Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
NMR Biomed ; 37(9): e5148, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38556903

ABSTRACT

Intravoxel incoherent motion (IVIM) MRI has emerged as a valuable technique for the assessment of tissue characteristics and perfusion. However, there is limited knowledge about the relationship between IVIM-derived measures and changes at the level of the vascular network. In this study, we investigated the potential use of IVIM MRI as a noninvasive tool for measuring changes in cerebral vascular density. Variations in quantitative immunohistochemical measurements of the vascular density across different regions in the rat brain (cortex, corpus callosum, hippocampus, thalamus, and hypothalamus) were related to the pseudo-diffusion coefficient D* and the flowing blood fraction f in healthy Wistar rats. We assessed whether region-wise differences in the vascular density are reflected by variations in the IVIM measurements and found a significant positive relationship with the pseudo-diffusion coefficient (p < 0.05, ß = 0.24). The effect of cerebrovascular alterations, such as blood-brain barrier (BBB) disruption on the perfusion-related IVIM parameters, is not well understood. Therefore, we investigated the effect of BBB disruption on the IVIM measures in a rat model of metabolic and vascular comorbidities (ZSF1 obese rat) and assessed whether this affects the relationship between the cerebral vascular density and the noninvasive IVIM measurements. We observed increased vascular permeability without detecting any differences in diffusivity, suggesting that BBB leakage is present before changes in the tissue integrity. We observed no significant difference in the relationship between cerebral vascular density and the IVIM measurements in our model of comorbidities compared with healthy normotensive rats.


Subject(s)
Brain , Rats, Wistar , Animals , Brain/blood supply , Brain/diagnostic imaging , Brain/metabolism , Male , Rats , Cerebrovascular Circulation/physiology , Motion , Blood-Brain Barrier/metabolism , Blood-Brain Barrier/diagnostic imaging , Microvascular Density , Biomarkers/metabolism , Magnetic Resonance Imaging , Perfusion
2.
J Vis Exp ; (205)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38587368

ABSTRACT

Acute myocardial infarction (AMI) is a prevalent and high-mortality cardiovascular condition. Despite advancements in revascularization strategies for AMI, it frequently leads to myocardial ischemia-reperfusion injury (IRI), amplifying cardiac damage. Murine models serve as vital tools for investigating both acute injury and chronic myocardial remodeling in vivo. This study presents a unique closed-chest technique for remotely inducing myocardial IRI in mice, enabling the investigation of the very early phase of occlusion and reperfusion using in-vivo imaging such as MRI or PET. The protocol utilizes a remote occlusion method, allowing precise control over ischemia initiation after chest closure. It reduces surgical trauma, enables spontaneous breathing, and enhances experimental consistency. What sets this technique apart is its potential for simultaneous noninvasive imaging, including ultrasound and magnetic resonance imaging (MRI), during occlusion and reperfusion events. It offers a unique opportunity to analyze tissue responses in almost real-time, providing critical insights into processes during ischemia and reperfusion. Extensive systematic testing of this innovative approach was conducted, measuring cardiac necrosis markers for infarction, assessing the area at risk using contrast-enhanced MRI, and staining infarcts at the scar maturation stage. Through these investigations, emphasis was placed on the value of the proposed tool in advancing research approaches to myocardial ischemia-reperfusion injury and accelerating the development of targeted interventions. Preliminary findings demonstrating the feasibility of combining the proposed innovative experimental protocol with noninvasive imaging techniques are presented herein. These initial results highlight the benefit of utilizing the purpose-built animal cradle to remotely induce myocardial ischemia while simultaneously conducting MRI scans.


Subject(s)
Myocardial Infarction , Myocardial Ischemia , Myocardial Reperfusion Injury , Mice , Animals , Myocardial Reperfusion Injury/diagnostic imaging , Myocardial Infarction/diagnostic imaging , Necrosis , Catheters , Disease Models, Animal
3.
J Extracell Biol ; 3(3): e145, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38939412

ABSTRACT

Pancreatic ductal adenocarcinoma (PDAC) is an aggressive malignancy with poor prognosis due to its highly metastatic profile. Intercellular communication between cancer and stromal cells via extracellular vesicles (EVs) is crucial for the premetastatic microenvironment preparation leading to tumour metastasis. This study shows that under the influence of bioactive peptides derived from the extracellular matrix microenvironment, illustrated here by the AG-9 elastin-derived peptide (EDP), PDAC cells secrete more tumour-derived EVs. Compared to PDAC-derived EVs, tumour-derived EVs resulting from AG-9 treatment (PDAC AG-9-derived EVs) significantly stimulated cell proliferation. At constant amount, tumour-derived EVs were similarly taken up by PDAC and HMEC-1 cells. Tumour-derived EVs stimulated cell proliferation, migration, proteinase secretion, and angiogenesis. Bioluminescence imaging allowed tumour-derived EV/FLuc+ tracking in vivo in a PDAC mouse model. The biodistribution of PDAC AG-9-derived EVs was different to PDAC-derived EVs. Our results demonstrate that the microenvironment, through EDP release, may not only influence the genesis of EVs but may also affect tumour progression (tumour growth and angiogenesis), and metastatic homing by modifying the in vivo biodistribution of tumour-derived EVs. They are potential candidates for targeted drug delivery and modulation of tumour progression, and they constitute a new generation of therapeutic tools, merging oncology and genic therapy.

4.
J Magn Reson ; 363: 107702, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38788358

ABSTRACT

Magnetic Resonance Imaging (MRI) often encounters image quality degradation due to magnetic field inhomogeneities. Conventional passive shimming techniques involve the manual placement of discrete magnetic materials, imposing limitations on correcting complex inhomogeneities. To overcome this, we propose a novel 3D printing method utilizing binder jetting technology to enable precise deposition of a continuous range of concentrations of ferromagnetic ink. This approach grants complete control of the magnitude of the magnetic moment within the passive shim enabling tailored corrections of B0 field inhomogeneities. By optimizing the magnetic field distribution using linear programming and an in-house written Computer-Aided Design (CAD) generation software, we printed shims with promising results in generating low spherical harmonic corrections. Experimental evaluations demonstrate feasibility of these 3D printed passive shims to induce target magnetic fields corresponding to second-order spherical harmonic, as evidenced by acquired B0 maps. The electrically insulating properties of the printed shims eliminate the risk of eddy currents and heating, thus ensuring safety. The dimensional fabrication accuracy of the printed shims surpasses previous methods, enabling more precise and localized correction of subject-specific inhomogeneities. The findings highlight the potential of binder-jetted 3D printed passive shims in MRI shimming as a versatile and efficient solution for fabricating passive shims, with the potential to enhance the quality of MRI imaging while also being applicable to other types of Magnetic Resonance systems.

5.
Elife ; 122024 Mar 18.
Article in English | MEDLINE | ID: mdl-38497812

ABSTRACT

Down syndrome (DS) is characterized by skeletal and brain structural malformations, cognitive impairment, altered hippocampal metabolite concentration and gene expression imbalance. These alterations were usually investigated separately, and the potential rescuing effects of green tea extracts enriched in epigallocatechin-3-gallate (GTE-EGCG) provided disparate results due to different experimental conditions. We overcame these limitations by conducting the first longitudinal controlled experiment evaluating genotype and GTE-EGCG prenatal chronic treatment effects before and after treatment discontinuation. Our findings revealed that the Ts65Dn mouse model reflected the pleiotropic nature of DS, exhibiting brachycephalic skull, ventriculomegaly, neurodevelopmental delay, hyperactivity, and impaired memory robustness with altered hippocampal metabolite concentration and gene expression. GTE-EGCG treatment modulated most systems simultaneously but did not rescue DS phenotypes. On the contrary, the treatment exacerbated trisomic phenotypes including body weight, tibia microarchitecture, neurodevelopment, adult cognition, and metabolite concentration, not supporting the therapeutic use of GTE-EGCG as a prenatal chronic treatment. Our results highlight the importance of longitudinal experiments assessing the co-modulation of multiple systems throughout development when characterizing preclinical models in complex disorders and evaluating the pleiotropic effects and general safety of pharmacological treatments.


Subject(s)
Down Syndrome , Animals , Mice , Female , Pregnancy , Down Syndrome/drug therapy , Down Syndrome/genetics , Trisomy , Genitalia , Head , Antioxidants , Disease Models, Animal
SELECTION OF CITATIONS
SEARCH DETAIL