1.
Int J Mol Sci ; 24(15)2023 Aug 02.
Article in English | MEDLINE | ID: mdl-37569707

ABSTRACT

COVID-19 is an ongoing, global pandemic caused by the novel, highly infectious SARS-CoV-2 virus. Efforts to mitigate the effects of SARS-CoV-2, such as mass vaccination and development of monoclonal therapeutics, require precise measurements of correlative, functional neutralizing antibodies that block virus infection. The development of rapid, safe, and easy-to-use neutralization assays is essential for faster diagnosis and treatment. Here, we developed a vesicular stomatitis virus (VSV)-based neutralization assay with two readout methods, imaging and flow cytometry, that were capable of quantifying varying degrees of neutralization in patient serum samples. We tested two different spike-pseudoviruses and conducted a time-course assay at multiple multiplicities of infection (MOIs) to optimize the assay workflow. The results of this assay correlate with the results of previously developed serology and surrogate neutralization assays. The two pseudovirus readout methods produced similar values of 50% neutralization titer values. Harvest-free in situ readouts for live-cell imaging and high-throughput analysis results for flow cytometry can provide unique capabilities for fast evaluation of neutralization, which is critical for the mitigation of future pandemics.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Flow Cytometry , Antibodies, Viral , Neutralization Tests/methods , Antibodies, Neutralizing
2.
Int J Mol Sci ; 24(21)2023 Oct 28.
Article in English | MEDLINE | ID: mdl-37958688

ABSTRACT

COVID-19 has highlighted challenges in the measurement quality and comparability of serological binding and neutralization assays. Due to many different assay formats and reagents, these measurements are known to be highly variable with large uncertainties. The development of the WHO international standard (WHO IS) and other pool standards have facilitated assay comparability through normalization to a common material but does not provide assay harmonization nor uncertainty quantification. In this paper, we present the results from an interlaboratory study that led to the development of (1) a novel hierarchy of data analyses based on the thermodynamics of antibody binding and (2) a modeling framework that quantifies the probability of neutralization potential for a given binding measurement. Importantly, we introduced a precise, mathematical definition of harmonization that separates the sources of quantitative uncertainties, some of which can be corrected to enable, for the first time, assay comparability. Both the theory and experimental data confirmed that mAbs and WHO IS performed identically as a primary standard for establishing traceability and bridging across different assay platforms. The metrological anchoring of complex serological binding and neuralization assays and fast turn-around production of an mAb reference control can enable the unprecedented comparability and traceability of serological binding assay results for new variants of SARS-CoV-2 and immune responses to other viruses.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Antibodies, Monoclonal , Biological Assay , Data Analysis , Antibodies, Viral , Antibodies, Neutralizing
3.
Int J Mol Sci ; 22(15)2021 Jul 31.
Article in English | MEDLINE | ID: mdl-34361020

ABSTRACT

A stochastic model of the flow cytometer measurement process was developed to assess the nature of the observed coefficient of variation (CV%) of the mean fluorescence intensity (MFI) from a population of labeled microspheres (beads). Several sources of variability were considered: the total number of labels on a bead, the path through the laser beam, the optical absorption cross-section, the quantum yield, the numerical aperture of the collection optics, and the photoelectron conversion efficiency of the photomultiplier (PMT) cathode. The variation in the number of labels on a bead had the largest effect on the CV% of the MFI of the bead population. The variation in the path of the bead through the laser beam was minimized using flat-top lasers. The variability in the average optical properties of the labels was of minor importance for beads with sufficiently large number of labels. The application of the bead results to the measured CV% of labeled B cells indicated that the measured CV% was a reliable measure of the variability of antibodies bound per cell. With some modifications, the model can be extended to multicolor flow cytometers and to the study of CV% from cells with low fluorescence signal.


Subject(s)
B-Lymphocytes/cytology , Flow Cytometry/standards , Microspheres , Analysis of Variance , Flow Cytometry/methods , Humans , Reproducibility of Results , Stochastic Processes
4.
Int J Mol Sci ; 22(5)2021 Mar 08.
Article in English | MEDLINE | ID: mdl-33800363

ABSTRACT

Quantitative and robust serology assays are critical measurements underpinning global COVID-19 response to diagnostic, surveillance, and vaccine development. Here, we report a proof-of-concept approach for the development of quantitative, multiplexed flow cytometry-based serological and neutralization assays. The serology assays test the IgG and IgM against both the full-length spike antigens and the receptor binding domain (RBD) of the spike antigen. Benchmarking against an RBD-specific SARS-CoV IgG reference standard, the anti-SARS-CoV-2 RBD antibody titer was quantified in the range of 37.6 µg/mL to 31.0 ng/mL. The quantitative assays are highly specific with no correlative cross-reactivity with the spike proteins of MERS, SARS1, OC43 and HKU1 viruses. We further demonstrated good correlation between anti-RBD antibody titers and neutralizing antibody titers. The suite of serology and neutralization assays help to improve measurement confidence and are complementary and foundational for clinical and epidemiologic studies.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19 Serological Testing/standards , COVID-19/blood , COVID-19/immunology , Neutralization Tests/methods , Neutralization Tests/standards , SARS-CoV-2/immunology , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , Cross Reactions , Flow Cytometry/methods , Fluorescence , Humans , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin M/blood , Immunoglobulin M/immunology , Microspheres , Receptors, Virus/chemistry , Receptors, Virus/immunology , Spike Glycoprotein, Coronavirus/chemistry , Spike Glycoprotein, Coronavirus/immunology
5.
Int J Mol Sci ; 21(17)2020 Aug 24.
Article in English | MEDLINE | ID: mdl-32846978

ABSTRACT

A stochastic reaction-diffusion model was developed to describe the binding of labeled monoclonal antibodies (mAbs) to CD4 receptors on the surface of T cells. The mAbs diffused to, adsorbed on, and underwent monovalent and bivalent binding to CD4 receptors on the cell surface. The model predicted the time-dependent nature of all populations involved in the labeling process. At large time, the populations reached equilibrium values, giving the number of antibodies bound to the T cell (ABC) defined as the sum of monovalently and bivalently bound mAbs. The predicted coefficient of variation (CV%) of the (ABC) values translated directly to a corresponding CV% of the measured mean fluorescence intensity (MFI). The predicted CV% was about 0.2% from the intrinsic fluctuations of the stochastic reaction process, about 5% after inclusion of the known fluctuations in the number of available CD4 receptors, and about 11% when fluctuations in bivalent binding affinity were included. The fluorescence detection process is expected to contribute approximately 7%. The abovementioned contributions to CV% sum up to approximately 13%. Work is underway to reconcile the predicted values and the measured values of 17% to 22%.


Subject(s)
Antibodies, Monoclonal/metabolism , CD4 Antigens/metabolism , Models, Theoretical , T-Lymphocytes/metabolism , Antibody Affinity , Cells, Cultured , Diffusion , Humans , Protein Binding , Stochastic Processes , Substrate Specificity
6.
Article in English | MEDLINE | ID: mdl-34877142

ABSTRACT

The CD4 glycoprotein is a component of the T cell receptor complex which plays an important role in the human immune response. This manuscript describes the measurement and modeling of the binding of fluorescently labeled anti-human CD4 monoclonal antibodies (mAb; SK3 clone) to CD4 receptors on the surface of human peripheral blood mononuclear cells (PBMC). CD4 mAb fluorescein isothiocyanate (FITC) and CD4 mAb allophycoerythrin (APC) conjugates were obtained from commercial sources. Four binding conditions were performed, each with the same PBMC sample and different CD4 mAb conjugate. Each binding condition consisted of the PBMC sample incubated for 30 min in labeling solutions containing progressively larger concentrations of the CD4 mAb-label conjugate. After the incubation period, the cells were re-suspended in PBS-based buffer and analyzed using a flow cytometer to measure the mean fluorescence intensity (MFI) of the labeled cell populations. A model was developed to estimate the equilibrium concentration of bound CD4 mAb-label conjugates to CD4 receptors on PBMC. A set of parameters was obtained from the best fit of the model to the measured MFI data and the known number of CD4 receptors on PBMC surface. Divalent and monovalent binding had to be invoked for the APC and FITC CD4 mAb conjugates, respectively. This suggests that the mAb binding depends on the size of the label, which has significant implications for quantitative flow cytometry. The study supports the National Institute of Standards and Technology program to develop quantitative flow cytometry measurements.

7.
J Res Natl Inst Stand Technol ; 121: 264-281, 2016.
Article in English | MEDLINE | ID: mdl-34434623

ABSTRACT

A procedure will be described to assign to each dyed microsphere a number called the Equivalent number of Reference Fluorophores (ERF). The ERF unit gives the number of reference fluorophores in solution which produce the same fluorescence signal as a single dyed microsphere. In the first step, fluorescence measurements were carried out on serial dilutions of a solution of reference fluorophores. The resulting fluorescence intensities and the corresponding concentrations were used to calibrate the response of the fluorometer. The calibration consisted of establishing a linear relation between the intensities and concentrations. In the second step, the fluorescence intensity from a suspension of microspheres was measured in order to determine the equivalent concentration of reference fluorophores which gave the same fluorescence intensity as the suspension of microspheres. This was performed by utilizing the calibration line obtained in the first step. In the third step, a flow cytometer and a light obscuration apparatus were used to measure the total concentration of microspheres in the suspensions used for the fluorescence measurements. In addition to the total microsphere concentration, the flow cytometer also enabled the measurement of the concentration of a sub population of microspheres which are used to calibrate the fluorescence scale of a flow cytometer. The fourth step utilized the data collected in steps one, two, and three to assign a value of ERF to individual microspheres. The set of microspheres with assigned ERF values will be used to establish a linear fluorescence scale in each channel of a flow cytometer. The discussion will emphasize the estimate of uncertainties in each step of the assignment process.

8.
Cytometry A ; 87(3): 244-53, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25655255

ABSTRACT

A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) µL(-1) CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment.


Subject(s)
CD4-Positive T-Lymphocytes , Fluorescein-5-isothiocyanate , Leukocytes, Mononuclear , Phenotype , Antibodies/analysis , CD4 Lymphocyte Count/methods , CD4 Lymphocyte Count/standards , CD4-Positive T-Lymphocytes/chemistry , Fluorescein-5-isothiocyanate/analysis , Freeze Drying/methods , Humans , Leukocytes, Mononuclear/chemistry , Pilot Projects
9.
J Res Natl Inst Stand Technol ; 119: 610-28, 2014.
Article in English | MEDLINE | ID: mdl-26601047

ABSTRACT

Measurements are presented of the absorbance, fluorescence emission, fluorescence quantum yield, and fluorescence lifetime of CdSe/ZnS nanocrystals, also known as quantum dots (QDs). The study included three groups of nanocrystals whose surfaces were either passivated with organic molecules, modified further with carboxyl groups, or conjugated with CD14 mouse anti-human antibodies. The surface modifications had observable effects on the optical properties of the nanocrystals. The oscillator strength (OS) of the band edge transition was about 1.0 for the nanocrystals emitting at 565 nm, 605 nm, and 655 nm. The OS could not be determined for QDs with emission at 700 nm and 800 nm. The fluorescence lifetimes varied from 26 ns for nanocrystals emitting near 600 nm to 150 ns for nanocrystals emitting near 800 nm. The quantum yield ranged between 0.4 and 0.9 for the nanocrystals in this study. A brightness index (BI) was used to evaluate the suitability of the nanocrystal labels for flow cytometer measurements. Most QD labels are at least as bright as fluorescein for applications in flow cytometer assays with 488 nm excitation. For optimal brightness the QDs should be excited with 405 nm light. We observed a strong dependence of the QD absorbance at 250 nm on the surface modification of the QD.

10.
Article in English | MEDLINE | ID: mdl-26401422

ABSTRACT

Measurements of absorbance and fluorescence emission were carried out on aqueous suspensions of polystyrene (PS) microspheres with a diameter of 2.5 µm using a spectrophotometer with an integrating sphere detector. The apparatus and the principles of measurements were described in our earlier publications. Microspheres with and without green BODIPY(@) dye were measured. Placing the suspension inside an integrating sphere (IS) detector of the spectrophotometer yielded (after a correction for fluorescence emission) the absorbance (called A in the text) due to absorption by BODIPY(@) dye inside the microsphere. An estimate of the absorbance due to scattering alone was obtained by subtracting the corrected BODIPY(@) dye absorbance (A) from the measured absorbance of a suspension placed outside the IS detector (called A1 in the text). The absorption of the BODIPY(@) dye inside the microsphere was analyzed using an imaginary index of refraction parameterized with three Gaussian-Lorentz functions. The Kramer-Kronig relation was used to estimate the contribution of the BODIPY(@) dye to the real part of the microsphere index of refraction. The complex index of refraction, obtained from the analysis of A, was used to analyze the absorbance due to scattering ((A1 - A) in the text). In practice, the analysis of the scattering absorbance, A1-A, and the absorbance, A, was carried out in an iterative manner. It was assumed that A depended primarily on the imaginary part of the microsphere index of refraction with the other parameters playing a secondary role. Therefore A was first analyzed using values of the other parameters obtained from a fit to the absorbance due to scattering, A1-A, with the imaginary part neglected. The imaginary part obtained from the analysis of A was then used to reanalyze A1-A, and obtain better estimates of the other parameters. After a few iterations, consistent estimates were obtained of the scattering and absorption cross sections in the wavelength region 300 nm to 800 nm.

11.
Cytometry A ; 81(7): 567-75, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22539147

ABSTRACT

To transform the linear fluorescence intensity scale obtained with fluorescent microspheres to an antibody bound per cell (ABC) scale, a biological cell reference material is needed. Optimally, this material should have a reproducible and tight ABC value for the expression of a known clinical reference biomarker. In this study, we characterized commercially available cryopreserved peripheral blood mononuclear cells (PBMCs) and two lyophilized PBMC preparations, Cyto-Trol and PBMC-National Institute for Biological Standard and Control (NIBSC) relative to freshly prepared PBMC and whole blood samples. It was found that the ABC values for CD4 expression on cryopreserved PBMC were consistent with those of freshly obtained PBMC and whole blood samples. By comparison, the ABC value for CD4 expression on Cyto-Trol is lower and the value on PBMC-NIBSC is much lower than those of freshly prepared cell samples using both conventional flow cytometry and CyTOF™ mass cytometry. By performing simultaneous surface and intracellular staining measurements on these two cell samples, we found that both cell membranes are mostly intact. Moreover, CD4(+) cell diameters from both lyophilized cell preparations are smaller than those of PBMC and whole blood. This could result in steric interference in antibody binding to the lyophilized cells. Further investigation of the fixation effect on the detected CD4 expression suggests that the very low ABC value obtained for CD4(+) cells from lyophilized PBMC-NIBSC is largely due to paraformaldehyde fixation; this significantly decreases available antibody binding sites. This study provides confirmation that the results obtained from the newly developed mass cytometry are directly comparable to the results from conventional flow cytometry when both methods are standardized using the same ABC approach.


Subject(s)
Antigens/metabolism , CD4-Positive T-Lymphocytes/metabolism , Flow Cytometry , Calibration , Cell Membrane/metabolism , Cell Separation , Fixatives/chemistry , Formaldehyde/chemistry , Humans , Permeability , Polymers/chemistry , Staining and Labeling , Tissue Fixation
12.
Nanomaterials (Basel) ; 12(18)2022 Sep 08.
Article in English | MEDLINE | ID: mdl-36144906

ABSTRACT

The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.

13.
J Res Natl Inst Stand Technol ; 116(3): 671-83, 2011.
Article in English | MEDLINE | ID: mdl-26989591

ABSTRACT

A procedure is described for assigning the number of equivalent reference fluorophores (ERF) values to microspheres labeled with a fluorophore designed to produce a fluorescence response in a given fluorescence channel of a multicolor flow cytometer. A fluorimeter was calibrated by a series of solutions of the reference fluorophores. The fluorimeter was used to obtain the microsphere fluorescence intensity, and a multicolor flow cytometer was used to obtain the microsphere concentration. The microsphere fluorescence intensity and the concentration were used to obtain the value of ERF for each model microsphere calibration standard. The procedure is described in detail only for microspheres with allophycocyanin (APC) immobilized on the surface. ERF values were also determined for microsphere calibrators for three other fluorescence channels: fluorescein isothiocyanate (FITC), phycoerythrin (PE), and Pacific Blue(PB). The four model microsphere calibrators provide a one point calibration for the four channels of a flow cytometer. By using software controls and changing the photomultiplier voltages, it is possible to obtain a multipoint calibration for each fluorescence channel using each microsphere calibrator.

14.
Cytometry B Clin Cytom ; 96(6): 508-513, 2019 11.
Article in English | MEDLINE | ID: mdl-30790450

ABSTRACT

BACKGROUND: Over 2,000 people a year in the United Kingdom need a bone marrow or blood stem cell transplant. It is important to accurately quantify the hematopoietic stem cells to predict whether the transplant will be successful in replenishing the immune system. However, they are present at low frequency, which complicates accurate quantification. The current gold standard method is single-platform flow cytometry using internal reference counting beads to determine the concentration of CD34 cells. However, volumetric flow cytometers have the ability to measure the acquisition volume, which removes the need for reference beads for calculation of cell concentrations. METHOD: In this study, we compared both methods for calculating CD34 cell concentrations in volumetric cytometers, using either the volume reading or the number of reference beads for calculation. In addition, the uncertainty of measurement for each method was estimated. RESULTS: The results show that both methods have similar uncertainties of measurement. Regression analysis showed low to no statistical difference in CD34 cell concentrations obtained with each method. CONCLUSIONS: Overall, this study suggests that the volumetric method is a valid approach but that the adoption of this technology may be hindered without some form of external calibration of volume readings to increase confidence in the measurement. © 2019 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society.


Subject(s)
Antigens, CD34/analysis , Flow Cytometry , Hematopoietic Stem Cells/cytology , Cell Count , Humans , Regression Analysis
15.
Cytometry A ; 73(4): 279-88, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18163471

ABSTRACT

A procedure is presented for calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure involves two steps. First, each of the fluorescence channels of the flow cytometer is calibrated using Ultra Rainbow beads with assigned values of equivalent number of reference fluorophores (ERF). The objective of this step is to establish a linear relation between the fluorescence signal in a given fluorescence channel of multicolor flow cytometers and the value of ERF. The second step involves a biological standard such as a lymphocyte with a known number of antibody binding sites (e.g., CD4 binding sites). The biological standard is incubated with antibodies labeled with one type of fluorophores for a particular fluorescence channel and serves to translate the ERF scale to an ABC scale. A significant part of the two-step calibration procedure involves the assignment of ERF values to the different populations of Ultra Rainbow beads. The assignment of ERF values quantifies the relative amount of embedded fluorophore mixture in each bead population. It is crucial to insure that the fluorescence signal in a given range of fluorescence emission wavelengths is related linearly to the assigned values of ERF. The biological standard has to poses a known number of binding sites for a given antibody. In addition, this antibody has to be amenable to labeling with different types of fluorophores associated with various fluorescence channels. The present work suggests that all of the requirements for a successful calibration of a multicolor flow cytometer in terms of ABC values can be fulfilled. The calibration procedure is based on firm scientific foundations so that it is easy to envision future improvements in accuracy and ease of implementation.


Subject(s)
Flow Cytometry/methods , Binding Sites , Calibration , Cell Separation/methods , Equipment Design , Fluorescence , Fluorescent Dyes , Microspheres , Reproducibility of Results , Spectrometry, Fluorescence/methods
16.
J Res Natl Inst Stand Technol ; 113(1): 17-28, 2008.
Article in English | MEDLINE | ID: mdl-27096110

ABSTRACT

A method is proposed for measuring the fluorescence quantum yield (QY) using a commercial spectrophotometer with a 150 mm integrating sphere (IS) detector. The IS detector is equipped with an internal cuvette holder so that absorbance measurements can be performed with the cuvette inside the IS. In addition, the spectrophotometer has a cuvette holder outside the IS for performing conventional absorbance measurements. It is shown that the fluorescence quantum yield can be obtained from a combination of absorbance measurements of the buffer and the analyte solution inside and outside the IS detector. Due to the simultaneous detection of incident and fluorescent photons, the absorbance measurements inside the IS need to be adjusted for the wavelength dependence of the photomultiplier detector and the wavelength dependence of the IS magnification factor. An estimate of the fluorescence emission spectrum is needed for proper application of the wavelength-dependent adjustments. Results are presented for fluorescein, quinine sulfate, myoglobin, rhodamine B and erythrosin B. The QY of fluorescein in 0.1 mol/L NaOH was determined as 0.90±0.02 where the uncertainty is equal to the standard deviation of three independent measurements. The method provides a convenient and rapid estimate of the fluorescence quantum yield. Refinements of the measurement model and the characteristics of the IS detector can in principle yield an accurate value of the absolute fluorescence quantum yield.

17.
J Res Natl Inst Stand Technol ; 113(5): 251-63, 2008.
Article in English | MEDLINE | ID: mdl-27096125

ABSTRACT

A method is described for obtaining the rate constant of the photodegradation process of fluorophores illuminated by a focused laser beam. The explicit kinetic equations, describing the population dynamics of excited singlet and triplet states, are averaged over the illuminated volume to describe the resulting fluorescence signal. The illumination is modulated at frequencies from 1 Hz to 100 Hz. Synchronous detection of the resulting fluorescence yields in-phase and quadrature components. The measurement of the ratio of quadrature to in-phase components at several power levels yields information on the photodegradation rate. Specifically it is shown that the data can be interpreted in a manner which yields the value of the photodegradation rate independently of other parameters entering the model. Experiments are performed with erythrosine B which has a large intersystem crossing rate to the triplet state. Measurements in solutions with different viscosities show that the photodegradation rate depends on the viscosity. This is interpreted as evidence for an intermolecular interaction mechanism. We explore the uncertainty of the estimated photodegradation constant taking into account the uncertainties of the measurements used in the synchronous detection technique.

18.
Methods Mol Biol ; 1678: 93-110, 2018.
Article in English | MEDLINE | ID: mdl-29071677

ABSTRACT

Multicolor flow cytometer assays are routinely used in clinical laboratories for immunophenotyping, monitoring disease and treatment, and determining prognostic factors. However, existing methods for quantitative measurements have not yet produced satisfactory results independent of flow cytometers used. This chapter details a procedure for quantifying surface and intracellular protein biomarkers by calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure includes the following critical steps: (a) quality control (QC) and performance characterization of the multicolor flow cytometer, (b) fluorescence calibration using hard dyed microspheres assigned with fluorescence intensity values in equivalent number of reference fluorophores (ERF), (c) compensation for correction of fluorescence spillover, and (d) application of a biological reference standard for translating the ERF scale to the ABC scale. The chapter also points out current efforts for implementing quantification of biomarkers in a manner which is independent of instrument platforms and reagent differences.


Subject(s)
Flow Cytometry/methods , Antibodies , CD4-Positive T-Lymphocytes/metabolism , Calibration , Flow Cytometry/standards , Fluorescent Dyes , Humans , Immunophenotyping , Microspheres , Quality Control , Reference Standards
19.
Biotechniques ; 43(1): 93-8, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17695258

ABSTRACT

The DNA binding protein nuclear factor kappaB (NF-kappaB) and the cellular signaling pathways in which it participates are the central coordinators of many biological processes, including innate and adaptive immune responses, oxidative stress response, and aging. NF-kappaB also plays a key role in diseases, for example, cancer A simple, convenient, and high-throughput detection of NF-kappaB activation is therefore important for systematically studying signaling pathways and for screening therapeutic drug targets. We describe a method based on fluorescence resonance energy transfer (FRET) to directly measure the amount of activated NF-kappaB. More specifically, a double-stranded DNA (dsDNA) probe was designed to contain a pair of FRET fluorophores at the same end of the probe and an endonuclease binding site within the NF-kappaB consensus sequence. The activated NF-kappaB was detected by FRET following the restriction enzyme digestion. Using three different analyte materials--(i) purified recombinant NF- kappaB p50, (ii) nuclear extracts, and (iii) whole cell lysates--we demonstrated that this assay is as sensitive as the traditional, widely used electrophoretic mobility shift assay (EMSA), but much less labor-intensive for measuring NF-kappaB DNA binding activities. In addition, this FRET-based assay can be easily adapted for high-throughput screening of NF-kappaB activation.


Subject(s)
DNA/metabolism , Fluorescence Resonance Energy Transfer/methods , NF-kappa B/metabolism , Cell Extracts , Electrophoretic Mobility Shift Assay , Endonucleases/metabolism , HeLa Cells , Humans , NF-kappa B/analysis , Protein Binding , Recombinant Proteins/metabolism
20.
Cytometry B Clin Cytom ; 72(6): 442-9, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17474131

ABSTRACT

BACKGROUND: Numerous methods for quantitative fluorescence calibration (QFC) have been developed to quantify receptor expression on lymphocytes. However, the results from the use of these different QFC methods vary considerably in the literature. To better identify the causes of these discrepancies, we measured CD4 expression using FITC and phycoerythrin (PE) conjugates to stain CYTO-TROL Control Cells and T-lymphocytes in whole blood and isolated cell preparations. We further examined pH of the cellular microenvironment as a cause of discordant results obtained with the FITC conjugate. METHODS: Calibration with Quantibrite PE-labeled microspheres and the use of unimolar CD4-PE conjugates provided direct measurement of the antibody bound per cell value (ABC) for CD4 expression on normal T-lymphocytes. Calibration for CD4-FITC monoclonal antibody (Mab) labeled CYTO-TROL Control Cells and normal T-lymphocytes was based on molecules of equivalent soluble fluorochrome (MESF) as determined by FITC-labeled microspheres traceable to NIST RM 8640. The MESF value for CD4-FITC Mab was determined that enabled the conversion of the MESF values obtained for CYTO-TROL cells to ABC. We investigated the likely pH change in the fluorescein microenvironments within FITC-labeled Mab and cells stained with FITC-labeled Mab using a pH sensitive indicator. RESULTS: The mean ABC value for T-lymphocytes prepared from fresh whole blood using CD4-PE conjugate (48,321) was consistent with previous results, and it was much higher than the mean ABC using CD4-FITC Mab (22,156). The mean ABC value for CYTO-TROL cells using CD4-PE conjugate (43,090) was also higher than that using CD4-FITC conjugate (34,734), although the discrepancy was not as great. Further studies suggested the discrepancy in CYTO-TROL results may be accounted for by the low pH of the membrane microenvironment, but the greater discrepancy in T-lymphocytes could not be fully explained. CONCLUSION: CD4 expression on fresh normal whole blood samples and CYTO-TROL cells can be consistently quantified in ABC units using Quantibrite PE quantification beads and unimolar CD4-PE conjugates. Quantification with CD4-FITC conjugate is not as consistent, but may be improved by the use of CD4 T-cells as biological calibrators. This approximation is valid only for surface receptors with consensus ABC values measured by different QFC methods serving as biological standards.


Subject(s)
CD4 Antigens/metabolism , Flow Cytometry/methods , Fluorescein , Fluorescent Dyes , Phycoerythrin , T-Lymphocytes/immunology , Antibodies, Monoclonal/immunology , Fluorescein-5-isothiocyanate , Humans , Hydrogen-Ion Concentration , Microspheres , Pigments, Biological , T-Lymphocytes/cytology