Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 61
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Digit Imaging ; 36(6): 2392-2401, 2023 12.
Article in English | MEDLINE | ID: mdl-37580483

ABSTRACT

Thyroid nodules occur in up to 68% of people, 95% of which are benign. Of the 5% of malignant nodules, many would not result in symptoms or death, yet 600,000 FNAs are still performed annually, with a PPV of 5-7% (up to 30%). Artificial intelligence (AI) systems have the capacity to improve diagnostic accuracy and workflow efficiency when integrated into clinical decision pathways. Previous studies have evaluated AI systems against physicians, whereas we aim to compare the benefits of incorporating AI into their final diagnostic decision. This work analyzed the potential for artificial intelligence (AI)-based decision support systems to improve physician accuracy, variability, and efficiency. The decision support system (DSS) assessed was Koios DS, which provides automated sonographic nodule descriptor predictions and a direct cancer risk assessment aligned to ACR TI-RADS. The study was conducted retrospectively between (08/2020) and (10/2020). The set of cases used included 650 patients (21% male, 79% female) of age 53 ± 15. Fifteen physicians assessed each of the cases in the set, both unassisted and aided by the DSS. The order of the reading condition was randomized, and reading blocks were separated by a period of 4 weeks. The system's impact on reader accuracy was measured by comparing the area under the ROC curve (AUC), sensitivity, and specificity of readers with and without the DSS with FNA as ground truth. The impact on reader variability was evaluated using Pearson's correlation coefficient. The impact on efficiency was determined by comparing the average time per read. There was a statistically significant increase in average AUC of 0.083 [0.066, 0.099] and an increase in sensitivity and specificity of 8.4% [5.4%, 11.3%] and 14% [12.5%, 15.5%], respectively, when aided by Koios DS. The average time per case decreased by 23.6% (p = 0.00017), and the observed Pearson's correlation coefficient increased from r = 0.622 to r = 0.876 when aided by Koios DS. These results indicate that providing physicians with automated clinical decision support significantly improved diagnostic accuracy, as measured by AUC, sensitivity, and specificity, and reduced inter-reader variability and interpretation times.


Subject(s)
Deep Learning , Thyroid Nodule , Humans , Male , Female , Adult , Middle Aged , Aged , Retrospective Studies , Artificial Intelligence , Thyroid Nodule/pathology , Ultrasonography/methods
2.
J Ultrasound Med ; 41(9): 2295-2306, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34918364

ABSTRACT

OBJECTIVES: To investigate the accuracy, sensitivity, and specificity of contrast-enhanced ultrasound (CEUS) for detection of parathyroid adenomas and compare it to those of 4-dimensional computed tomography (4DCT), which has been established as a reliable, effective tool for preoperative localization of parathyroid adenomas. METHODS: About 27 patients with suspected parathyroid pathology underwent imaging evaluations with 4DCT and CEUS and 22 patients subsequently underwent surgical resection of parathyroid lesions. 4DCT and CEUS were performed and interpreted by consensus of two expert radiologists with extensive experience in each modality. Assessment for the side, z-axis (craniocaudal axis), and quadrant of the pathologically proven lesion was performed based on the surgical report. RESULTS: For single-gland disease, the accuracy for CEUS localization to the correct quadrant and side were 81.0 and 90.1% respectively. For single-gland disease, the accuracy for 4DCT localization to the correct quadrant and side were 81.0 and 90.5% respectively. 4DCT localization sensitivity and specificity were comparable to those for CEUS. 4DCT allowed for accurate diagnosis in multigland disease in contradistinction to CEUS. CONCLUSIONS: CEUS is a noninvasive, real-time imaging technique that has relatively high diagnostic confidence and accuracy of localization which are comparable to the accuracy of 4DCT for preoperative parathyroid adenoma detection, characterization, and localization. This technique should be considered for primary preoperative diagnosis, especially in younger patients.


Subject(s)
Adenoma , Hyperparathyroidism, Primary , Parathyroid Neoplasms , Adenoma/diagnostic imaging , Adenoma/surgery , Four-Dimensional Computed Tomography/methods , Humans , Parathyroid Glands/diagnostic imaging , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/surgery , Sensitivity and Specificity , Ultrasonography/methods
3.
J Ultrasound Med ; 39(12): 2457-2468, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32412688

ABSTRACT

Contrast-enhanced ultrasound has emerged as a useful imaging modality for the evaluation of the transplant kidney. Advantages over traditional imaging modalities such as computed tomography and magnetic resonance imaging include the ability to visualize a lesion's enhancement pattern in real time, the lack of nephrotoxicity, and relatively low cost. Potential uses of contrast-enhanced ultrasound include characterization of solid and cystic transplant renal masses, assessment for pyelonephritis and identification of its complications, and evaluation of transplant complications in immediate and delayed settings. Contrast-enhanced ultrasound will likely play an increasing role for evaluating the transplant kidney, as an accurate diagnosis based on imaging can direct treatment and prevent unnecessary interventions.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Kidney Transplantation , Contrast Media , Humans , Kidney/diagnostic imaging , Ultrasonography
4.
Radiology ; 310(1): e233281, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38259213

Subject(s)
Biopsy , Humans
5.
AJR Am J Roentgenol ; 213(3): 672-675, 2019 09.
Article in English | MEDLINE | ID: mdl-31166754

ABSTRACT

OBJECTIVE. The purpose of this study is to assess the association of thyroid cancer with sonographic features of peripheral calcifications. MATERIALS AND METHODS. We retrospectively reviewed patients who had a total of 97 thyroid nodules with peripheral calcifications who underwent ultrasound-guided fine-needle aspiration from 2008 to 2018. Three board-certified radiologists evaluated the nodules for features of peripheral calcifications: the percentage of the nodule involved by peripheral calcifications, whether the calcifications were continuous or discontinuous, the visibility of internal components of the nodule, and the presence of extrusion of soft tissue beyond the calcifications. The correlation of peripheral calcification parameters with the rate of thyroid nodule malignancy was evaluated. In addition, the interobserver agreement between readers was assessed with Cohen kappa coefficient. RESULTS. Of the 97 nodules with peripheral calcifications, 27% (n = 26) were found to be malignant on biopsy. The continuity of peripheral calcifications, visibility of internal components, and extrusion of soft tissue beyond the calcification rim showed no significant association with benign or malignant nodules. Readers had good agreement on peripheral calcification continuity (κ = 0.63; 95% CI, 0.53-0.73) and moderate agreement on internal component visibility (κ = 0.43; 95% CI, 0.35-0.51) and percentage of the nodule involved by rim calcifications (κ = 0.52; 95% CI, 0.44-0.59). There was fair agreement for extranodular soft-tissue extrusion (κ = 0.32, 95% CI, 0.24-0.39). CONCLUSION. Peripheral rim calcifications are highly associated with malignancy. However, specific peripheral rim calcification features do not aid in distinguishing benign from malignant nodules, which may in part be caused by high interobserver variability.


Subject(s)
Calcinosis/diagnostic imaging , Calcinosis/pathology , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Ultrasonography/methods , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle , Female , Humans , Image-Guided Biopsy , Male , Middle Aged , Retrospective Studies
6.
AJR Am J Roentgenol ; 213(6): W264-W271, 2019 12.
Article in English | MEDLINE | ID: mdl-31573849

ABSTRACT

OBJECTIVE. Liver transplant patients are monitored for rejection and hepatic fibrosis and often undergo liver biopsies. The purpose of the present study is to determine whether noninvasive shear wave elastography (SWE) can quantify fibrosis in liver transplant recipients, with the aim of decreasing and possibly eliminating unnecessary biopsies for patients with suspected or progressive hepatic fibrosis. MATERIALS AND METHODS. Between May 1, 2015, and December 31, 2017, our prospective study evaluated 111 adult liver transplant patients (age range, 23-79 years) who underwent 147 ultrasound (US) SWE examinations of the right hepatic lobe followed by biopsies. SWE values were compared with the histologic fibrosis (Metavir) scores of the biopsy samples. SWE threshold values were determined using classification and regression tree analysis by anchoring to the degree of fibrosis. The sensitivity, specificity, positive predictive value, and negative predictive value (with 95% CIs) were calculated on the basis of the threshold value. Overall prediction accuracy was estimated using the AUC value from the ROC curve. RESULTS. From the 147 US SWE examinations and liver biopsies, consistent threshold values were identified for patients with no or minimal fibrosis (Metavir scores of F0 and F1, respectively) compared with significant fibrosis (Metavir scores of F2, F3, or F4). A median SWE value of 1.76 m/s or less denoted no or minimal fibrosis, whereas a value greater than 1.76 m/s denoted significant fibrosis. The sensitivity of US SWE examinations in classifying fibrosis was 0.77 (95% CI, 0.5-0.93). The specificity, positive predictive value, and negative predictive value were 0.79 (95% CI, 0.71-0.86), 0.33 (95% CI, 0.19-0.49), and 0.96 (95% CI, 0.91-0.99), respectively. CONCLUSION. Liver transplant patients may avoid liver biopsy if US SWE examination shows a median shear wave velocity of 1.76 or less, which corresponds to a Metavir score of F0 or F1, denoting no or minimal fibrosis.


Subject(s)
Elasticity Imaging Techniques , Liver Cirrhosis/diagnostic imaging , Liver Transplantation , Adult , Aged , Biopsy , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity
10.
Radiology ; 287(1): 29-36, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29558300

ABSTRACT

In 2017, the Thyroid Imaging Reporting and Data System (TI-RADS) Committee of the American College of Radiology (ACR) published a white paper that presented a new risk-stratification system for classifying thyroid nodules on the basis of their appearance at ultrasonography (US). In ACR TI-RADS, points in five feature categories are summed to determine a risk level from TR1 to TR5. Recommendations for biopsy or US follow-up are based on the nodule's ACR TI-RADS level and its maximum diameter. The purpose of this article is to offer practical guidance on how to implement and apply ACR TI-RADS based on the authors' experience with the system. © RSNA, 2018.


Subject(s)
Radiology Information Systems , Thyroid Diseases/diagnostic imaging , Ultrasonography/methods , Humans , Thyroid Gland/diagnostic imaging
11.
Radiographics ; 37(6): 1831-1838, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29019748

ABSTRACT

Fetal growth restriction is commonly defined as an estimated fetal weight (EFW) that is below the 10th percentile for gestational age. It is associated with an increased risk of intrauterine demise, neonatal morbidity, and neonatal death; therefore, antenatal detection and surveillance with the optimization of delivery timing are necessary to improve pregnancy outcomes. If the estimated due date has been verified and the EFW is below the 10th percentile for gestational age, the underlying cause should be investigated, since the clinical management, outcome, and counseling options are largely dependent on the cause of the growth restriction. Serial ultrasonography (US) for the evaluation of fetal growth and umbilical artery Doppler velocimetry are used to guide pregnancy management decisions. This article describes the accurate US detection and surveillance of fetal growth restriction, discusses the current obstetric and radiology literature regarding the use of Doppler velocimetry in the setting of fetal growth restriction, and describes the techniques for performing umbilical artery Doppler velocimetry. Although various Doppler techniques have been described in the setting of fetal growth restriction, only umbilical artery Doppler assessment is recommended to identify fetuses most at risk for poor outcome and to guide the timing of delivery. The use of other Doppler waveforms in this setting remains investigational. ©RSNA, 2017.


Subject(s)
Fetal Growth Retardation/diagnostic imaging , Ultrasonography, Doppler , Ultrasonography, Prenatal , Adult , Diagnosis, Differential , Female , Humans , Pregnancy
12.
Radiology ; 300(2): 436-437, 2021 08.
Article in English | MEDLINE | ID: mdl-34100687

Subject(s)
Societies, Medical , Humans
14.
Neurosurg Focus ; 40(3): E6, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26926064

ABSTRACT

OBJECTIVE: Intraoperative contrast-enhanced ultrasound (iCEUS) offers dynamic imaging and provides functional data in real time. However, no standardized protocols or validated quantitative data exist to guide its routine use in neurosurgery. The authors aimed to provide further clinical data on the versatile application of iCEUS through a technical note and illustrative case series. METHODS: Five patients undergoing craniotomies for suspected tumors were included. iCEUS was performed using a contrast agent composed of lipid shell microspheres enclosing perflutren (octafluoropropane) gas. Perfusion data were acquired through a time-intensity curve analysis protocol obtained using iCEUS prior to biopsy and/or resection of all lesions. RESULTS: Three primary tumors (gemistocytic astrocytoma, glioblastoma multiforme, and meningioma), 1 metastatic lesion (melanoma), and 1 tumefactive demyelinating lesion (multiple sclerosis) were assessed using real-time iCEUS. No intraoperative complications occurred following multiple administrations of contrast agent in all cases. In all neoplastic cases, iCEUS replicated enhancement patterns observed on preoperative Gd-enhanced MRI, facilitated safe tumor debulking by differentiating neoplastic tissue from normal brain parenchyma, and helped identify arterial feeders and draining veins in and around the surgical cavity. Intraoperative CEUS was also useful in guiding a successful intraoperative needle biopsy of a cerebellar tumefactive demyelinating lesion obtained during real-time perfusion analysis. CONCLUSIONS: Intraoperative CEUS has potential for safe, real-time, dynamic contrast-based imaging for routine use in neurooncological surgery and image-guided biopsy. Intraoperative CEUS eliminates the effect of anatomical distortions associated with standard neuronavigation and provides quantitative perfusion data in real time, which may hold major implications for intraoperative diagnosis, tissue differentiation, and quantification of extent of resection. Further prospective studies will help standardize the role of iCEUS in neurosurgery.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Computer Systems/statistics & numerical data , Craniotomy/methods , Monitoring, Intraoperative/statistics & numerical data , Ultrasonography, Interventional/statistics & numerical data , Aged, 80 and over , Contrast Media , Female , Humans , Male , Middle Aged , Monitoring, Intraoperative/methods , Neurosurgical Procedures/methods , Retrospective Studies , Ultrasonography, Interventional/methods
15.
Abdom Imaging ; 40(7): 2461-71, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26036794

ABSTRACT

PURPOSE: To discuss the evaluation of the enhancement curve over time of the major renal cell carcinoma (RCC) subtypes, oncocytoma, and lipid-poor angiomyolipoma, to aid in the preoperative differentiation of these entities. Differentiation of these lesions is important, given the different prognoses of the subtypes, as well as the desire to avoid resecting benign lesions. METHODS: We discuss findings from CT, MR, and US, but with a special emphasis on contrast-enhanced ultrasound (CEUS). CEUS technique is described, as well as time-intensity curve analysis. RESULTS: Examples of each of the major RCC subtypes (clear cell, papillary, and chromophobe) are shown, as well as examples of oncocytoma and lipid-poor angiomyolipoma. For each lesion, the time-intensity curve of enhancement on CEUS is reviewed, and correlated with the enhancement curve over time reported for multiphase CT and MR. CONCLUSIONS: Preoperative differentiation of the most common solid renal masses is important, and the time-intensity curves of these lesions show some distinguishing features that can aid in this differentiation. The use of CEUS is increasing, and as a modality it is especially well suited to the evaluation of the time-intensity curve.


Subject(s)
Carcinoma, Renal Cell/diagnostic imaging , Contrast Media , Image Enhancement , Kidney Neoplasms/diagnostic imaging , Diagnosis, Differential , Humans , Kidney/diagnostic imaging , Kidney/pathology , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Ultrasonography
16.
J Ultrasound Med ; 34(8): 1489-99, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26206837

ABSTRACT

Neoadjuvant chemotherapy is a mainstay in treating soft tissue sarcomas. Soft tissue sarcomas can show an increase in size and central necrosis, with a decrease in the viable tumor, as an initial response to neoadjuvant chemotherapy. Thus, the maximum tumor diameter may not reliably assess the response to this therapy. Contrast-enhanced sonography may address this limitation. We evaluated 4 patients with soft tissue sarcomas by contrast-enhanced sonography, performed concomitantly with conventional imaging (computed tomography, magnetic resonance imaging, or positron emission tomography). Quantitative analysis was also performed on 1 sarcoma. A viable, enhancing tumor versus tumor necrosis was nearly identical on contrast-enhanced sonography and conventional imaging. Preliminary results demonstrate potential for contrast-enhanced sonographic monitoring of soft tissue sarcomas during neoadjuvant chemotherapy.


Subject(s)
Antineoplastic Agents/therapeutic use , Drug Monitoring/methods , Sarcoma/diagnostic imaging , Sarcoma/drug therapy , Ultrasonography/methods , Chemotherapy, Adjuvant/methods , Contrast Media , Female , Humans , Male , Middle Aged , Neoadjuvant Therapy/methods , Prognosis , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
20.
Radiology ; 272(1): 63-72, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24661245

ABSTRACT

PURPOSE: To analyze the diagnostic performance of shear wave elastography (SWE) in differentiating between benign and malignant breast lesions, with special emphasis on the value of the "stiff rim" sign, as compared with conventional ultrasonography (US). MATERIALS AND METHODS: For this ethics committee-approved retrospective study, all patients provided verbal informed consent for the analysis of their imaging data. A total of 193 consecutive women (age range, 18-82 years; mean age, 46 years) with 193 breast lesions (56 malignant, 137 benign) were included. The stiff rim sign, a qualitative SWE feature, was evaluated at the display setting of less than 180 kPa and at 180 kPa. The quantitative SWE features were assessed. Sensitivity, specificity, the area under the receiver operating characteristic curve (Az), and positive and negative likelihood ratios were calculated for conventional US features, for SWE features, and for combined conventional US and SWE features. RESULTS: Among all qualitative and quantitative SWE features, the stiff rim sign at the display setting (<180 kPa) showed the highest Az (0.918; 95% confidence interval [CI]: 0.870, 0.953), which was comparable to that for conventional US (0.891; 95% CI: 0.838, 0.931) (P = .40). The combination of the stiff rim sign at less than 180 kPa and conventional US features, with a positive likelihood ratio of 12.23 (95% CI: 11.5, 13.0) and a negative likelihood ratio of 0.02 (95% CI: 0.003, 0.1), yielded the highest Az (0.982; 95% CI: 0.951, 0.995)-higher than those for conventional US only and for any single SWE feature alone (P < .001 for all)-and yielded higher sensitivity (98.2% [55 of 56]; 95% CI: 90.4%, 100.0%) and similar specificity (92.0% [126 of 137]; 95% CI: 86.1%, 95.9%) compared with conventional US (P < .001 and P = .58, respectively). With use of this combination, the rate of recommendation of benign lesions for interventional procedures would decrease from 56.9% (78 of 137) (on the basis of conventional US features) to 15.3% (21 of 137), and 100.0% (56 of 56) (95% CI: 93.6%, 100.0%) malignant lesions would be correctly selected for biopsy. CONCLUSION: Adding SWE features, especially the stiff rim sign at the display setting (<180 kPa), to conventional US has the potential to improve the differentiation of breast lesions.


Subject(s)
Breast Neoplasms/diagnostic imaging , Elasticity Imaging Techniques , Adolescent , Adult , Aged , Aged, 80 and over , Breast Neoplasms/pathology , Diagnosis, Differential , Female , Humans , Image Interpretation, Computer-Assisted , Middle Aged , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL