Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 110
Filter
Add more filters

Publication year range
1.
Radiology ; 311(2): e232329, 2024 May.
Article in English | MEDLINE | ID: mdl-38742975

ABSTRACT

Background High rates of provider burnout and turnover, as well as staffing shortages, are creating crises within radiology departments. Identifying ways to support health care workers, such as the Positively Energizing Leadership program, is important during these ongoing crises. Purpose To identify the relationship between leadership behaviors and workplace climate and health care worker outcomes (ie, burnout, intent to leave, and engagement) and to determine whether the positive leadership program could improve workplace climate and health care worker outcomes. Materials and Methods This prospective study involved two parts. First, a web-based survey was administered to faculty and staff in a breast imaging unit of a large academic medical center in February 2021 to identify relationships between leadership behaviors and workplace climate and health care worker outcomes. Second, a web-based survey was administered in February 2023, following the implementation of a positive leadership program, to determine improvement in engagement and reduction of burnout and intent to leave since 2021. Multiple regression, the Sobel test, Pearson correlation, and the t test were used, with a conservative significance level of P < .001. Results The sample consisted of 88 respondents (response rate, 95%) in 2021 and 85 respondents (response rate, 92%) in 2023. Leadership communication was associated with a positive workplace climate (ß = 0.76, P < .001) and a positive workplace climate was associated with improved engagement (ß = 0.53, P < .001), reduction in burnout (ß = -0.42, P < .001), and reduction in intent to leave (ß = -0.49, P < .001). Following a 2-year positive leadership program, improved perceptions were observed for leadership communication (pretest mean, 4.59 ± 1.51 [SD]; posttest mean, 5.80 ± 1.01; t = 5.97, P < .001), workplace climate (pretest mean, 5.09 ± 1.43; posttest mean, 5.77 ± 1.11; t = 3.35, P < .001), and engagement (pretest mean, 5.27 ± 1.20, posttest mean, 5.68 ± 0.96; t = 2.50, P < .01), with a reduction in burnout (pretest mean, 2.69 ± 0.94; posttest mean, 2.18 ± 0.74; t = 3.50, P < .001) and intent to leave (pretest mean, 3.12 ± 2.23; posttest mean, 2.56 ± 1.84; t = 1.78, P < .05). Conclusion After implementation of a positive leadership program in a radiology department breast imaging unit, burnout and intention to leave decreased among health care workers, while engagement increased. © RSNA, 2024 See also the editorial by Thrall in this issue.


Subject(s)
Burnout, Professional , Leadership , Humans , Burnout, Professional/psychology , Female , Prospective Studies , Surveys and Questionnaires , Radiology Department, Hospital/organization & administration , Adult , Male , Job Satisfaction , Intention , Personnel Turnover/statistics & numerical data , Workplace/psychology , Middle Aged
2.
NMR Biomed ; : e5017, 2023 Aug 31.
Article in English | MEDLINE | ID: mdl-37654047

ABSTRACT

The purpose of this study was to assess the quality of clinical brain imaging in healthy subjects and patients on an FDA-approved commercial 0.55 T MRI scanner, and to provide information about the feasibility of using this scanner in a clinical workflow. In this IRB-approved study, brain examinations on the scanner were prospectively performed in 10 healthy subjects (February-April 2022) and retrospectively derived from 44 patients (February-July 2022). Images collected using the following pulse sequences were available for assessment: axial DWI (diffusion-weighted imaging), apparent diffusion coefficient maps, 2D axial fluid-attenuated inversion recovery images, axial susceptibility-weighted images (both magnitude and phase), sagittal T1 -weighted (T1w) Sampling Perfection with Application Optimized Contrast images, sagittal T1w MPRAGE (magnetization prepared rapid gradient echo) with contrast enhancement, axial T1w turbo spin echo (TSE) with and without contrast enhancement, and axial T2 -weighted TSE. Two readers retrospectively and independently evaluated image quality and specific anatomical features in a blinded fashion on a four-point Likert scale, with a score of 1 being unacceptable and 4 being excellent, and determined the ability to answer the clinical question in patients. For each category of image sequences, the mean, standard deviation, and percentage of unacceptable quality images (<2) were calculated. Acceptable (rating ≥ 2) image quality was achieved at 0.55 T in all sequences for patients and 85% of the sequences for healthy subjects. Radiologists were able to answer the clinical question in all patients scanned. In total, 50% of the sequences used in patients and about 60% of the sequences used in healthy subjects exhibited good (rating ≥ 3) image quality. Based on these findings, we conclude that diagnostic quality clinical brain images can be successfully collected on this commercial 0.55 T scanner, indicating that the routine brain imaging protocol may be deployed on this system in the clinical workflow.

3.
NMR Biomed ; 36(3): e4846, 2023 03.
Article in English | MEDLINE | ID: mdl-36259628

ABSTRACT

Magnetic resonance imaging (MRI) technology has profoundly transformed current healthcare systems globally, owing to advances in hardware and software research innovations. Despite these advances, MRI remains largely inaccessible to clinicians, patients, and researchers in low-resource areas, such as Africa. The rapidly growing burden of noncommunicable diseases in Africa underscores the importance of improving access to MRI equipment as well as training and research opportunities on the continent. The Consortium for Advancement of MRI Education and Research in Africa (CAMERA) is a network of African biomedical imaging experts and global partners, implementing novel strategies to advance MRI access and research in Africa. Upon its inception in 2019, CAMERA sets out to identify challenges to MRI usage and provide a framework for addressing MRI needs in the region. To this end, CAMERA conducted a needs assessment survey (NAS) and a series of symposia at international MRI society meetings over a 2-year period. The 68-question NAS was distributed to MRI users in Africa and was completed by 157 clinicians and scientists from across Sub-Saharan Africa (SSA). On average, the number of MRI scanners per million people remained at less than one, of which 39% were obsolete low-field systems but still in use to meet daily clinical needs. The feasibility of coupling stable energy supplies from various sources has contributed to the growing number of higher-field (1.5 T) MRI scanners in the region. However, these systems are underutilized, with only 8% of facilities reporting clinical scans of 15 or more patients per day, per scanner. The most frequently reported MRI scans were neurological and musculoskeletal. The CAMERA NAS combined with the World Health Organization and International Atomic Energy Agency data provides the most up-to-date data on MRI density in Africa and offers a unique insight into Africa's MRI needs. Reported gaps in training, maintenance, and research capacity indicate ongoing challenges in providing sustainable high-value MRI access in SSA. Findings from the NAS and focused discussions at international MRI society meetings provided the basis for the framework presented here for advancing MRI capacity in SSA. While these findings pertain to SSA, the framework provides a model for advancing imaging needs in other low-resource settings.


Subject(s)
Magnetic Resonance Imaging , Humans , Africa South of the Sahara , Surveys and Questionnaires
4.
Eur Radiol ; 33(2): 836-844, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35999374

ABSTRACT

OBJECTIVES: To test the feasibility of using 3D MRF maps with radiomics analysis and machine learning in the characterization of adult brain intra-axial neoplasms. METHODS: 3D MRF acquisition was performed on 78 patients with newly diagnosed brain tumors including 33 glioblastomas (grade IV), 6 grade III gliomas, 12 grade II gliomas, and 27 patients with brain metastases. Regions of enhancing tumor, non-enhancing tumor, and peritumoral edema were segmented and radiomics analysis with gray-level co-occurrence matrices and gray-level run-length matrices was performed. Statistical analysis was performed to identify features capable of differentiating tumors based on type, grade, and isocitrate dehydrogenase (IDH1) status. Receiver operating curve analysis was performed and the area under the curve (AUC) was calculated for tumor classification and grading. For gliomas, Kaplan-Meier analysis for overall survival was performed using MRF T1 features from enhancing tumor region. RESULTS: Multiple MRF T1 and T2 features from enhancing tumor region were capable of differentiating glioblastomas from brain metastases. Although no differences were identified between grade 2 and grade 3 gliomas, differentiation between grade 2 and grade 4 gliomas as well as between grade 3 and grade 4 gliomas was achieved. MRF radiomics features were also able to differentiate IDH1 mutant from the wild-type gliomas. Radiomics T1 features for enhancing tumor region in gliomas correlated to overall survival (p < 0.05). CONCLUSION: Radiomics analysis of 3D MRF maps allows differentiating glioblastomas from metastases and is capable of differentiating glioblastomas from metastases and characterizing gliomas based on grade, IDH1 status, and survival. KEY POINTS: • 3D MRF data analysis using radiomics offers novel tissue characterization of brain tumors. • 3D MRF with radiomics offers glioma characterization based on grade, IDH1 status, and overall patient survival.


Subject(s)
Brain Neoplasms , Glioblastoma , Glioma , Adult , Humans , Feasibility Studies , Magnetic Resonance Imaging , Brain Neoplasms/pathology , Glioma/pathology , Magnetic Resonance Spectroscopy , Isocitrate Dehydrogenase/genetics , Mutation , Neoplasm Grading
5.
AJR Am J Roentgenol ; 220(4): 604-605, 2023 04.
Article in English | MEDLINE | ID: mdl-36129225

ABSTRACT

Radiology has been identified as a subspecialty with exceptionally high rates of incivility among colleagues. Such behaviors are detrimental to the well-being, productivity, and retention of health care practitioners and to the quality of patient care. Addressing incivility has become imperative given current and anticipated staff shortages, yet research from positive organizational scholarship suggests a greater opportunity to be had. Going forward, we need not only to address incivility but also to build purpose-driven, compassionate, and supportive workplaces.


Subject(s)
Incivility , Radiology , Humans , Organizational Culture , Workplace
6.
Magn Reson Med ; 88(4): 1818-1827, 2022 10.
Article in English | MEDLINE | ID: mdl-35713379

ABSTRACT

PURPOSE: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues. METHODS: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same-day test-retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland-Altman analysis. RESULTS: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2 . Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test-retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2  > 0.840). CONCLUSION: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.


Subject(s)
Magnetic Resonance Imaging , Prostate , Brazil , Female , Humans , Image Processing, Computer-Assisted , Male , Phantoms, Imaging , Prostate/diagnostic imaging , Reproducibility of Results
7.
J Magn Reson Imaging ; 55(5): 1322-1339, 2022 05.
Article in English | MEDLINE | ID: mdl-34927776

ABSTRACT

The COVID-19 pandemic highlighted the challenges delivering face-to-face patient care across healthcare systems. In particular the COVID-19 pandemic challenged the imaging community to provide timely access to essential diagnostic imaging modalities while ensuring appropriate safeguards were in place for both patients and personnel. With increasing vaccine availability and greater prevalence of vaccination in communities worldwide we are finally emerging on the other side of the COVID-19 pandemic. As we learned from our institutional and healthcare system responses to the pandemic, maintaining timely access to MR imaging is essential. Radiologists and other imaging providers partnered with their referring providers to ensure that timely access to advanced MR imaging was maintained. On behalf of the International Magnetic Resonance in Medicine (ISMRM) Safety Committee, this white paper is intended to serve as a guide for radiology departments, imaging centers, and other imaging specialists who perform MR imaging to refer to as we prepare for the next pandemic. Lessons learned including strategies to triage and prioritize MR imaging research during a pandemic are discussed. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 5.


Subject(s)
COVID-19 , Pandemics , Humans , Magnetic Resonance Imaging/adverse effects , Pandemics/prevention & control
8.
MAGMA ; 35(4): 557-571, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35419668

ABSTRACT

Multiparametric magnetic resonance imaging (mpMRI) has been adopted as the key tool for detection, localization, characterization, and risk stratification of patients suspected to have prostate cancer. Despite advantages over systematic biopsy, the interpretation of prostate mpMRI has limitations including a steep learning curve, leading to considerable interobserver variation. There is growing interest in clinical translation of quantitative imaging techniques for more objective lesion assessment. However, traditional mapping techniques are slow, precluding their use in the clinic. Magnetic resonance fingerprinting (MRF) is an efficient approach for quantitative maps of multiple tissue properties simultaneously. The T1 and T2 values obtained with MRF have been validated with phantom studies as well as in normal volunteers and patients. Studies have shown that MRF-derived T1 and T2 along with ADC values are all significant independent predictors in the differentiation between normal prostate tissue and prostate cancer, and hold promise in differentiating low and intermediate/high-grade cancers. This review seeks to introduce the basics of the prostate MRF technique, discuss the potential applications of prostate MRF for the characterization of prostate cancer, and describes ongoing areas of research.


Subject(s)
Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms , Biopsy , Humans , Magnetic Resonance Imaging/methods , Male , Phantoms, Imaging , Prostate/diagnostic imaging , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology
9.
Eur J Nucl Med Mol Imaging ; 48(3): 683-693, 2021 03.
Article in English | MEDLINE | ID: mdl-32979059

ABSTRACT

PURPOSE: This is a radiomics study investigating the ability of texture analysis of MRF maps to improve differentiation between intra-axial adult brain tumors and to predict survival in the glioblastoma cohort. METHODS: Magnetic resonance fingerprinting (MRF) acquisition was performed on 31 patients across 3 groups: 17 glioblastomas, 6 low-grade gliomas, and 8 metastases. Using regions of interest for the solid tumor and peritumoral white matter on T1 and T2 maps, second-order texture features were calculated from gray-level co-occurrence matrices and gray-level run length matrices. Selected features were compared across the three tumor groups using Wilcoxon rank-sum test. Receiver operating characteristic curve analysis was performed for each feature. Kaplan-Meier method was used for survival analysis with log rank tests. RESULTS: Low-grade gliomas and glioblastomas had significantly higher run percentage, run entropy, and information measure of correlation 1 on T1 than metastases (p < 0.017). The best separation of all three tumor types was seen utilizing inverse difference normalized and homogeneity values for peritumoral white matter in both T1 and T2 maps (p < 0.017). In solid tumor T2 maps, lower values in entropy and higher values of maximum probability and high-gray run emphasis were associated with longer survival in glioblastoma patients (p < 0.05). Several texture features were associated with longer survival in glioblastoma patients on peritumoral white matter T1 maps (p < 0.05). CONCLUSION: Texture analysis of MRF-derived maps can improve our ability to differentiate common adult brain tumors by characterizing tumor heterogeneity, and may have a role in predicting outcomes in patients with glioblastoma.


Subject(s)
Brain Neoplasms , Glioblastoma , Glioma , Adult , Brain Neoplasms/diagnostic imaging , Glioblastoma/diagnostic imaging , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
10.
J Magn Reson Imaging ; 53(5): 1311-1317, 2021 05.
Article in English | MEDLINE | ID: mdl-32808391

ABSTRACT

Historically, the presence of cardiac implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators (ICDs), was widely considered an absolute contraindication to magnetic resonance imaging (MRI). The recent development of CIEDs with MR Conditional labeling, as well as encouraging results from retrospective studies and a prospective trial on the safety of MRI performed in patients with CIEDs without MR Conditional labeling, have led to a reevaluation of this practice. The purpose of this report is to provide a concise summary of recent developments, including practical guidelines that an institution could adopt for radiologists who choose to image patients with CIEDs that do not have MR Conditional labeling. This report was written on behalf of and approved by the International Society for Magnetic Resonance in Medicine (ISMRM) Safety Committee. LEVEL OF EVIDENCE: 3. TECHNICAL EFFICACY STAGE: 1.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Electronics , Humans , Magnetic Resonance Imaging , Prospective Studies , Retrospective Studies
11.
Eur Radiol ; 31(3): 1336-1346, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32876839

ABSTRACT

OBJECTIVES: To explore the associations between T1 and T2 magnetic resonance fingerprinting (MRF) measurements and corresponding tissue compartment ratios (TCRs) on whole mount histopathology of prostate cancer (PCa) and prostatitis. MATERIALS AND METHODS: A retrospective, IRB-approved, HIPAA-compliant cohort consisting of 14 PCa patients who underwent 3 T multiparametric MRI along with T1 and T2 MRF maps prior to radical prostatectomy was used. Correspondences between whole mount specimens and MRI and MRF were manually established. Prostatitis, PCa, and normal peripheral zone (PZ) regions of interest (ROIs) on pathology were segmented for TCRs of epithelium, lumen, and stroma using two U-net deep learning models. Corresponding ROIs were mapped to T2-weighted MRI (T2w), apparent diffusion coefficient (ADC), and T1 and T2 MRF maps. Their correlations with TCRs were computed using Pearson's correlation coefficient (R). Statistically significant differences in means were assessed using one-way ANOVA. RESULTS: Statistically significant differences (p < 0.01) in means of TCRs and T1 and T2 MRF were observed between PCa, prostatitis, and normal PZ. A negative correlation was observed between T1 and T2 MRF and epithelium (R = - 0.38, - 0.44, p < 0.05) of PCa. T1 MRF was correlated in opposite directions with stroma of PCa and prostatitis (R = 0.35, - 0.44, p < 0.05). T2 MRF was positively correlated with lumen of PCa and prostatitis (R = 0.57, 0.46, p < 0.01). Mean T2 MRF showed significant differences (p < 0.01) between PCa and prostatitis across both transition zone (TZ) and PZ, while mean T1 MRF was significant (p = 0.02) in TZ. CONCLUSION: Significant associations between MRF (T1 in the TZ and T2 in the PZ) and tissue compartments on corresponding histopathology were observed. KEY POINTS: • Mean T2 MRF measurements and ADC within cancerous regions of interest dropped with increasing ISUP prognostic groups (IPG). • Mean T1 and T2 MRF measurements were significantly different (p < 0.001) across IPGs, prostatitis, and normal peripheral zone (NPZ). • T2 MRF showed stronger correlations in the peripheral zone, while T1 MRF showed stronger correlations in the transition zone with histopathology for prostate cancer.


Subject(s)
Deep Learning , Prostatic Neoplasms , Prostatitis , Diffusion Magnetic Resonance Imaging , Epithelium , Humans , Magnetic Resonance Imaging , Male , Prostatic Neoplasms/diagnostic imaging , Prostatitis/diagnostic imaging , Retrospective Studies
12.
AJR Am J Roentgenol ; 217(4): 908-918, 2021 10.
Article in English | MEDLINE | ID: mdl-33336582

ABSTRACT

BACKGROUND. In-gantry MRI-guided biopsy (MRGB) of the prostate has been shown to be more accurate than other targeted prostate biopsy methods. However, the optimal number of cores to obtain during in-gantry MRGB remains undetermined. OBJECTIVE. The purpose of this study was to assess the diagnostic yield of obtaining an incremental number of cores from the primary lesion and of second lesion sampling during in-gantry MRGB of the prostate. METHODS. This retrospective study included 128 men with 163 prostate lesions who underwent in-gantry MRGB between 2016 and 2019. The men had a total of 163 lesions sampled with two or more cores, 121 lesions sampled with three or more cores, and 52 lesions sampled with four or more cores. A total of 40 men underwent sampling of a second lesion. Upgrade on a given core was defined as a greater International Society of Urological Pathology (ISUP) grade group (GG) relative to the previously obtained cores. Clinically significant prostate cancer (csPCa) was defined as ISUP GG 2 or greater. RESULTS. The frequency of any upgrade was 12.9% (21/163) on core 2 versus 10.7% (13/121) on core 3 (p = .29 relative to core 2) and 1.9% (1/52) on core 4 (p = .03 relative to core 3). The frequency of upgrade to csPCa was 7.4% (12/163) on core 2 versus 4.1% (5/121) on core 3 (p = .13 relative to core 2) and 0% (0/52) on core 4 (p = .07 relative to core 3). The frequency of upgrade on core 2 was higher for anterior lesions (p < .001) and lesions with a higher PI-RADS score (p = .007); the frequency of upgrade on core 3 was higher for apical lesions (p = .01) and lesions with a higher PI-RADS score (p = .01). Sampling of a second lesion resulted in an upgrade in a single patient (2.5%; 1/40); both lesions were PI-RADS category 4 and showed csPCa. CONCLUSION. When performing in-gantry MRGB of the prostate, obtaining three cores from the primary lesion is warranted to optimize csPCa diagnosis. Obtaining a fourth core from the primary lesion or sampling a second lesion has very low yield in upgrading cancer diagnoses. CLINICAL IMPACT. To reduce patient discomfort and procedure times, operators may refrain from obtaining more than three cores or second lesion sampling.


Subject(s)
Biopsy, Large-Core Needle/methods , Image-Guided Biopsy/methods , Magnetic Resonance Imaging, Interventional/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Aged , Humans , Male , Middle Aged , Neoplasm Grading , Retrospective Studies
13.
Eur J Nucl Med Mol Imaging ; 47(6): 1435-1445, 2020 06.
Article in English | MEDLINE | ID: mdl-31811342

ABSTRACT

OBJECTIVES: The introduction of the 2016 WHO classification of CNS tumors has made the combined molecular and histopathological characterization of tumors a pivotal part of glioma patient management. Recent publications on radiogenomics-based prediction of the mutational status have demonstrated the predictive potential of imaging-based, non-invasive tissue characterization algorithms. Hence, the aim of this study was to assess the potential of multiparametric 18F-FET PET-MRI including MR fingerprinting accelerated with machine learning and radiomic algorithms to predict tumor grading and mutational status of patients with cerebral gliomas. MATERIALS AND METHODS: 42 patients with suspected primary brain tumor without prior surgical or systemic treatment or biopsy underwent an 18F-FET PET-MRI examination. To differentiate the mutational status and the WHO grade of the cerebral tumors, support vector machine and random forest were trained with the radiomics signature of the multiparametric PET-MRI data including MR fingerprinting. Surgical sampling served as a gold standard for histopathological reference and assessment of mutational status. RESULTS: The 5-fold cross-validated area under the curve in predicting the ATRX mutation was 85.1%, MGMT mutation was 75.7%, IDH1 was 88.7%, and 1p19q was 97.8%. The area under the curve of differentiating low-grade glioma vs. high-grade glioma was 85.2%. CONCLUSION: 18F-FET PET-MRI and MR fingerprinting enable high-quality imaging-based tumor decoding and phenotyping for differentiation of low-grade vs. high-grade gliomas and for prediction of the mutational status of ATRX, IDH1, and 1p19q. These initial results underline the potential of 18F-FET PET-MRI to serve as an alternative to invasive tissue characterization.


Subject(s)
Brain Neoplasms , Glioma , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/genetics , Glioma/diagnostic imaging , Glioma/genetics , Humans , Magnetic Resonance Imaging , Positron-Emission Tomography , Tyrosine
14.
J Magn Reson Imaging ; 51(3): 675-692, 2020 03.
Article in English | MEDLINE | ID: mdl-31264748

ABSTRACT

Magnetic resonance fingerprinting (MRF) is a powerful quantitative MRI technique capable of acquiring multiple property maps simultaneously in a short timeframe. The MRF framework has been adapted to a wide variety of clinical applications, but faces challenges in technical development, and to date has only demonstrated repeatability and reproducibility in small studies. In this review, we discuss the current implementations of MRF and their use in a clinical setting. Based on this analysis, we highlight areas of need that must be addressed before MRF can be fully adopted into the clinic and make recommendations to the MRF community on standardization and validation strategies of MRF techniques. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:675-692.


Subject(s)
Brain , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Phantoms, Imaging , Reproducibility of Results
15.
J Magn Reson Imaging ; 51(4): 993-1007, 2020 04.
Article in English | MEDLINE | ID: mdl-31347226

ABSTRACT

Magnetic resonance fingerprinting (MRF) is a general framework to quantify multiple MR-sensitive tissue properties with a single acquisition. There have been numerous advances in MRF in the years since its inception. In this work we highlight some of the recent technical developments in MRF, focusing on sequence optimization, modifications for reconstruction and pattern matching, new methods for partial volume analysis, and applications of machine and deep learning. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:993-1007.


Subject(s)
Algorithms , Magnetic Resonance Imaging , Brain , Image Processing, Computer-Assisted , Magnetic Resonance Spectroscopy , Phantoms, Imaging
16.
J Magn Reson Imaging ; 52(4): 1044-1052, 2020 10.
Article in English | MEDLINE | ID: mdl-32222092

ABSTRACT

BACKGROUND: Cardiac MR fingerprinting (cMRF) is a novel technique for simultaneous T1 and T2 mapping. PURPOSE: To compare T1 /T2 measurements, repeatability, and map quality between cMRF and standard mapping techniques in healthy subjects. STUDY TYPE: Prospective. POPULATION: In all, 58 subjects (ages 18-60). FIELD STRENGTH/SEQUENCE: cMRF, modified Look-Locker inversion recovery (MOLLI), and T2 -prepared balanced steady-state free precession (bSSFP) at 1.5T. ASSESSMENT: T1 /T2 values were measured in 16 myocardial segments at apical, medial, and basal slice positions. Test-retest and intrareader repeatability were assessed for the medial slice. cMRF and conventional mapping sequences were compared using ordinal and two alternative forced choice (2AFC) ratings. STATISTICAL TESTS: Paired t-tests, Bland-Altman analyses, intraclass correlation coefficient (ICC), linear regression, one-way analysis of variance (ANOVA), and binomial tests. RESULTS: Average T1 measurements were: basal 1007.4±96.5 msec (cMRF), 990.0±45.3 msec (MOLLI); medial 995.0±101.7 msec (cMRF), 995.6±59.7 msec (MOLLI); apical 1006.6±111.2 msec (cMRF); and 981.6±87.6 msec (MOLLI). Average T2 measurements were: basal 40.9±7.0 msec (cMRF), 46.1±3.5 msec (bSSFP); medial 41.0±6.4 msec (cMRF), 47.4±4.1 msec (bSSFP); apical 43.5±6.7 msec (cMRF), 48.0±4.0 msec (bSSFP). A statistically significant bias (cMRF T1 larger than MOLLI T1 ) was observed in basal (17.4 msec) and apical (25.0 msec) slices. For T2 , a statistically significant bias (cMRF lower than bSSFP) was observed for basal (-5.2 msec), medial (-6.3 msec), and apical (-4.5 msec) slices. Precision was lower for cMRF-the average of the standard deviation measured within each slice was 102 msec for cMRF vs. 61 msec for MOLLI T1 , and 6.4 msec for cMRF vs. 4.0 msec for bSSFP T2 . cMRF and conventional techniques had similar test-retest repeatability as quantified by ICC (0.87 cMRF vs. 0.84 MOLLI for T1 ; 0.85 cMRF vs. 0.85 bSSFP for T2 ). In the ordinal image quality comparison, cMRF maps scored higher than conventional sequences for both T1 (all five features) and T2 (four features). DATA CONCLUSION: This work reports on myocardial T1 /T2 measurements in healthy subjects using cMRF and standard mapping sequences. cMRF had slightly lower precision, similar test-retest and intrareader repeatability, and higher scores for map quality. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1 J. Magn. Reson. Imaging 2020;52:1044-1052.


Subject(s)
Heart , Magnetic Resonance Imaging , Adolescent , Adult , Healthy Volunteers , Heart/diagnostic imaging , Humans , Magnetic Resonance Spectroscopy , Middle Aged , Phantoms, Imaging , Prospective Studies , Reproducibility of Results , Young Adult
17.
Radiology ; 290(1): 33-40, 2019 01.
Article in English | MEDLINE | ID: mdl-30375925

ABSTRACT

Purpose To develop a fast three-dimensional method for simultaneous T1 and T2 quantification for breast imaging by using MR fingerprinting. Materials and Methods In this prospective study, variable flip angles and magnetization preparation modules were applied to acquire MR fingerprinting data for each partition of a three-dimensional data set. A fast postprocessing method was implemented by using singular value decomposition. The proposed technique was first validated in phantoms and then applied to 15 healthy female participants (mean age, 24.2 years ± 5.1 [standard deviation]; range, 18-35 years) and 14 female participants with breast cancer (mean age, 55.4 years ± 8.8; range, 39-66 years) between March 2016 and April 2018. The sensitivity of the method to B1 field inhomogeneity was also evaluated by using the Bloch-Siegert method. Results Phantom results showed that accurate and volumetric T1 and T2 quantification was achieved by using the proposed technique. The acquisition time for three-dimensional quantitative maps with a spatial resolution of 1.6 × 1.6 × 3 mm3 was approximately 6 minutes. For healthy participants, averaged T1 and T2 relaxation times for fibroglandular tissues at 3.0 T were 1256 msec ± 171 and 46 msec ± 7, respectively. Compared with normal breast tissues, higher T2 relaxation time (68 msec ± 13) was observed in invasive ductal carcinoma (P < .001), whereas no statistical difference was found in T1 relaxation time (1183 msec ± 256; P = .37). Conclusion A method was developed for breast imaging by using the MR fingerprinting technique, which allows simultaneous and volumetric quantification of T1 and T2 relaxation times for breast tissues. © RSNA, 2018 Online supplemental material is available for this article.


Subject(s)
Breast/diagnostic imaging , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aged , Breast Neoplasms/diagnostic imaging , Female , Humans , Middle Aged , Phantoms, Imaging , Prospective Studies , Young Adult
18.
Radiology ; 292(3): 685-694, 2019 09.
Article in English | MEDLINE | ID: mdl-31335285

ABSTRACT

BackgroundPreliminary studies have shown that MR fingerprinting-based relaxometry combined with apparent diffusion coefficient (ADC) mapping can be used to differentiate normal peripheral zone from prostate cancer and prostatitis. The utility of relaxometry and ADC mapping for the transition zone (TZ) is unknown.PurposeTo evaluate the utility of MR fingerprinting combined with ADC mapping for characterizing TZ lesions.Materials and MethodsTZ lesions that were suspicious for cancer in men who underwent MRI with T2-weighted imaging and ADC mapping (b values, 50-1400 sec/mm2), MR fingerprinting with steady-state free precession, and targeted biopsy (60 in-gantry and 15 cognitive targeting) between September 2014 and August 2018 in a single university hospital were retrospectively analyzed. Two radiologists blinded to Prostate Imaging Reporting and Data System (PI-RADS) scores and pathologic diagnosis drew regions of interest on cancer-suspicious lesions and contralateral visually normal TZs (NTZs) on MR fingerprinting and ADC maps. Linear mixed models compared two-reader means of T1, T2, and ADC. Generalized estimating equations logistic regression analysis was used to evaluate both MR fingerprinting and ADC in differentiating NTZ, cancers and noncancers, clinically significant (Gleason score ≥ 7) cancers from clinically insignificant lesions (noncancers and Gleason 6 cancers), and characterizing PI-RADS version 2 category 3 lesions.ResultsIn 67 men (mean age, 66 years ± 8 [standard deviation]) with 75 lesions, targeted biopsy revealed 37 cancers (six PI-RADS category 3 cancers and 31 PI-RADS category 4 or 5 cancers) and 38 noncancers (31 PI-RADS category 3 lesions and seven PI-RADS category 4 or 5 lesions). The T1, T2, and ADC of NTZ (1800 msec ± 150, 65 msec ± 22, and [1.13 ± 0.19] × 10-3 mm2/sec, respectively) were higher than those in cancers (1450 msec ± 110, 36 msec ± 11, and [0.57 ± 0.13] × 10-3 mm2/sec, respectively; P < .001 for all). The T1, T2, and ADC in cancers were lower than those in noncancers (1620 msec ± 120, 47 msec ± 16, and [0.82 ± 0.13] × 10-3 mm2/sec, respectively; P = .001 for T1 and ADC and P = .03 for T2). The area under the receiver operating characteristic curve (AUC) for T1 plus ADC was 0.94 for separation. T1 and ADC in clinically significant cancers (1440 msec ± 140 and [0.58 ± 0.14] × 10-3 mm2/sec, respectively) were lower than those in clinically insignificant lesions (1580 msec ± 120 and [0.75 ± 0.17] × 10-3 mm2/sec, respectively; P = .001 for all). The AUC for T1 plus ADC was 0.81 for separation. Within PI-RADS category 3 lesions, T1 and ADC of cancers (1430 msec ± 220 and [0.60 ± 0.17] × 10-3 mm2/sec, respectively) were lower than those of noncancers (1630 msec ± 120 and [0.81 ± 0.13] × 10-3 mm2/sec, respectively; P = .006 for T1 and P = .004 for ADC). The AUC for T1 was 0.79 for differentiating category 3 lesions.ConclusionMR fingerprinting-based relaxometry combined with apparent diffusion coefficient mapping may improve transition zone lesion characterization.© RSNA, 2019Online supplemental material is available for this article.


Subject(s)
Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Prostatitis/diagnostic imaging , Aged , Diagnosis, Differential , Humans , Male , Prostate/diagnostic imaging , Reproducibility of Results , Retrospective Studies
19.
Radiology ; 292(2): 429-437, 2019 08.
Article in English | MEDLINE | ID: mdl-31210615

ABSTRACT

Background Only sparse literature investigates the reproducibility and repeatability of relaxometry methods in MRI. However, statistical data on reproducibility and repeatability of any quantitative method is essential for clinical application. Purpose To evaluate the reproducibility and repeatability of two-dimensional fast imaging with steady-state free precession MR fingerprinting in vivo in human brains. Materials and Methods Two-dimensional section-selective MR fingerprinting based on a steady-state free precession sequence with an external radiofrequency transmit field, or B1+, correction was used to generate T1 and T2 maps. This prospective study was conducted between July 2017 and January 2018 with 10 scanners from a single manufacturer, including different models, at four different sites. T1 and T2 relaxation times and their variation across scanners (reproducibility) as well as across repetitions on a scanner (repeatability) were analyzed. The relative deviations of T1 and T2 to the average (95% confidence interval) were calculated for several brain compartments. Results Ten healthy volunteers (mean age ± standard deviation, 28.5 years ± 6.9; eight men, two women) participated in this study. Reproducibility and repeatability of T1 and T2 measures in the human brain varied across brain compartments (1.8%-20.9%) and were higher in solid tissues than in the cerebrospinal fluid. T1 measures in solid tissue brain compartments were more stable compared with T2 measures. The half-widths of the confidence intervals for relative deviations were 3.4% for mean T1 and 8.0% for mean T2 values across scanners. Intrascanner repeatability half-widths of the confidence intervals for relative deviations were in the range of 2.0%-3.1% for T1 and 3.1%-7.9% for T2. Conclusion This study provides values on reproducibility and repeatability of T1 and T2 relaxometry measured with fast imaging with steady-state free precession MR fingerprinting in brain tissues of healthy volunteers. Reproducibility and repeatability are considerably higher in solid brain compartments than in cerebrospinal fluid and are higher for T1 than for T2. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Barkhof and Parker in this issue.


Subject(s)
Brain/anatomy & histology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Brain/physiology , Female , Humans , Male , Prospective Studies , Reference Values , Reproducibility of Results
20.
Magn Reson Med ; 81(3): 1863-1875, 2019 03.
Article in English | MEDLINE | ID: mdl-30394573

ABSTRACT

PURPOSE: This work presents a 4D numerical abdominal phantom, which includes T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques. METHODS: The 3D anatomical mesh models were non-rigidly scaled and shifted by respiratory motion derived from an in vivo scan. A time series of voxelized 3D abdominal phantom images were obtained with contrast determined by the tissue properties and pulse sequence parameters. Two example simulations: (1) 3D T1 mapping under breath-hold and free-breathing acquisition conditions and (2) two different reconstruction techniques for accelerated 3D dynamic contrast-enhanced MRI, are presented. The source codes can be found at https://github.com/SeiberlichLab/Abdominal_MR_Phantom. RESULTS: The proposed 4D abdominal phantom can successfully simulate images and MRI data with nonrigid respiratory motion and specific contrast settings and data sampling schemes. In example 1, the use of a numerical 4D abdominal phantom was demonstrated to aid in the comparison between different approaches for volumetric T1 mapping. In example 2, the average arterial fraction over the healthy hepatic parenchyma as calculated with spiral generalized autocalibrating partial parallel acquisition was closer to that from the fully sampled data than the arterial fraction from conjugate gradient sensitivity encoding, although both are elevated compared to the gold-standard reference. CONCLUSION: This realistic abdominal MR phantom can be used to simulate different pulse sequences and data sampling schemes for the comparison of acquisition and reconstruction methods under controlled conditions that are impossible or prohibitively difficult to perform in vivo.


Subject(s)
Abdomen/diagnostic imaging , Adipose Tissue/diagnostic imaging , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging , Phantoms, Imaging , Algorithms , Computer Simulation , Contrast Media , Diffusion , Fourier Analysis , Humans , Models, Anatomic , Motion , Movement , Perfusion , Respiration
SELECTION OF CITATIONS
SEARCH DETAIL