1.
ACS Appl Mater Interfaces ; 13(7): 7854-7864, 2021 Feb 24.
Article in English | MEDLINE | ID: mdl-33560115

ABSTRACT

Graphene field-effect transistors (GFETs) are suitable building blocks for high-performance electrical biosensors, because graphene inherently exhibits a strong response to charged biomolecules on its surface. However, achieving ultralow limit-of-detection (LoD) is limited by sensor response time and screening effect. Herein, we demonstrate that the detection limit of GFET biosensors can be improved significantly by decorating the uncovered graphene sensor area with carbon dots (CDs). The developed CDs-GFET biosensors used for exosome detection exhibited higher sensitivity, faster response, and three orders of magnitude improvements in the LoD compared with nondecorated GFET biosensors. A LoD down to 100 particles/µL was achieved with CDs-GFET sensor for exosome detection with the capability for further improvements. The results were further supported by atomic force microscopy (AFM) and fluorescent microscopy measurements. The high-performance CDs-GFET biosensors will aid the development of an ultrahigh sensitivity biosensing platform based on graphene for rapid and early diagnosis of diseases.


Subject(s)
Biosensing Techniques , Carbon/chemistry , Exosomes/chemistry , Quantum Dots/chemistry , Transistors, Electronic , Particle Size , Surface Properties
2.
Sci Rep ; 9(1): 13946, 2019 09 26.
Article in English | MEDLINE | ID: mdl-31558796

ABSTRACT

A graphene field-effect transistor (gFET) was non-covalently functionalised with 1-pyrenebutyric acid N-hydroxysuccinimide ester and conjugated with anti-CD63 antibodies for the label-free detection of exosomes. Using a microfluidic channel, part of a graphene film was exposed to solution. The change in electrical properties of the exposed graphene created an additional minimum alongside the original Dirac point in the drain-source current (Ids) - back-gate voltage (Vg) curve. When phosphate buffered saline (PBS) was present in the channel, the additional minimum was present at a Vg lower than the original Dirac point and shifted with time when exosomes were introduced into the channel. This shift of the minimum from the PBS reference point reached saturation after 30 minutes and was observed for multiple exosome concentrations. Upon conjugation with an isotype control, sensor response to the highest concentration of exosomes was negligible in comparison to that with anti-CD63 antibody, indicating that the functionalised gFET can specifically detect exosomes at least down to 0.1 µg/mL and is sensitive to concentration. Such a gFET biosensor has not been used before for exosome sensing and could be an effective tool for the liquid-biopsy detection of exosomes as biomarkers for early-stage identification of diseases such as cancer.

SELECTION OF CITATIONS
SEARCH DETAIL