Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 201
Filter
Add more filters

Publication year range
1.
Eur Respir J ; 64(3)2024 Sep.
Article in English | MEDLINE | ID: mdl-38991707

ABSTRACT

BACKGROUND: Sleep disordered breathing (SDB) has been associated with less myocardial salvage and smaller infarct size reduction after acute myocardial infarction (AMI). The Treatment of sleep apnoea Early After Myocardial infarction with Adaptive Servo-Ventilation (TEAM-ASV I) trial investigated the effects of adding adaptive servo-ventilation (ASV) for SDB to standard therapy on the myocardial salvage index (MSI) and change in infarct size within 12 weeks after AMI. METHODS: In this multicentre, randomised, open-label trial, patients with AMI and successful percutaneous coronary intervention within 24 h after symptom onset plus SDB (apnoea-hypopnoea index ≥15 events·h-1) were randomised to standard medical therapy alone (control) or plus ASV (starting 3.6±1.4 days post-AMI). The primary outcome was the MSI at 12 weeks post-AMI. Cardiac magnetic resonance (CMR) imaging was performed at ≤5 days and 12 weeks after AMI. RESULTS: 76 individuals were enrolled from February 2014 to August 2020; 39 had complete CMR data for analysis of the primary end-point. The MSI was significantly higher in the ASV versus control group (difference 14.6% (95% CI 0.14-29.1%); p=0.048). At 12 weeks, absolute (6.6 (95% CI 4.8-8.5) versus 2.8 (95% CI 0.9-4.8) % of left ventricular mass; p=0.003) and relative (44 (95% CI 30-57) versus 21 (95% CI 6-35) % of baseline; p=0.013) reductions in infarct size were greater in the ASV versus control group. No serious treatment-related adverse events occurred. CONCLUSIONS: Early treatment of SDB with ASV improved the MSI and decreased infarct size at 12 weeks after AMI. Larger randomised trials are required to confirm these findings.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , Sleep Apnea Syndromes , Humans , Male , Female , Middle Aged , Sleep Apnea Syndromes/therapy , Sleep Apnea Syndromes/complications , Myocardial Infarction/complications , Myocardial Infarction/therapy , Aged , Proof of Concept Study , Treatment Outcome , Magnetic Resonance Imaging
2.
J Cardiovasc Magn Reson ; 26(2): 101081, 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-39127260

ABSTRACT

BACKGROUND: Four-dimensional cardiovascular magnetic resonance flow imaging (4D flow CMR) plays an important role in assessing cardiovascular diseases. However, the manual or semi-automatic segmentation of aortic vessel boundaries in 4D flow data introduces variability and limits the reproducibility of aortic hemodynamics visualization and quantitative flow-related parameter computation. This paper explores the potential of deep learning to improve 4D flow CMR segmentation by developing models for automatic segmentation and analyzes the impact of the training data on the generalization of the model across different sites, scanner vendors, sequences, and pathologies. METHODS: The study population consists of 260 4D flow CMR datasets, including subjects without known aortic pathology, healthy volunteers, and patients with bicuspid aortic valve (BAV) examined at different hospitals. The dataset was split to train segmentation models on subsets with different representations of characteristics, such as pathology, gender, age, scanner model, vendor, and field strength. An enhanced three-dimensional U-net convolutional neural network (CNN) architecture with residual units was trained for time-resolved two-dimensional aortic cross-sectional segmentation. Model performance was evaluated using Dice score, Hausdorff distance, and average symmetric surface distance on test data, datasets with characteristics not represented in the training set (model-specific), and an overall evaluation set. Standard diagnostic flow parameters were computed and compared with manual segmentation results using Bland-Altman analysis and interclass correlation. RESULTS: The representation of technical factors, such as scanner vendor and field strength, in the training dataset had the strongest influence on the overall segmentation performance. Age had a greater impact than gender. Models solely trained on BAV patients' datasets performed well on datasets of healthy subjects but not vice versa. CONCLUSION: This study highlights the importance of considering a heterogeneous dataset for the training of widely applicable automatic CNN segmentations in 4D flow CMR, with a particular focus on the inclusion of different pathologies and technical aspects of data acquisition.

3.
J Cardiovasc Magn Reson ; 26(2): 101055, 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38971501

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly utilized to evaluate expanding cardiovascular conditions. The Society for Cardiovascular Magnetic Resonance (SCMR) Registry is a central repository for real-world clinical data to support cardiovascular research, including those relating to outcomes, quality improvement, and machine learning. The SCMR Registry is built on a regulatory-compliant, cloud-based infrastructure that houses searchable content and Digital Imaging and Communications in Medicine images. The goal of this study is to summarize the status of the SCMR Registry at 150,000 exams. METHODS: The processes for data security, data submission, and research access are outlined. We interrogated the Registry and presented a summary of its contents. RESULTS: Data were compiled from 154,458 CMR scans across 20 United States sites, containing 299,622,066 total images (∼100 terabytes of storage). Across reported values, the human subjects had an average age of 58 years (range 1 month to >90 years old), were 44% (63,070/145,275) female, 72% (69,766/98,008) Caucasian, and had a mortality rate of 8% (9,962/132,979). The most common indication was cardiomyopathy (35,369/131,581, 27%), and most frequently used current procedural terminology code was 75561 (57,195/162,901, 35%). Macrocyclic gadolinium-based contrast agents represented 89% (83,089/93,884) of contrast utilization after 2015. Short-axis cines were performed in 99% (76,859/77,871) of tagged scans, short-axis late gadolinium enhancement (LGE) in 66% (51,591/77,871), and stress perfusion sequences in 30% (23,241/77,871). Mortality data demonstrated increased mortality in patients with left ventricular ejection fraction <35%, the presence of wall motion abnormalities, stress perfusion defects, and infarct LGE, compared to those without these markers. There were 456,678 patient-years of all-cause mortality follow-up, with a median follow-up time of 3.6 years. CONCLUSION: The vision of the SCMR Registry is to promote evidence-based utilization of CMR through a collaborative effort by providing a web mechanism for centers to securely upload de-identified data and images for research, education, and quality control. The Registry quantifies changing practice over time and supports large-scale real-world multicenter observational studies of prognostic utility.

4.
Infection ; 52(1): 93-104, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37434025

ABSTRACT

BACKGROUND: The severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) pandemic causes a high burden of acute and long-term morbidity and mortality worldwide despite global efforts in containment, prophylaxis, and therapy. With unprecedented speed, the global scientific community has generated pivotal insights into the pathogen and the host response evoked by the infection. However, deeper characterization of the pathophysiology and pathology remains a high priority to reduce morbidity and mortality of coronavirus disease 2019 (COVID-19). METHODS: NAPKON-HAP is a multi-centered prospective observational study with a long-term follow-up phase of up to 36 months post-SARS-CoV-2 infection. It constitutes a central platform for harmonized data and biospecimen for interdisciplinary characterization of acute SARS-CoV-2 infection and long-term outcomes of diverging disease severities of hospitalized patients. RESULTS: Primary outcome measures include clinical scores and quality of life assessment captured during hospitalization and at outpatient follow-up visits to assess acute and chronic morbidity. Secondary measures include results of biomolecular and immunological investigations and assessment of organ-specific involvement during and post-COVID-19 infection. NAPKON-HAP constitutes a national platform to provide accessibility and usability of the comprehensive data and biospecimen collection to global research. CONCLUSION: NAPKON-HAP establishes a platform with standardized high-resolution data and biospecimen collection of hospitalized COVID-19 patients of different disease severities in Germany. With this study, we will add significant scientific insights and provide high-quality data to aid researchers to investigate COVID-19 pathophysiology, pathology, and chronic morbidity.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , SARS-CoV-2 , Pandemics/prevention & control , Quality of Life , Germany/epidemiology , Observational Studies as Topic
5.
Heart Fail Rev ; 27(4): 1261-1279, 2022 07.
Article in English | MEDLINE | ID: mdl-34041679

ABSTRACT

Pressure-volume (PV) analysis is the most comprehensive way to describe cardiac function, giving insights into cardiac mechanics and energetics. However, PV analysis still remains a highly invasive and time-consuming method, preventing it from integration into clinical practice. Most of the echocardiographic parameters currently used in the clinical routine to characterize left ventricular (LV) systolic function, such as LV ejection fraction and LV global longitudinal strain, do not take the pressure developed within the LV into account and therefore fall too short in describing LV function as a hydraulic pump. Recently, LV pressure-strain analysis has been introduced as a new technique to assess myocardial work in a non-invasive fashion. This new method showed new insights in comparison to invasive measurements and was validated in different cardiac pathologies, e.g., for the detection of coronary artery disease, cardiac resynchronization therapy (CRT)-response prediction, and different forms of heart failure. Non-invasively assessed myocardial work may play a major role in guiding therapies and estimating prognosis. However, its incremental prognostic validity in comparison to common echocardiographic parameters remains unclear. This review aims to provide an overview of pressure-strain analysis, including its current application in the clinical arena, as well as potential fields of exploitation.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Echocardiography , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Myocardium , Stroke Volume/physiology , Ventricular Function, Left/physiology
6.
J Magn Reson Imaging ; 55(1): 211-222, 2022 01.
Article in English | MEDLINE | ID: mdl-34173297

ABSTRACT

BACKGROUND: Implementation of four-dimensional flow magnetic resonance (4D Flow MR) in clinical routine requires awareness of confounders. PURPOSE: To investigate inter-vendor comparability of 4D Flow MR derived aortic hemodynamic parameters, assess scan-rescan repeatability, and intra- and interobserver reproducibility. STUDY TYPE: Prospective multicenter study. POPULATION: Fifteen healthy volunteers (age 24.5 ± 5.3 years, 8 females). FIELD STRENGTH/SEQUENCE: 3 T, vendor-provided and clinically used 4D Flow MR sequences of each site. ASSESSMENT: Forward flow volume, peak velocity, average, and maximum wall shear stress (WSS) were assessed via nine planes (P1-P9) throughout the thoracic aorta by a single observer (AD, 2 years of experience). Inter-vendor comparability as well as scan-rescan, intra- and interobserver reproducibility were examined. STATISTICAL TESTS: Equivalence was tested setting the 95% confidence interval of intraobserver and scan-rescan difference as the limit of clinical acceptable disagreement. Intraclass correlation coefficient (ICC) and Bland-Altman plots were used for scan-rescan reproducibility and intra- and interobserver agreement. A P-value <0.05 was considered statistically significant. ICCs ≥ 0.75 indicated strong correlation (>0.9: excellent, 0.75-0.9: good). RESULTS: Ten volunteers finished the complete study successfully. 4D flow derived hemodynamic parameters between scanners of three different vendors are not equivalent exceeding the equivalence range. P3-P9 differed significantly between all three scanners for forward flow (59.1 ± 13.1 mL vs. 68.1 ± 12.0 mL vs. 55.4 ± 13.1 mL), maximum WSS (1842.0 ± 190.5 mPa vs. 1969.5 ± 398.7 mPa vs. 1500.6 ± 247.2 mPa), average WSS (1400.0 ± 149.3 mPa vs. 1322.6 ± 211.8 mPa vs. 1142.0 ± 198.5 mPa), and peak velocity between scanners I vs. III (114.7 ± 12.6 cm/s vs. 101.3 ± 15.6 cm/s). Overall, the plane location at the sinotubular junction (P1) presented most inter-vendor stability (forward: 78.5 ± 15.1 mL vs. 80.3 ± 15.4 mL vs. 79.5 ± 19.9 mL [P = 0.368]; peak: 126.4 ± 16.7 cm/s vs. 119.7 ± 13.6 cm/s vs. 111.2 ± 22.6 cm/s [P = 0.097]). Scan-rescan reproducibility and intra- and interobserver variability were good to excellent (ICC ≥ 0.8) with best agreement for forward flow (ICC ≥ 0.98). DATA CONCLUSION: The clinical protocol used at three different sites led to differences in hemodynamic parameters assessed by 4D flow. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Subject(s)
Hemodynamics , Magnetic Resonance Imaging , Adult , Humans , Magnetic Resonance Spectroscopy , Prospective Studies , Reproducibility of Results , Young Adult
7.
J Cardiovasc Magn Reson ; 24(1): 1, 2022 01 06.
Article in English | MEDLINE | ID: mdl-34986851

ABSTRACT

BACKGROUND: Although prior reports have evaluated the clinical and cost impacts of cardiovascular magnetic resonance (CMR) for low-to-intermediate-risk patients with suspected significant coronary artery disease (CAD), the cost-effectiveness of CMR compared to relevant comparators remains poorly understood. We aimed to summarize the cost-effectiveness literature on CMR for CAD and create a cost-effectiveness calculator, useable worldwide, to approximate the cost-per-quality-adjusted-life-year (QALY) of CMR and relevant comparators with context-specific patient-level and system-level inputs. METHODS: We searched the Tufts Cost-Effectiveness Analysis Registry and PubMed for cost-per-QALY or cost-per-life-year-saved studies of CMR to detect significant CAD. We also developed a linear regression meta-model (CMR Cost-Effectiveness Calculator) based on a larger CMR cost-effectiveness simulation model that can approximate CMR lifetime discount cost, QALY, and cost effectiveness compared to relevant comparators [such as single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA)] or invasive coronary angiography. RESULTS: CMR was cost-effective for evaluation of significant CAD (either health-improving and cost saving or having a cost-per-QALY or cost-per-life-year result lower than the cost-effectiveness threshold) versus its relevant comparator in 10 out of 15 studies, with 3 studies reporting uncertain cost effectiveness, and 2 studies showing CCTA was optimal. Our cost-effectiveness calculator showed that CCTA was not cost-effective in the US compared to CMR when the most recent publications on imaging performance were included in the model. CONCLUSIONS: Based on current world-wide evidence in the literature, CMR usually represents a cost-effective option compared to relevant comparators to assess for significant CAD.


Subject(s)
Coronary Artery Disease , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Cost-Benefit Analysis , Humans , Magnetic Resonance Spectroscopy , Predictive Value of Tests
8.
N Engl J Med ; 388(6): 575, 2023 02 09.
Article in English | MEDLINE | ID: mdl-36780689

Subject(s)
Myocarditis , Humans
9.
Magn Reson Med ; 85(1): 357-368, 2021 01.
Article in English | MEDLINE | ID: mdl-32851707

ABSTRACT

PURPOSE: Myocardial feature-tracking (FT) deformation imaging is superior for risk stratification compared with volumetric approaches. Because there is no clear recommendation regarding FT postprocessing, we compared different FT-strain analyses with reference standard techniques, including tagging and strain-encoded (SENC) MRI. METHODS: Feature-tracking software from four different vendors (TomTec, Medis, Circle [CVI], and Neosoft), tagging (Segment), and fastSENC (MyoStrain) were used to determine left ventricular global circumferential strains (GCS) and longitudinal strains (GLS) in 12 healthy volunteers and 12 patients with heart failure. Variability and agreements were assessed using intraclass correlation coefficients for absolute agreement (ICCa) and consistency (ICCc) as well as Pearson correlation coefficients. RESULTS: For FT-GCS, consistency was excellent comparing different FT vendors (ICCc = 0.84-0.97, r = 0.86-0.95) and in comparison to fast SENC (ICCc = 0.78-0.89, r = 0.73-0.81). FT-GCS consistency was excellent compared with tagging (ICCc = 0.79-0.85, r = 0.74-0.77) except for TomTec (ICCc = 0.68, r = 0.72). Absolute FT-GCS agreements among FT vendors were highest for CVI and Medis (ICCa = 0.96) and lowest for TomTec and Neosoft (ICCa = 0.32). Similarly, absolute FT-GCS agreements were excellent for CVI and Medis compared with both tagging and fast SENC (ICCa = 0.84-0.88), good to excellent for Neosoft (ICCa = 0.77 and 0.64), and lowest for TomTec (ICCa = 0.41 and 0.47). For FT-GLS, consistency was excellent (ICCc ≥ 0.86, r ≥ 0.76). Absolute agreements among FT vendors were excellent (ICCa = 0.91-0.93) or good to excellent for TomTec (ICCa = 0.69-0.85). Absolute agreements (ICCa) were good (CVI 0.70, Medis 0.60) and fair (TomTec 0.41, Neosoft 0.59) compared with tagging, but excellent compared with fast SENC (ICCa = 0.77-0.90). CONCLUSION: Although absolute agreements differ depending on deformation assessment approaches, consistency and correlation are consistently high regardless of the method chosen, thus indicating reliable strain assessment. Further standardisation and introduction of uniform references is warranted for routine clinical implementation.


Subject(s)
Magnetic Resonance Imaging, Cine , Magnetic Resonance Imaging , Heart Ventricles/diagnostic imaging , Humans , Myocardium , Reproducibility of Results , Ventricular Function, Left
10.
Catheter Cardiovasc Interv ; 97(7): E936-E944, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33236497

ABSTRACT

BACKGROUND: High-sensitivity C-reactive protein (hsCRP) predicts outcomes after percutaneous coronary intervention (PCI). OBJECTIVE: We studied the prevalence and prognostic impact of hsCRP elevation according to age in men and women undergoing PCI. METHODS: We included patients undergoing PCI at our center from 2010 until 2017, excluding those with myocardial infarction (MI) on presentation, neoplastic disease and hsCRP >10 mg/L at baseline. Elevated hsCRP was defined as >3 mg/L. The outcome of interest was major adverse cardiac events (MACE) consisting of all-cause death, MI and target vessel revascularization. The association between hsCRP elevation and outcomes was assessed using adjusted Cox models. RESULTS: 10,432 men and 4,345 women were included. Elevation of hsCRP was present in 25.7% of men and 37.0% of women (p < .01). In men, prevalence of hsCRP elevation was stable across age strata (ptrend  = .42). In women, hsCRP elevation was most prevalent in patients <50 years (44.6%) and decreased stepwise with increasing age (ptrend < .001). After stratifying the population into age quartiles (Q1: <59 years, Q2: 59-66 years, Q3: 67-74 years, Q4: ≥75 years), hsCRP elevation was associated with increased risk of MACE across all age groups in men (HR [95% CI] Q1: 1.49 [1.12-1.98]; Q2: 1.51 [1.21-2.06]; Q3: 1.76 [1.27-2.51]; Q4: 1.43[1.03-1.97]). In women, hsCRP elevation was associated with increased risk of MACE only among older patients (HR [95% CI] Q1: 1.08 [0.64-0.82]; Q2: 1.52 [0.93-2.46]; Q3: 1.65 [1.08-2.50]; Q4: 1.52 [1.02-1.28]). CONCLUSION: Among patients undergoing PCI, prevalence and prognostic value of hsCRP elevation were age-dependent exclusively in women.


Subject(s)
C-Reactive Protein , Percutaneous Coronary Intervention , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Prevalence , Prognosis , Risk Factors , Treatment Outcome
11.
J Cardiovasc Magn Reson ; 23(1): 45, 2021 04 05.
Article in English | MEDLINE | ID: mdl-33823860

ABSTRACT

AIMS: To compare the ability of left ventricular (LV) and right ventricular (RV) strain measured by fast-strain encoded cardiovascular magnetic resonance (CMR) (fast-SENC) with LV- and RV-ejection fraction for the diagnostic classification of patients with different stages of chronic heart failure (stages A-D based on American College of Cardiology/American Heart Association guidelines) due to non-ischemic cardiomyopathies. METHODS: Our study population consisted of 276 consecutive patients who underwent CMR for clinical reasons, and 19 healthy subjects. Wall motion score index and non-infarct related late gadolinium enhancement (LGE), LV ejection fraction (LVEF) and RV ejection fraction (RVEF) and global LV- and RV-longitudinal (GLS) and circumferential strain (GCS) based on fast-SENC acquisitions, were calculated in all subjects. The percentage of LV and RV myocardial segments with strain ≤ - 17% (%normal LV and RV myocardium) was determined in all subjects. RESULTS: LVEF and RVEF, LV-GLS, LV-GCS, RV-GLS, RV-GCS and %normal LV- and RV myocardium depressed with increasing heart failure stage (p < 0.001 for all by ANOVA). By multivariable analysis, %normal LV and RV myocardium exhibited closer associations to heart failure stages than LVEF and RVEF (rpartial = 0.79 versus rpartial = 0.21 for %normal LV myocardium versus LVEF and rpartial = 0.64 versus rpartial = 0.20 for %normal RV myocardium versus RVEF, respectively). Furthermore, %normal LV and RV myocardium exhibited incremental value for the identification of patients (i) with subclinical myocardial dysfunction and (ii) with symptomatic heart failure, surpassing that provided by LVEF and RVEF (ΔAUC = 0.22 for LVEF and ΔAUC = 0.19 for RVEF with subclinical dysfunction, and ΔAUC = 0.19 for LVEF and ΔAUC = 0.22 for RVEF with symptomatic heart failure, respectively, p < 0.001 for all). %normal LV myocardium reclassified 11 of 31 (35%) patients judged as having no structural heart disease by clinical and imaging data to stage B, i.e., subclinical LV-dysfunction. CONCLUSIONS: In patients with non-ischemic cardiomyopathy, %normal LV and RV myocardium, by fast-SENC, enables improved identification of asymptomatic patients with subclinical LV-dysfunction. This technique may be useful for the early identification of such presumably healthy subjects at risk for heart failure and for monitoring LV and RV deformation during pharmacologic interventions in future studies.


Subject(s)
Amyloidosis/diagnostic imaging , Cardiomyopathy, Dilated/diagnostic imaging , Cardiomyopathy, Hypertrophic/diagnostic imaging , Heart Failure/diagnostic imaging , Magnetic Resonance Imaging, Cine , Stroke Volume , Ventricular Function, Left , Ventricular Function, Right , Adult , Aged , Aged, 80 and over , Amyloidosis/complications , Amyloidosis/physiopathology , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/physiopathology , Case-Control Studies , Early Diagnosis , Female , Heart Failure/etiology , Heart Failure/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Risk Assessment , Risk Factors , Young Adult
12.
J Cardiovasc Magn Reson ; 23(1): 92, 2021 07 12.
Article in English | MEDLINE | ID: mdl-34247623

ABSTRACT

AIM: To evaluate the ability of single heartbeat fast-strain encoded (SENC) cardiovascular magnetic resonance (CMR) derived myocardial strain to discriminate between different forms of left ventricular (LV) hypertrophy (LVH). METHODS: 314 patients (228 with hypertensive heart disease (HHD), 45 with hypertrophic cardiomyopathy (HCM), 41 with amyloidosis, 22 competitive athletes, and 33 healthy controls) were systematically analysed. LV ejection fraction (LVEF), LV mass index and interventricular septal (IVS) thickness, T1 mapping and atypical late gadolinium enhancement (LGE) were assessed. In addition, the percentage of LV myocardial segments with strain ≤ - 17% (%normal myocardium) was determined. RESULTS: Patients with amyloidosis and HCM exhibited the highest IVS thickness (17.4 ± 3.3 mm and 17.4 ± 6 mm, respectively, p < 0.05 vs. all other groups), whereas patients with amyloidosis showed the highest LV mass index (95.1 ± 20.1 g/m2, p < 0.05 vs all others) and lower LVEF compared to controls (50.5 ± 9.8% vs 59.2 ± 5.5%, p < 0.05). Analysing subjects with mild to moderate hypertrophy (IVS 11-15 mm), %normal myocardium exhibited excellent and high precision, respectively for the differentiation between athletes vs. HCM (sensitivity and specificity = 100%, Area under the curve; AUC%normalmyocardium = 1.0, 95%CI = 0.85-1.0) and athletes vs. HHD (sensitivity = 83%, specificity = 75%, AUC%normalmyocardium = 0.85, 95%CI = 0.78-0.90). Combining %normal myocardial strain with atypical LGE provided high accuracy also for the differentiation of HHD vs. HCM (sensitivity = 82%, specificity = 100%, AUCcombination = 0.92, 95%CI = 0.88-0.95) and HCM vs. amyloidosis (sensitivity = 83%, specificity = 100%, AUCcombination = 0.83, 95%CI = 0.60-0.96). CONCLUSION: Fast-SENC derived myocardial strain is a valuable tool for differentiating between athletes vs. HCM and athletes vs. HHD. Combining strain and LGE data is useful for differentiating between HHD vs. HCM and HCM vs. cardiac amyloidosis.


Subject(s)
Contrast Media , Gadolinium , Humans , Hypertrophy, Left Ventricular/diagnostic imaging , Magnetic Resonance Spectroscopy , Predictive Value of Tests
13.
J Cardiovasc Magn Reson ; 23(1): 60, 2021 05 17.
Article in English | MEDLINE | ID: mdl-34001175

ABSTRACT

BACKGROUND: Myocardial deformation analyses using cardiovascular magnetic resonance (CMR) feature tracking (CMR-FT) have incremental value in the assessment of cardiac function beyond volumetric analyses. Since guidelines do not recommend specific imaging parameters, we aimed to define optimal spatial and temporal resolutions for CMR cine images to enable reliable post-processing. METHODS: Intra- and inter-observer reproducibility was assessed in 12 healthy subjects and 9 heart failure (HF) patients. Cine images were acquired with different temporal (20, 30, 40 and 50 frames/cardiac cycle) and spatial resolutions (high in-plane 1.5 × 1.5 mm through-plane 5 mm, standard 1.8 × 1.8 x 8mm and low 3.0 × 3.0 x 10mm). CMR-FT comprised left ventricular (LV) global and segmental longitudinal/circumferential strain (GLS/GCS) and associated systolic strain rates (SR), and right ventricular (RV) GLS. RESULTS: Temporal but not spatial resolution did impact absolute strain and SR. Maximum absolute changes between lowest and highest temporal resolution were as follows: 1.8% and 0.3%/s for LV GLS and SR, 2.5% and 0.6%/s for GCS and SR as well as 1.4% for RV GLS. Changes of strain values occurred comparing 20 and 30 frames/cardiac cycle including LV and RV GLS and GCS (p < 0.001-0.046). In contrast, SR values (LV GLS/GCS SR) changed significantly comparing all successive temporal resolutions (p < 0.001-0.013). LV strain and SR reproducibility was not affected by either temporal or spatial resolution, whilst RV strain variability decreased with augmentation of temporal resolution. CONCLUSION: Temporal but not spatial resolution significantly affects strain and SR in CMR-FT deformation analyses. Strain analyses require lower temporal resolution and 30 frames/cardiac cycle offer consistent strain assessments, whilst SR measurements gain from further increases in temporal resolution.


Subject(s)
Heart Ventricles , Magnetic Resonance Imaging, Cine , Heart Ventricles/diagnostic imaging , Humans , Magnetic Resonance Imaging , Predictive Value of Tests , Reproducibility of Results , Ventricular Function, Left
14.
Internist (Berl) ; 62(11): 1141-1152, 2021 Nov.
Article in German | MEDLINE | ID: mdl-34613426

ABSTRACT

Heart failure with preserved ejection fraction (HFpEF) is a heterogeneous syndrome with diverse underlying etiologies and pathophysiological factors. Obesity and type 2 diabetes mellitus (T2DM), diseases which frequently coexist, induce a cluster of metabolic and nonmetabolic signaling derangements, which promote induction of inflammation, fibrosis and myocyte stiffness, all representing hallmarks of HFpEF. In contrast to other HFpEF risk factors, obesity and T2DM are often associated with the formation of an enlarged visceral adipose tissue (VAT), which is a highly active endocrine organ that can sustainably exacerbate inflammation and fibrotic remodeling of myocardial, renal, and vascular tissues via various paracrine and vasocrine signals. An abnormally large epicardial adipose tissue (EAT) thus not only causes a mechanical constriction of the diastolic filling procedure of the heart but is also associated with an increased release of proinflammatory adipokines that trigger atrial fibrillation and impaired left ventricular contraction parameters. Obese patients with HFpEF therefore belong to a unique HFpEF phenotype with a particularly poor prognosis that could benefit from an EAT-oriented phenotype-specific intervention. In addition to statins and antidiabetic drugs such as metformin, glucagon-like peptide­1 (GLP-1) receptor agonists and sodium-glucose transporter 2 (SGLT-2) inhibitors could also play an important role.


Subject(s)
Atrial Fibrillation , Diabetes Mellitus, Type 2 , Heart Failure , Heart Failure/diagnosis , Humans , Intra-Abdominal Fat , Stroke Volume
15.
J Magn Reson Imaging ; 52(6): 1732-1742, 2020 12.
Article in English | MEDLINE | ID: mdl-32557923

ABSTRACT

BACKGROUND: Adenosine stress MRI is well established for the evaluation of known and suspected coronary artery disease. However, a proportion of patients might be "under-stressed" using the standard adenosine dose. PURPOSE: To compare three different adenosine dosages for stress MRI in terms of stress adequacy based on splenic switch-off (SSO) and limiting side effects. STUDY TYPE: Prospective. POPULATION: In all, 100 patients were randomized in group 1 (33 pts), group 2 (34 pts), and group 3 (33 pts), receiving dosages of 140 µg/kg/min, 175 µg/kg/min, or 210 µg/kg/min, respectively. SSO was evaluated visually and quantitatively. SEQUENCE: Stress perfusion was performed using a 1.5T scanner in three short axes using a standard single-shot, saturation recovery gradient-echo sequence. ASSESSMENT: Three blinded experienced operators evaluated SSO on stress and rest perfusion acquisitions in the three groups. The signal intensity of the spleen and myocardium and the presence of inducible ischemia and late gadolinium enhancement were assessed. STATISTICAL ANALYSIS: T-test, analysis of variance (ANOVA), chi-squared test, and Pearson's correlation coefficient. RESULTS: SSO was present more frequently in patients receiving 175 µg/kg/min and 210 µg/kg/min (31/33 [94%] and 27/29 [93%], respectively) compared to those receiving the standard dose (19/33 [58%], P < 0.05). A positive stress result was noted in 3/33 (9%) patients receiving 140 µg/kg/min vs. 9/33 (27%) patients receiving 175 µg/kg/min and 10/31 (33%) patients receiving 210 µg/kg/min (P < 0.05 for all, P < 0.05 for group 1 vs. groups 2, 3). The relative decrease of splenic signal intensity at hyperemia vs. baseline was significantly lower in group 1 compared to groups 2 and 3 (-33% vs. -54%, -56%, respectively; P < 0.05). No adverse events during scanning were noted in groups 1 and 2, whereas in group 3 four examinations were stopped due to severe dyspnea (n = 2) and AV-blockage (n = 2). DATA CONCLUSION: A dosage of 175 µg/kg/min adenosine results in a higher proportion of SSO, which may be an indirect marker of adequate coronary vasodilatation and simultaneously offers similar safety compared to the standard 140 µg/kg/min dosage. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2 J. MAGN. RESON. IMAGING 2020;52:1732-1742.


Subject(s)
Coronary Artery Disease , Myocardial Perfusion Imaging , Adenosine , Contrast Media/pharmacology , Coronary Circulation , Gadolinium/pharmacology , Humans , Magnetic Resonance Imaging , Patient Safety , Prospective Studies , Spleen/diagnostic imaging , Vasodilator Agents/pharmacology
16.
J Cardiovasc Magn Reson ; 22(1): 51, 2020 07 23.
Article in English | MEDLINE | ID: mdl-32698811

ABSTRACT

BACKGROUND: Right ventricular (RV) strain is a useful predictor of prognosis in various cardiovascular diseases, including those traditionally believed to impact only the left ventricle. We aimed to determine inter-modality and inter-technique agreement in RV longitudinal strain (LS) measurements between currently available cardiovascular magnetic resonance (CMR) and echocardiographic techniques, as well as their reproducibility and the impact of layer-specific strain measurements. METHODS: RV-LS was determined in 62 patients using 2D speckle tracking echocardiography (STE, Epsilon) and two CMR techniques: feature tracking (FT) and strain-encoding (SENC), and in 17 healthy subjects using FT and SENC only. Measurements included global and free-wall LS (GLS, FWLS). Inter-technique agreement was assessed using linear regression and Bland-Altman analysis. Reproducibility was quantified using intraclass correlation (ICC) and coefficients of variation (CoV). RESULTS: We found similar moderate agreement between both CMR techniques and STE in patients: r = 0.57-0.63 for SENC; r = 0.50-0.62 for FT. The correlation between SENC and STE was better for GLS (r = 0.63) than for FWLS (r = 0.57). Conversely, the correlation between FT and STE was higher for FWLS (r = 0.60-0.62) than GLS (r = 0.50-0.54). FT-midmyocardial strain correlated better with SENC and STE than FT-subendocardial strain. The agreement between SENC and FT was fair (r = 0.36-0.41, bias: - 6.4 to - 10.4%) in the entire study group. All techniques except FT showed excellent reproducibility (ICC: 0.62-0.96, CoV: 0.04-0.30). CONCLUSIONS: We found only moderate inter-modality agreement with STE in RV-LS for both FT and SENC and poor agreement when comparing between the CMR techniques. Different modalities and techniques should not be used interchangeably to determine and monitor RV strain.


Subject(s)
Echocardiography/methods , Magnetic Resonance Imaging/methods , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/physiopathology , Adult , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Young Adult
17.
J Cardiovasc Magn Reson ; 22(1): 61, 2020 09 03.
Article in English | MEDLINE | ID: mdl-32878639

ABSTRACT

The aim of this document is to provide specific recommendations on the use of cardiovascular magnetic resonance (CMR) protocols in the era of the COVID-19 pandemic. In patients without COVID-19, standard CMR protocols should be used based on clinical indication as usual. Protocols used in patients who have known / suspected active COVID-19 or post COVID-19 should be performed based on the specific clinical question with an emphasis on cardiac function and myocardial tissue characterization. Short and dedicated protocols are recommended.


Subject(s)
Cardiovascular Diseases/diagnostic imaging , Coronavirus Infections/prevention & control , Infection Control/organization & administration , Magnetic Resonance Imaging, Cine/standards , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Practice Guidelines as Topic , COVID-19 , Coronavirus Infections/epidemiology , Female , Humans , Magnetic Resonance Imaging , Male , Pandemics/statistics & numerical data , Pneumonia, Viral/epidemiology , Severity of Illness Index , Societies, Medical , United States
18.
J Cardiovasc Magn Reson ; 21(1): 46, 2019 08 08.
Article in English | MEDLINE | ID: mdl-31391036

ABSTRACT

OBJECTIVES: We sought to: (1) determine the agreement in cardiovascular magnetic resonance (CMR) and speckle tracking echocardiography (STE) derived strain measurements, (2) compare their reproducibility, (3) determine which approach is best related to CMR late gadolinium enhancement (LGE). BACKGROUND: While STE-derived strain is routinely used to assess left ventricular (LV) function, CMR strain measurements are not yet standardized. Strain can be measured using dedicated pulse sequences (strain-encoding, SENC), or post-processing of cine images (feature tracking, FT). It is unclear whether these measurements are interchangeable, and whether strain can be used as an alternative to LGE. METHODS: Fifty patients underwent 2D echocardiography and 1.5 T CMR. Global longitudinal strain (GLS) was measured by STE (Epsilon), FT (NeoSoft) and SENC (Myocardial Solutions) and circumferential strain (GCS) by FT and SENC. RESULTS: GLS showed good inter-modality agreement (r-values: 0.71-0.75), small biases (< 1%) but considerable limits of agreement (- 7 to 8%). The agreement between the CMR techniques was better for GLS than GCS (r = 0.81 vs 0.67; smaller bias). Repeated measurements showed low intra- and inter-observer variability for both GLS and GCS (intraclass correlations 0.86-0.99; coefficients of variation 3-13%). LGE was present in 22 (44%) of patients. Both SENC- and FT-derived GLS and GCS were associated with LGE, while STE-GLS was not. Irrespective of CMR technique, this association was stronger for GCS (AUC 0.77-0.78) than GLS (AUC 0.67-0.72) and STE-GLS (AUC = 0.58). CONCLUSION: There is good inter-technique agreement in strain measurements, which were highly reproducible, irrespective of modality or analysis technique. GCS may better reflect the presence of underlying LGE than GLS.


Subject(s)
Echocardiography , Heart Ventricles/diagnostic imaging , Magnetic Resonance Imaging, Cine , Myocardial Contraction , Myocardial Ischemia/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left , Adult , Female , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Multimodal Imaging , Myocardial Ischemia/physiopathology , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Stroke Volume , Ventricular Dysfunction, Left/physiopathology
19.
Europace ; 21(11): 1678-1685, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31322701

ABSTRACT

AIMS: There have been no published studies on the safety of magnetic resonance imaging (MRI) at 3 Tesla (3 T) in patients with MRI-conditional implantable cardioverter-defibrillators (ICDs). The aim of this study was to assess clinical safety of the Biotronik ProMRI ICD system during non-diagnostic head and lower lumbar scans under 3 T MRI conditions. METHODS AND RESULTS: The study enrolled 129 patients at 12 sites in Australia, Singapore, and Europe. Predefined head and lower lumbar MR scans (total duration ≈30 min) were performed in 112 patients. Three primary endpoints were evaluated from the pre-MRI to the 1-month post-MRI visit: (i) freedom from serious adverse device effects (SADEs) related to MRI (hypothesized to be >90%); (ii) pacing threshold invariance for all leads (geometric mean of the patient-wise ratios for 1 month vs. pre-MRI was hypothesized to be <1.07); and (iii) sensing amplitude invariance (geometric mean of the ratios was hypothesized to be >0.993). No MRI-related SADE occurred (SADE-free rate 100%, 95% confidence interval 95.98-100%). Pacing threshold and sensing amplitudes fulfilled the invariance hypotheses with high statistical significance (P < 0.0013). No threshold increase >0.5 V or sensing amplitude decrease by >50% was observed (secondary endpoints). Lead impedances, battery capacity, and detection and treatment of arrhythmias by ICDs were not affected by MRI scans. CONCLUSION: The head and lower lumbar scans under specific 3 T MRI conditions were safe in the investigated MR-conditional ICD systems. There was no evidence of harm to the patients or any negative influence of the MRI scan on the implanted systems.


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable , Head/diagnostic imaging , Heart Rate/physiology , Lumbar Vertebrae/diagnostic imaging , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/physiopathology , Equipment Design , Equipment Safety , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies
20.
BMC Cardiovasc Disord ; 19(1): 52, 2019 03 05.
Article in English | MEDLINE | ID: mdl-30836942

ABSTRACT

BACKGROUND: Recently introduced fast strain-encoded (SENC) cardiac magnetic resonance (CMR) imaging (fast-SENC) provides real-time acquisition of myocardial performance in a single heartbeat. We aimed to test the ability and accuracy of real-time strain-encoded CMR imaging to estimate left ventricular volumes, ejection fraction and mass. METHODS: Thirty-five subjects (12 healthy volunteers and 23 patients with known or suspected coronary artery disease) were investigated. All study participants were imaged at 1.5 Tesla MRI scanner (Achieva, Philips) using an advanced CMR study protocol which included conventional cine and fast-SENC imaging. A newly developed real-time free-breathing SENC imaging technique based on the acquisition of two images with different frequency modulation was employed. RESULTS: All parameters were successfully derived from fast-SENC images with total study time of 105 s (a 15 s scan time and a 90 s post-processing time). There was no significant difference between fast-SENC and cine imaging in the estimation of LV volumes and EF, whereas fast-SENC underestimated LV end-diastolic mass by 7%. CONCLUSION: The single heartbeat fast-SENC technique can be used as a good alternative to cine imaging for the precise calculation of LV volumes and ejection fraction while the technique significantly underestimates LV end-diastolic mass.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Magnetic Resonance Imaging, Cine , Stroke Volume , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left , Adult , Aged , Case-Control Studies , Coronary Artery Disease/physiopathology , Female , Heart Rate , Humans , Male , Middle Aged , Observer Variation , Pilot Projects , Predictive Value of Tests , Reproducibility of Results , Time Factors , Ventricular Dysfunction, Left/physiopathology , Workflow , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL