous design iterations, thrombus formation at the inflow cannula of continuous-flow left ventricular assist devices remains an unsolved problem. We systematically investigated the impact of cannula surface on thrombus formation. METHODS: Thrombus appearance was photographically documented in 177 explanted hearts with the polished (N = 46) or sintered (N = 131) inflow cannula of the Medtronic HeartWare™ HVAD™ System. Thrombus load was compared for both inflow cannula types. Mean thrombus length was correlated with protruding cannula length. Support duration and the extent of thrombus growth were examined. The prevalence of thrombi at the left ventricular entry site and at the sintered-to-polished transition zone was correlated with left ventricular geometry and hemodynamic parameters. RESULTS: Polished inflow cannulas showed a greater percentage and also a greater mean length of thrombus formation at the entry site than sintered cannulas (91.3% [Pol] vs. 36.7% [sTi]; p < 0.0001; mean 7.6 mm vs. 1.9 mm; p < 0.0001). A comparison of the early postoperative period (POD1-90) with long-term support (POD>90) showed an increase in thrombus length originating from the transition zone (1.96 ± 3.41 mm vs. 3.03 ± 2.91 mm; p = 0.013). CONCLUSIONS: A sintered titanium surface at the entry site is crucial to enable anchoring of myocardial tissue to the cannula. As thrombus growth progresses on polished surfaces, a greater sintered length seems to be beneficial. After an initial three-month healing period, thrombus load appears to decline during prolonged support duration at the sintered entry site but not at the transition zone.


Subject(s)
Heart-Assist Devices , Thrombosis , Cannula/adverse effects , Heart Ventricles/surgery , Heart-Assist Devices/adverse effects , Hemodynamics , Humans , Thrombosis/etiology
17.
Artif Organs ; 46(1): 155-158, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34605037

ABSTRACT

A patient was admitted in cardiogenic shock and a constant decrease of pump flow requiring combined inotropic support. To evaluate the cause, echocardiography and a ramp test were performed. The results suggested a LVAD related problem - particularly a suspected outflow graft obstruction. Wether CT scan nor angiography confirmed the assumption. However, a post-mortem LVAD examination revealed an outflow obstruction caused by a fungal thrombus formation invisible for standard imaging procedures.


Subject(s)
Candida/isolation & purification , Heart-Assist Devices/microbiology , Shock, Cardiogenic/etiology , Thrombosis/microbiology , Candidiasis/pathology , Echocardiography , Heart-Assist Devices/adverse effects , Humans , Male , Middle Aged , Myocardial Ischemia/therapy , Tomography, X-Ray Computed
18.
Artif Organs ; 46(5): 908-921, 2022 May.
Article in English | MEDLINE | ID: mdl-34904259

ABSTRACT

BACKGROUND: Cardiopulmonary bypass (CPB) during left ventricular assist device (LVAD) implantation provides circulatory support and allows for safe inspection of the left ventricle (LV), whereas circulatory support by veno-arterial extracorporeal life support (va-ECLS) or off-pump implantation may reduce postoperative bleeding and inflammatory response. METHODS: Retrospective analysis of 616 consecutive adult patients who received an LVAD via median sternotomy between January 1, 2015 and December 31, 2019. All patients undergoing concomitant intracardiac procedures other than closure of persistent foramen ovale or atrial septal defect and redo surgeries were excluded from the analysis. The remaining patients (n = 222) were divided into two groups and 1:1 propensity score-matched regarding preoperative parameters: patients who underwent LVAD implantation with LV inspection employing CPB (CPB group, n = 62) and without LV inspection on va-ECLS or off-pump (non-CPB group, n = 62). RESULTS: The groups were well balanced with regard to preoperative baseline characteristics (standard difference <0.1). Patients in the CPB group required more blood transfusions (median 2 vs. 0 units, p = 0.031) during surgery and in the first 24 h afterwards. The median intensive care unit stay was longer in the CPB group (18 vs. 11 days, p = 0.021). The CPB group showed an absence of perioperative stroke and a smaller number of events per patient-year for postoperative ischemic stroke (0.02 vs. 0.12, p = 0.003). 30-day survival (87% vs. 87.1%) and 1-year survival (80.3% vs. 74%) were similar in both groups (p = 0.78). CONCLUSION: Visual LV inspection on CPB may reduce the risk of postoperative ischemic stroke. Despite the negative effects of employing CPB in lieu of other intraoperative strategies, survival was similar in both groups.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Adult , Cardiopulmonary Bypass , Extracorporeal Membrane Oxygenation/methods , Heart Ventricles , Heart-Assist Devices/adverse effects , Humans , Retrospective Studies , Treatment Outcome
19.
Thorac Cardiovasc Surg ; 70(6): 452-457, 2022 09.
Article in English | MEDLINE | ID: mdl-35998669

ABSTRACT

The evolution and progress in cardiovascular medicine and substantial changes in the German health care system require both a reflection of the principles of patient-centered care in general and an update of the criteria that define a department of cardiac surgery in Germany. This position paper lists the core requirements for a cardiac surgical department with regard to infrastructure, facilities, necessary staff, and standard of care (processes). This standard may be used by hospitals and health care providers to ensure the safety and quality of cardiac surgical departments in Germany.


Subject(s)
Cardiac Surgical Procedures , Cardiac Surgical Procedures/adverse effects , Delivery of Health Care , Germany , Humans , Treatment Outcome
20.
Thorac Cardiovasc Surg ; 70(2): 136-142, 2022 Mar.
Article in German | MEDLINE | ID: mdl-34963180

ABSTRACT

High-quality care of cardiac surgical patients requires the employment and recruiting of qualified medical professionals with minimal fluctuation of staff members. This aspect becomes increasingly difficult due to the current shortage of skilled professionals as well as the present framework conditions of the German Healthcare System. The implementation of physician assistants (PA) in cardiac surgery departments may augment existing human resource concepts in an innovative and sustainable manner, tailored to meet department specific requirements. Long-term experiences from Anglo-American countries prove that the implementation of a PA system may stabilize or potentially even improve medical treatment quality. At the same time, cardiac surgical residents may be relieved from routine tasks, releasing additional time resources for a solid and diverse specialist training. Furthermore, positive effects on economic aspects of an institution may be possible. The required delegation of medical tasks to allied health professionals already has a legal basis in Germany, while a specific legal framework tailored to physician assistants does not exist yet. In this context, it is an important aspect that medical associations define a reliable catalog of tasks that may be delegated to physician assistants. Under evaluation of medical, legal and economic aspects and in a structured manner, this position paper defines medical tasks of physician assistants in cardiac surgery.


Subject(s)
Physician Assistants , Delivery of Health Care , Germany , Humans , Physician Assistants/education , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL