Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Ultrasound Obstet Gynecol ; 62(1): 61-68, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36484491

ABSTRACT

OBJECTIVES: To compile a list of instant diagnoses of major fetal anomalies, and to present their sonographic descriptors and test them in a retrospective series of fetuses with congenital anomalies managed at our center. METHODS: The first step was to identify major anomalies that meet the following criteria: (1) can be diagnosed directly and unequivocally on the basis of a set of descriptors evident on a single sonographic view; (2) are among those more commonly diagnosed in utero; (3) represent major lethal or life-threatening malformations or anomalies for which no or only palliative surgery can be performed. For each of these anomalies, a sonographic descriptor was produced. The second step was to test the descriptors of the instant diagnoses in all cases with these anomalies evaluated since January 2000 in our Fetal Medicine Unit, retrieved from our electronic database. For each congenital anomaly-sonographic descriptor pair we then evaluated the presence vs absence of an unequivocal relationship between anomaly and descriptor, assessing: whether a particular descriptor in a set reference plane identified unequivocally the anomaly, i.e. the same descriptor could not be found in any other malformation; and whether a particular anomaly presented the corresponding descriptor in all cases. Finally, we evaluated whether the sonographic descriptors could be applied in all trimesters or only selectively, considering the natural history of the 20 instant diagnoses. RESULTS: Of the 20 instant diagnoses, five involved the central/peripheral nervous system (exencephaly/anencephaly, alobar/semilobar holoprosencephaly, cephalocele, open spinal dysraphism, complete agenesis of corpus callosum), five involved the heart (hypoplastic left heart syndrome, complete atrioventricular septal defect, severe Ebstein's anomaly, critical aortic stenosis, transposition of the great arteries), five involved the abdominal wall (left-sided congenital diaphragmatic hernia, exomphalos, gastroschisis, body-stalk anomaly) or gastrointestinal tract (duodenal atresia), and five involved the remaining systems (three urinary (autosomal recessive polycystic kidney disease, multicystic dysplastic kidney, lower urinary tract obstruction), two skeletal (transverse limb defect, radial ray defect)). All of the descriptors were found to identify unequivocally the related malformations, whereas four of the malformations were not associated with their reference descriptors in every case. For example, congenital diaphragmatic hernia (left-sided) presented without the stomach in the thorax in 42/93 (45.2%) cases. Due to the natural history of the condition, not all signs were recognizable in the first trimester, some becoming evident only from the second trimester onwards. CONCLUSION: We have defined sonographic descriptors that enable an unequivocal instant diagnosis for a list of 20 major congenital anomalies: the 'INDIAMAN-20' (INstant DIAgnosis of Major ANomalies) protocol. We believe that using this approach may facilitate focused training of less experienced operators and that it may be incorporated into artificial intelligence and deep learning protocols, further boosting the instant prenatal recognition of these lethal or life-threatening malformations. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Hernias, Diaphragmatic, Congenital , Transposition of Great Vessels , Ultrasonography, Prenatal , Female , Humans , Pregnancy , Artificial Intelligence , Pregnancy Trimester, First , Retrospective Studies , Ultrasonography, Prenatal/methods
2.
Ultrasound Obstet Gynecol ; 61(5): 577-586, 2023 05.
Article in English | MEDLINE | ID: mdl-36240512

ABSTRACT

OBJECTIVES: To report on the early detection of congenital heart disease (CHD) in low- and high-risk populations managed at our hospital; and perform a detailed analysis of false-negative diagnoses, in order to derive possible recommendations on how to reduce their incidence. METHODS: This was a retrospective observational study analyzing cases which underwent an ultrasound examination at the end of the first trimester at the Fetal Medicine and Surgery Unit of Gaslini Children's Hospital, Genoa, Italy, in the period January 2015 to December 2021. The study population included both low-risk pregnancies that underwent standard first-trimester combined screening and high-risk ones referred to our unit because of a positive combined test or suspicion of fetal anomalies raised in a regional community hospital. For each case, the following variables were retrieved and analyzed: number of fetuses, maternal body mass index, gestational age at first-trimester screening, whether the pregnancy was low or high risk, nuchal translucency thickness (normal or > 99th  centile), type of CHD, associated extracardiac anomalies, karyotype and pregnancy outcome. For low-risk pregnancies, suspicion of CHD was also recorded. In low-risk cases, sonographic cardiac screening comprised evaluation of the four-chamber view (grayscale and color/power Doppler) and three-vessel-and-trachea view (color/power Doppler). High-risk cases underwent early fetal echocardiography. False-negative cases were categorized according to likely cause of the missed diagnosis, as follows: human factor; technical factor; acoustic-window factor. RESULTS: Gestational age at ultrasound ranged from 12 + 0 to 13 + 6 weeks (crown-rump length (CRL), 50.1-84.0 mm) in the low-risk group and from 11 + 5 to 13 + 6 weeks (CRL, 45.1-84.0 mm) in the high-risk group. Over the 7-year study period, 7080 pregnancies were evaluated in the first trimester. Of these, 6879 (7167 fetuses) were low-risk and 201 were high-risk cases. In the low-risk group, there were 30 fetuses with CHD (including 15 major and 15 minor CHD), yielding a prevalence of 4.2/1000 (2.1/1000 for major CHD). Nine of the 30 CHD cases were suspected at screening ultrasound (7/15 major CHD). Excluding cases in which the CHD would not be expected to be associated with a modification of the screening views and would therefore not be detectable on screening ultrasound, 7/12 cases of major CHD were detected, corresponding to a sensitivity of 58.3%. Among the 201 high-risk cases, there were 46 fetuses with CHD (including 44 major and two minor CHD), of which 43 were detected, corresponding to a sensitivity for early fetal echocardiography of 93.5%, or 97.7% if the two cases that were unlikely to be detectable on first-trimester screening were excluded. Analysis of the 11 (of 24) false-negative cases that would be expected to be picked up on screening views revealed that human error (image interpretation and/or scanning approach) was involved in all 11 cases and technical factors (excessive color priority (color-balance function) and/or incorrect plane alignment) were present in two. There was impairment of the acoustic window (associated with maternal obesity and/or twin gestation) as a cofactor in five of the 11 cases. CONCLUSIONS: The sensitivity for detection of major CHD of early cardiac screening in low-risk pregnancy is under 60%, partly due to the natural history of CHD and, it seems, partly relating to human error and technical issues with image quality. Factors associated with false-negative diagnoses may be categorized into three types: human error, technical factors and acoustic-window impairment. We recommend: appropriate assessment with fetal posterior spine; that sufficient time is spent on assessment of the fetal situs; and that color/power Doppler settings are adapted to the individual case. A lower threshold for referring doubtful cases for early fetal echocardiography should be adopted in cases of maternal obesity and in twin gestation. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Heart Defects, Congenital , Obesity, Maternal , Child , Pregnancy , Humans , Female , Infant , Ultrasonography, Prenatal/methods , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/epidemiology , Pregnancy Trimester, First , Gestational Age , Fetal Heart/diagnostic imaging , Fetal Heart/abnormalities
3.
Eur J Cardiothorac Surg ; 18(5): 575-82, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11053820

ABSTRACT

OBJECTIVE: This study was carried out to evaluate whether the type of pump used for cardiopulmonary bypass (CPB; roller vs. centrifugal) can affect mortality or the neurological outcomes of adult cardiac surgery patients. METHODS: Between 1994 and June 1999, 4000 consecutive patients underwent coronary and/or valve surgery at our hospital; of these, 2213 (55.3%) underwent surgery with centrifugal pump use, while 1787 (44.7%) were operated on with a roller pump. The effect of the type of the pump and of 36 preoperative and intraoperative risk factors for perioperative death, permanent neurological deficit and coma were assessed using univariate and multivariate analyses. RESULTS: The overall in-hospital mortality rate was 2.2% (88/4000), permanent neurological deficit occurred in 2.0% (81/4000) of patients, and coma in 1.3% (52/4000). There was no difference in hospital mortality between patients operated with the use of centrifugal pumps and those operated with roller pumps (50/2213 (2.3%) vs. 38/1787 (2.1%); P=0.86). On the other hand, patients who underwent surgery with centrifugal pumps had lower permanent neurological deficit (34/2213, (1.5%) vs. 47/1787 (2.6%); P=0.020) and coma (20/2213 (0.9%) vs. 32/1787 (1.8%); P=0.020) rates than patients operated with roller pumps. Multivariate analysis showed CPB time, previous TIA and age as risk factors for permanent neurological deficit, while centrifugal pump use emerged as protective. Multivariate risk factors for coma were CPB time, previous vascular surgery and age, while centrifugal pump use was protective. CONCLUSIONS: Centrifugal pump use is associated with a reduced rate of major neurological complications in adult cardiac surgery, although this is not paralleled by a decrease in in-hospital mortality.


Subject(s)
Cardiopulmonary Bypass/adverse effects , Cardiopulmonary Bypass/instrumentation , Aged , Analysis of Variance , Brain Injuries/etiology , Cardiopulmonary Bypass/mortality , Coma/etiology , Coronary Artery Bypass , Female , Heart Valve Prosthesis Implantation , Hospital Mortality , Humans , Ischemic Attack, Transient/complications , Logistic Models , Male , Middle Aged , Retrospective Studies , Risk Factors , Treatment Outcome
4.
Ital Heart J ; 2(12): 900-3, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11838336

ABSTRACT

BACKGROUND: The LAST operation represents a good option for single left anterior descending artery (LAD) revascularization. We report our preliminary experience with the LAST operation performed with the aid of the "da Vinci" Intuitive robotic system. METHODS: From January 2000 to May 2001, 12 patients (11 males and 1 female, mean age 62 +/- 8 years) underwent the LAST operation. All patients had a proximal LAD lesion either not suitable for coronary angioplasty or unsuccessfully treated at coronary angioplasty previously. The mean preoperative ejection fraction was 55 +/- 5%. In all patients, left internal mammary artery (LIMA) harvesting was carried out endoscopically using robotic technology. After heparin administration the LIMA was distally divided to check the adequacy of the blood flow. An incision of about 6 cm was then made in the appropriate intercostal space and the LAD was exposed using a special costal retractor. Following the insertion of a temporary intracoronary shunt, the LIMA was anastomosed to the LAD. RESULTS: No hospital or delayed death occurred. Uneventful conversion to midline sternotomy was necessary in one patient who developed ischemic changes and hemodynamic instability. One patient had a revision for postoperative bleeding. All patients were discharged within the first postoperative week and in 4 of them optimal patency of the LIMA graft was angiographically documented. CONCLUSIONS: The use of robotic technology seems to overcome all the drawbacks associated with the LAST operation and enhances the role of minimally invasive surgery in coronary artery revascularization.


Subject(s)
Internal Mammary-Coronary Artery Anastomosis/instrumentation , Robotics , Aged , Coronary Vessels/surgery , Endoscopy/methods , Equipment Design/instrumentation , Female , Follow-Up Studies , Humans , Male , Mammary Arteries/surgery , Middle Aged , Surgery, Computer-Assisted/instrumentation , Treatment Outcome , Vascular Patency/physiology
5.
Anesth Analg ; 89(1): 26-31, 1999 Jul.
Article in English | MEDLINE | ID: mdl-10389773

ABSTRACT

UNLABELLED: We studied the effects of the anesthetics commonly used in cardiac surgery on platelet function. Fentanyl, droperidol, succinylcholine, pancuronium, thiopental, and diazepam at therapeutic concentrations were tested for their in vitro effects on the expression of platelet membrane glycoproteins Ib and IIbIIIa (GpIb, GpIIb-IIIa) and of P-selectin in anticoagulated whole blood by flow cytometry. The expression of P-selectin was determined under basal conditions, after the incubation of blood with adenosine diphosphate (ADP) 10 micromol/L, and the stable prostaglandin endoperoxide analog U46619 1 micromol/L. No drug affected the expression of P-selectin in unstimulated and ADP- or U46619-stimulated platelets, with the exception of thiopental, which markedly decreased the U46619-induced expression of P-selectin. Thiopental concentration-dependently inhibited U46619-induced and ADP-induced platelet aggregation, with effects on U46619-induced aggregation at therapeutic concentrations. To assess ex vivo effects, the same platelet markers were also assessed in blood obtained from 10 patients undergoing elective coronary surgery. Compared with basal values, platelet response to U46619 was significantly reduced just after the administration of anesthetic drugs, and the effect persisted for 48 h after surgery. Our study suggests that, at therapeutic concentrations, thiopental inhibits U46619-induced platelet activation both in vitro and ex vivo. The mechanisms responsible of this effect, together with its clinical significance, require further investigation. IMPLICATIONS: Thiopental inhibited prostaglandin-induced platelet activation at therapeutic concentrations both in vitro and ex vivo in cardiac surgical patients whereas adenosine diphosphate-induced activation was affected only at supratherapeutic drug concentrations. Thus, administration of sodium thiopental may contribute to the in vivo impairment of platelet function in patients undergoing elective cardiac surgery.


Subject(s)
Anesthetics, Intravenous/pharmacology , Blood Platelets/drug effects , Cardiac Surgical Procedures , Thiopental/pharmacology , 15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5,13-dienoic Acid/pharmacology , Adenosine Diphosphate/pharmacology , Adult , Aged , Blood Platelets/physiology , Female , Humans , Male , Middle Aged , P-Selectin/analysis , Platelet Glycoprotein GPIIb-IIIa Complex/analysis
SELECTION OF CITATIONS
SEARCH DETAIL