Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Blood Purif ; 52(3): 275-284, 2023.
Article in English | MEDLINE | ID: mdl-37068476

ABSTRACT

INTRODUCTION: Low-flow veno-venous extracorporeal CO2 removal (ECCO2R) is an adjunctive therapy to support lung protective ventilation or maintain spontaneous breathing in hypercapnic respiratory failure. Low-flow ECCO2R is less invasive compared to higher flow systems, while potentially compromising efficiency and membrane lifetime. To counteract this shortcoming, a high-longevity system has recently been developed. Our hypotheses were that the novel membrane system provides runtimes up to 120 h, and CO2 removal remains constant throughout membrane system lifetime. METHODS: Seventy patients with pH ≤ 7.25 and/or PaCO2 ≥9 kPa exceeding lung protective ventilation limits, or experiencing respiratory exhaustion during spontaneous breathing, were treated with the high-longevity ProLUNG system or in a control group using the original gas exchanger. Treatment parameters, gas exchanger runtime, and sweep-gas VCO2 were recorded across 9,806 treatment-hours and retrospectively analyzed. RESULTS: 25/33 and 23/37 patients were mechanically ventilated as opposed to awake spontaneously breathing in both groups. The high-longevity system increased gas exchanger runtime from 29 ± 16 to 48 ± 36 h in ventilated and from 22 ± 14 to 31 ± 31 h in awake patients (p < 0.0001), with longer runtime in the former (p < 0.01). VCO2 remained constant at 86 ± 34 mL/min (p = 0.11). Overall, PaCO2 decreased from 9.1 ± 2.0 to 7.9 ± 1.9 kPa within 1 h (p < 0.001). Tidal volume could be maintained at 5.4 ± 1.8 versus 5.7 ± 2.2 mL/kg at 120 h (p = 0.60), and peak airway pressure could be reduced from 31.1 ± 5.1 to 27.5 ± 6.8 mbar (p < 0.01). CONCLUSION: Using a high-longevity gas exchanger system, membrane lifetime in low-flow ECCO2R could be extended in comparison to previous systems but remained below 120 h, especially in spontaneously breathing patients. Extracorporeal VCO2 remained constant throughout gas exchanger system runtime and was consistent with removal of approximately 50% of expected CO2 production, enabling lung protective ventilation despite hypercapnic respiratory failure.


Subject(s)
Respiratory Distress Syndrome , Respiratory Insufficiency , Humans , Carbon Dioxide , Retrospective Studies , Respiratory Distress Syndrome/therapy , Respiratory Insufficiency/therapy , Respiration, Artificial
SELECTION OF CITATIONS
SEARCH DETAIL