1.
J Endovasc Ther ; 30(5): 756-768, 2023 10.
Article in English | MEDLINE | ID: mdl-35588222

ABSTRACT

PURPOSE: Displacement forces (DFs) identify hostile landing zones for stent graft deployment in thoracic endovascular aortic repair (TEVAR). However, their use in TEVAR planning is hampered by the need for time-expensive computational fluid dynamics (CFD). We propose a novel fast-approximate computation of DFs merely exploiting aortic arch anatomy, as derived from the computed tomography (CT) and a measure of central aortic pressure. MATERIALS AND METHODS: We tested the fast-approximate approach against CFD gold-standard in 34 subjects with the "bovine" aortic arch variant. For each dataset, a 3-dimensional (3D) model of the aortic arch lumen was reconstructed from computed tomography angiography and CFD then employed to compute DFs within the aortic proximal landing zones. To quantify fast-approximate DFs, the wall shear stress contribution to the DF was neglected and blood pressure space-distribution was averaged on the entire aortic wall to reliably approximate the patient-specific central blood pressure. Also, DF values were normalized on the corresponding proximal landing zone area to obtain the equivalent surface traction (EST). RESULTS: Fast-approximate approach consistently reflected (r2=0.99, p<0.0001) the DF pattern obtained by CFD, with a -1.1% and 0.7° bias in DFs magnitude and orientation, respectively. The normalized EST progressively increased (p<0.0001) from zone 0 to zone 3 regardless of the type of arch, with proximal landing zone 3 showing significantly greater forces than zone 2 (p<0.0001). Upon DF normalization to the corresponding aortic surface, fast-approximate EST was decoupled in blood pressure and a dimensionless shape vector (S) reflecting aortic arch morphology. S showed a zone-specific pattern of orientation and proved a valid biomechanical blueprint of DF impact on the thoracic aortic wall. CONCLUSION: Requiring only a few seconds and quantifying clinically relevant biomechanical parameters of proximal landing zones for arch TEVAR, our method suits the real preoperative decision-making process. It paves the way toward analyzing large population of patients and hence to define threshold values for a future patient-specific preoperative TEVAR planning.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Treatment Outcome , Stents
2.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Article in English | MEDLINE | ID: mdl-36257545

ABSTRACT

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pacemaker, Artificial , Sutureless Surgical Procedures , Humans , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Research Report , Treatment Outcome , Prosthesis Design , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Sutureless Surgical Procedures/adverse effects
3.
Surg Technol Int ; 422023 07 19.
Article in English | MEDLINE | ID: mdl-37470175

ABSTRACT

Since its first implementation, minimally invasive cardiac surgery has become more and more popular among surgeons. By avoiding a complete opening of the sternum, this surgery is traditionally associated with a faster recovery, less surgical pain and less postoperative bleeding and transfusions. With its growing popularity, the need for specifically designed surgical instrumentation is evident. Since 2008, the detachable-branch Glauber clamp (Cardiovision-Trytech, Tokyo, Japan) has been used to facilitate aortic cross-clamp during minimally invasive cardiac surgery, to optimize the intraoperative visualization field without the need for adjunctive incisions of the thorax. It has been specifically developed for limited single-access minimally invasive valve surgery. The clamp is introduced through the main access incision (mini-sternotomy or mini thoracotomy) by means of a specifically designed delivery system, which is subsequently removed, leaving inside the thorax only the detachable closed branches on the aorta. Since its first implementation, the clamp has been used in numerous patients at several cardiac surgery centers worldwide. Over the years, attempts have been made to improve its ergonomics and enhance its performance. The G2 detachable-branch Glauber clamp (USB Medical, Hatboro, PA, USA) occupies a smaller space inside the thorax, has a simplified gripping mechanism and comes with detachable arms that enhance versatility with up to 10 possible clamp configurations. This article describes the characteristics of detachable-branch aortic clamps and compares them to other aortic cross-clamps that are currently available for minimally invasive cardiac surgery.

4.
J Card Surg ; 37(1): 70-75, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34669217

ABSTRACT

OBJECTIVES: As aortic valve repair (AVr) for aortic insufficiency (AI) expands, minimally invasive (Mi) approaches are increasingly being applied. Cardiac surgical techniques can be more difficult through small incisions, and this report analyzes medium-term outcomes for MiAVr facilitated by geometric ring annuloplasty. METHODS: Since 2013, 58 patients were selected for AVr through upper sternotomy third-interspace incisions. The average age was 58.9 ± 15.4 (mean ± SD) years, 71% were male, and preoperative AI grade was 3.6 ± 0.8. Sixty-two percent (36/58) had a proximal aortic replacement for ascending aortic aneurysms (n = 26) and/or remodeling grafts for aortic root aneurysms (n = 10). Annuloplasty rings were placed subannularly (69% trileaflet; 31% bicuspid), and leaflet procedures were performed in 70%. The average ring diameter was 21.6 ± 1.4 mm, and the average aortic clamp time was 113 ± 35 min. RESULTS: After repair, AI grade fell to an average of 0.5 ± 0.6 (p < .0001), with a mean valve gradient of 12.5 ± 7.1 mmHg. No operative mortalities or major complications occurred. Three patients required reoperations for bleeding, and two had pacemakers. At an average follow-up of 38 months (maximal 88 months), three late deaths and no valve-related complications were observed. Four patients required reoperative aortic valve replacement over follow-up, and Kaplan-Meier survival and freedom from reoperation both exceeded 80% at 88 months. At the last follow-up, the average AI grade was 0.7 ± 0.7, and the mean valve gradient was 12.7 ± 6.3 mmHg. CONCLUSIONS: Geometric ring annuloplasty was safe and seemed to facilitate performing AVr ± proximal aortic replacement through Mi incisions. Hemodynamic improvements were significant, medium-term clinical outcomes were acceptable, and results could improve further with experience.


Subject(s)
Aortic Valve Insufficiency , Cardiac Valve Annuloplasty , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adult , Aged , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Humans , Male , Middle Aged , Reoperation , Treatment Outcome
5.
J Digit Imaging ; 35(2): 226-239, 2022 04.
Article in English | MEDLINE | ID: mdl-35083618

ABSTRACT

Feasibility assessment and planning of thoracic endovascular aortic repair (TEVAR) require computed tomography (CT)-based analysis of geometric aortic features to identify adequate landing zones (LZs) for endograft deployment. However, no consensus exists on how to take the necessary measurements from CT image data. We trained and applied a fully automated pipeline embedding a convolutional neural network (CNN), which feeds on 3D CT images to automatically segment the thoracic aorta, detects proximal landing zones (PLZs), and quantifies geometric features that are relevant for TEVAR planning. For 465 CT scans, the thoracic aorta and pulmonary arteries were manually segmented; 395 randomly selected scans with the corresponding ground truth segmentations were used to train a CNN with a 3D U-Net architecture. The remaining 70 scans were used for testing. The trained CNN was embedded within computational geometry processing pipeline which provides aortic metrics of interest for TEVAR planning. The resulting metrics included aortic arch centerline radius of curvature, proximal landing zones (PLZs) maximum diameters, angulation, and tortuosity. These parameters were statistically analyzed to compare standard arches vs. arches with a common origin of the innominate and left carotid artery (CILCA). The trained CNN yielded a mean Dice score of 0.95 and was able to generalize to 9 pathological cases of thoracic aortic aneurysm, providing accurate segmentations. CILCA arches were characterized by significantly greater angulation (p = 0.015) and tortuosity (p = 0.048) in PLZ 3 vs. standard arches. For both arch configurations, comparisons among PLZs revealed statistically significant differences in maximum zone diameters (p < 0.0001), angulation (p < 0.0001), and tortuosity (p < 0.0001). Our tool allows clinicians to obtain objective and repeatable PLZs mapping, and a range of automatically derived complex aortic metrics.


Subject(s)
Blood Vessel Prosthesis Implantation , Deep Learning , Endovascular Procedures , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortography/methods , Blood Vessel Prosthesis , Computed Tomography Angiography , Endovascular Procedures/methods , Humans , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
6.
J Card Surg ; 36(7): 2546-2548, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33797811

ABSTRACT

Sutureless aortic bioprostheses were introduced more than ten years ago, with the aim of decreasing cross-clamp time and thus becoming the first choice in older patients for many surgeons. However, published data are limited to a 5-year follow-up, and some cases of deterioration have already been described. High-risk patients who once have benefitted from a fast sutureless aortic replacement and now are experiencing a prosthesis dysfunction, could take advantage of a percutaneous Valve-in-Sutureless technique. Furthermore, thanks to technological improvement, new transcatheter prostheses have been designed, allowing a more precise positioning. In this report, we described the first Myval-in-Perceval case, which resulted in a safe and effective procedure.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Sutureless Surgical Procedures , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Treatment Outcome
7.
Eur J Vasc Endovasc Surg ; 59(5): 808-816, 2020 May.
Article in English | MEDLINE | ID: mdl-31889656

ABSTRACT

OBJECTIVE: The aim was to investigate whether the "bovine" aortic arch (i.e. arch variant with a common origin of the innominate and left carotid artery (CILCA)) is associated with a consistent geometric configuration of proximal landing zones for thoracic endovascular aortic repair (TEVAR). METHODS: Anonymised thoracic computed tomography (CT) scans of healthy aortas were reviewed to retrieve 100 cases of CILCA. Suitable cases were stratified according to type 1 and 2 CILCA, and also based on type of arch (I, II, and III). Further processing allowed calculation of angulation and tortuosity of the proximal landing zones. Centre lumen line lengths of each proximal landing zone were measured in a view perpendicular to the centre line. All geometric features were compared with those measured in healthy patients with a standard arch configuration (n = 60). Two senior authors independently evaluated the CT scans, and intra- and interobserver repeatability were assessed. RESULTS: The 100 selected patients (63% male) were 71.4 ± 7.7 years old. Type 1 CILCA (62/100) was more prevalent than type 2 CILCA (38/100), and the two groups were comparable in age (p = .11). Zone 3 presented a severe angulation (i.e. > 60°), which was greater than in Zone 2 (p < .001), and a consistently greater tortuosity than Zone 2 (p = .003). This pattern did not differ between type 1 and type 2 CILCA. A greater tortuosity was also observed in Zone 0, which was related to increased elongation of the ascending aorta (i.e. Zone 0), than the standard configuration. The CILCA had an overall greater elongation, and Zone 2 also was specifically longer. When stratifying by type of arch, reversely from Type III to Type I, the CILCA presented a gradual flattening of its transverse tract, which entailed a consistent progressive elongation (p = .03) and kinking of the ascending aorta, with a significant increase of Zone 0 angulation to even a severe degree (p = .001). Also, from Type III to Type I, Zone 2 presented a progressively shorter length (p = .004), which was associated with increased tortuosity (p < .05). Mean intra- and interobserver differences for angulation measurements were 1.4° ± 6.8° (p = .17) and 2.0° ± 10.1° (p = .19), respectively. CONCLUSION: CILCA presents a consistent and peculiar geometric pattern compared with standard arch configuration, which provides relevant information for TEVAR planning, and may have prognostic implications.


Subject(s)
Anatomic Variation , Aorta, Thoracic/anatomy & histology , Aorta, Thoracic/diagnostic imaging , Brachiocephalic Trunk/anatomy & histology , Brachiocephalic Trunk/diagnostic imaging , Carotid Arteries/anatomy & histology , Carotid Arteries/diagnostic imaging , Computed Tomography Angiography , Endovascular Procedures/methods , Aged , Female , Humans , Male , Middle Aged , Retrospective Studies
8.
Ann Vasc Surg ; 69: 413-417, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32479874

ABSTRACT

BACKGROUND: To assess the endograft displacement forces (DF), which quantify the forces exerted by the pulsatile blood flow on the vessel wall and transmitted on the terminal fixation site of the endograft after its deployment in proximal landing zones (PLZs) of the bovine aortic arch variant. METHODS: Thirty healthy aortic computed tomographic angiographies of subjects with bovine arch configuration (10 per type of arch, I-III) were selected for the purpose of the study. A 3-dimensional model of the aortic arch lumen was reconstructed. Computational fluid dynamics modeling was then used to compute DF magnitude and orientation (i.e., x, y, and z axes) in PLZs of each case. DF values were normalized to the corresponding aortic wall area to estimate equivalent surface traction (EST). RESULTS: DF were highest in zone 0, consistently with the greater surface area. DF in zone 3 were much greater than in zone 2 because of a 3-fold greater upward component (z axis) (P < 0.001), being therefore mainly oriented orthogonally to the aortic blood flow and to the vessel longitudinal axis in that zone. EST progressively increased from zone 0 toward more distal PLZs, with EST in zone 3 being much greater than that in zone 2 (P < 0.001). The same pattern was observed after stratification by type of arch. CONCLUSIONS: The bovine arch is associated with a consistent fluid dynamic pattern, which identifies in zone 3 an unfavorable biomechanical environment for endograft deployment.


Subject(s)
Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Computer Simulation , Endovascular Procedures/instrumentation , Hemodynamics , Models, Cardiovascular , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortography , Computed Tomography Angiography , Female , Humans , Hydrodynamics , Male , Pulsatile Flow , Retrospective Studies , Stress, Mechanical
9.
Thorac Cardiovasc Surg ; 68(2): 141-147, 2020 03.
Article in English | MEDLINE | ID: mdl-30114714

ABSTRACT

OBJECTIVES: Increasing experience with minimally invasive cardiac (MIC) aortic valve (AV) replacement makes AV reoperations (rAVR) an appealing alternative to conventional redo surgery. The aim of the study was to compare the perioperative outcome after isolated MIC versus full-sternotomy (FS) rAVR. METHODS: We retrospectively analyzed data of 116 patients from three centers who underwent rAVR by using a FS (n = 70, 60.3%) or a partial upper sternotomy approach (n = 46, 39.7%). Both groups were compared in terms of 30-day mortality by using binary-logistic regression models. Further the EuroSCORE II was used to adjust for preoperative conditions in a multivariable model. Perioperative times and complications were compared between the two groups. RESULTS: There was no statistically significant difference in perioperative mortality between FS (n = 5, 7.1%) and MIC (n = 1, 2.2%) rAVR in the original population (odds ratio [OR] 3.462, 95% confidence interval [CI] 0.391-30,635, p = 0.264) and after adjusting for EuroSCORE II (OR 2.759, 95% CI 0.298-25.567, p = 0.372). Cardiopulmonary bypass- (115.5 minutes vs. 137.5 minutes, p = 0.070) and cross-clamp times (69.0 minutes vs. 81.0 minutes, p = 0.028) were reduced in the MIC group. There was a lower prevalence of postoperative renal failure requiring renal replacement therapy (RRT) in the MIC group 0 and 8.6% (p = 0.041), respectively. No differences were detected between the groups regarding postoperative complications. CONCLUSION: MIC rAVR is associated with reduced cardiopulmonary and cross-clamp times as well as the need for RRT as compared with FS. MIC-rAVR seems to be a viable option in surgical candidates for AV reoperations.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation , Operative Time , Sternotomy , Aged , Austria/epidemiology , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Italy/epidemiology , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/therapy , Prevalence , Reoperation , Retrospective Studies , Risk Factors , Sternotomy/adverse effects , Sternotomy/mortality , Time Factors , Treatment Outcome
10.
J Card Surg ; 35(4): 886-896, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32160341

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: The aim of this meta-analysis was to compare short- and long-term outcomes of patients undergoing mitral annuloplasty (MA) with or without papillary muscle surgery (PMS) for the treatment of ischemic mitral regurgitation (IMR). METHODS: A systematic review and meta-analysis in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement were performed. RESULTS: Nine studies met the inclusion criteria. This meta-analysis identified 478 patients: 228 patients underwent MA alone and 250 patients underwent concomitant PMS. Early mortality was similar between two groups (odds ratio [OR] 1.14, 95% confidence interval [CI], 0.51-2.53; P = .75). PMS was associated at follow-up with a higher freedom from cardiac-related events (P = .050); moreover, although both surgical techniques had a positive impact on ventricular remodeling, the PMS group showed a significant higher reduction of left ventricle end-diastolic diameter (OR, 4.89, 95% CI, 2.77-7.01; P < .001) and left ventricle end-systolic diameter values (OR, 4.11, 95% CI, 1.98-6.24; P < .001). Finally, PMS compared with MA alone was associated with a significant reduction of recurrent mitral regurgitation at follow-up (OR, 3.25, 95% CI, 1.60-6.59; P = .001). CONCLUSIONS: This meta-analysis demonstrated superiority in terms of ventricular remodeling of a combined approach encompassing PMS and MA over MA alone in IMR. Moreover, the association of subvalvular surgery with restrictive MA decreases the incidence of mitral regurgitation recurrence and cardiac-related events at follow-up.


Subject(s)
Mitral Valve Annuloplasty/methods , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Diastole , Follow-Up Studies , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Humans , Mitral Valve Insufficiency/pathology , Mitral Valve Insufficiency/physiopathology , Papillary Muscles/surgery , Secondary Prevention , Severity of Illness Index , Systole , Time Factors , Treatment Outcome , Ventricular Remodeling
12.
J Heart Valve Dis ; 24(6): 669-678, 2015 Nov.
Article in English | MEDLINE | ID: mdl-27997769

ABSTRACT

BACKGROUND: The study aim was to compare the outcome of transapical transcatheter aortic valve replacement (TaTAVR) and traditional aortic valve replacement (AVR) in redo from two real-world registries. METHODS: The 30-day and follow up outcome of 462 patients enrolled in two multicenter redo registries, treated with redo-AVR (RAVR; n = 292 patients) or TaTAVR (n = 170 patients), were analyzed according to VARC-2 criteria, stratified also by propensity-matching analysis. RESULTS: TaTAVR-patients were older and sicker than RAVR patients, and reported a higher all-cause 30-day mortality (p <0.01), a higher risk for all-cause mortality (p = 0.006) and cardiovascular mortality (p = 0.05) at follow up, but similar 30-day cardiovascular mortality (p = 0.12). Prolonged intubation (p <0.01) and Acute Kidney Injury Network (AKIN) 2/3 p = 0.02) prevailed in RAVR. TaTAVR patients reported a higher level of major/life-threatening/disabling bleeding (p <0.01) and 'early safety-events' (ES) (p = 0.04). Thirty-day acute myocardial infarction (AMI), stroke, and follow up freedom from acute heart failure (AHF), from stroke and from reinterventions were similar (p = NS). The NYHA class was better after RAVR (p <0.01). The intermediate-to-high risk (Logistic EuroSCORE RAVR 17.1 ± 8.5; TaTAVR 16.0 ± 17.0) propensity-matched population demonstrated comparable 30-day and follow up all-cause and cardiovascular mortality, ES, AMI, stroke, prolonged intubation, follow up freedom from AHF, from stroke and from reinterventions and NYHA class. TaTAVR still reported lower levels of AKIN 2/3 (2.2% versus 15.6%, p = 0.03) and shorter hospitalization (9.5 ± 3.4 days versus 12.0 ± 7.0 days, p = 0.03). CONCLUSIONS: Outcome differences between RAVR and TaTAVR in redo-scenarios reflect methodological differences and different baseline risk profiles. Propensity-matched patients showed a better renal outcome after TaTAVR. *Drs. Onorati and D'Onofrio contributed equally to this article and should both be considered as first authors.

13.
Thorac Cardiovasc Surg ; 63(6): 501-3, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26177228

ABSTRACT

BACKGROUND: The objective of this study is to evaluate results of the initial experience with sutureless Perceval S for active prosthetic valve endocarditis (PVE). MATERIALS AND METHODS: From October 2012 to April 2014, f: ve patients underwent surgery for aortic PVE with Perceval S bioprosthesis. RESULTS: There was one in-hospital death (20%). Echocardiography performed at discharge showed excellent hemodynamic performance of Perceval S bioprosthesis. CONCLUSION: Aortic valve replacement with Perceval S sutureless valve in patients with PVE is a feasible and safe procedure, associated with low in-hospital mortality and good hemodynamic performance of the prosthesis.


Subject(s)
Bioprosthesis , Endocarditis, Bacterial/surgery , Heart Valve Prosthesis , Prosthesis-Related Infections/surgery , Suture Techniques , Aged , Aortic Valve Stenosis/surgery , Echocardiography , Endocarditis, Bacterial/diagnosis , Female , Follow-Up Studies , Humans , Male , Prosthesis Design , Prosthesis-Related Infections/diagnosis , Reoperation , Retrospective Studies , Treatment Outcome
14.
J Card Surg ; 30(5): 391-5, 2015 May.
Article in English | MEDLINE | ID: mdl-25765903

ABSTRACT

OBJECTIVE: Sutureless prostheses for surgical aortic valve replacement (AVR) are usually used in degenerative calcified aortic stenosis. Less is known on the application of sutureless prostheses for pure aortic incompetence. METHODS: Between 2011 and 2014, 442 patients were operated on with the Perceval aortic sutureless valve implant. We identified 11 patients (10 female, mean age 70.5) who underwent sutureless AVR for pure aortic incompetence (off-label use). Three patients had a left ventricle ejection fraction of 30% or less. Mean logistic EuroSCORE was 15.2 (range 2.2-45.2). In five patients associated mitral procedures (three [60%] repair and two [40%] replacement) were performed. Four procedures were performed through a minimally invasive approach (three right minithoracotomies and one partial sternotomy). RESULTS: Mean cardiopulmonary bypass time was 130.2 min and aortic cross clamp time was 82.2 min. Mean implanted prosthesis size was 24.5 ± 1.3 (median 25) mm (insignificant correlation with preoperative aortic valve annulus measurement by transthoracic echocardiography: 21.6 ± 1.5 [median 21] mm, Pearson's r = 0.373, p = 0.259). One patient died on 24th day after AVR associated with aortic arch replacement and hypothermic circulatory arrest (10 years after correction for type A aortic dissection). No residual para- or intravalvular leakage was present on discharge and 12-month follow-up. No migration of the prosthesis occurred. CONCLUSION: Sutureless AVR is an option in selected patients with aortic incompetence. Preoperative aortic annulus measurement by echocardiography has poor predictive value for estimation of prosthetic valve size.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Wound Closure Techniques , Aged , Aged, 80 and over , Female , Follow-Up Studies , Heart Valve Prosthesis Implantation/instrumentation , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
15.
J Heart Valve Dis ; 23(1): 138-41, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24779341

ABSTRACT

Transcatheter valve-in-valve implantation is an emerging treatment option for high-risk patients with failing mitral bioprostheses. The presence of a paravalvular leak is considered a contraindication to this procedure that would leave the patient with significant residual regurgitation. The case is described of a patient with a severely degenerated 29 mm Carpentier-Edwards mitral bioprosthesis successfully treated by simultaneous transapical transcatheter valve-in-valve implantation and paraprosthetic leak occlusion. The potential advantages of this approach are discussed.


Subject(s)
Bioprosthesis/adverse effects , Cardiac Catheterization , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis/adverse effects , Mitral Valve/surgery , Aged, 80 and over , Humans , Imaging, Three-Dimensional , Male , Mitral Valve/diagnostic imaging , Prosthesis Failure , Reoperation/methods , Ultrasonography, Interventional
16.
Int J Cardiol ; 400: 131701, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38168557

ABSTRACT

BACKGROUND: The new balloon-expandable (BE) Myval transcatheter heart valves (THV) has shown promising early results with low paravalvular leak (PVL) and permanent pacemaker implantation (PPI) rates. Limited data are available regarding its long-term performance. We aimed to compare the 2-year clinical and echocardiographic outcomes of transcatheter aortic valve replacement (TAVR) using the self-expanding (SE) Evolut R and the BE Myval THVs. METHODS: The EVAL study included 166 patients with severe aortic valve stenosis who underwent TAVR either with SE Evolut R (n = 108) or BE Myval (n = 58) THV. Primary objectives include comparison on clinical efficacy (freedom from all-cause mortality, stroke, and cardiovascular hospitalization), echocardiographic performance and PPI rates between the two THVs. RESULTS: At 2-year the BE Myval group showed higher clinical efficacy (86% vs. 66%,HR:2.62, 95%CI 2.2-5.1;p = 0.006), with fewer cardiac hospitalizations (3.4% vs. 13.9%,p = 0.03). No significant differences in all-cause mortality, cardiovascular mortality, or stroke rates were observed. The proportion of patients with ≥moderate PVL was significantly lower in the BE Myval compared to the SE Evolut R group (4%vs. 22%,p = 0.008). The mean transvalvular gradient was significantly higher in the SE group compared to the BE group (9.5 ± 4.3 vs. 6.9 ± 2.2 mmHg,p < 0.001), however there was no difference in the percentage of patients with a mean gradient ≥20 mmHg between the two groups. CONCLUSIONS: Both THVs offer similar 2-year clinical outcomes. The BE Myval THV demonstrated advantages with higher clinical efficacy and lower PVL incidence. Longer follow-up and randomized trials are needed to validate these results and assess Myval's sustained performance and durability.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Prosthesis Design , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Stroke/surgery
17.
Catheter Cardiovasc Interv ; 81(6): 1075-8, 2013 May.
Article in English | MEDLINE | ID: mdl-22744728

ABSTRACT

Transcatheter valve-in-valve implantation is an emerging treatment option for high-risk patients with failing aortic bioprostheses. The presence of the prosthesis stents is thought to prevent coronary artery obstruction, a known complication of transcatheter aortic valve implantation in the native aortic valve. The Sorin Mitroflow aortic bioprosthesis (Sorin Group, Saluggia, Italy) has a particular design in that the pericardial leaflets are mounted outside the valve stent. As a consequence, the pericardial leaflets of this prosthesis may be displaced well away from the stents during the deployment of transcatheter valves. This might explain why both the cases of coronary occlusion following valve-in-valve implantation reported to date occurred in patients with a malfunctioning Mitroflow bioprosthesis. We describe a patient with a malfunctioning 25 mm Mitroflow bioprosthesis successfully treated by percutaneous transcatheter valve-in-valve implantation, and discuss the role that balloon aortic valvuloplasty plays in the performance of this delicate procedure.


Subject(s)
Aortic Valve Insufficiency/therapy , Aortic Valve/surgery , Balloon Valvuloplasty , Bioprosthesis , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Aged , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/adverse effects , Humans , Prosthesis Design , Treatment Outcome
18.
Cardiology ; 124(2): 126-37, 2013.
Article in English | MEDLINE | ID: mdl-23428667

ABSTRACT

OBJECTIVES: It was the aim of this study to assess the pathophysiological, prognostic role of aortic regurgitation (AR) in the 'mixed pictures' of degenerative aortic valve stenoinsufficiency (ASI) by a multimarker clinical approach. METHODS: We enrolled 112 consecutive surgical PATIENTS: 19 with pure valve stenosis (PAS), 39 with mild regurgitation, 29 with severe regurgitation, and 25 controls with annulo-ectatic AR. All underwent complete echocardiography, carotid ultrasound and aortic/coronary multislice computed tomography calcium score evaluation. We determined tissue semiquantitative osteopontin, metalloproteinases (MMPs), tissue inhibitors of MMPs (TIMPs) and circulating brain natriuretic peptide. We evaluated major adverse cardiac events and cardiovascular early, long-term mortality after bioprosthetic valve implantation. RESULTS: Tissue calcification, carotid and coronary atherosclerotic disease were prevalent in PAS versus ASI and AR patients. The multislice computed tomography calcium score (Agatston) was comparable between PAS and ASI (PAS 3,507.3 + 2,442.6; mild AR 4,270.7 + 2,213.5; severe AR 3,568.5 + 1,823.4), but much lower in AR (1,247.8 + 2,708.6). In ASI, a plasma/tissue 'profibrotic' MMP/TIMP balance prevailed, with circulating and echocardiographic indices of myocardial dysfunction. Percentages of major adverse cardiac events and early, long-term mortality were higher in ASI. CONCLUSIONS: In ASI, different, still unknown, genetic and dysplastic factors could work synergically with cardiovascular risk factors, determining a much more adverse myocardial and valve remodeling, resulting in worse clinical outcome.


Subject(s)
Aortic Valve Insufficiency/mortality , Aortic Valve Stenosis/mortality , Biomarkers/metabolism , Aged , Aortic Valve Insufficiency/pathology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/pathology , Atherosclerosis/mortality , Atherosclerosis/pathology , Bioprosthesis/adverse effects , Carotid Stenosis/mortality , Carotid Stenosis/pathology , Case-Control Studies , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Metalloproteases/metabolism , Natriuretic Peptide, Brain/metabolism , Osteopontin/metabolism , Prognosis , Prospective Studies , Tissue Inhibitor of Metalloproteinases/metabolism , Vascular Calcification/mortality , Vascular Calcification/pathology
19.
J Card Surg ; 28(6): 638-40, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23844626

ABSTRACT

We describe a patch augmentation of the anterior leaflet of the tricuspid valve to address tricuspid valve regurgitation due to leaflet retraction. The area of the anterior leaflet is measured using a tricuspid valve annuloplasty sizer; a glutaraldehyde-fixed autologous pericardial patch is trimmed with slight 5 mm oversize. The anterior leaflet is detached and the patch is sutured with three 5/0 running interlocked sutures, then an annuloplasty is performed with an undersized ring. This technique offers an easy and reproducible tool to address tricuspid regurgitation due to lack of leaflet coaptation.


Subject(s)
Cardiac Valve Annuloplasty/methods , Heart Valve Prosthesis Implantation/methods , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Adult , Cardiopulmonary Bypass , Echocardiography , Echocardiography, Transesophageal , Humans , Middle Aged , Pericardium/transplantation , Suture Techniques , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve Insufficiency/diagnostic imaging
20.
J Card Surg ; 28(2): 122-3, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23311618

ABSTRACT

We present a case of early degeneration of a bioprosthesis in the mitral position three years after implantation. Valve explantation revealed complete neo-intima formation and complete fusion of one commissure due to papillary muscle and chordae tendineae embedding in the bioprosthetic leaflets.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Mitral Valve Insufficiency/surgery , Prosthesis Failure/etiology , Aged , Device Removal , Female , Humans , Reoperation