Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Artif Organs ; 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39105561

ABSTRACT

BACKGROUND: Temporal trends of routinely obtained parameters may provide valuable information for predicting BSIs, but this association has not yet been established in LVAD patients. METHODS: This retrospective analysis included data from 347 consecutive recipients of three rotary LVAD types. Study endpoints included the incidence of BSI, the association of temporal trends of routinely obtained blood biomarkers with the development of BSIs, the incidence of BSIs, and survival on LVAD support. RESULTS: During follow-up, 47.8% (n = 166) of the patients developed BSI. In multivariate analyses, the development of BSI was a significant predictor of mortality (HR 5.78, 95% CI 4.08-8.19, p < 0.0001). In univariate analyses, after adjusting for potential confounders, albumin (SHR 0.94, 95% CI 0.91-0.97, p < 0.00010), creatinine (SHR 1.49, 95% CI 1.03-2.15, p = 0.033), and C-reactive protein (SHR 1.19, 95% CI 1.08-1.32, p = 0.0007) significantly predicted the development of BSIs during LVAD support. Notably, the strength of the association of parameter changes with the prediction of BSIs demonstrated a time-dependent correlation in the cases of albumin (p = 0.045) and creatinine (p = 0.003). CONCLUSION: Bloodstream infections are highly prevalent among LVAD recipients and are independent predictors of mortality. Temporal biomarker trends significantly predict the development of BSIs. These findings suggest opportunities for interventions aiming to reduce the incidence of BSIs.

2.
Article in English | MEDLINE | ID: mdl-39140312

ABSTRACT

Infective endocarditis, particularly after implanting valve prostheses, poses significant surgical challenges, often requiring complex interventions. We describe a case of a 37-year-old male with Staphylococcus aureus endocarditis, unsuccessfully treated with mechanical valve prostheses. Continued infection led to the destruction of the intervalvular fibrous body, necessitating a Commando procedure involving radical debridement and replacement of both aortic and mitral valves with complex patch reconstruction. Prosthesis selection remains contentious, considering recurrence risk and long-term prognosis. Our case underscores timely intervention and meticulous technique in managing such complex situations. It highlights successful strategies for treating infective endocarditis with destruction of aortomitral continuity, emphasizing the pivotal role of the Commando procedure.


Subject(s)
Aortic Valve , Endocarditis, Bacterial , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Prosthesis-Related Infections , Staphylococcal Infections , Humans , Male , Adult , Endocarditis, Bacterial/surgery , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/etiology , Heart Valve Prosthesis/adverse effects , Staphylococcal Infections/diagnosis , Staphylococcal Infections/surgery , Staphylococcal Infections/etiology , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/etiology , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/surgery , Staphylococcus aureus/isolation & purification , Reoperation , Debridement/methods
3.
IEEE Trans Biomed Eng ; 71(5): 1651-1662, 2024 May.
Article in English | MEDLINE | ID: mdl-38133971

ABSTRACT

OBJECTIVE: Conventional mock circulatory loops (MCLs) cannot replicate realistic hemodynamic conditions without inducing blood trauma. This constrains in-vitro hemocompatibility examinations of blood pumps to static test loops that do not mimic clinical scenarios. This study aimed at developing an atraumatic MCL based on a hardware-in-the-loop concept (H-MCL) for realistic hemocompatibility assessment. METHODS: The H-MCL was designed for 450 ± 50 ml of blood with the polycarbonate reservoirs, the silicone/polyvinyl-chloride tubing, and the blood pump under investigation as the sole blood-contacting components. To account for inherent coupling effects a decoupling pressure control was derived by feedback linearization, whereas the level control was addressed by an optimization task to overcome periodic loss of controllability. The HeartMate 3 was showcased to evaluate the H-MCL's accuracy at typical hemodynamic conditions. To verify the atraumatic properties of the H-MCL, hemolysis (bovine blood, n = 6) was evaluated using the H-MCL in both inactive (static) and active (minor pulsatility) mode, and compared to results achieved in conventional loops. RESULTS: Typical hemodynamic scenarios were replicated with marginal coupling effects and root mean square error (RMSE) below 1.74 ± 1.37 mmHg while the fluid level remained within ±4% of its target value. The normalized indices of hemolysis (NIH) for the inactive H-MCL showed no significant differences to conventional loops ( ∆NIH = -1.6 mg/100 L). Further, no significant difference was evident between the active and inactive mode in the H-MCL ( ∆NIH = +0.3 mg/100 L). CONCLUSION AND SIGNIFICANCE: Collectively, these findings indicated the H-MCL's potential for in-vitro hemocompatibility assessment of blood pumps within realistic hemodynamic conditions, eliminating inherent setup-related risks for blood trauma.


Subject(s)
Heart-Assist Devices , Hemolysis , Animals , Hemolysis/physiology , Cattle , Equipment Design , Hemodynamics/physiology , Materials Testing/methods , Models, Cardiovascular , Humans
4.
Front Cardiovasc Med ; 11: 1363336, 2024.
Article in English | MEDLINE | ID: mdl-38322769

ABSTRACT

Objectives: To date, there is no evidence regarding the safety of automated titanium fastener compared with hand-tied knots for prosthesis fixation in infective endocarditis. Methods: Between January 2016 and December 2022, a total of 220 patients requiring surgery for infective endocarditis were included in this retrospective analysis. The primary study endpoint was re-endocarditis during follow-up. The secondary study endpoints included stroke onset, all-cause mortality, and a composite outcome of either re-endocarditis, stroke, or all-cause mortality during follow-up. Results: Suture-securing with an automated titanium fastener was performed in 114 (51.8%) patients, whereas the conventional technique of hand knot-tying was used in 106 (48.2%) patients. The risk of re-endocarditis was significantly lower in the automated titanium fastener group, as shown in a multivariable proportional competing risk regression model (adjusted sub-hazard ratio 0.33, 95% confidence interval 0.11-0.99, p = 0.048). The multivariable Cox proportional hazards regression analysis showed that the automated titanium fastener group was not associated with an increased risk of stroke-onset or attaining the composite outcome, respectively, (adjusted hazard ratio 0.54, 95% confidence interval 0.27-1.08, p = 0.082), (adjusted hazard ratio 0.65, 95% confidence interval 0.42-1.02, p = 0.061). Also, this group was not associated with an increased risk of all-cause mortality, as demonstrated in the multivariable Poisson regression analysis (adjusted incidence-rate ratio 1.42, 95% confidence interval 0.83-2.42, p = 0.202). Conclusions: The use of automated titanium fastener device seems to be safe for infective endocarditis. Analyses of larger cohorts are required.

5.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38532304

ABSTRACT

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients. METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9-55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6 mm (standard deviation 2.4). The median operation duration was 312 min (IQR 234-417), the median cardiopulmonary bypass time was 154 min (IQR 118-212) and the median cross-clamp time 121 min (IQR 93-150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5 h postoperation. There were 3 late deaths, 1 death due to endocarditis 4 months postoperatively and 2 unrelated deaths after 5 and 7 years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9 years [IQR 5.1-6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0 mmHg (IQR 7.8-17.6) and regurgitation of median 0.5 (IQR 0-0.5) of grade 0-3 were excellent. At 5 years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively. CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adult , Humans , Male , Allografts/surgery , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Endocarditis/surgery , Follow-Up Studies , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Reoperation , Routinely Collected Health Data , Female , Adolescent , Young Adult , Middle Aged
6.
Article in English | MEDLINE | ID: mdl-39128016

ABSTRACT

OBJECTIVES: We investigated the sex-related difference in characteristics and 2-year outcomes after surgical aortic valve replacement (SAVR) by propensity-score matching (PSM). METHODS: Data from 2 prospective registries, the INSPIRIS RESILIA Durability Registry (INDURE) and IMPACT, were merged, resulting in a total of 933 patients: 735 males and 253 females undergoing first-time SAVR. The PSM was performed to assess the impact of sex on the SAVR outcomes, yielding 433 males and 243 females with comparable baseline characteristics. RESULTS: Females had a lower body mass index (median 27.1 vs 28.0 kg/m2; P = 0.008), fewer bicuspid valves (52% vs 59%; P = 0.036), higher EuroSCORE II (mean 2.3 vs 1.8%; P < 0.001) and Society of Thoracic Surgeons score (mean 1.6 vs 0.9%; P < 0.001), were more often in New York Heart Association functional class III/IV (47% vs 30%; P < 0.001) and angina Canadian Cardiovascular Society III/IV (8.2% vs 4.4%; P < 0.001), but had a lower rate of myocardial infarction (1.9% vs 5.2%; P = 0.028) compared to males. These differences vanished after PSM, except for the EuroSCORE II and Society of Thoracic Surgeons scores, which were still significantly higher in females. Furthermore, females required smaller valves (median diameter 23.0 vs 25.0 mm, P < 0.001). There were no differences in the length of hospital stay (median 8 days) or intensive care unit stay (median 24 vs 25 hours) between the 2 sexes. At 2 years, post-SAVR outcomes were comparable between males and females, even after PSM. CONCLUSIONS: Despite females presenting with a significantly higher surgical risk profile, 2-year outcomes following SAVR were comparable between males and females.

SELECTION OF CITATIONS
SEARCH DETAIL