1.
J Cardiovasc Magn Reson ; 26(2): 101069, 2024 Jul 28.
Article in English | MEDLINE | ID: mdl-39079600

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) cine imaging is still limited by long acquisition times. This study evaluated the clinical utility of an accelerated two-dimensional (2D) cine sequence with deep learning reconstruction (Sonic DL) to decrease acquisition time without compromising quantitative volumetry or image quality. METHODS: A sub-study using 16 participants was performed using Sonic DL at two different acceleration factors (8× and 12×). Quantitative left-ventricular volumetry, function, and mass measurements were compared between the two acceleration factors against a standard cine method. Following this sub-study, 108 participants were prospectively recruited and imaged using a standard cine method and the Sonic DL method with the acceleration factor that more closely matched the reference method. Two experienced clinical readers rated images based on their diagnostic utility and performed all image contouring. Quantitative contrast difference and endocardial border sharpness were also assessed. Left- and right-ventricular volumetry, left-ventricular mass, and myocardial strain measurements were compared between cine methods using Bland-Altman plots, Pearson's correlation, and paired t-tests. Comparative analysis of image quality was measured using Wilcoxon-signed-rank tests and visualized using bar graphs. RESULTS: Sonic DL at an acceleration factor of 8 more closely matched the reference cine method. There were no significant differences found across left ventricular volumetry, function, or mass measurements. In contrast, an acceleration factor of 12 resulted in a 6% (5.51/90.16) reduction of measured ejection fraction when compared to the standard cine method and a 4% (4.32/88.98) reduction of measured ejection fraction when compared to Sonic DL at an acceleration factor of 8. Thus, Sonic DL at an acceleration factor of 8 was chosen for downstream analysis. In the larger cohort, this accelerated cine sequence was successfully performed in all participants and significantly reduced the acquisition time of cine images compared to the standard 2D method (reduction of 37% (5.98/16) p < 0.0001). Diagnostic image quality ratings and quantitative image quality evaluations were statistically not different between the two methods (p > 0.05). Left- and right-ventricular volumetry and circumferential and radial strain were also similar between methods (p > 0.05) but left-ventricular mass and longitudinal strain were over-estimated using the proposed accelerated cine method (mass over-estimated by 3.36 g/m2, p < 0.0001; longitudinal strain over-estimated by 1.97%, p = 0.001). CONCLUSION: This study found that an accelerated 2D cine method with DL reconstruction at an acceleration factor of 8 can reduce CMR cine acquisition time by 37% (5.98/16) without significantly affecting volumetry or image quality. Given the increase of scan time efficiency, this undersampled acquisition method using deep learning reconstruction should be considered for routine clinical CMR.

2.
J Cardiovasc Magn Reson ; 25(1): 81, 2023 12 27.
Article in English | MEDLINE | ID: mdl-38151725

ABSTRACT

BACKGROUND: Endothelial dysfunction and impaired oxygenation of the heart is a hallmark of several diseases, including coronary artery disease, hypertension, diabetes, and sleep apnea. Recent studies indicate that oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging combined with breathing maneuvers may allow for assessing coronary vascular responsiveness as a marker for coronary vascular function in various clinical settings. However, despite the use of OS-CMR in evaluating tissue oxygenation, the reproducibility of these standardized, combined breathing maneuvers as a vasoactive stimulus has yet to be systematically assessed or validated. In this study, we aimed to assess the reproducibility of vasoactive breathing maneuvers to assess vascular function in a population of healthy volunteers. METHODS: Eighteen healthy volunteers were recruited for the study. Inclusion criteria were an age over 18 years and absence of any evidence or knowledge of cardiovascular, neurological, or pulmonary disease. MRI was performed on a clinical 3 T MRI system (MAGNETOM Skyra, Siemens Healthineers, Erlangen, Germany). The OS-CMR acquisition was performed as previously described (1 min hyperventilation followed by a maximal, voluntary breath-hold). Standard statistical tests were performed as appropriate. RESULTS: Data from 18 healthy subjects was analyzed. The healthy volunteers had a mean age of 42 ± 15 years and a mean BMI of 25.4 ± 2.8 kg/m2, with an average heart rate of 72 ± 11 beats per minute, and ten of whom (56%) were female. There were no significant differences between global myocardial oxygenation (%[Formula: see text] SI) after hyperventilation (HV1: - 7.82 [Formula: see text] 5.2; HV2: - 7.89 [Formula: see text] 6.4, p = 0.9) or breath-hold (BH1: 5.34 [Formula: see text] 3.1; BH2: 6.0 [Formula: see text] 3.3, p = 0.5) between the repeated breathing maneuvers. The Bland-Altman analysis showed good agreement (bias: 0.074, SD of bias: 2.93). CONCLUSION: We conclude that in healthy individuals, the myocardial oxygenation response to a standardized breathing maneuver with hyperventilation and a voluntary breath-hold is consistent and highly reproducible. These results corroborate previous evidence for breathing-enhanced OS-CMR as a robust test for coronary vascular function.


Subject(s)
Hyperventilation , Magnetic Resonance Imaging, Cine , Humans , Female , Adult , Middle Aged , Adolescent , Male , Hyperventilation/diagnostic imaging , Reproducibility of Results , Magnetic Resonance Imaging, Cine/methods , Predictive Value of Tests , Heart
3.
J Cardiovasc Transl Res ; 17(3): 705-715, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38229001

ABSTRACT

Oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) is a novel, powerful tool for assessing coronary function in vivo. The data extraction and analysis however are labor-intensive. The objective of this study was to provide an automated approach for the extraction, visualization, and biomarker selection of OS-CMR images. We created a Python-based tool to automate extraction and export of raw patient data, featuring 3336 attributes per participant, into a template compatible with common data analytics frameworks, including the functionality to select predictive features for the given disease state. Each analysis was completed in about 2 min. The features selected by both ANOVA and MIC significantly outperformed (p < 0.001) the null set and complete set of features in two datasets, with mean AUROC scores of 0.89eatures f 0.94lete set of features in two datasets, with mean AUROC scores that our tool is suitable for automated data extraction and analysis of OS-CMR images.


Subject(s)
Image Interpretation, Computer-Assisted , Predictive Value of Tests , Humans , Magnetic Resonance Imaging , Data Mining , Automation , Oxygen/blood , Databases, Factual , Reproducibility of Results , Coronary Vessels/diagnostic imaging , Male , Coronary Artery Disease/diagnostic imaging
4.
Eur Heart J Cardiovasc Imaging ; 25(8): 1136-1143, 2024 Jul 31.
Article in English | MEDLINE | ID: mdl-38546135

ABSTRACT

AIMS: Women with angina and non-obstructive coronary artery disease (ANOCA) have a heightened risk for cardiovascular events, and the pathophysiology for ischaemic symptoms may be related to alterations in microvascular structure and function. We examined the use of breathing-enhanced oxygenation-sensitive cardiac magnetic resonance imaging (OS-CMR) using vasoactive breathing manoeuvres to assess myocardial oxygenation in women with ANOCA. METHODS AND RESULTS: We recruited women (aged 40-65 years) from two sites in Canada who presented to healthcare with persistent retrosternal chest pain and found to have ANOCA, or without a history of cardiovascular disease. All participants were scanned using a clinical 3T MRI scanner, and OS-CMR images were acquired over a breath hold following paced hyperventilation to measure global and regional measurements of heterogeneity. Fifty-four women with ANOCA (age: 55 ± 6.2 years) and 48 healthy controls (age: 51.2 ± 4.8 years) were recruited. There was no significant difference in volume, function, mass, or global myocardial oxygenation between the two groups [mean %Δ in signal intensity (SI): 4.9 (±7.3) vs. 4.5 (±10.1), P = 0.82]. Women with ANOCA had higher regional variations in myocardial oxygenation in circumferential [median %Δ in SI: 5.1 (2.0-7.6) vs. 2.2 (1.4-3.5), P = 0.0004] and longitudinal directions [median %Δ in SI: 11.4 (5.4-16.7) vs. 6.0 (3.0-7.0), P = 0.001], which remained present in a multivariate model. CONCLUSION: Heterogeneous myocardial oxygenation may explain ischaemic symptoms without any associated epicardial obstructive coronary artery disease. Regional variations in myocardial oxygenation on OS-CMR could serve as an important diagnostic marker for microvascular dysfunction in women with ANOCA.


Subject(s)
Angina Pectoris , Coronary Artery Disease , Magnetic Resonance Imaging, Cine , Humans , Female , Middle Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Adult , Angina Pectoris/diagnostic imaging , Angina Pectoris/physiopathology , Aged , Magnetic Resonance Imaging, Cine/methods , Case-Control Studies , Canada , Oxygen Consumption/physiology , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Coronary Circulation/physiology