Inorg Chem ; 63(1): 689-705, 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38146716

ABSTRACT

Biomolecules play a vital role in the regulation of biomineralization. However, the characteristics of practical nucleation domains are still sketchy. Herein, the effects of the representative biomolecular sequence and conformations on calcium phosphate (Ca-P) nucleation and mineralization are investigated. The results of computer simulations and experiments prove that the line in the arrangement of dual acidic/essential amino acids with a single interval (Bc (Basic) -N (Neutral) -Bc-N-Ac (Acidic)- NN-Ac-N) is most conducive to the nucleation. 2α-helix conformation can best induce Ca-P ion cluster formation and nucleation. "Ac- × × × -Bc" sequences with α-helix are found to be the features of efficient nucleation domains, in which process, molecular recognition plays a non-negligible role. It further indicates that the sequence determines the potential of nucleation/mineralization of biomolecules, and conformation determines the ability of that during functional execution. The findings will guide the synthesis of biomimetic mineralized materials with improved performance for bone repair.


Subject(s)
Biomineralization , Calcium Phosphates , Calcium Phosphates/chemistry , Molecular Conformation
2.
Environ Res ; 251(Pt 1): 118566, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38447606

ABSTRACT

Both g-C3N4 and Bi2O2CO3 are good photocatalysts for the removal of antibiotic pollutants, but their morphological modulation and catalytic performance need to be further improved. In this study, the calcination-hydrothermal method is used to prepare a O-g-C3N4@Bi2O2CO3 (CN@BCO) composite photocatalyst from dicyandiamide and bismuth nitrate. The prepared catalyst is characterized through various methods, including X-ray diffraction (XRD) and transmission electron microscopy (TEM). Further, the effects of different parameters, such as catalyst concentration and initial pH of the reaction solution, on its photocatalytic activity are investigated. The results show that the CN@BCO sample achieves an optimal degradation rate of 98.1% for tetracycline hydrochloride (TCH) with a concentration of 20 mg/L and a removal rate of 69.4% for total organic carbon (TOC) at 40 min. The quenching experiments show that ·O2-, h+, and ·OH participate in the photocatalytic process, with ·O2- being the most dominant active species. The toxicity of the predicted TCH degradation intermediates is analyzed using Toxicity Estimation Software Tool (TEST). Overall, the CN@BCO composite exhibits excellent photocatalytic performance, making it a promising candidate for environmental purification and wastewater treatment.


Subject(s)
Bismuth , Tetracycline , Wastewater , Water Pollutants, Chemical , Tetracycline/chemistry , Water Pollutants, Chemical/chemistry , Water Pollutants, Chemical/analysis , Wastewater/chemistry , Bismuth/chemistry , Catalysis , Anti-Bacterial Agents/chemistry , Nanowires/chemistry , Nitrogen Compounds/chemistry , Nitriles/chemistry , Porosity , Graphite
3.
BMC Med Imaging ; 24(1): 159, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38926711

ABSTRACT

BACKGROUND: To assess the improvement of image quality and diagnostic acceptance of thinner slice iodine maps enabled by deep learning image reconstruction (DLIR) in abdominal dual-energy CT (DECT). METHODS: This study prospectively included 104 participants with 136 lesions. Four series of iodine maps were generated based on portal-venous scans of contrast-enhanced abdominal DECT: 5-mm and 1.25-mm using adaptive statistical iterative reconstruction-V (Asir-V) with 50% blending (AV-50), and 1.25-mm using DLIR with medium (DLIR-M), and high strength (DLIR-H). The iodine concentrations (IC) and their standard deviations of nine anatomical sites were measured, and the corresponding coefficient of variations (CV) were calculated. Noise-power-spectrum (NPS) and edge-rise-slope (ERS) were measured. Five radiologists rated image quality in terms of image noise, contrast, sharpness, texture, and small structure visibility, and evaluated overall diagnostic acceptability of images and lesion conspicuity. RESULTS: The four reconstructions maintained the IC values unchanged in nine anatomical sites (all p > 0.999). Compared to 1.25-mm AV-50, 1.25-mm DLIR-M and DLIR-H significantly reduced CV values (all p < 0.001) and presented lower noise and noise peak (both p < 0.001). Compared to 5-mm AV-50, 1.25-mm images had higher ERS (all p < 0.001). The difference of the peak and average spatial frequency among the four reconstructions was relatively small but statistically significant (both p < 0.001). The 1.25-mm DLIR-M images were rated higher than the 5-mm and 1.25-mm AV-50 images for diagnostic acceptability and lesion conspicuity (all P < 0.001). CONCLUSIONS: DLIR may facilitate the thinner slice thickness iodine maps in abdominal DECT for improvement of image quality, diagnostic acceptability, and lesion conspicuity.


Subject(s)
Contrast Media , Deep Learning , Radiographic Image Interpretation, Computer-Assisted , Radiography, Abdominal , Radiography, Dual-Energy Scanned Projection , Tomography, X-Ray Computed , Humans , Prospective Studies , Female , Male , Middle Aged , Aged , Tomography, X-Ray Computed/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Abdominal/methods , Radiography, Dual-Energy Scanned Projection/methods , Adult , Iodine , Aged, 80 and over
4.
Acta Radiol ; : 2841851241262765, 2024 Jul 21.
Article in English | MEDLINE | ID: mdl-39033390

ABSTRACT

BACKGROUND: The best settings of deep learning image reconstruction (DLIR) algorithm for abdominal low-kiloelectron volt (keV) virtual monoenergetic imaging (VMI) have not been determined. PURPOSE: To determine the optimal settings of the DLIR algorithm for abdominal low-keV VMI. MATERIAL AND METHODS: The portal-venous phase computed tomography (CT) scans of 109 participants with 152 lesions were reconstructed into four image series: VMI at 50 keV using adaptive statistical iterative reconstruction (Asir-V) at 50% blending (AV-50); and VMI at 40 keV using AV-50 and DLIR at medium (DLIR-M) and high strength (DLIR-H). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of nine anatomical sites were calculated. Noise power spectrum (NPS) using homogenous region of liver, and edge rise slope (ERS) at five edges were measured. Five radiologists rated image quality and diagnostic acceptability, and evaluated the lesion conspicuity. RESULTS: The SNR and CNR values, and noise and noise peak in NPS measurements, were significantly lower in DLIR images than AV-50 images in all anatomical sites (all P < 0.001). The ERS values were significantly higher in 40-keV images than 50-keV images at all edges (all P < 0.001). The differences of the peak and average spatial frequency among the four reconstruction algorithms were significant but relatively small. The 40-keV images were rated higher with DLIR-M than DLIR-H for diagnostic acceptance (P < 0.001) and lesion conspicuity (P = 0.010). CONCLUSION: DLIR provides lower noise, higher sharpness, and more natural texture to allow 40 keV to be a new standard for routine VMI reconstruction for the abdomen and DLIR-M gains higher diagnostic acceptance and lesion conspicuity rating than DLIR-H.

5.
J Magn Reson Imaging ; 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38112305

ABSTRACT

BACKGROUND: Quantitative diffusion metrics provide additional microstructural information of diseases. The robustness of quantitative diffusion metrics should be established before clinical application. PURPOSE: To evaluate the variability and reproducibility of quantitative diffusion MRI metrics. STUDY TYPE: Prospective. POPULATION: 14 volunteers (7 men; median age, range, 28, 26-59 years). FIELD STRENGTH/SEQUENCE: 3.0-T/Diffusion spectrum imaging. ASSESSMENT: Brain MRI studies were performed four times per subject: involving different combinations of coil types and voxel sizes. Regions of interest of 13 brain anatomical sites were drawn by one observer twice and another observer once to allow interobserver and intraobserver reproducibility assessment. Twenty-five quantitative metrics were calculated using four diffusion models. STATISTICAL TESTS: The variability was evaluated with coefficients of variation (CV), and quartile coefficient of dispersion (QCD). The reproducibility was assessed with intraclass correlation coefficient (ICC), and concordance correlation coefficient (CCC). Wilcoxon signed rank test was used to compare the influence of factors on robustness of quantitative diffusion metrics. A two-tailed P < 0.05 was considered statistically significant. RESULTS: The variability of quantitative diffusion metrics showed CV of 2.4%-68.2%, and QCD of 0.6%-48.2%, respectively. The reproducibility of scans using 20-channel coils with voxels of 2 × 2 × 2 mm3 and 3 × 3 × 3 mm3 , respectively (ICC 0.03-0.84, CCC 0.03-0.84) was significantly worse than that of repeated scans using a 20-channel coil with a voxel size of 2 × 2 × 2 mm3 (ICC of 0.74-0.97, CCC 0.74-0.97) and that of scans using 20- and 64-channel coils, respectively, with a voxel size of 2 × 2 × 2 mm3 (ICC 0.59-0.95, CCC 0.59-0.95). The intraobserver reproducibility (ICC 0.49-0.94, CCC 0.49-0.94) was significantly better than the interobserver reproducibility (ICC 0.28-0.91, CCC 0.28-0.91). DATA CONCLUSION: Our study indicated that the voxel size has a greater influence on the reproducibility of quantitative diffusion metrics than scan-rescans and coils. The reproducibility within one observer was higher than that between two observers. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.

6.
Curr Cancer Drug Targets ; 24(6): 654-667, 2024.
Article in English | MEDLINE | ID: mdl-38419344

ABSTRACT

BACKGROUND: Lung adenocarcinoma (LUAD) is a major health challenge worldwide with an undesirable prognosis. LINC00982 has been implicated as a tumor suppressor in diverse human cancers; however, its role in LUAD has not been fully characterized. METHODS: Expression level and prognostic value of LINC00982 were investigated in pan-cancer and lung cancer from The Cancer Genome Atlas (TCGA) project. Differential expression analysis based on the LINC00982 expression level was performed in LUAD followed by gene set enrichment analysis (GSEA) and functional enrichment analyses. The association between LINC00982 expression and tumor immune microenvironment characteristics was evaluated. A potential ceRNA regulatory axis was identified and experimentally validated. RESULTS: We found that LINC00982 expression was downregulated and correlated with poor prognosis in LUAD. Enrichment analyses revealed that LINC00982 could inhibit DNA damage repair and cell proliferation, but enhance tumor metabolic reprogramming. We identified a competing endogenous RNA network involving LINC00982, miR-183-5p, and ATP-binding cassette subfamily A member 8 (ABCA8). Luciferase assays confirmed that miR-183-5p can interact with LINC00982 and ABCA8. Forced miR-183-5p expression reduced LINC00982 transcript levels and suppressed ABCA8 expression. CONCLUSIONS: Our findings revealed the LINC00982/miR-183-5p/ABCA8 axis as a potential therapeutic target in LUAD.


Subject(s)
ATP-Binding Cassette Transporters , Adenocarcinoma of Lung , Cell Proliferation , Computational Biology , Gene Expression Regulation, Neoplastic , Lung Neoplasms , MicroRNAs , RNA, Long Noncoding , Humans , MicroRNAs/genetics , RNA, Long Noncoding/genetics , Adenocarcinoma of Lung/genetics , Adenocarcinoma of Lung/pathology , Lung Neoplasms/genetics , Lung Neoplasms/pathology , Lung Neoplasms/metabolism , ATP-Binding Cassette Transporters/genetics , ATP-Binding Cassette Transporters/metabolism , Prognosis , Animals , Mice , Disease Progression , Tumor Microenvironment , Cell Line, Tumor , Mice, Nude
7.
Article in English | MEDLINE | ID: mdl-38666348

ABSTRACT

While hydrometallurgy is the primary technology for recycling spent lithium-ion batteries due to various advantages, it still involves substantial consumption of chemical reagents and poses challenges in wastewater emission. Herein, we report the realization of cathode recycling under lean-leachate conditions by dynamically stabilizing hole-mediated diffusion kinetics, which is enabled by synchronizing the extraction step during the leaching stage, thus continuously removing the dissolved ions out of the leachate. Theoretical molecular dynamics simulations predict that preventing the accumulation of the dissolved ions is efficient for keeping the leaching process proceeding. Experimentally, even with a small dosage of leachate (0.5 mL), a 94.51% leaching efficiency can be achieved (90 °C, 40 min) for spent LNO materials. Considering that our strategy is not limited to a specific materials system, it could be extended to recycle other valuable materials (including LCO or NCM 811) with minimal leachate usage.

8.
Mater Horiz ; 11(9): 2106-2114, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38545857

ABSTRACT

Artificial afferent neurons in the sensory nervous system inspired by biology have enormous potential for efficiently perceiving and processing environmental information. However, the previously reported artificial afferent neurons suffer from two prominent challenges: considerable power consumption and limited scalability efficiency. Herein, addressing these challenges, a bioinspired artificial thermal afferent neuron based on a N-doped SiTe ovonic threshold switching (OTS) device is presented for the first time. The engineered OTS device shows remarkable uniformity and robust endurance, ensuring the reliability and efficacy of the artificial afferent neurons. A substantially decreased leakage current of the SiTe OTS device by nitrogen doping results in ultra-low power consumption less than 0.3 nJ per spike for artificial afferent neurons. The inherent temperature response exhibited by N-doped SiTe OTS materials allows us to construct a highly compact artificial thermal afferent neuron over a wide temperature range. An edge detection task is performed to further verify its thermal perceptual computing function. Our work provides an insight into OTS-based artificial afferent neurons for electronic skin and sensory neurorobotics.


Subject(s)
Neurons, Afferent , Neurons, Afferent/physiology , Temperature , Humans
9.
Environ Pollut ; 359: 124597, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39047890

ABSTRACT

With the prohibition on the production and use of polybrominated diphenyl ethers (PBDEs), decabromodiphenyl ethane (DBDPE) and organophosphate flame retardants (OPFRs) have emerged as their alternatives. However, the vertical transport and associated influencing factors of these chemicals into soil are not clearly understood. To clarify the vertical distribution of the pollutants and related influencing factors, surface soil and soil core samples were collected at a depth in the range of 0.10-5.00 m in a typical 20-year-old flame-retardant production park and surrounding area. PBDEs and DBDPE show a clear point source distribution around the production park with their central concentrations up to 2.88 × 104 and 8.46 × 104 ng/g, respectively. OPFRs are mainly found in residential areas. The production conversion of PBDEs to DBDPE has obvious environmental characteristics. The vertical distribution revealed that most of the pollutants have penetrated into the soil 5.00 m or even deeper. The median concentrations of deca-BDE and DBDPE reached 50.9 and 9.85 × 103 ng/g, respectively, even at a depth of 5.00 m. Soil organic matter plays a crucial role in determining the vertical distribution, while soil clay particles have a greater impact on the high molecular weight and/or highly brominated compounds.

10.
ACS Appl Mater Interfaces ; 16(19): 24748-24759, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38690838

ABSTRACT

In the past decade, perovskite solar cell (PSC) photoelectric conversion efficiency has advanced significantly, and tin dioxide (SnO2) has been extensively used as the electron transport layer (ETL). Due to its high electron mobility, strong chemical stability, energy level matching with perovskite, and easy low-temperature fabrication, SnO2 is one of the most effective ETL materials. However, the SnO2 material as an ETL has its limitations. For example, SnO2 films prepared by low-temperature spin-coating contain a large number of oxygen vacancies, resulting in energy loss and high open-circuit voltage (VOC) loss. In addition, the crystal quality of perovskites is closely related to the substrate, and the disordered crystal orientation will lead to ion migration, resulting in a large number of uncoordinated Pb2+ defects. Therefore, interface optimization is essential to improve the efficiency and stability of the PSC. In this work, 2-(5-chloro-2-benzotriazolyl)-6-tert-butyl-p-cresol (CBTBC) was introduced for ETL modification. On the one hand, the hydroxyl group of CBTBC forms a Lewis mixture with the Sn atom, which reduces the oxygen vacancy defect and prevents nonradiative recombination. On the other hand, the SnO2/CBTBC interface can effectively improve the crystal orientation of perovskite by influencing the crystallization kinetics of perovskite, and the nitrogen element in CBTBC can effectively passivate the uncoordinated Pb2+ defects at the SnO2/perovskite interface. Finally, the prevailing PCE of PSC (1.68 eV) modified by CBTBC was 20.34% (VOC = 1.214 V, JSC = 20.49 mA/cm2, FF = 82.49%).

11.
Adv Sci (Weinh) ; 11(29): e2401635, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38828658

ABSTRACT

The low mechanical reliability and integration failure are key challenges hindering the commercialization of geometrically flexible batteries. This work proposes that the failure of directly integrating flexible batteries using traditional rigid adhesives is primarily due to the mismatch between the generated stress at the adhesive/substrate interface, and the maximum allowable stress. Accordingly, a stress redistribution adhesive layer (SRAL) strategy is conceived by using elastic adhesive to redistribute the generated stress. The function mechanism of the SRAL strategy is confirmed by theoretical finite element analysis. Experimentally, a polyurethane (PU) type elastic adhesive (with maximum strain of 1425%) is synthesized and used as the SRAL to integrate rigid cells on different flexible substrates to fabricate directly integrated flexible battery with robust output under various harsh environments, such as stretching, twisting, and even bending in water. The SRAL strategy is expected to be generally applicable in various flexible devices that involve the integration of rigid components onto flexible substrates.

12.
Environ Sci Pollut Res Int ; 31(29): 41914-41925, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853229

ABSTRACT

During the process of industrial heating, a large amount of polycyclic aromatic hydrocarbons (PAHs) and their halogenated compounds (Cl/Br-PAHs) can be formed. However, there is still limited understanding of the chemicals from different metal smelting industrial parks. This study evaluated the seasonal variations, composition profiles, and source allocations of the atmospheric particulate-bound PAHs and Cl/Br-PAHs in different metal industrial parks in a typical industrial city in northwest China. The results showed that the main PAHs produced by metal smelting were low molecular weight isomers, and the concentrations of Cl-PAHs were lower compared to Br-PAHs. The main Br-PAHs were 1-Br-Pyr and 4-Br-Pyr, while 9-Cl-Fle, 1-Cl-Pyr, and 6-Cl-BaP were the dominated Cl-PAH isomers. No significant difference was found in the concentrations among the sites, whereas the levels of the target chemicals were higher during cold months compared to warm months. The main source of PAHs was coal combustion and gasoline vehicle emission during metal smelting, and that of Cl/Br-PAHs was also industrial coal burning. In addition to the primary source, the secondary chlorination of parent PAHs was also a significant source of Cl-PAHs in the production of high purity aluminum. This study suggests that Cl-PAHs and Br-PAHs may behave differently in the atmosphere.


Subject(s)
Air Pollutants , Environmental Monitoring , Polycyclic Aromatic Hydrocarbons , Seasons , China , Polycyclic Aromatic Hydrocarbons/analysis , Air Pollutants/analysis , Particulate Matter/analysis , Metals/analysis
13.
Biomimetics (Basel) ; 9(7)2024 Jul 05.
Article in English | MEDLINE | ID: mdl-39056849

ABSTRACT

Currently, titanium and its alloys have emerged as the predominant metallic biomaterials for orthopedic implants. Nonetheless, the relatively high post-operative infection rate (2-5%) exacerbates patient discomfort and imposes significant economic costs on society. Hence, urgent measures are needed to enhance the antibacterial properties of titanium and titanium alloy implants. The titanium dioxide nanotube array (TNTA) is gaining increasing attention due to its topographical and photocatalytic antibacterial properties. Moreover, the pores within TNTA serve as excellent carriers for chemical ion doping and drug loading. The fabrication of TNTA on the surface of titanium and its alloys can be achieved through various methods. Studies have demonstrated that the electrochemical anodization method offers numerous significant advantages, such as simplicity, cost-effectiveness, and controllability. This review presents the development process of the electrochemical anodization method and its applications in synthesizing TNTA. Additionally, this article systematically discusses topographical, chemical, drug delivery, and combined antibacterial strategies. It is widely acknowledged that implants should possess a range of favorable biological characteristics. Clearly, addressing multiple needs with a single antibacterial strategy is challenging. Hence, this review proposes systematic research into combined antibacterial strategies to further mitigate post-operative infection risks and enhance implant success rates in the future.

14.
Insights Imaging ; 15(1): 77, 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38499879

ABSTRACT

OBJECTIVE: To appraise the quality of guidelines on intravenous iodinated contrast media (ICM) use in patients with kidney disease, and to compare the recommendations among them. METHODS: We searched four literature databases, eight guideline libraries, and ten homepages of radiological societies to identify English and Chinese guidelines on intravenous ICM use in patients with kidney disease published between January 2018 and June 2023. The quality of the guidelines was assessed with the Scientific, Transparent, and Applicable Rankings (STAR) tool. RESULTS: Ten guidelines were included, with a median STAR score of 46.0 (range 28.5-61.5). The guidelines performed well in "Recommendations" domain (31/40, 78%), while poor in "Registry" (0/20, 0%) and "Protocol" domains (0/20, 0%). Nine guidelines recommended estimated glomerular filtration rate (eGFR) < 30 mL/min/1.73 m2 as the cutoff for referring patients to discuss the risk-benefit balance of ICM administration. Three guidelines further suggested that patients with an eGFR < 45 mL/min/1.73 m2 and high-risk factors also need referring. Variable recommendations were seen in the acceptable time interval between renal function test and ICM administration, and that between scan and repeated scan. Nine guidelines recommended to use iso-osmolar or low-osmolar ICM, while no consensus has been reached for the dosing of ICM. Nine guidelines supported hydration after ICM use, but their protocols varied. Drugs or blood purification therapy were not recommended as preventative means. CONCLUSION: Guidelines on intravenous ICM use in patients with kidney disease have heterogeneous quality. The scientific societies may consider joint statements on controversial recommendations for variable timing and protocols. CRITICAL RELEVANCE STATEMENT: The heterogeneous quality of guidelines, and their controversial recommendations, leave gaps in workflow timing, dosing, and post-administration hydration protocols of contrast-enhanced CT scans for patients with kidney diseases, calling for more evidence to establish a safer and more practicable workflow. KEY POINTS: • Guidelines concerning iodinated contrast media use in kidney disease patients vary. • Controversy remains in workflow timing, contrast dosing, and post-administration hydration protocols. • Investigations are encouraged to establish a safer iodinated contrast media use workflow.

15.
Adv Sci (Weinh) ; 11(25): e2401345, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38647436

ABSTRACT

The development of semiconducting polymers with good processability in green solvents and competitive electrical performance is essential for realizing sustainable large-scale manufacturing and commercialization of organic electronics. A major obstacle is the processability-performance dichotomy that is dictated by the lack of ideal building blocks with balanced polarity, solubility, electronic structures, and molecular conformation. Herein, through the integration of donor, quinoid and acceptor units, an unprecedented building block, namely TQBT, is introduced for constructing a serial of conjugated polymers. The TQBT, distinct in non-symmetric structure and high dipole moment, imparts enhanced solubility in anisole-a green solvent-to the polymer TQBT-T. Furthermore, PTQBT-T possess a highly rigid and planar backbone owing to the nearly coplanar geometry and quinoidal nature of TQBT, resulting in strong aggregation in solution and localized aggregates in film. Remarkably, PTQBT-T films spuncast from anisole exhibit a hole mobility of 2.30 cm2 V-1 s-1, which is record high for green solvent-processable semiconducting polymers via spin-coating, together with commendable operational and storage stability. The hybrid building block emerges as a pioneering electroactive unit, shedding light on future design strategies in high-performance semiconducting polymers compatible with green processing and marking a significant stride towards ecofriendly organic electronics.

16.
Insights Imaging ; 15(1): 186, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090273

ABSTRACT

OBJECTIVE: To evaluate whether and how the radiological journals present their policies on the use of large language models (LLMs), and identify the journal characteristic variables that are associated with the presence. METHODS: In this meta-research study, we screened Journals from the Radiology, Nuclear Medicine and Medical Imaging Category, 2022 Journal Citation Reports, excluding journals in non-English languages and relevant documents unavailable. We assessed their LLM use policies: (1) whether the policy is present; (2) whether the policy for the authors, the reviewers, and the editors is present; and (3) whether the policy asks the author to report the usage of LLMs, the name of LLMs, the section that used LLMs, the role of LLMs, the verification of LLMs, and the potential influence of LLMs. The association between the presence of policies and journal characteristic variables was evaluated. RESULTS: The LLM use policies were presented in 43.9% (83/189) of journals, and those for the authors, the reviewers, and the editor were presented in 43.4% (82/189), 29.6% (56/189) and 25.9% (49/189) of journals, respectively. Many journals mentioned the aspects of the usage (43.4%, 82/189), the name (34.9%, 66/189), the verification (33.3%, 63/189), and the role (31.7%, 60/189) of LLMs, while the potential influence of LLMs (4.2%, 8/189), and the section that used LLMs (1.6%, 3/189) were seldomly touched. The publisher is related to the presence of LLM use policies (p < 0.001). CONCLUSION: The presence of LLM use policies is suboptimal in radiological journals. A reporting guideline is encouraged to facilitate reporting quality and transparency. CRITICAL RELEVANCE STATEMENT: It may facilitate the quality and transparency of the use of LLMs in scientific writing if a shared complete reporting guideline is developed by stakeholders and then endorsed by journals. KEY POINTS: The policies on LLM use in radiological journals are unexplored. Some of the radiological journals presented policies on LLM use. A shared complete reporting guideline for LLM use is desired.

17.
Arch Osteoporos ; 19(1): 65, 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39043915

ABSTRACT

The impact of milk on bone health in rural preschoolers is under-researched. This study, through a clinical trial and a meta-analysis, finds that milk supplementation enhances forearm and calcaneus bone acquisition in children, supporting the benefits of daily milk consumption. PURPOSE: This study evaluated the impact of dairy supplementation on bone acquisition in children's limbs through a cluster-randomized controlled trial and a meta-analysis. METHODS: The trial involved 315 children (4-6 year) from Northwest China, randomized to receive either 390 ml of milk daily (n = 215) or 20-30 g of bread (n = 100) over 12 months. We primarily assessed bone mineral density (BMD) and content (BMC) changes at the limbs, alongside bone-related biomarkers, measured at baseline, the 6th and 12th months. The meta-analysis aggregated BMD or BMC changes in the forearm/legs/calcaneus from published randomized trials involving children aged 3-18 years supplemented with dairy foods (vs. control group). RESULTS: Of 278 completed the trial, intention-to-treat analysis revealed significant increases in BMD (4.05% and 7.31%) and BMC (4.69% and 7.34%) in the left forearm at the 6th and 12th months in the milk group compared to controls (P < 0.001). The calcaneus showed notable improvements in BMD (2.01%) and BMC (1.87%) at 6 months but not at 12 months. Additionally, milk supplementation was associated with beneficial changes in bone resorption markers, parathyroid hormone (- 12.70%), insulin-like growth factor 1 (6.69%), and the calcium-to-phosphorus ratio (2.22%) (all P < 0.05). The meta-analysis, encompassing 894 children, indicated that dairy supplementation significantly increased BMD (SMD, 0.629; 95%CI: 0.275, 0.983) and BMC (SMD, 0.616; 95%CI: 0.380, 0.851) (P < 0.05) in the arms, but not in the legs (P > 0.05). CONCLUSION: Milk supplementation significantly improves bone health in children's forearms, underscoring its potential as a strategic dietary intervention for bone development. Trial registration NCT05074836.


Subject(s)
Bone Density , Dietary Supplements , Child , Child, Preschool , Female , Humans , Male , Bone Density/drug effects , Bone Development/physiology , Calcaneus/diagnostic imaging , China , Forearm , Milk , Adolescent
SELECTION OF CITATIONS