ABSTRACT
BACKGROUND: Empagliflozin improves cardiovascular outcomes in patients with heart failure, patients with type 2 diabetes who are at high cardiovascular risk, and patients with chronic kidney disease. The safety and efficacy of empagliflozin in patients who have had acute myocardial infarction are unknown. METHODS: In this event-driven, double-blind, randomized, placebo-controlled trial, we assigned, in a 1:1 ratio, patients who had been hospitalized for acute myocardial infarction and were at risk for heart failure to receive empagliflozin at a dose of 10 mg daily or placebo in addition to standard care within 14 days after admission. The primary end point was a composite of hospitalization for heart failure or death from any cause as assessed in a time-to-first-event analysis. RESULTS: A total of 3260 patients were assigned to receive empagliflozin and 3262 to receive placebo. During a median follow-up of 17.9 months, a first hospitalization for heart failure or death from any cause occurred in 267 patients (8.2%) in the empagliflozin group and in 298 patients (9.1%) in the placebo group, with incidence rates of 5.9 and 6.6 events, respectively, per 100 patient-years (hazard ratio, 0.90; 95% confidence interval [CI], 0.76 to 1.06; P = 0.21). With respect to the individual components of the primary end point, a first hospitalization for heart failure occurred in 118 patients (3.6%) in the empagliflozin group and in 153 patients (4.7%) in the placebo group (hazard ratio, 0.77; 95% CI, 0.60 to 0.98), and death from any cause occurred in 169 (5.2%) and 178 (5.5%), respectively (hazard ratio, 0.96; 95% CI, 0.78 to 1.19). Adverse events were consistent with the known safety profile of empagliflozin and were similar in the two trial groups. CONCLUSIONS: Among patients at increased risk for heart failure after acute myocardial infarction, treatment with empagliflozin did not lead to a significantly lower risk of a first hospitalization for heart failure or death from any cause than placebo. (Funded by Boehringer Ingelheim and Eli Lilly; EMPACT-MI ClinicalTrials.gov number, NCT04509674.).
Subject(s)
Heart Failure , Myocardial Infarction , Sodium-Glucose Transporter 2 Inhibitors , Aged , Female , Humans , Male , Middle Aged , Benzhydryl Compounds/therapeutic use , Benzhydryl Compounds/adverse effects , Double-Blind Method , Follow-Up Studies , Glucosides/therapeutic use , Glucosides/adverse effects , Heart Failure/etiology , Heart Failure/mortality , Heart Failure/prevention & control , Hospitalization , Kaplan-Meier Estimate , Myocardial Infarction/complications , Myocardial Infarction/drug therapy , Myocardial Infarction/mortality , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Sodium-Glucose Transporter 2 Inhibitors/adverse effects , Treatment Outcome , Heart Disease Risk FactorsABSTRACT
BACKGROUND: Empagliflozin reduces the risk of heart failure (HF) events in patients with type 2 diabetes at high cardiovascular risk, chronic kidney disease, or prevalent HF irrespective of ejection fraction. Whereas the EMPACT-MI trial (Effect of Empagliflozin on Hospitalization for Heart Failure and Mortality in Patients With Acute Myocardial Infarction) showed that empagliflozin does not reduce the risk of the composite of hospitalization for HF and all-cause death, the effect of empagliflozin on first and recurrent HF events after myocardial infarction is unknown. METHODS: EMPACT-MI was a double-blind, randomized, placebo-controlled, event-driven trial that randomized 6522 patients hospitalized for acute myocardial infarction at risk for HF on the basis of newly developed left ventricular ejection fraction of <45% or signs or symptoms of congestion to receive empagliflozin 10 mg daily or placebo within 14 days of admission. In prespecified secondary analyses, treatment groups were analyzed for HF outcomes. RESULTS: Over a median follow-up of 17.9 months, the risk for first HF hospitalization and total HF hospitalizations was significantly lower in the empagliflozin compared with the placebo group (118 [3.6%] versus 153 [4.7%] patients with events; hazard ratio, 0.77 [95% CI, 0.60, 0.98]; P=0.031, for first HF hospitalization; 148 versus 207 events; rate ratio, 0.67 [95% CI, 0.51, 0.89]; P=0.006, for total HF hospitalizations). Subgroup analysis showed consistency of empagliflozin benefit across clinically relevant patient subgroups for first and total HF hospitalizations. The need for new use of diuretics, renin-angiotensin modulators, or mineralocorticoid receptor antagonists after discharge was less in patients randomized to empagliflozin versus placebo (all P<0.05). CONCLUSIONS: Empagliflozin reduced the risk of HF in patients with left ventricular dysfunction or congestion after acute myocardial infarction. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04509674.
Subject(s)
Benzhydryl Compounds , Glucosides , Heart Failure , Hospitalization , Myocardial Infarction , Sodium-Glucose Transporter 2 Inhibitors , Humans , Glucosides/therapeutic use , Benzhydryl Compounds/therapeutic use , Heart Failure/drug therapy , Heart Failure/mortality , Male , Female , Myocardial Infarction/drug therapy , Myocardial Infarction/mortality , Myocardial Infarction/complications , Aged , Middle Aged , Double-Blind Method , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Treatment Outcome , Stroke Volume/drug effectsABSTRACT
BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.
Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis , Prosthesis-Related Infections , Transcatheter Aortic Valve Replacement , Humans , Endocarditis, Bacterial/diagnostic imaging , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Incidence , Risk Factors , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Endocarditis/diagnostic imaging , Endocarditis/epidemiology , EchocardiographyABSTRACT
BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; Pâ =â .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; Pâ <â .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, Pâ <â .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padjâ <â 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.
Subject(s)
Aneurysm, False , Endocarditis, Bacterial , Endocarditis , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Abscess , Aneurysm, False/complications , Aneurysm, False/surgery , Coagulase , Endocarditis/epidemiology , Endocarditis/etiology , Endocarditis/surgery , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Humans , Renal Insufficiency, Chronic/complications , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effectsABSTRACT
In the recent years, ischemic brain injury related to embolization after transcatheter aortic valve replacement (TAVR) has received increased attention as new embolic protection strategies emerged to protect the brain. Diverse cerebral protection devices have been developed to reduce cerebral embolization during TAVR. These devices work through various mechanisms and are in different stages of clinical translation. This review provides the evidence-based review of peri-procedural stroke prevention during TAVR and summarizes currently available cerebral embolic protection devices.
Subject(s)
Embolic Protection Devices , Intracranial Embolism/prevention & control , Postoperative Complications/prevention & control , Stroke/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Humans , Intracranial Embolism/etiology , Stroke/etiology , Treatment OutcomeABSTRACT
The HERV-W family of human endogenous retroviruses represents a group of numerous sequences that show close similarity in genetic composition. It has been documented that some members of HERV-W-derived expression products are supposed to play significant role in humans' pathology, such as multiple sclerosis or schizophrenia. Other members of the family are necessary to orchestrate physiological processes (eg, ERVWE1 coding syncytin-1 that is engaged in syncytiotrophoblast formation). Therefore, an assay that would allow the recognition of particular form of HERV-W members is highly desirable. A peptide nucleic acid (PNA)-mediated technique for the discrimination between multiple sclerosis-associated retrovirus and ERVWE1 sequence has been developed. The assay uses a PNA probe that, being fully complementary to the ERVWE1 but not to multiple sclerosis-associated retrovirus (MSRV) template, shows high selective potential. Single-stranded DNA binding protein facilitates the PNA-mediated, sequence-specific formation of strand invasion complex and, consequently, local DNA unwinding. The target DNA may be then excluded from further analysis in any downstream process such as single-stranded DNA-specific exonuclease action. Finally, the reaction conditions have been optimized, and several PNA probes that are targeted toward distinct loci along whole HERV-W env sequences have been evaluated. We believe that PNA/single-stranded DNA binding protein-based application has the potential to selectively discriminate particular HERV-W molecules as they are at least suspected to play pathogenic role in a broad range of medical conditions, from psycho-neurologic disorders (multiple sclerosis and schizophrenia) and cancers (breast cancer) to that of an auto-immunologic background (psoriasis and lupus erythematosus).
Subject(s)
DNA, Single-Stranded/metabolism , DNA-Binding Proteins/metabolism , Endogenous Retroviruses/genetics , Peptide Nucleic Acids/metabolism , DNA, Single-Stranded/chemistry , DNA-Binding Proteins/chemistry , Humans , Models, Molecular , Multiple Sclerosis/virology , Peptide Nucleic Acids/chemistry , RNA, Viral/metabolismABSTRACT
BACKGROUND: It is generally believed that there are many natural sources of as yet unknown bioactive compounds with a high biotechnological potential. However, the common method based on the use of cell extracts in the preliminary screening for particular molecules or activities is problematic as amounts of obtained compounds may be low, and such experiments are hardly reproducible. Therefore, the aim of this work was to test whether a novel strategy to search for previously unknown biological activities can be efficient. This strategy is based on construction of metagenomic libraries and employment of Escherichia coli strains as cell factories producing compounds of properties potentially useful in biotechnology. RESULTS: Three cyanobacterial metagenomic libraries were constructed in the fosmid system. The libraries were screened for various biological activities. Extracts from selected E. coli clones bearing constructs with fragments of cyanobacterial genomes revealed antimicrobial or anticancer activities. Interestingly, stimulation of growth of host bacteria bearing particular plasmids with certain cyanobacterial genes was detected, suggesting a potential possibility for improvement of E. coli cultivation during biotechnological production. The most interesting plasmids were sequenced, and putative mechanisms of biological effects caused by cyanobacterial gene products are discussed. CONCLUSIONS: The strategy of exploring cyanobacteria as sources of bioactive compounds, based on E. coli cell factories producing compounds due to expression of genes from metagenomic libraries, appears to be effective.
Subject(s)
Cyanobacteria/genetics , Escherichia coli/genetics , Gene Library , Genetic Vectors , Metagenome , MetagenomicsABSTRACT
Introduction: Aortic stenosis is the most common primary valve disease and requires invasive treatment. Transcatheter aortic valve implantation (TAVI) from a transfemoral access is a routine intervention worldwide. Aim: To investigate the correlation between external iliac artery diameter (EIAD) indexed to body surface area (BSA) (EIAD-BSA) and access site complications in patients undergoing TAVI via transfemoral access (TF) (TF-TAVI). Material and methods: Patients underwent TF-TAVI in 2017-2019 at the Upper-Silesian Medical Center in Katowice. Based on the preoperative multi-slice computed tomography (MSCT), pre-specified measurements of the ilio-femoral vessels were performed. The results were indexed to BSA and body mass index (BMI). Complications after TAVI were defined by Valve Academic Research Consortium 3 (VARC-3). The primary outcome regarding the adverse events after TAVI was the composite of access site complications requiring surgical intervention or blood transfusion. Results: The registry included 193 unselected patients with severe symptomatic aortic stenosis. Vascular and access-related complications including bleeding occurred in 17.1% of patients. Major TAVI access site complications (VARC-3) were reported in 5.7% of patients, while minor complications (VARC-3) occurred in 2.6%. EIAD-BSA demonstrated a positive correlation with the access site complications primary endpoint. Patients with greater EIAD-BSA had a numerically higher number of access site adverse events requiring surgical intervention or blood transfusion: n = 12 (5%) vs. n = 4 (4%), p = 0.011. Conclusions: External iliac artery diameter indexed to BSA could be an underestimated indicator of unfavorable outcomes after TF-TAVI, predicting periprocedural access site complications.
ABSTRACT
AIMS: The relationship between accelerometry data and changes in Kansas City Cardiomyopathy Questionnaire-Physical Limitation Score (KCCQ-PLS) or 6 min walk test (6MWT) is not well understood. METHODS AND RESULTS: VITALITY-HFpEF accelerometry substudy (n = 69) data were assessed at baseline and 24 weeks. Ordinal logistic regression models were used to assess the association between accelerometry activity and deterioration, improved, or unchanged KCCQ-PLS (≥8.33 and ≤ -4.17 points) and 6MWT (≥32 vs. ≤ -32 m). KCCQ-PLS score deteriorated in 16 patients, improved in 34, and was unchanged in 19. 6MWT deteriorated in 8 patients, improved in 21, and was unchanged in 19. Mean accelerometer wear was 21.4 (±2.1) h/day. Changes in hours active from baseline to 24 weeks were not significantly different among patients who exhibited deterioration, improvement, or no change in KCCQ-PLS [odds ratio (OR) 0.91, 95% confidence interval (CI) 0.71-1.18; P = 0.48] or 6MWT (OR 1.21, 95% CI 0.91-1.60; P = 0.18). Similar lack of association was observed for other accelerometry metrics and change in KCCQ and 6MWT. These findings were unaffected when KCCQ and 6MWT were examined as continuous variables. CONCLUSIONS: Accelerometer-based activity measures did not correlate with subjective or objective standard measures of health status and functional capacity in heart failure with preserved ejection fraction. Further investigation of their relationships to clinical outcomes is required.
Subject(s)
Heart Failure , Humans , Accelerometry , Health Status , Quality of Life , Stroke VolumeABSTRACT
Background: Oncological treatment of breast cancer may be associated with adverse effects on myocardial function. Objectives: The objective of this study was to compare the influence of three oncological treatment methods of intervention on the echocardiographic (ECHO) parameters of left ventricular function. Materials and Methods: One hundred and fifty-five women with breast cancer were divided into three groups depending on the type of therapy used: group I (AC)-anthracyclines; group II (AC + TZ)-anthracyclines + trastuzumab; and group III (RTls+)-anthracyclines with or without trastuzumab + left-sided radiotherapy. Prospective ECHO examinations were performed at baseline and every 3 months, up to 12 months from the start of the therapy. Patients with a history of chemotherapy or who were diagnosed with heart disease were not included in the study. Results: Out of 155 patients, 3 died due to cancer as the primary cause, and 12 withdrew their consent for further observation. Baseline systolic and diastolic ECHO parameters did not differ between the analyzed groups. Cardiotoxicity, according to the LVEF criteria, occurred during follow-up in 20 patients (14.3%), irrespective of the treatment method used. Diastolic echocardiographic parameters did not change significantly after 12 months in each group, except for the left atrial volume index (LAVi), which was significantly higher in the AC + TZ compared to the values in the RTls+ group. Conclusions: All three oncologic therapeutic modalities in women with breast cancer showed no significant differences in relation to the incidence of echocardiographic cardiotoxicity criterion; however, transient systolic decrease in LVEF was most frequently observed in the AC + TZ therapeutic regimen. Left-sided radiotherapy was not associated with excess left ventricular systolic and diastolic dysfunction during a 12-month follow-up period. The predictors of negative changes in diastolic parameters included age and combined anthracycline and trastuzumab therapy.
ABSTRACT
BACKGROUND: Empagliflozin reduces the risk of heart failure (HF) hospitalizations but not all-cause mortality when started within 14 days of acute myocardial infarction (AMI). OBJECTIVES: This study sought to evaluate the association of left ventricular ejection fraction (LVEF), congestion, or both, with outcomes and the impact of empagliflozin in reducing HF risk post-AMI. METHODS: In the EMPACT-MI (Trial to Evaluate the Effect of Empagliflozin on Hospitalization for Heart Failure and Mortality in Patients with Acute Myocardial Infarction) trial, patients were randomized within 14 days of an AMI complicated by either newly reduced LVEF<45%, congestion, or both, to empagliflozin (10 mg daily) or placebo and were followed up for a median of 17.9 months. RESULTS: Among 6,522 patients, the mean baseline LVEF was 41 ± 9%; 2,648 patients (40.6%) presented with LVEF <45% alone, 1,483 (22.7%) presented with congestion alone, and 2,181 (33.4%) presented with both. Among patients in the placebo arm of the trial, multivariable adjusted risk for each 10-point reduction in LVEF included all-cause death or HF hospitalization (HR: 1.49; 95% CI: 1.31-1.69; P < 0.0001), first HF hospitalization (HR: 1.64; 95% CI: 1.37-1.96; P < 0.0001), and total HF hospitalizations (rate ratio [RR]: 1.89; 95% CI: 1.51-2.36; P < 0.0001). The presence of congestion was also associated with a significantly higher risk for each of these outcomes (HR: 1.52, 1.94, and RR: 2.03, respectively). Empagliflozin reduced the risk for first (HR: 0.77; 95% CI: 0.60-0.98) and total (RR: 0.67; 95% CI: 0.50-0.89) HF hospitalizations, irrespective of LVEF or congestion, or both. The safety profile of empagliflozin was consistent across baseline LVEF and irrespective of congestion status. CONCLUSIONS: In patients with AMI, the severity of left ventricular dysfunction and the presence of congestion was associated with worse outcomes. Empagliflozin reduced first and total HF hospitalizations across the range of LVEF with and without congestion. (Trial to Evaluate the Effect of Empagliflozin on Hospitalization for Heart Failure and Mortality in Patients with Acute Myocardial Infarction [EMPACT-MI]; NCT04509674).
Subject(s)
Benzhydryl Compounds , Glucosides , Heart Failure , Myocardial Infarction , Sodium-Glucose Transporter 2 Inhibitors , Ventricular Function, Left , Humans , Benzhydryl Compounds/therapeutic use , Glucosides/therapeutic use , Male , Female , Myocardial Infarction/drug therapy , Myocardial Infarction/epidemiology , Heart Failure/drug therapy , Heart Failure/mortality , Middle Aged , Aged , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Ventricular Function, Left/drug effects , Stroke Volume/drug effects , Hospitalization/statistics & numerical data , Double-Blind Method , Follow-Up StudiesABSTRACT
BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) is a viable alternative to redo surgery in selected patients with bioprosthetic valve dysfunction. Most ViV-TAVI procedures have been performed in stented bioprosthetic valves (ST); stentless bioprostheses (SL) lack fluoroscopic markers and could be more challenging for ViV-TAVI. Data on more recent patients applying Valve Academic Research Consortium (VARC)-3 defined outcomes are scarce. We compared patient characteristics, procedural outcomes, and 5-year mortality of patients with SL versus ST aortic bioprosthetic valve failure undergoing ViV-TAVI. METHODS: Patients undergoing ViV-TAVI between 2007 and 2022 (52.5% of cases after 2015) at 3 German centers were included in this analysis. The co-primary outcome measures were technical success, device success, and early safety defined by VARC-3. Mortality was assessed up to 5 years. RESULTS: Overall, 43 (11.8%) SL and 313 (88.2%) ST ViV-TAVI were included. Patients were comparable with regard to age, sex, clinically relevant baseline comorbidities, and surgical risk. Technical success (SL: 83.7% versus ST: 79.9%, p = 0.552), device success (SL: 67.4% versus ST: 54.3%, p = 0.105), and early safety (SL: 74.4% versus ST: 66.5%, p = 0.296) were comparable between groups. The 30-day mortality (SL: 7.0% versus ST: 2.6%, p = 0.136) and 5-year mortality rates (SL: 23.3% versus ST: 24.6%, p = 0.874) were not significantly different between groups. CONCLUSION: SL and ST ViV-TAVI led to comparable short-term outcomes according to VARC-3- defined endpoints and similar mortality rates up to 5 years of follow-up. VARC-3 defined technical success, device success, and early safety as well as 5-year all-cause mortality in patients undergoing valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) into stentless (SL) compared with stented (ST) failed aortic bioprostheses.
ABSTRACT
BACKGROUND: The two most common organisms found in infective endocarditis following transcatheter aortic valve implantation (TAVI-IE) are enterococci (EC-IE) and staphylococci (SC-IE). We aimed to compare clinical characteristics and outcomes of patients with EC-IE and SC-IE. METHODS: TAVI-IE patients from 2007 to 2021 were included in this analysis. The 1-year mortality was the primary outcome measure of this retrospective multi-center analysis. RESULTS: Out of 163 patients, 53 (32.5%) EC-IE and 69 (42.3%) SC-IE patients were included. Subjects were comparable with regard to age, sex, and clinically relevant baseline comorbidities. Symptoms at admission were not significantly different between groups, except for a lower risk for presenting with septic shock in EC-IE than SC-IE. Treatment was performed in 78% by antibiotics alone and in 22% of patients by surgery and antibiotics, with no significant differences between groups. The rate of any complication, in particular heart failure, renal failure, and septic shock during treatment for IE, was lower in EC-IE compared with SC-IE (p < 0.05). In-hospital (EC-IE: 36% vs. SC-IE: 56%, p = 0.035) and 1-year mortality (EC-IE: 51% vs. SC-IE: 70%, p = 0.009) were significantly lower in EC-IE compared with SC-IE. CONCLUSIONS: EC-IE, compared with SC-IE, was associated with a lower morbidity and mortality. However, absolute numbers are high, a finding that should trigger further research in appropriate perioperative antibiotic management and improvement of early IE diagnosis in the case of clinical suspicion.
ABSTRACT
INTRODUCTION: Transcatheter aortic valve-in-valve implantation (TAVI-ViV) can be associated with unfavorable hemodynamic outcomes. This study aimed to estimate the prevalence, identify the risk factors, and evaluate the outcomes and survival of patients with high residual gradients after TAVI-ViV. METHODS: A total of 85 patients were included in the study. The cohort was divided into group A, with postprocedural mean pressure gradient (PG) ≥ 20 mmHg, and group B, with mean PG < 20 mmHg. RESULTS: Postprocedural PG ≥ 20 mmHg was observed in 24.7% of the patients. In a univariate analysis, preoperative gradient, pre-existing patient-prosthesis mismatch (PPM), deep valve implantation, small degenerated valves, and an older generation of transcatheter aortic valves were found to be risk factors for high residual gradient. Multivariate analysis showed that preexisting maxPG > 60 mmHg, implantation level of 4 mm below neo-annulus, and degenerated valve size ≤ 23 mm were independent predictors of high residual gradient. There were no differences in early morbidity (myocardial infarction, pacemaker implantation, stroke, acute renal insufficiency) between groups. Kaplan-Meier estimated that the survival rate was comparable at one and five years regardless of postoperative gradient. Survivors with high residual mean gradient were significantly affected by a high New York Heart Association (NYHA) class. CONCLUSION: High residual transvalvular gradient after TAVI-ViV is not rare, but it does not significantly affect mortality. High residual mean gradient has a negative impact on NYHA functional class improvement after the procedure. High preoperative gradient, implantation level, and small failed bioprosthesis may predispose to increased residual gradient.
Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Heart Valve Prosthesis/adverse effects , Aortic Valve Stenosis/surgery , Prosthesis Failure , Prosthesis Design , Treatment Outcome , Bioprosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Heart Valve Prosthesis Implantation/methods , Risk Factors , Factor Analysis, StatisticalABSTRACT
BACKGROUND: Staphylococcus aureus (SA) has been extensively studied as causative microorganism of surgical prosthetic-valve infective endocarditis (IE). However, scarce evidence exists on SA IE after transcatheter aortic valve replacement (TAVR). METHODS: Data were obtained from the Infectious Endocarditis After TAVR International Registry, including patients with definite IE after TAVR from 59 centres in 11 countries. Patients were divided into 2 groups according to microbiologic etiology: non-SA IE vs SA IE. RESULTS: SA IE was identified in 141 patients out of 573 (24.6%), methicillin-sensitive SA in most cases (115/141, 81.6%). Self-expanding valves were more common than balloon-expandable valves in patients presenting with early SA IE. Major bleeding and sepsis complicating TAVR, neurologic symptoms or systemic embolism at admission, and IE with cardiac device involvement (other than the TAVR prosthesis) were associated with SA IE (P < 0.05 for all). Among patients with IE after TAVR, the likelihood of SA IE increased from 19% in the absence of those risk factors to 84.6% if ≥ 3 risk factors were present. In-hospital (47.8% vs 26.9%; P < 0.001) and 2-year (71.5% vs 49.6%; P < 0.001) mortality rates were higher among patients with SA IE vs non-SA IE. Surgery at the time of index SA IE episode was associated with lower mortality at follow-up compared with medical therapy alone (adjusted hazard ratio 0.46, 95% CI 0.22-0.96; P = 0.038). CONCLUSIONS: SA IE represented approximately 25% of IE cases after TAVR and was associated with very high in-hospital and late mortality. The presence of some features determined a higher likelihood of SA IE and could help to orientate early antibiotic regimen selection. Surgery at index SA IE was associated with improved outcomes, and its role should be evaluated in future studies.
Subject(s)
Endocarditis, Bacterial/epidemiology , Heart Valve Prosthesis/adverse effects , Prosthesis-Related Infections/epidemiology , Registries , Staphylococcal Infections/epidemiology , Staphylococcus aureus/isolation & purification , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Endocarditis, Bacterial/microbiology , Female , Follow-Up Studies , Global Health , Heart Valve Prosthesis/microbiology , Hospital Mortality/trends , Humans , Incidence , Male , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/microbiology , Retrospective Studies , Risk Factors , Staphylococcal Infections/diagnosis , Staphylococcal Infections/microbiology , Survival Rate/trends , Transcatheter Aortic Valve Replacement/adverse effectsABSTRACT
BACKGROUND: The optimal treatment of patients developing infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is uncertain. OBJECTIVES: The goal of this study was to investigate the clinical characteristics and outcomes of patients with TAVI-IE treated with cardiac surgery and antibiotics (IE-CS) compared with patients treated with antibiotics alone (IE-AB). METHODS: Crude and inverse probability of treatment weighting analyses were applied for the treatment effect of cardiac surgery vs medical therapy on 1-year all-cause mortality in patients with definite TAVI-IE. The study used data from the Infectious Endocarditis after TAVI International Registry. RESULTS: Among 584 patients, 111 patients (19%) were treated with IE-CS and 473 patients (81%) with IE-AB. Compared with IE-AB, IE-CS was not associated with a lower in-hospital mortality (HRunadj: 0.85; 95% CI: 0.58-1.25) and 1-year all-cause mortality (HRunadj: 0.88; 95% CI: 0.64-1.22) in the crude cohort. After adjusting for selection and immortal time bias, IE-CS compared with IE-AB was also not associated with lower mortality rates for in-hospital mortality (HRadj: 0.92; 95% CI: 0.80-1.05) and 1-year all-cause mortality (HRadj: 0.95; 95% CI: 0.84-1.07). Results remained similar when patients with and without TAVI prosthesis involvement were analyzed separately. Predictors for in-hospital and 1-year all-cause mortality included logistic EuroSCORE I, Staphylococcus aureus, acute renal failure, persistent bacteremia, and septic shock. CONCLUSIONS: In this registry, the majority of patients with TAVI-IE were treated with antibiotics alone. Cardiac surgery was not associated with an improved all-cause in-hospital or 1-year mortality. The high mortality of patients with TAVI-IE was strongly linked to patients' characteristics, pathogen, and IE-related complications.
Subject(s)
Endocarditis, Bacterial/drug therapy , Endocarditis, Bacterial/surgery , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/surgery , Staphylococcal Infections/drug therapy , Staphylococcal Infections/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Anti-Bacterial Agents/therapeutic use , Cardiac Surgical Procedures , Combined Modality Therapy , Endocarditis, Bacterial/etiology , Female , Humans , Male , Prosthesis-Related Infections/etiology , Staphylococcal Infections/etiology , Transcatheter Aortic Valve Replacement/adverse effectsABSTRACT
BACKGROUND: The relationship between preoperative cardiac conduction abnormalities (CCA) and long-term outcomes after transcatheter aortic valve-in-valve implantation (TAVI-VIV) remains unclear. The aim of the study was to evaluate the effects of preoperative CCA on mortality and morbidity after TAVI-VIV and to estimate the impact of new-onset CCA on postoperative outcomes. METHODS: Between 2011 and 2020, 201 patients with degenerated aortic bioprostheses were qualified for TAVI-VIV procedures in two German heart centers. Cases with previously implanted permanent rhythm-controlling devices were excluded (n = 53). A total of 148 subjects met the eligibility criteria and were divided into 2 study groups according to the presence of preexisting CCA (CCA (n = 84) and non-CCA (n = 64), respectively). Early and late mortality and morbidity were evaluated. Follow-up functional status was assessed according to New York Heart Association (NYHA) classification. RESULTS: There were no procedural deaths. TAVI-VIV related new-onset CCAs were observed in 35.8% patients. The 30-day permanent pacemaker implantation rate was 1.6% in non-CCA vs 9.5% in CCA group (p = 0.045). Preexisting right bundle-branch block (OR:5.01; 95%CI, 1.05-23.84) and first-degree atrioventricular block (OR:4.55; 95%CI, 1.10-18.73) were independent predictors of new pacemaker implantation. One-year and five-year probability of survival were comparable in CCA and non-CCA groups: 90.3% vs 91.8% and 68.2% vs 74.3%, respectively. Surviving patients with preexisting and new-onset CCA had a worse functional status according to NYHA classification at follow-up. CONCLUSION: Preexisting and new-onset postoperative CCAs did not affect early and late mortality after TAVI-VIV procedures, however, they may have a negative impact on late functional status.
Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment OutcomeABSTRACT
BACKGROUND: Stroke is one of the most common and potentially disabling complications of infective endocarditis (IE). However, scarce data exist about stroke complicating IE after transcatheter aortic valve replacement (TAVR). OBJECTIVES: The purpose of this study was to determine the incidence, risk factors, clinical characteristics, management, and outcomes of patients with definite IE after TAVR complicated by stroke during index IE hospitalization. METHODS: Data from the Infectious Endocarditis after TAVR International Registry (including 569 patients who developed definite IE following TAVR from 59 centers in 11 countries) was analyzed. Patients were divided into two groups according to stroke occurrence during IE admission (stroke [S-IE] vs. no stroke [NS-IE]). RESULTS: A total of 57 (10%) patients had a stroke during IE hospitalization, with no differences in causative microorganism between groups. S-IE patients exhibited higher rates of acute renal failure, systemic embolization, and persistent bacteremia (p < 0.05 for all). Previous stroke before IE, residual aortic regurgitation ≥moderate after TAVR, balloon-expandable valves, IE within 30 days after TAVR, and vegetation size >8 mm were associated with a higher risk of stroke during the index IE hospitalization (p < 0.05 for all). Stroke rate in patients with no risk factors was 3.1% and increased up to 60% in the presence of >3 risk factors. S-IE patients had higher rates of in-hospital mortality (54.4% vs. 28.7%; p < 0.001) and overall mortality at 1 year (66.3% vs. 45.6%; p < 0.001). Surgical treatment was not associated with improved outcomes in S-IE patients (in-hospital mortality: 46.2% in surgical vs. 58.1% in no surgical treatment; p = 0.47). CONCLUSIONS: Stroke occurred in 1 of 10 patients with IE post-TAVR. A history of stroke, short time between TAVR and IE, vegetation size, valve prosthesis type, and residual aortic regurgitation determined an increased risk. The occurrence of stroke was associated with increased in-hospital and 1-year mortality rates, and surgical treatment failed to improve clinical outcomes.
Subject(s)
Endocarditis, Bacterial/complications , Postoperative Complications , Stroke/etiology , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Incidence , Male , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Postoperative Complications/therapy , Retrospective Studies , Risk Factors , Stroke/diagnosis , Stroke/epidemiology , Stroke/therapyABSTRACT
Mitral regurgitation (MR) is a frequent valvular disease among patients deemed too high risk for surgery. Echocardiography along with CT is the primary diagnostic tool for MR and offers a comprehensive 3D assessment in patient selection and screening for the optimal treatment method. The direct percutaneous mitral annuloplasty addresses the underlying mechanisms of functional MR with a less invasive, catheter-based approach. The here-described techniques proved a sufficient safety profile, delivered significant MR reduction in most of the cases, and were associated with a notable improvement of symptoms. Although long-term outcome assessment is needed to support these early reports, the percutaneous mitral annuloplasty is likely to set a new standard of treatment in the forthcoming future.
ABSTRACT
BACKGROUND: The ACURATE neo prosthesis is commonly implanted using introducer sheaths with inner diameters of up to 20 French. The use of only the expandable mesh component of the transGlide introducer system (Meshonly) would substantially decrease the inner diameter to 13 French. We sought to assess the feasibility and safety of using Meshonly for femoral access of the ACURATE neo device and to compare outcomes with patients in whom standard sheaths were used. METHODS AND RESULTS: We retrospectively analyzed a total of 551 patients with severe aortic stenosis from 4 high volume centers in Germany and Switzerland undergoing transfemoral TAVI between February 2016 and February 2018 with implantation of the ACURATE neo device. The median age was 81.7 [78.3-85.2], 67.0% were female, the STS score was 4.2% [2.8-6.5]. The use of the Meshonly was feasible in all attempted cases (nâ¯=â¯272); in all other patients, a standard sheath was used. Major vascular complications at the main access-site (VARC-2) were less frequent in the Meshonly group than in the standard sheath group (1.5% vs. 7.9%; pâ¯<â¯0.001). In the multivariable analysis, the use of Meshonly was independently associated with less major vascular complications (odds ratio 0.10 [95% CI 0.02-0.48]; pâ¯=â¯0.004). CONCLUSIONS: Transfemoral implantation of the ACURATE neo device using the Meshonly was associated with a lower rate of major access-related complications when compared to the standard of care.