Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
J Physiol ; 600(12): 2973-2999, 2022 06.
Article in English | MEDLINE | ID: mdl-35639046

ABSTRACT

Opioid overdose suppresses brainstem respiratory circuits, causes apnoea and may result in death. Epidural electrical stimulation (EES) at the cervical spinal cord facilitated motor activity in rodents and humans, and we hypothesized that EES of the cervical spinal cord could antagonize opioid-induced respiratory depression in humans. Eighteen patients requiring surgical access to the dorsal surface of the spinal cord between C2 and C7 received EES or sham stimulation for up to 90 s at 5 or 30 Hz during complete (OFF-State) or partial suppression (ON-State) of respiration induced by remifentanil. During the ON-State, 30 Hz EES at C4 and 5 Hz EES at C3/4 increased tidal volume and decreased the end-tidal carbon dioxide level compared to pre-stimulation control levels. EES of 5 Hz at C5 and C7 increased respiratory frequency compared to pre-stimulation control levels. In the OFF-State, 30 Hz cervical EES at C3/4 terminated apnoea and induced rhythmic breathing. In cadaveric tissue obtained from a brain bank, more neurons expressed both the neurokinin 1 receptor (NK1R) and somatostatin (SST) in the cervical spinal levels responsive to EES (C3/4, C6 and C7) compared to a region non-responsive to EES (C2). Thus, the capacity of cervical EES to oppose opioid depression of respiration may be mediated by NK1R+/SST+ neurons in the dorsal cervical spinal cord. This study provides proof of principle that cervical EES may provide a novel therapeutic approach to augment respiratory activity when the neural function of the central respiratory circuits is compromised by opioids or other pathological conditions. KEY POINTS: Epidural electrical stimulation (EES) using an implanted spinal cord stimulator (SCS) is an FDA-approved method to manage chronic pain. We tested the hypothesis that cervical EES facilitates respiration during administration of opioids in 18 human subjects who were treated with low-dose remifentanil that suppressed respiration (ON-State) or high-dose remifentanil that completely inhibited breathing (OFF-State) during the course of cervical surgery. Dorsal cervical EES of the spinal cord augmented the respiratory tidal volume or increased the respiratory frequency, and the response to EES varied as a function of the stimulation frequency (5 or 30 Hz) and the cervical level stimulated (C2-C7). Short, continuous cervical EES restored a cyclic breathing pattern (eupnoea) in the OFF-State, suggesting that cervical EES reversed the opioid-induced respiratory depression. These findings add to our understanding of respiratory pattern modulation and suggest a novel mechanism to oppose the respiratory depression caused by opioids.


Subject(s)
Cervical Cord , Respiratory Insufficiency , Spinal Cord Injuries , Analgesics, Opioid/adverse effects , Apnea , Electric Stimulation/methods , Humans , Remifentanil , Respiratory Insufficiency/chemically induced , Respiratory Insufficiency/therapy , Spinal Cord/physiology
2.
J Orthop Res ; 2024 Jul 14.
Article in English | MEDLINE | ID: mdl-39004739

ABSTRACT

Effective treatment of large acetabular defects remains among the most challenging aspects of revision total hip arthroplasty (THA), due to the deficiency of healthy bone stock and degradation of the support columns. Generic uncemented components, which are favored in primary THA, are often unsuitable in revision cases, where the bone-implant contact may be insufficient for fixation, without significant reaming of the limited residual bone. This study presents a computational design strategy for automatically generating patient-specific implants that simultaneously maximize the bone-implant contact area, and minimize bone reaming while ensuring insertability. These components can be manufactured using the same additive manufacturing methods as porous components and may reduce cost and operating-time, compared to existing patient-specific systems. This study compares the performance of implants generated via the proposed method to optimally fitted hemispherical implants, in terms of the achievable bone-implant contact surface, and the volume of reamed bone. Computer-simulated results based on the reconstruction of a set of 15 severe pelvic defects (Paprosky 2A-3B) suggest that the patient-specific components increase bone-implant contact by 63% (median: 63%; SD: 44%; 95% CI: 52.3%-74.0%; RMSD: 42%), and reduce the volume of reamed bone stock by 97% (median: 98%; SD: 4%; 95% CI: 95.9%-97.4%; RMSD: 3.7%).

SELECTION OF CITATIONS
SEARCH DETAIL