Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 200
Filter
Add more filters

Country/Region as subject
Publication year range
1.
N Engl J Med ; 388(11): 991-1001, 2023 Mar 16.
Article in English | MEDLINE | ID: mdl-36920756

ABSTRACT

BACKGROUND: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear. METHODS: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes. RESULTS: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.).


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Child , Child, Preschool , Humans , Blood Glucose/analysis , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/drug therapy , Glycated Hemoglobin/analysis , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/adverse effects , Hypoglycemic Agents/therapeutic use , Insulin/administration & dosage , Insulin/adverse effects , Insulin/therapeutic use , Insulin Infusion Systems/adverse effects
2.
N Engl J Med ; 389(17): 1566-1578, 2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37796241

ABSTRACT

BACKGROUND: Hybrid closed-loop insulin therapy has shown promise for management of type 1 diabetes during pregnancy; however, its efficacy is unclear. METHODS: In this multicenter, controlled trial, we randomly assigned pregnant women with type 1 diabetes and a glycated hemoglobin level of at least 6.5% at nine sites in the United Kingdom to receive standard insulin therapy or hybrid closed-loop therapy, with both groups using continuous glucose monitoring. The primary outcome was the percentage of time in the pregnancy-specific target glucose range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]) as measured by continuous glucose monitoring from 16 weeks' gestation until delivery. Analyses were performed according to the intention-to-treat principle. Key secondary outcomes were the percentage of time spent in a hyperglycemic state (glucose level >140 mg per deciliter), overnight time in the target range, the glycated hemoglobin level, and safety events. RESULTS: A total of 124 participants with a mean (±SD) age of 31.1±5.3 years and a mean baseline glycated hemoglobin level of 7.7±1.2% underwent randomization. The mean percentage of time that the maternal glucose level was in the target range was 68.2±10.5% in the closed-loop group and 55.6±12.5% in the standard-care group (mean adjusted difference, 10.5 percentage points; 95% confidence interval [CI], 7.0 to 14.0; P<0.001). Results for the secondary outcomes were consistent with those of the primary outcome; participants in the closed-loop group spent less time in a hyperglycemic state than those in the standard-care group (difference, -10.2 percentage points; 95% CI, -13.8 to -6.6); had more overnight time in the target range (difference, 12.3 percentage points; 95% CI, 8.3 to 16.2), and had lower glycated hemoglobin levels (difference, -0.31 percentage points; 95% CI, -0.50 to -0.12). Little time was spent in a hypoglycemic state. No unanticipated safety problems associated with the use of closed-loop therapy during pregnancy occurred (6 instances of severe hypoglycemia, vs. 5 in the standard-care group; 1 instance of diabetic ketoacidosis in each group; and 12 device-related adverse events in the closed-loop group, 7 related to closed-loop therapy). CONCLUSIONS: Hybrid closed-loop therapy significantly improved maternal glycemic control during pregnancy complicated by type 1 diabetes. (Funded by the Efficacy and Mechanism Evaluation Program; AiDAPT ISRCTN Registry number, ISRCTN56898625.).


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Pregnancy in Diabetics , Adult , Female , Humans , Pregnancy , Blood Glucose/analysis , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 1/drug therapy , Glycated Hemoglobin/analysis , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/adverse effects , Hypoglycemic Agents/therapeutic use , Insulin/administration & dosage , Insulin/adverse effects , Insulin/therapeutic use , Insulin Infusion Systems/adverse effects , Pregnancy in Diabetics/blood , Pregnancy in Diabetics/drug therapy , Treatment Outcome
3.
N Engl J Med ; 386(3): 209-219, 2022 01 20.
Article in English | MEDLINE | ID: mdl-35045227

ABSTRACT

BACKGROUND: The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear. METHODS: In this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closed-loop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed. RESULTS: A total of 74 participants underwent randomization. The mean (±SD) age of the participants was 5.6±1.6 years, and the baseline glycated hemoglobin level was 7.3±0.7%. The percentage of time with the glucose level in the target range was 8.7 percentage points (95% confidence interval [CI], 7.4 to 9.9) higher during the closed-loop period than during the control period (P<0.001). The mean adjusted difference (closed-loop minus control) in the percentage of time spent in a hyperglycemic state was -8.5 percentage points (95% CI, -9.9 to -7.1), the difference in the glycated hemoglobin level was -0.4 percentage points (95% CI, -0.5 to -0.3), and the difference in the mean sensor glucose level was -12.3 mg per deciliter (95% CI, -14.8 to -9.8) (P<0.001 for all comparisons). The time spent in a hypoglycemic state was similar with the two treatments (P = 0.74). The median time spent in the closed-loop mode was 95% (interquartile range, 92 to 97) over the 16-week closed-loop period. One serious adverse event of severe hypoglycemia occurred during the closed-loop period. One serious adverse event that was deemed to be unrelated to treatment occurred. CONCLUSIONS: A hybrid closed-loop system significantly improved glycemic control in very young children with type 1 diabetes, without increasing the time spent in hypoglycemia. (Funded by the European Commission and others; ClinicalTrials.gov number, NCT03784027.).


Subject(s)
Diabetes Mellitus, Type 1/drug therapy , Glycemic Control/instrumentation , Hypoglycemic Agents/administration & dosage , Insulin Infusion Systems , Insulin/administration & dosage , Pancreas, Artificial , Algorithms , Blood Glucose/analysis , Child , Child, Preschool , Cross-Over Studies , Equipment Design , Female , Glycated Hemoglobin/analysis , Glycemic Control/methods , Humans , Hyperglycemia/diagnosis , Infant , Male
4.
Clin Diabetes ; 42(1): 116-124, 2024.
Article in English | MEDLINE | ID: mdl-38230336

ABSTRACT

The t:slim X2 insulin pump with Control-IQ technology (Control-IQ) advanced hybrid closed-loop automated insulin delivery system was evaluated in this prospective single-arm trial. Thirty adults with type 2 diabetes using the Control-IQ system showed substantial glycemic improvement with no increase in hypoglycemia. Mean time in range (70-180 mg/dL) improved 15%, representing an increase of 3.6 hours/day, and mean glucose decreased by 22 mg/dL.

5.
Telemed J E Health ; 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39166322

ABSTRACT

Background: The objective was to examine patient-reported outcomes (PROs) associated with access to a virtual clinic model for diabetes care. Methods: Adults with diabetes (N = 234) received virtual care, including support for continuous glucose monitoring (CGM) over a 6-month study period. Care was led by a Certified Diabetes Care and Education Specialist and focused on optimizing self-management skills and response to glucose values observed on CGM. After 6 months of CGM use and access to diabetes education, participants could opt in to another 6 months of follow-up with access to the virtual care team. Participants completed PRO surveys and had health and glycemic measures collected at baseline, 3, 6, and 12 months. Results: Participants with type 1 diabetes (N = 160) were 44 ± 14 years and had mean baseline HbA1c of 61 mmol/mol (7.7%). Participants with type 2 diabetes (N = 74) were 52 ± 12 years and had mean baseline HbA1c of 66 mmol/mol (8.2%). Compared with baseline levels, at 6 months participants experienced less depression, diabetes distress, and hypoglycemic fears while also experiencing greater satisfaction with glucose monitoring, diabetes technology and specifically with CGM, and confidence for managing hypoglycemic (p < 0.05). For participants with type 1 diabetes, more time in the target range for glucose levels (70-180 mg/dL) was associated with less depression, diabetes distress, and hypoglycemic fears. Conclusions: PROs improved for adults with diabetes utilizing virtual diabetes care, including support for CGM use. Paired with the glycemic improvements observed in this virtual clinic study, there were robust benefits on the quality of life of adults with diabetes. ClinicalTrials.gov Identifier: NCT04765358.

6.
N Engl J Med ; 383(9): 836-845, 2020 08 27.
Article in English | MEDLINE | ID: mdl-32846062

ABSTRACT

BACKGROUND: A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes. METHODS: In a 16-week, multicenter, randomized, open-label, parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. RESULTS: A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points [equivalent to 2.6 hours per day]; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group. CONCLUSIONS: In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).


Subject(s)
Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/administration & dosage , Infusion Pumps, Implantable , Insulin Infusion Systems , Insulin/administration & dosage , Adolescent , Blood Glucose/analysis , Child , Diabetes Mellitus, Type 1/blood , Diabetic Ketoacidosis/etiology , Female , Glycated Hemoglobin/analysis , Humans , Hypoglycemia/chemically induced , Hypoglycemic Agents/adverse effects , Injections, Subcutaneous , Insulin/adverse effects , Insulin Infusion Systems/adverse effects , Male , Pancreas, Artificial
7.
JAMA ; 329(12): 980-989, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36826834

ABSTRACT

Importance: Near normalization of glucose levels instituted immediately after diagnosis of type 1 diabetes has been postulated to preserve pancreatic beta cell function by reducing glucotoxicity. Previous studies have been hampered by an inability to achieve tight glycemic goals. Objective: To determine the effectiveness of intensive diabetes management to achieve near normalization of glucose levels on preservation of pancreatic beta cell function in youth with newly diagnosed type 1 diabetes. Design, Setting, and Participants: This randomized, double-blind, clinical trial was conducted at 6 centers in the US (randomizations from July 20, 2020, to October 13, 2021; follow-up completed September 15, 2022) and included youths with newly diagnosed type 1 diabetes aged 7 to 17 years. Interventions: Random assignment to intensive diabetes management, which included use of an automated insulin delivery system (n = 61), or standard care, which included use of a continuous glucose monitor (n = 52), as part of a factorial design in which participants weighing 30 kg or more also were assigned to receive either oral verapamil or placebo. Main Outcomes and Measures: The primary outcome was mixed-meal tolerance test-stimulated C-peptide area under the curve (a measure of pancreatic beta cell function) 52 weeks from diagnosis. Results: Among 113 participants (mean [SD] age, 11.8 [2.8] years; 49 females [43%]; mean [SD] time from diagnosis to randomization, 24 [5] days), 108 (96%) completed the trial. The mean C-peptide area under the curve decreased from 0.57 pmol/mL at baseline to 0.45 pmol/mL at 52 weeks in the intensive management group, and from 0.60 to 0.50 pmol/mL in the standard care group (treatment group difference, -0.01 [95% CI, -0.11 to 0.10]; P = .89). The mean time in the target range of 70 to 180 mg/dL, measured with continuous glucose monitoring, at 52 weeks was 78% in the intensive management group vs 64% in the standard care group (adjusted difference, 16% [95% CI, 10% to 22%]). One severe hypoglycemia event and 1 diabetic ketoacidosis event occurred in each group. Conclusions and Relevance: In youths with newly diagnosed type 1 diabetes, intensive diabetes management, which included automated insulin delivery, achieved excellent glucose control but did not affect the decline in pancreatic C-peptide secretion at 52 weeks. Trial Registration: ClinicalTrials.gov Identifier: NCT04233034.


Subject(s)
Diabetes Mellitus, Type 1 , Insulin-Secreting Cells , Female , Adolescent , Humans , Child , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/adverse effects , Hypoglycemic Agents/administration & dosage , Blood Glucose/drug effects , Insulin-Secreting Cells/drug effects , C-Peptide/pharmacology , C-Peptide/therapeutic use , Double-Blind Method , Glycemic Control , Blood Glucose Self-Monitoring , Glycated Hemoglobin , Insulin/adverse effects , Insulin/administration & dosage
8.
JAMA ; 329(12): 990-999, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36826844

ABSTRACT

Importance: In preclinical studies, thioredoxin-interacting protein overexpression induces pancreatic beta cell apoptosis and is involved in glucotoxicity-induced beta cell death. Calcium channel blockers reduce these effects and may be beneficial to beta cell preservation in type 1 diabetes. Objective: To determine the effect of verapamil on pancreatic beta cell function in children and adolescents with newly diagnosed type 1 diabetes. Design, Setting, and Participants: This double-blind, randomized clinical trial including children and adolescents aged 7 to 17 years with newly diagnosed type 1 diabetes who weighed 30 kg or greater was conducted at 6 centers in the US (randomized participants between July 20, 2020, and October 13, 2021) and follow-up was completed on September 15, 2022. Interventions: Participants were randomly assigned 1:1 to once-daily oral verapamil (n = 47) or placebo (n = 41) as part of a factorial design in which participants also were assigned to receive either intensive diabetes management or standard diabetes care. Main Outcomes and Measures: The primary outcome was area under the curve values for C-peptide level (a measure of pancreatic beta cell function) stimulated by a mixed-meal tolerance test at 52 weeks from diagnosis of type 1 diabetes. Results: Among 88 participants (mean age, 12.7 [SD, 2.4] years; 36 were female [41%]; and the mean time from diagnosis to randomization was 24 [SD, 4] days), 83 (94%) completed the trial. In the verapamil group, the mean C-peptide area under the curve was 0.66 pmol/mL at baseline and 0.65 pmol/mL at 52 weeks compared with 0.60 pmol/mL at baseline and 0.44 pmol/mL at 52 weeks in the placebo group (adjusted between-group difference, 0.14 pmol/mL [95% CI, 0.01 to 0.27 pmol/mL]; P = .04). This equates to a 30% higher C-peptide level at 52 weeks with verapamil. The percentage of participants with a 52-week peak C-peptide level of 0.2 pmol/mL or greater was 95% (41 of 43 participants) in the verapamil group vs 71% (27 of 38 participants) in the placebo group. At 52 weeks, hemoglobin A1c was 6.6% in the verapamil group vs 6.9% in the placebo group (adjusted between-group difference, -0.3% [95% CI, -1.0% to 0.4%]). Eight participants (17%) in the verapamil group and 8 participants (20%) in the placebo group had a nonserious adverse event considered to be related to treatment. Conclusions and Relevance: In children and adolescents with newly diagnosed type 1 diabetes, verapamil partially preserved stimulated C-peptide secretion at 52 weeks from diagnosis compared with placebo. Further studies are needed to determine the longitudinal durability of C-peptide improvement and the optimal length of therapy. Trial Registration: ClinicalTrials.gov Identifier: NCT04233034.


Subject(s)
Diabetes Mellitus, Type 1 , Insulin-Secreting Cells , Adolescent , Humans , Child , Female , Male , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/therapeutic use , C-Peptide/metabolism , C-Peptide/pharmacology , C-Peptide/therapeutic use , Double-Blind Method , Verapamil/adverse effects , Insulin-Secreting Cells/drug effects
9.
N Engl J Med ; 381(18): 1707-1717, 2019 10 31.
Article in English | MEDLINE | ID: mdl-31618560

ABSTRACT

BACKGROUND: Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes. METHODS: In this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring. RESULTS: A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P<0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was >180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was <70 mg per deciliter or <54 mg per deciliter [3.0 mmol per liter]) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P<0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.).


Subject(s)
Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/administration & dosage , Insulin Infusion Systems , Insulin/administration & dosage , Pancreas, Artificial , Adolescent , Adult , Aged , Blood Glucose/analysis , Diabetes Mellitus, Type 1/blood , Equipment Design , Female , Glycated Hemoglobin/analysis , Humans , Hypoglycemic Agents/adverse effects , Insulin/adverse effects , Insulin Infusion Systems/adverse effects , Male , Middle Aged , Pancreas, Artificial/adverse effects , Young Adult
10.
Diabetes Obes Metab ; 24(12): 2309-2318, 2022 12.
Article in English | MEDLINE | ID: mdl-35837984

ABSTRACT

AIM: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. MATERIALS AND METHODS: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. RESULTS: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. CONCLUSIONS: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.


Subject(s)
Diabetes Mellitus, Type 1 , Adolescent , Humans , Child , Diabetes Mellitus, Type 1/drug therapy , Blood Glucose Self-Monitoring , Insulin/therapeutic use , Quality of Life , Hypoglycemic Agents/therapeutic use , Blood Glucose , Treatment Outcome , Insulin Infusion Systems , Parents/psychology
11.
Pediatr Diabetes ; 23(4): 439-446, 2022 06.
Article in English | MEDLINE | ID: mdl-35138021

ABSTRACT

Insulin is commonly used to reverse gluco-toxicity in youth with newly diagnosed type 2 diabetes (T2D), but many are subsequently weaned off insulin. We analyzed Pediatric Diabetes Consortium (PDC) data to determine how long glycemic control is maintained after termination of initial insulin treatment. Youth with T2D who had previously been on insulin but were on either an intensive lifestyle intervention alone or metformin alone upon enrollment in the PDC T2D Registry were studied (N = 183). The primary outcome was time to treatment failure, defined by need to restart insulin or metformin or another diabetes medication. Data were analyzed using logistic regression to assess risk factors for treatment failure. Of the 183 participants studied (mean age 15 years, diabetes duration 1.7 years), 54% experienced treatment failure (median follow-up time 1.7 years). In the subgroup on metformin monotherapy (N = 140), 45% subsequently required restart of insulin. Moreover, of participants in the subgroup treated with an intensive lifestyle intervention alone (N = 43), 81% restarted insulin or were treated with metformin or other diabetes medication. In both groups, median time to treatment failure was 1.2 years. Higher HbA1c at enrollment was significantly associated with treatment failure (p < 0.001). Youth with T2D who are initially treated with insulin have a high rate of treatment failure when switched to intensive lifestyle alone or metformin alone. Our data highlight the severe and progressive nature of youth onset T2D, hence patients should be monitored closely for deteriorating glycemic control after being weaned off insulin.


Subject(s)
Diabetes Mellitus, Type 2 , Metformin , Adolescent , Blood Glucose , Diabetes Mellitus, Type 2/drug therapy , Glycated Hemoglobin/analysis , Humans , Hypoglycemic Agents/adverse effects , Insulin/adverse effects , Metformin/therapeutic use , Treatment Failure
12.
BMC Pregnancy Childbirth ; 22(1): 282, 2022 Apr 05.
Article in English | MEDLINE | ID: mdl-35382796

ABSTRACT

BACKGROUND: Pregnant women with type 1 diabetes strive for tight glucose targets (3.5-7.8 mmol/L) to minimise the risks of obstetric and neonatal complications. Despite using diabetes technologies including continuous glucose monitoring (CGM), insulin pumps and contemporary insulin analogues, most women struggle to achieve and maintain the recommended pregnancy glucose targets. This study aims to evaluate whether the use of automated closed-loop insulin delivery improves antenatal glucose levels in pregnant women with type 1 diabetes. METHODS/DESIGN: A multicentre, open label, randomized, controlled trial of pregnant women with type 1 diabetes and a HbA1c of ≥48 mmol/mol (6.5%) at pregnancy confirmation and ≤ 86 mmol/mol (10%) at randomization. Participants who provide written informed consent before 13 weeks 6 days gestation will be entered into a run-in phase to collect 96 h (24 h overnight) of CGM glucose values. Eligible participants will be randomized on a 1:1 basis to CGM (Dexcom G6) with usual insulin delivery (control) or closed-loop (intervention). The closed-loop system includes a model predictive control algorithm (CamAPS FX application), hosted on an android smartphone that communicates wirelessly with the insulin pump (Dana Diabecare RS) and CGM transmitter. Research visits and device training will be provided virtually or face-to-face in conjunction with 4-weekly antenatal clinic visits where possible. Randomization will stratify for clinic site. One hundred twenty-four participants will be recruited. This takes into account 10% attrition and 10% who experience miscarriage or pregnancy loss. Analyses will be performed according to intention to treat. The primary analysis will evaluate the change in the time spent in the target glucose range (3.5-7.8 mmol/l) between the intervention and control group from 16 weeks gestation until delivery. Secondary outcomes include overnight time in target, time above target (> 7.8 mmol/l), standard CGM metrics, HbA1c and psychosocial functioning and health economic measures. Safety outcomes include the number and severity of ketoacidosis, severe hypoglycaemia and adverse device events. DISCUSSION: This will be the largest randomized controlled trial to evaluate the impact of closed-loop insulin delivery during type 1 diabetes pregnancy. TRIAL REGISTRATION: ISRCTN 56898625 Registration Date: 10 April, 2018.


Subject(s)
Diabetes Mellitus, Type 1 , Blood Glucose/analysis , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/drug therapy , Female , Humans , Hypoglycemic Agents/therapeutic use , Infant, Newborn , Insulin/therapeutic use , Insulin Infusion Systems , Multicenter Studies as Topic , Pregnancy , Pregnant Women , Randomized Controlled Trials as Topic
13.
Lancet ; 392(10155): 1321-1329, 2018 10 13.
Article in English | MEDLINE | ID: mdl-30292578

ABSTRACT

BACKGROUND: The achievement of glycaemic control remains challenging for patients with type 1 diabetes. We assessed the effectiveness of day-and-night hybrid closed-loop insulin delivery compared with sensor-augmented pump therapy in people with suboptimally controlled type 1 diabetes aged 6 years and older. METHODS: In this open-label, multicentre, multinational, single-period, parallel randomised controlled trial, participants were recruited from diabetes outpatient clinics at four hospitals in the UK and two centres in the USA. We randomly assigned participants with type 1 diabetes aged 6 years and older treated with insulin pump and with suboptimal glycaemic control (glycated haemoglobin [HbA1c] 7·5-10·0%) to receive either hybrid closed-loop therapy or sensor-augmented pump therapy over 12 weeks of free living. Training on study insulin pump and continuous glucose monitoring took place over a 4-week run-in period. Eligible subjects were randomly assigned using central randomisation software. Allocation to the two study groups was unblinded, and randomisation was stratified within centre by low (<8·5%) or high (≥8·5%) HbA1c. The primary endpoint was the proportion of time that glucose concentration was within the target range of 3·9-10·0 mmol/L at 12 weeks post randomisation. Analyses of primary outcome and safety measures were done in all randomised patients. The trial is registered with ClinicalTrials.gov, number NCT02523131, and is closed to accrual. FINDINGS: From May 12, 2016, to Nov 17, 2017, 114 individuals were screened, and 86 eligible patients were randomly assigned to receive hybrid closed-loop therapy (n=46) or sensor-augmented pump therapy (n=40; control group). The proportion of time that glucose concentration was within the target range was significantly higher in the closed-loop group (65%, SD 8) compared with the control group (54%, SD 9; mean difference in change 10·8 percentage points, 95% CI 8·2 to 13·5; p<0·0001). In the closed-loop group, HbA1c was reduced from a screening value of 8·3% (SD 0·6) to 8·0% (SD 0·6) after the 4-week run-in, and to 7·4% (SD 0·6) after the 12-week intervention period. In the control group, the HbA1c values were 8·2% (SD 0·5) at screening, 7·8% (SD 0·6) after run-in, and 7·7% (SD 0·5) after intervention; reductions in HbA1c percentages were significantly greater in the closed-loop group compared with the control group (mean difference in change 0·36%, 95% CI 0·19 to 0·53; p<0·0001). The time spent with glucose concentrations below 3·9 mmol/L (mean difference in change -0·83 percentage points, -1·40 to -0·16; p=0·0013) and above 10·0 mmol/L (mean difference in change -10·3 percentage points, -13·2 to -7·5; p<0·0001) was shorter in the closed-loop group than the control group. The coefficient of variation of sensor-measured glucose was not different between interventions (mean difference in change -0·4%, 95% CI -1·4% to 0·7%; p=0·50). Similarly, total daily insulin dose was not different (mean difference in change 0·031 U/kg per day, 95% CI -0·005 to 0·067; p=0·09) and bodyweight did not differ (mean difference in change 0·68 kg, 95% CI -0·34 to 1·69; p=0·19). No severe hypoglycaemia occurred. One diabetic ketoacidosis occurred in the closed-loop group due to infusion set failure. Two participants in each study group had significant hyperglycaemia, and there were 13 other adverse events in the closed-loop group and three in the control group. INTERPRETATION: Hybrid closed-loop insulin delivery improves glucose control while reducing the risk of hypoglycaemia across a wide age range in patients with suboptimally controlled type 1 diabetes. FUNDING: JDRF, NIHR, and Wellcome Trust.


Subject(s)
Diabetes Mellitus, Type 1/drug therapy , Glycated Hemoglobin/analysis , Hypoglycemic Agents/administration & dosage , Infusion Pumps, Implantable , Insulin Infusion Systems , Insulin/administration & dosage , Adolescent , Adult , Blood Glucose Self-Monitoring , Child , Child, Preschool , Female , Humans , Hypoglycemia/prevention & control , Male , Young Adult
14.
Pediatr Diabetes ; 20(1): 99-106, 2019 02.
Article in English | MEDLINE | ID: mdl-30467929

ABSTRACT

OBJECTIVE: To evaluate the pattern of change in blood glucose concentrations and hypoglycemia risk in response to prolonged aerobic exercise in adolescents with type 1 diabetes (T1D) that had a wide range in pre-exercise blood glucose concentrations. METHODS: Individual blood glucose responses to prolonged (~60 minutes) moderate-intensity exercise were profiled in 120 youth with T1D. RESULTS: The mean pre-exercise blood glucose concentration was 178 ± 66 mg/dL, ranging from 69 to 396 mg/dL, while the mean change in glucose during exercise was -76 ± 55 mg/dL (mean ± SD), ranging from +83 to -257 mg/dL. Only 4 of 120 youth (3%) had stable glucose levels during exercise (ie, ± ≤10 mg/dL), while 4 (3%) had a rise in glucose >10 mg/dL, and the remaining (93%) had a clinically significant drop (ie, >10 mg/dL). A total of 53 youth (44%) developed hypoglycemia (≤70 mg/dL) during exercise. The change in glucose was negatively correlated with the pre-exercise glucose concentration (R2 = 0.44, P < 0.001), and tended to be greater in those on multiple daily insulin injections (MDI) vs continuous subcutaneous insulin infusion (CSII) (-98 ± 15 vs -65 ± 7 mg/dL, P = 0.05). No other collected variables appeared to predict the change in glucose including age, weight, height, body mass index, disease duration, daily insulin dose, HbA1c , or sex. CONCLUSION: Youth with T1D have variable glycemic responses to prolonged aerobic exercise, but this variability is partially explained by their pre-exercise blood glucose levels. When no implementation strategies are in place to limit the drop in glycemia, the incidence of exercise-associated hypoglycemia is ~44% and having a high pre-exercise blood glucose concentration is only marginally protective.


Subject(s)
Blood Glucose/metabolism , Diabetes Mellitus, Type 1/blood , Exercise/physiology , Hypoglycemia/etiology , Adolescent , Blood Glucose Self-Monitoring , Child , Cohort Studies , Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 1/drug therapy , Exercise Test , Female , Humans , Hyperglycemia/blood , Hyperglycemia/complications , Hypoglycemia/blood , Individuality , Insulin/administration & dosage , Insulin/adverse effects , Insulin Infusion Systems , Male , Retrospective Studies , Risk Factors
15.
Pediatr Diabetes ; 20(6): 794-799, 2019 09.
Article in English | MEDLINE | ID: mdl-31140654

ABSTRACT

OBJECTIVE: To evaluate the experiences of families with very young children aged 1 to 7 years (inclusive) with type 1 diabetes using day-and-night hybrid closed-loop insulin delivery. METHODS: Parents/caregivers of 20 children aged 1 to 7 years with type 1 diabetes completed a closed-loop experience survey following two 3-week periods of unrestricted day-and-night hybrid closed-loop insulin therapy using Cambridge FlorenceM system at home. Benefits, limitations, and improvements of closed-loop technology were explored. RESULTS: Responders reported reduced burden of diabetes management, less time spent managing diabetes, and improved quality of sleep with closed-loop. Ninety percent of the responders felt less worried about their child's glucose control using closed-loop. Size of study devices, battery performance and connectivity issues were identified as areas for improvement. Parents/caregivers wished for more options to input information to the system such as temporary glucose targets. CONCLUSIONS: Parents/caregivers of very young children reported important quality of life benefits associated with using closed-loop, supporting adoption of this technology in this population.


Subject(s)
Cost of Illness , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/drug therapy , Insulin Infusion Systems , Insulin/administration & dosage , Quality of Life , Blood Glucose/drug effects , Blood Glucose/metabolism , Blood Glucose Self-Monitoring , Caregivers/psychology , Caregivers/statistics & numerical data , Child , Child, Preschool , Circadian Rhythm/physiology , Cross-Over Studies , Diabetes Mellitus, Type 1/epidemiology , Diabetes Mellitus, Type 1/psychology , Family/psychology , Female , Humans , Infant , Insulin/adverse effects , Male , Parents/psychology , Surveys and Questionnaires
16.
Lancet ; 390(10110): 2347-2359, 2017 Nov 25.
Article in English | MEDLINE | ID: mdl-28923465

ABSTRACT

BACKGROUND: Pregnant women with type 1 diabetes are a high-risk population who are recommended to strive for optimal glucose control, but neonatal outcomes attributed to maternal hyperglycaemia remain suboptimal. Our aim was to examine the effectiveness of continuous glucose monitoring (CGM) on maternal glucose control and obstetric and neonatal health outcomes. METHODS: In this multicentre, open-label, randomised controlled trial, we recruited women aged 18-40 years with type 1 diabetes for a minimum of 12 months who were receiving intensive insulin therapy. Participants were pregnant (≤13 weeks and 6 days' gestation) or planning pregnancy from 31 hospitals in Canada, England, Scotland, Spain, Italy, Ireland, and the USA. We ran two trials in parallel for pregnant participants and for participants planning pregnancy. In both trials, participants were randomly assigned to either CGM in addition to capillary glucose monitoring or capillary glucose monitoring alone. Randomisation was stratified by insulin delivery (pump or injections) and baseline glycated haemoglobin (HbA1c). The primary outcome was change in HbA1c from randomisation to 34 weeks' gestation in pregnant women and to 24 weeks or conception in women planning pregnancy, and was assessed in all randomised participants with baseline assessments. Secondary outcomes included obstetric and neonatal health outcomes, assessed with all available data without imputation. This trial is registered with ClinicalTrials.gov, number NCT01788527. FINDINGS: Between March 25, 2013, and March 22, 2016, we randomly assigned 325 women (215 pregnant, 110 planning pregnancy) to capillary glucose monitoring with CGM (108 pregnant and 53 planning pregnancy) or without (107 pregnant and 57 planning pregnancy). We found a small difference in HbA1c in pregnant women using CGM (mean difference -0·19%; 95% CI -0·34 to -0·03; p=0·0207). Pregnant CGM users spent more time in target (68% vs 61%; p=0·0034) and less time hyperglycaemic (27% vs 32%; p=0·0279) than did pregnant control participants, with comparable severe hypoglycaemia episodes (18 CGM and 21 control) and time spent hypoglycaemic (3% vs 4%; p=0·10). Neonatal health outcomes were significantly improved, with lower incidence of large for gestational age (odds ratio 0·51, 95% CI 0·28 to 0·90; p=0·0210), fewer neonatal intensive care admissions lasting more than 24 h (0·48; 0·26 to 0·86; p=0·0157), fewer incidences of neonatal hypoglycaemia (0·45; 0·22 to 0·89; p=0·0250), and 1-day shorter length of hospital stay (p=0·0091). We found no apparent benefit of CGM in women planning pregnancy. Adverse events occurred in 51 (48%) of CGM participants and 43 (40%) of control participants in the pregnancy trial, and in 12 (27%) of CGM participants and 21 (37%) of control participants in the planning pregnancy trial. Serious adverse events occurred in 13 (6%) participants in the pregnancy trial (eight [7%] CGM, five [5%] control) and in three (3%) participants in the planning pregnancy trial (two [4%] CGM and one [2%] control). The most common adverse events were skin reactions occurring in 49 (48%) of 103 CGM participants and eight (8%) of 104 control participants during pregnancy and in 23 (44%) of 52 CGM participants and five (9%) of 57 control participants in the planning pregnancy trial. The most common serious adverse events were gastrointestinal (nausea and vomiting in four participants during pregnancy and three participants planning pregnancy). INTERPRETATION: Use of CGM during pregnancy in patients with type 1 diabetes is associated with improved neonatal outcomes, which are likely to be attributed to reduced exposure to maternal hyperglycaemia. CGM should be offered to all pregnant women with type 1 diabetes using intensive insulin therapy. This study is the first to indicate potential for improvements in non-glycaemic health outcomes from CGM use. FUNDING: Juvenile Diabetes Research Foundation, Canadian Clinical Trials Network, and National Institute for Health Research.


Subject(s)
Blood Glucose/analysis , Diabetes Mellitus, Type 1/diagnosis , Diabetes Mellitus, Type 1/drug therapy , Insulin/administration & dosage , Monitoring, Physiologic/methods , Pregnancy Outcome , Adolescent , Adult , Female , Humans , Internationality , Observer Variation , Odds Ratio , Pregnancy , Risk Assessment , Severity of Illness Index , Young Adult
17.
Blood ; 127(2): 260-7, 2016 Jan 14.
Article in English | MEDLINE | ID: mdl-26527675

ABSTRACT

There are >24 million registered adult donors, and the numbers of unrelated donor transplantations are increasing. The optimal strategy for prioritizing among comparably HLA-matched potential donors has not been established. Therefore, the objective of the current analyses was to study the association between donor characteristics (age, sex, parity, cytomegalovirus serostatus, HLA match, and blood group ABO match) and survival after transplantation for hematologic malignancy. The association of donor characteristics with transplantation outcomes was examined using either logistic or Cox regression models, adjusting for patient disease and transplantation characteristics associated with outcomes in 2 independent datasets: 1988 to 2006 (N = 6349; training cohort) and 2007 to 2011 (N = 4690; validation cohort). All donor-recipient pairs had allele-level HLA typing at HLA-A, -B, -C, and -DRB1, which is the current standard for selecting donors. Adjusting for patient disease and transplantation characteristics, survival was better after transplantation of grafts from young donors (aged 18-32 years) who were HLA matched to recipients (P < .001). These findings were validated for transplantations that occurred between 2007 and 2011. For every 10-year increment in donor age, there is a 5.5% increase in the hazard ratio for overall mortality. Increasing HLA disparity was also associated with worsening survival. Donor age and donor-recipient HLA match are important when selecting adult unrelated donors. Other donor characteristics such as sex, parity, and cytomegalovirus serostatus were not associated with survival. The effect of ABO matching on survival is modest and must be studied further before definitive recommendations can be offered.


Subject(s)
Hematologic Neoplasms/mortality , Hematologic Neoplasms/therapy , Hematopoietic Stem Cell Transplantation , Unrelated Donors/statistics & numerical data , Adolescent , Adult , Female , Graft vs Host Disease/immunology , Graft vs Host Disease/mortality , Hematologic Neoplasms/immunology , Hematopoietic Stem Cell Transplantation/adverse effects , Hematopoietic Stem Cell Transplantation/mortality , Histocompatibility/immunology , Histocompatibility Testing , Humans , Male , Middle Aged , Survival Analysis , Young Adult
18.
Pediatr Diabetes ; 19(7): 1156-1163, 2018 11.
Article in English | MEDLINE | ID: mdl-29923263

ABSTRACT

OBJECTIVE: To examine and compare the clinical characteristics and treatment of youth with type 2 diabetes (T2D) in two registries: one in Europe and one in the United States. METHODS: Youth with onset of T2D at 10 to 18 years of age with current age <20 years and an office visit after diabetes duration >1 year were identified in the European (Prospective Diabetes Follow-up, DPV) and the United States (Pediatric Diabetes Consortium, PDC) databases. Demographic, physical and clinical characteristics and treatment at diagnosis as well as physical characteristics, treatment, laboratory data, and diabetes adverse events at most recent visit were analyzed from both registries. RESULTS: At diagnosis, the majority were female and obese; 70% of DPV vs 34% of PDC youth were diagnosed by targeted diabetes testing. PDC youth were younger, 12 vs 13 years (P < 0.001), had a greater body mass index-SDS, 3.07 vs 2.74 (P < 0.001), a higher hemoglobin A1c (HbA1c), 9.9% vs 7.1% (P < 0.001), were more likely to present in DKA, 7.5% vs 1.3% (P < 0.001) and more likely to be treated with insulin, 62% vs 32% (P < 0.001); insulin treatment difference was not significant when adjusted for HbA1c. At follow-up, DPV youth had shorter diabetes duration, 2.1 vs 3.2 years (P < 0.001), lower HbA1c, 6.5% vs 7.8% (P < 0.001), were less likely to be treated with insulin, 36% vs 56%, (P < 0.001), and were more likely to have dyslipidemia and hypertension than PDC youth. PDC youth had a higher rate of microalbuminuria. CONCLUSIONS: Both DPV and PDC youth have multiple risks for diabetes complications. Understanding reasons for persistently higher HbA1c in PDC youth requires further study.


Subject(s)
Diabetes Mellitus, Type 2/epidemiology , Registries , Adolescent , Child , Europe/epidemiology , Female , Humans , Male , Pediatrics/statistics & numerical data , Prospective Studies , United States/epidemiology
19.
Pediatr Diabetes ; 19(8): 1379-1384, 2018 12.
Article in English | MEDLINE | ID: mdl-30175440

ABSTRACT

BACKGROUND/OBJECTIVE: Restrictive eligibility criteria have hampered enrollment into trials for new drugs for youth with type 2 diabetes (T2D). We utilized Pediatric Diabetes Consortium (PDC) T2D Registry enrollment data to estimate the percentage of patients who would be excluded from current T2D trials based on out-of-range HbA1c levels. We also examined whether well-controlled patients could be included because baseline HbA1c would rise during a 6 to 12-month study if assigned to control group. METHODS: Clinical characteristics and HbA1c levels were collected from 956 T2D patients aged 10 to <18 years upon Registry enrollment. HbA1c levels were also analyzed in 6-month intervals during the first 30 months of T2D duration. RESULTS: There was an approximately 2:1 ratio of females to males; the majority were obese and from economically disadvantaged minority families. On enrollment in the Registry, 53% of patients would be excluded from current trials because HbA1c levels were either <6.5% (<48 mmol/mol) (37%) or >10.5% (>91 mmol/mol) (16%). Furthermore, in patients with HbA1c levels <6.5% (<48 mmol/mol) and T2D duration between 6 and 30 months, mean HbA1c levels increased by 0.6% (6 mmol/mol) and 0.9% (10 mmol/mol) over the subsequent 6 and 12 months, respectively. CONCLUSIONS: Eligibility criteria for current clinical trials still exclude a large proportion of pediatric T2D patients because of HbA1c levels. Including patients with HbA1c <6.5% (<48 mmol/mol) would enhance recruitment and allow comparisons of the investigational treatment with placebo-assigned subjects in whom HbA1c levels would on average increase during the 6 to 12 months of the trial.


Subject(s)
Clinical Trials as Topic/statistics & numerical data , Diabetes Mellitus, Type 2/epidemiology , Diabetes Mellitus, Type 2/therapy , Patient Selection , Registries/statistics & numerical data , Adolescent , Age of Onset , Child , Female , Health Services Accessibility/organization & administration , Health Services Accessibility/statistics & numerical data , Humans , Male , Pediatrics/organization & administration , Research Design
20.
Pediatr Diabetes ; 19(3): 420-428, 2018 05.
Article in English | MEDLINE | ID: mdl-29159870

ABSTRACT

OBJECTIVE: The primary objective of this trial was to evaluate the feasibility, safety, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system vs predictive low glucose suspension (PLGS) alone in optimizing overnight glucose control in children 6 to 14 years old. RESEARCH DESIGN AND METHODS: Twenty-eight participants 6 to 14 years old with T1D duration ≥1 year with daily insulin therapy ≥12 months and on insulin pump therapy for ≥6 months were randomized per night into PHHM mode or PLGS-only mode for 42 nights. The primary outcome was percentage of time in sensor-measured range 70 to 180 mg/dL in the overnight period. RESULTS: The addition of automated insulin delivery with PHHM increased time in target range (70-180 mg/dL) from 66 ± 11% during PLGS nights to 76 ± 9% during PHHM nights (P<.001), without increasing hypoglycemia as measured by time below various thresholds. Average morning blood glucose improved from 176 ± 28 mg/dL following PLGS nights to 154 ± 19 mg/dL following PHHM nights (P<.001). CONCLUSIONS: The PHHM system was effective in optimizing overnight glycemic control, significantly increasing time in range, lowering mean glucose, and decreasing glycemic variability compared to PLGS alone in children 6 to 14 years old.


Subject(s)
Diabetes Mellitus, Type 1/blood , Hyperglycemia/prevention & control , Hypoglycemia/prevention & control , Insulin Infusion Systems , Monitoring, Ambulatory/instrumentation , Adolescent , Blood Glucose , Child , Clinical Alarms , Diabetes Mellitus, Type 1/drug therapy , Double-Blind Method , Feasibility Studies , Female , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL