Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Drug Metab Rev ; 53(4): 592-603, 2021 11.
Article in English | MEDLINE | ID: mdl-33561356

ABSTRACT

In the modern age, the struggle to generate appropriate bio-based materials and nano-scaled colloidal particulates for developed application domains, has already resulted in remarkable attempts in the advancement of regulated size and shape, anisotropy, and characteristics of nanostructures. The bottom-up development strategies of components are among the most important science areas throughout nanotechnology, in which the designed building blocks are often utilized to generate novel structures by random self-assembly. In biomedical applications, Janus nanoparticles (JNPs) are necessary. This is due to their effective stimulus-responsive properties, tunable structure, biocompatibility, containing two surfaces with various hydrophobic characteristics and distinct functional groups. Featuring two parts with differing hydrophobicity has been the most critical aspect of the Janus amphiphilic particles. Development of JNPs has been afforded, using imaging agents (e.g. gold (AU) for photoacoustic imaging processing (PAI), silver for surface-enhanced Raman scattering (SERS), and Fe3O4 and MnO2 to magnetic resonance imaging (MRI)). It is also to be mentioned that a number of other properties become salient - properties such as integration imaging factors into JNPs (like quantum dots, fluorescent dyes), multiple imaging methods for screening and diagnosis application can indeed be accomplished. Janus nanostructures have been promising platforms for bioengineering as therapeutic carriers, drug delivery vehicles, and biosensor equipment; they may also be employed for the transport of bioactive hydrophilic and hydrophobic materials. The main production approaches and major advancement of JNPs in the biomedical sector and cancer therapy will be described in this paper.


Subject(s)
Multifunctional Nanoparticles , Nanoparticles , Neoplasms , Gold/chemistry , Humans , Manganese Compounds/therapeutic use , Neoplasms/drug therapy , Oxides/therapeutic use
2.
Med J Islam Repub Iran ; 34: 100, 2020.
Article in English | MEDLINE | ID: mdl-33315994

ABSTRACT

Background: Positron Emission Mammography (PEM) is an imaging technique which is increasing focuses on imaging the chest instead of imaging the whole body. The aim of this study was to conduct a systematic review of the clinical efficacy and coste-ffectiveness of PEM technology, as compared with PET, as a diagnostic method used for breast cancer patients. Methods: The present study was a Health Technology Assessment (HTA), which was conducted via a systematic review of clinical efficacy and cost-effectiveness of the methods based on domestic evidence. To evaluate the efficacy of the PEM diagnostic method, as compared with PET, we used efficacy indices, including Sensitivity, Specificity, Accuracy, PPV, and NPV. The required data were collected through a meta-analysis of studies published in electronic databases from 1990 to 2016. In addition, direct costs in both methods were estimated and finally, a cost-effectiveness analysis was performed using the results of the study. Also, a one-way sensitivity analysis was performed to examine the effects of parameters' uncertainty in the model. In this study, we used STATA software to integrate the results of studies with similar parameters. Results: A total of 722 cases (N) were obtained from the five final studies. The results of the meta-analysis performed on the collected data showed that the two methods were identical in terms of the Specificity and PPV parameters. However, as to Sensitivity, NPV, and Accuracy parameters, the PEM method was superior to the PET for diagnosis of primary breast cancer. The total cost of using PEM and PET was $1737385.7 and $1940903.5, respectively, and the cost of a one-time scan (cost per unit) using PEM and PET devices was $86.82 and $157.63, respectively. As compared with the PET method, the use of the PEM diagnostic method for diagnosis of breast cancer was cost-effective in terms of all the five studied parameters (it was definitely cost-effective for four parameters and was also considered as cost-effective for another index, since ICER was below the threshold). Conclusion: The results showed that the use of PEM technology for the diagnosis of primary breast cancer is more cost-effective than PET technology; thus, due to the wide range of PET technology in different fields, it is recommended that this method should be used in other areas of priority.

4.
Cancers (Basel) ; 15(3)2023 Jan 25.
Article in English | MEDLINE | ID: mdl-36765697

ABSTRACT

Thyroid carcinoma is the most common cancer of the endocrine system, accounting for 12% of all cancer cases in adolescents in the United States. Radioiodine therapy plays a key role in differentiated thyroid cancer (DTC) treatment. This double-blind, randomized, placebo-controlled clinical trial was aimed at evaluating the effect of probiotics supplementation in reducing the acute side-effects of radioiodine therapy in PTC patients. Fifty-six patients were randomly divided into four groups: one placebo and three intervention groups. The probiotics product used in this study was LactoCare (ZistTakhmir Co., Tehran, Iran), a multi-strain commercially available symbiotic containing 12 strains of probiotic species including Lactobacillus strains, Bifidobacteria strains, and Streptococcus thermophilus, plus Fructo-oligosaccharides as the prebiotic. Group 0 was our placebo group (no probiotics), while the other three groups received probiotics capsules for 2/4 days, starting only 2 days prior to radioiodine therapy, only 4 days after radioiodine therapy or 2 days prior and 4 days after radioiodine therapy. Six patients were withdrawn during the study because of poor compliance or at their own request. The symptoms reported by patients including data about the incidence and duration of each complication were recorded. The probiotics' effectiveness was confirmed for dry mouth and taste loss or change when it was administered prior to the radioiodine treatment. The benefit was not confirmed for other radiation-induced complications such as pain and swelling in the neck, nausea and vomiting, salivary gland swelling, and diarrhea. Further large-scale clinical trials are warranted to improve our knowledge in this quickly evolving field.

5.
Semin Nucl Med ; 52(4): 419-431, 2022 07.
Article in English | MEDLINE | ID: mdl-35031115

ABSTRACT

Nuclear medicine offers several diagnostic scans for the evaluation of congenital and acquired conditions of the kidneys and urinary track in children. Tc-99m-MAG 3 diuretic renal scans are most commonly used in the evaluation and follow up of urinary track dilatations. They provide functional information on the differential renal function and on drainage quality which is allows distinction between obstructed and non-obstructed kidneys and the need for surgical correction vs conservative management in kidneys with impaired drainage. Standardized imaging and processing protocols are essential for correct interpretation and for meaningful comparisons between follow up scans. Different approaches and conceptions led to some contradicting recommendations between SNMMI and EANM guidelines on diuretic renography in children which caused confusion and to the emergence of self-made institutional protocols. In Late 2018 the two societies published joint procedural guidelines on diuretic renography in infants and children which hopefully will end the confusion. Tc-99m DMSA scans provide important information about the function of the renal cortex allowing detection of acute pyelonephritis, renal scars dysplasia and ectopy as well as accurate determination of the differential renal function. They are commonly used in the evaluation of children with urinary tract infections and affect clinical management. A standardized imaging and processing protocol improves the diagnostic accuracy of these studies. SPECT or pinhole images should be a routine part of the imaging protocol. This is one of the recommendations in the new EANM and SNMMI procedural guidelines for renal cortical scintigraphy in children available online on the SNMMI website and is under publication. This article provides an overview on the clinical role of diuretic renography and cortical scintigraphy in children and describes the imaging protocols focusing on the new recommendations in the procedural guidelines.


Subject(s)
Technetium Tc 99m Dimercaptosuccinic Acid , Urology , Child , Diuretics , Humans , Kidney/diagnostic imaging , Kidney/physiology , Radioisotope Renography/methods , Radionuclide Imaging , Radiopharmaceuticals , Tomography, Emission-Computed, Single-Photon
6.
Galen Med J ; 11: e2397, 2022.
Article in English | MEDLINE | ID: mdl-36698694

ABSTRACT

Background: Despite the benefits of radioactive iodine (RAI) therapy as an adjunctive treatment for thyroid cancer, it can be associated with several side effects. The main purpose of this study was to determine the changes in serum alkaline phosphatase (ALP), calcium (Ca), and parathyroid hormone (PTH) at different doses of RAI therapy among patients who were referred to the nuclear medicine department of Namazi Hospital, Shiraz. Materials and Methods: This cross-sectional study was conducted on 60 patients with papillary thyroid cancer who underwent RAI therapy at different doses of 100, 150, and 200 mCi. The ALP, Ca, and PTH levels of patients were measured before and 60 days after RAI therapy. Results: Our study revealed that RAI therapy at all doses significantly increased ALP level in comparison with baseline amounts (P≤0.05). However, changes in PTH and Ca levels were not significant among patients who received different doses of RAI (P˃0.05). Conclusion: RAI therapy could affect important hormones and enzymes such as ALP and PTH. This issue can be considered in diagnostic and therapeutic prescriptions of RAI for the treatment of thyroid cancer.[GMJ.2022;11:e2397].

7.
Galen Med J ; 11: e2337, 2022.
Article in English | MEDLINE | ID: mdl-36698693

ABSTRACT

Neurological complications are considered the leading cause of disability and the second cause of death worldwide. Although the most common neurological disorders affecting a large population are Alzheimer's (AD) and Parkinson's diseases (PD), no definitive treatment has been propounded in the clinic. As in recent years, special attention has been paid to medicinal herbal products as one of the ways to meet the challenges of treating diseases. This review study aimed to introduce the naringin neuroprotective effects as an abundant flavonoid in grapes and citrus fruits on the most common neurological disorders, including AD and PD. For this purpose, the specified keywords were searched in PubMed, Web of Science, Scopus, Embase, and Google Scholar, and the results were entered into the study after a concise overview. The findings show naringin can confront neurological disorders through several mechanisms such as modulating stress response pathways, preventing apoptosis, oxidative stress, and neuroinflammation, excessive chelating amounts of metal ions, thereby improving cognitive impairment and memory loss induced by neurological disorders. However, further studies, particularly on human, are critical for the final confirmation of obtained findings. [GMJ.2022;11:e2337].

8.
Int J Radiat Oncol Biol Phys ; 113(1): 125-134, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35085715

ABSTRACT

PURPOSE: Myocardial perfusion defects after breast radiation therapy (RT) correlate with volume of irradiated left ventricle (LV). We aimed to determine the relationship between myocardial perfusion, LV dosimetry, and grade ≥2 late cardiac events in patients with breast cancer undergoing adjuvant RT. METHODS AND MATERIALS: A randomized study evaluated the benefit of inverse-planned intensity modulated radiation therapy over forward-planned intensity modulated radiation therapy for radiation toxicity in breast cancer. A secondary endpoint was evaluating cardiac perfusion by single-photon emission computed tomography done at baseline, 6 months, 1 year, 2 years, and 5 years post-RT. We used receiver operating curve and regression analysis to identify association between perfusion, radiation dose-volumes, and the risk of late cardiac events. RESULTS: Of 181 patients who received adjuvant RT, 102 were patients with cancer in the left breast (called in this study the left-sided group) and 79 were patients with cancer in the right breast (called in this study the right-sided group). Median follow-up was 127 months (range, 19-160 months). A significant worsening of perfusion defects occurred after RT in the left-sided group, which improved by 1 year. Late cardiac events were found among 16 patients (17.2%) in the left-sided group and 4 patients (5.5%) in the right-sided group. Perfusion changes did not correlate with late cardiac events, but LV dose-volumes correlated with late cardiac events. Maintaining the LV volume receiving 5 Gy and 10 Gy to <42 cc and <38cc, respectively, can reduce the risk of radiation-related late cardiac events at 10 years to <5% over baseline. CONCLUSIONS: RT was associated with short-term perfusion defects that improved within 1 year and was not correlated with late cardiac events. The ventricular volumes receiving 5 Gy and 10 Gy were correlated with late cardiac events.


Subject(s)
Breast Neoplasms , Radiation Injuries , Breast Neoplasms/radiotherapy , Cardiotoxicity , Female , Heart/diagnostic imaging , Humans , Prospective Studies , Radiation Injuries/prevention & control
9.
Dig Dis Sci ; 55(1): 172-5, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19229615

ABSTRACT

BACKGROUND: Early detection of biliary atresia (BA) has a vital role in prevention of liver cirrhosis in these patients. There are some evidences that triangular cord (TC) sign, i.e., triangular structure located cranial to the portal vein bifurcation on ultrasonographic examination, is suggestive of BA in suspected cases. The aim of this study is to evaluate and compare the sensitivity, specificity, and accuracy of TC sign with other methods of diagnosis such as hepatobiliary scan. METHODS: Fifty-eight infants referred to pediatric gastroenterology ward with diagnosis of infantile cholestasis from March 2004 to March 2008 were evaluated to find the cause of cholestasis. Diagnosis was made by means of history, clinical examination, hepatobiliary scan, and liver biopsy. Ultrasonographic examination was focused on presence of TC sign in patients. If the diagnosis was in favor of BA, patient was sent for direct cholangiography as a gold-standard test for confirmation of the diagnosis. The sensitivity, specificity, and accuracy of the tests were compared with golden standard. RESULTS: Among 58 infants with infantile cholestasis, BA was diagnosed and confirmed in 10 infants (17.2%). Hepatobiliary scintigraphy had 80% sensitivity, 72.9% specificity, and 74.1% accuracy. TC sign had 70% sensitivity, 95.8% specificity, and 91.3% accuracy. CONCLUSION: TC sign is more accurate than hepatobiliary scan and has acceptable sensitivity and specificity for diagnosis of BA.


Subject(s)
Biliary Atresia/diagnostic imaging , Portal Vein/diagnostic imaging , Cholangiography , Cholestasis/etiology , Female , Humans , Infant , Male , Radionuclide Imaging , Sensitivity and Specificity , Ultrasonography
10.
Cutis ; 86(2): 77-80, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20919600

ABSTRACT

Porokeratosis is a rare keratinization disorder of the skin characterized by annular plaques with an atrophic center surrounded by a raised keratotic wall that spreads centrifugally. We report a case of porokeratosis of Mibelli with mutilation. A 30-year-old woman presented with atrophic plaques on the index fingers of both hands with a keratotic ridge in some margins of the plaques. There was loss of the distal phalanx of the left index finger. In the right hand, shortening of the right distal phalanx and flexion contracture of the distal interphalangeal joint were noted in the index finger.


Subject(s)
Fingers , Porokeratosis/diagnosis , Adult , Biopsy , Diagnosis, Differential , Female , Humans , Porokeratosis/pathology
11.
Cardiol Res Pract ; 2020: 6527820, 2020.
Article in English | MEDLINE | ID: mdl-32802497

ABSTRACT

Identification of risk factors and their importance in different genders is essential in order to prevent, diagnose, and manage coronary artery disease (CAD) properly. The present study aims to investigate the role of gender in the distribution of different risk factors in ischemic heart disease. This study is a cross-sectional study. More than one thousand (N = 1012) patients referring to the Nuclear Medicine Department in Namazi Hospital, Shiraz, Iran, from March 2017 to March 2018 were studied. The patients' demographic data and their clinical history were collected. The results of the myocardial perfusion scan were recorded and compared between groups. Statistical analysis was implemented by SPSS version 18.0, and P values below 0.05 were considered statistically significant. Out of the 1012 patients participating in this study, 698 (69%) were female and 314 (31%) were male. Ischemic heart disease (IHD) was significantly higher in men compared to women (19.1% versus 14.2%). The higher levels of systolic and diastolic blood pressures, along with older age, were a significant risk factor in women (P < 0.05). Previous myocardial infarction (MI), diabetes mellitus (DM), hypertension (HTN), and hyperlipidemia (HLP) had a strong correlation with IHD in our female population. Regarding the male subjects, previous MI and HLP had a lower correlation with IHD. Based on our logistic regression models, investigation of the simultaneous effects of risk factors on IHD showed that previous MI is the most effective risk factor in females (OR = 3.93) mostly in terms of residual ischemia in the infarcted myocardium. In the male population, on the other hand, HTN was identified as the most effective risk factor for IHD (OR = 2). In conclusion, we found that older age, higher blood pressure, DM, previous MI, HTN, and HLP have a significant association with IHD in the female population, whereas older age, DM, and HTN were significant risk factors for IHD in males. Also, the most effective factor for women was previous MI, while it was HTN for the male population.

12.
Indian J Nucl Med ; 31(3): 172-5, 2016.
Article in English | MEDLINE | ID: mdl-27385884

ABSTRACT

BACKGROUND: Radioiodine therapy is used for the treatment of patients with differentiated thyroid cancer (DTC) who undergo total thyroidectomy. After radioiodine administration, regulations require to quarantine these patients until their retained activity reduces to <33 mCi. Some of the injected radioiodine is excreted by perspiration which helps dose reduction so that performing the activities which stimulate sweating such as exercise may shorten the time of dose reduction. To the best of our knowledge, this is the first study in the literature that has evaluated the impact of specific exercise program on the ambient equivalent dose of (131)I gamma rays. MATERIALS AND METHODS: Patients with DTC without metastasis who had undergone total thyroidectomy and were treated with radioiodine were included in this study. 30 patients were chosen among patients who were able to exercise, did not have renal failure, and did not use diuretics. Patients were divided into two control and intervention groups. Intervention group members walked on treadmills under a specific program, in 3 time intervals. The control group did not have any specific activity. Immediately after each exercise process, both groups took a shower, and their doses were measured by a survey dosimeter. RESULTS: It was revealed that there was a significant difference between mean values before and after each exercise time. The calculated P value which evaluates the overall impact was 0.939 which revealed that there was no significant difference between total ambient equivalent dose reductions of both groups. CONCLUSION: According to the study, it may conclude that sweating is an effective alternative way for radioiodine excretion, and if sweating is accompanied with well-hydrated status they may have synergism effect to shorten quarantine period. This could be an important consideration in patients which over-hydration is intolerable especially those with cardiac, liver, or renal problems.

13.
Medicine (Baltimore) ; 94(34): e1325, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26313771

ABSTRACT

We presented a pediatric case with a history of intermittent melena for 3 years because of angiodyplasia of small intestine. The results of frequent upper gastrointestinal endoscopies and colonoscopies as well as both Tc-red blood cell (RBC) and Meckel's scintigraphies for several times were negative in detection of bleeding site. However, Tc-RBC scintigraphy with single-photon emission computed tomography (SPECT)/computed tomography (CT) after heparin augmentation detected a site of bleeding in the distal ileum which later was confirmed during surgery with final diagnosis of angiodysplasia.It could be stated that heparin provocation of bleeding before Tc-RBC scintigraphy accompanied by fused SPECT/CT images should be kept in mind for management of intestinal bleeding especially in difficult cases.


Subject(s)
Angiodysplasia , Heparin , Ileum , Melena/diagnosis , Tomography, Emission-Computed, Single-Photon/methods , Adolescent , Angiodysplasia/complications , Angiodysplasia/diagnosis , Angiodysplasia/physiopathology , Anticoagulants , Digestive System Surgical Procedures/methods , Female , Humans , Ileum/blood supply , Ileum/pathology , Ileum/surgery , Melena/etiology , Melena/physiopathology , Melena/surgery , Radionuclide Imaging/methods , Tomography, X-Ray Computed/methods , Treatment Outcome
14.
J Med Case Rep ; 1: 173, 2007 Dec 05.
Article in English | MEDLINE | ID: mdl-18053241

ABSTRACT

Whole body bone scan with Technetium-99m MDP (methylene diphosphate) can detect bony lesions due to altered osteoblastic activity.Non-physiologic or increased radiotracer uptake in the bony structures of patients with a history of malignant diseases is usually interpreted as being suspicious of bone metastasis. It is extremely important to properly distinguish false positive sites of Tc-99m MDP localization. We present three patients with the same pattern of Tc-99m MDP abnormality in different locations. These scans were all performed on the same day to evaluate possible bone metastases in three patients with breast carcinoma. After careful examination, repeated images revealed bed clothing contamination. This is different from bed contamination by displacement among different patients. It is also different from detector contamination by limited area of involvement where detector contamination appears as a line throughout the total body projection. It can be helpful if a nuclear medicine specialist has a brief look at all scans prior to reporting them. In cases where the same pattern of abnormality is repeated in all images, the possibility of technical error such as bed clothing contamination rather than a pathological abnormality should be borne in mind.

SELECTION OF CITATIONS
SEARCH DETAIL