Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
J Vasc Interv Radiol ; 34(5): 871-878.e3, 2023 05.
Article in English | MEDLINE | ID: mdl-36646207

ABSTRACT

PURPOSE: To develop a vascular intervention simulation model that replicates the characteristics of a human patient and to compare the mechanical properties of a 3-dimensional (3D)-printed transparent flexible resin with those of porcine arteries using the elastic modulus (E) and kinetic friction coefficient (µk). MATERIALS AND METHODS: Resin plates were created from a transparent flexible resin using a 3D printer. Porcine artery plates were prepared by excising the aorta. E values and the adhesive strengths of the resin and arterial surfaces toward a polyethylene plate, were measured with a tensile-compressive mechanical tester. Resin transparency was measured using an ultraviolet-visible light spectrometer. The µk value of the resin plate surface after applying silicone spray for 1-5 seconds and that of the artery were measured using a translational friction tester. RESULTS: E values differed significantly between the arteries and resin plates at each curing time (0.20 MPa ± 0.04 vs 8.53 MPa ± 2.37 for a curing time of 1 minute; P < .05). The resin was stiffer than the arteries, regardless of the curing times. The visible light transmittance and adhesive strength of the resin decreased as the curing time increased. The adhesive strength of the artery was the lowest. The µk value of the silicone-coated resin surface created by applying silicone for 2-3 seconds (thickness of the silicone layer, 1.6-2.0 µm) was comparable with that of the artery, indicating that the coating imparted a similar slippage to the resin as to the living artery. CONCLUSIONS: A transparent flexible resin is useful for creating a transparent and slippery vascular model for vascular intervention simulation.


Subject(s)
Arteries , Light , Humans , Swine , Animals , Surface Properties , Silicones , Materials Testing , Tensile Strength
2.
Radiol Case Rep ; 17(10): 3578-3586, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35923334

ABSTRACT

The development of three-dimensional printers has facilitated the creation of patient-specific hollow vessel models. Preoperative simulations using these types of models have improved our ability to select appropriate devices and embolic materials before performing complex endovascular procedures. This report describes 2 cases of high-flow renal arteriovenous fistulas (r-AVFs) that were successfully treated via short-segment embolization using the preloading coil-in-plug (p-CIP) technique. To our knowledge, this is the first report of r-AVF being treated using the p-CIP technique. Our findings demonstrate that preoperative simulation has the potential to improve the safety and reliability of complex vascular embolization procedures.

SELECTION OF CITATIONS
SEARCH DETAIL