Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 377
Filter
Add more filters

Publication year range
1.
Circulation ; 147(25): 1933-1944, 2023 06 20.
Article in English | MEDLINE | ID: mdl-37335828

ABSTRACT

Antiplatelet therapy is the mainstay of pharmacologic treatment to prevent thrombotic or ischemic events in patients with coronary artery disease treated with percutaneous coronary intervention and those treated medically for an acute coronary syndrome. The use of antiplatelet therapy comes at the expense of an increased risk of bleeding complications. Defining the optimal intensity of platelet inhibition according to the clinical presentation of atherosclerotic cardiovascular disease and individual patient factors is a clinical challenge. Modulation of antiplatelet therapy is a medical action that is frequently performed to balance the risk of thrombotic or ischemic events and the risk of bleeding. This aim may be achieved by reducing (ie, de-escalation) or increasing (ie, escalation) the intensity of platelet inhibition by changing the type, dose, or number of antiplatelet drugs. Because de-escalation or escalation can be achieved in different ways, with a number of emerging approaches, confusion arises with terminologies that are often used interchangeably. To address this issue, this Academic Research Consortium collaboration provides an overview and definitions of different strategies of antiplatelet therapy modulation for patients with coronary artery disease, including but not limited to those undergoing percutaneous coronary intervention, and consensus statements on standardized definitions.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Percutaneous Coronary Intervention , Thrombosis , Humans , Platelet Aggregation Inhibitors/adverse effects , Coronary Artery Disease/complications , Hemorrhage/etiology , Blood Platelets , Dual Anti-Platelet Therapy/adverse effects , Acute Coronary Syndrome/therapy , Thrombosis/etiology , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome
2.
Catheter Cardiovasc Interv ; 101(6): 1036-1044, 2023 05.
Article in English | MEDLINE | ID: mdl-37017418

ABSTRACT

BACKGROUND: Isolate features of the coronary anatomy have been associated with the pathophysiology of atherosclerotic disease. Computational methods have been described to allow precise quantification of the complex three-dimensional (3D) coronary geometry. The present study tested whether quantitative parameters that describe the spatial 3D coronary geometry is associated with the extension and composition of the underlying coronary artery disease (CAD). METHODS: Patients with CAD scheduled for percutaneous intervention were investigated with coronary computed tomography angiography (CCTA), and invasive coronary angiography, and virtual histology intravascular ultrasound (IVUS-VH). For all target vessels, 3D centerlines were extracted from CCTA images and processed to quantify 23 geometric indexes, grouped into 3 main categories as follows: (i) length-based; (ii) curvature-based, torsion-based, and curvature/torsion-combined; (iii) vessel path-based. The geometric variables were compared with IVUS-VH parameters assessing the extent and composition of coronary atherosclerosis. RESULTS: A total of 36 coronary patients (99 vessels) comprised the study population. From the 23 geometric indexes, 18 parameters were significantly (p < 0.05) associated with at least 1 IVUS-VH parameter at a univariate analysis. All three main geometric categories provided parameters significantly related with atherosclerosis variables. The 3D geometric indexes were associated with the degree of atherosclerotic extension, as well as with plaque composition. Geometric features remained significantly associated with all IVUS-VH parameters even after multivariate adjustment for clinical characteristics. CONCLUSIONS: Quantitative 3D vessel morphology emerges as a relevant factor associated with atherosclerosis in patients with established CAD.


Subject(s)
Atherosclerosis , Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Ultrasonography, Interventional/methods , Treatment Outcome , Coronary Artery Disease/pathology , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Predictive Value of Tests
3.
Eur Heart J ; 43(41): 4378-4388, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36030400

ABSTRACT

AIMS: To evaluate whether a strategy of double-dose influenza vaccination during hospitalization for an acute coronary syndrome (ACS) compared with standard-dose outpatient vaccination (as recommended by current guidelines) would further reduce the risk of major cardiopulmonary events. METHODS AND RESULTS: Vaccination against Influenza to Prevent cardiovascular events after Acute Coronary Syndromes (VIP-ACS) was a pragmatic, randomized, multicentre, active-comparator, open-label trial with blinded outcome adjudication comparing two strategies of influenza vaccination following an ACS: double-dose quadrivalent inactivated vaccine before hospital discharge vs. standard-dose quadrivalent inactivated vaccine administered in the outpatient setting 30 days after randomization. The primary outcome was a hierarchical composite of all-cause death, myocardial infarction, stroke, unstable angina, hospitalization for heart failure, urgent coronary revascularization, and hospitalization for respiratory causes, analysed by the win ratio method. Patients were followed for 12 months. During two influenza seasons, 1801 participants were included at 25 centres in Brazil. The primary outcome was not different between groups, with 12.7% wins in-hospital double-dose vaccine group and 12.3% wins in the standard-dose vaccine group {win ratio: 1.02 [95% confidence interval (CI): 0.79-1.32], P = 0.84}. Results were consistent for the key secondary outcome, a hierarchical composite of cardiovascular death, myocardial infarction and stroke [win ratio: 0.94 (95% CI: 0.66-1.33), P = 0.72]. Time-to-first event analysis for the primary outcome showed results similar to those of the main analysis [hazard ratio 0.97 (95% CI: 0.75-1.24), P = 0.79]. Adverse events were infrequent and did not differ between groups. CONCLUSION: Among patients hospitalized with an ACS, double-dose influenza vaccination before discharge did not reduce cardiopulmonary outcomes compared with standard-dose vaccination in the outpatient setting. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number: NCT04001504.


Subject(s)
Acute Coronary Syndrome , Influenza, Human , Myocardial Infarction , Stroke , Humans , Acute Coronary Syndrome/therapy , Influenza, Human/prevention & control , Myocardial Infarction/prevention & control , Vaccination , Stroke/prevention & control , Vaccines, Inactivated , Treatment Outcome
4.
Ren Fail ; 45(1): 2224888, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37350345

ABSTRACT

BACKGROUND: Candidates for transcatheter aortic valve implantation (TAVI) are currently evaluated using computed tomography angiography and invasive cardiac catheterization as an essential part of case selection and pre-procedure interventional planning. However, both imaging methods utilize iodinated agents, which may cause contrast-induced nephropathy, particularly in patients with baseline renal dysfunction. This study aimed to describe a zero-contrast imaging protocol for pre-TAVI evaluation in patients with advanced renal impairment. METHODS: The pre-TAVI zero-contrast scheme consisted of the following multi-modality combinations: (1) gadolinium-free magnetic resonance imaging (three-dimensional navigator-echo with electrocardiogram-gated steady-state free-precession series); (2) iodinated-free multislice computed tomography electrocardiogram-gated; (3) lower limb arterial duplex scan ultrasound; and (4) transesophageal echocardiography. Ultimately, TAVI was performed for those deemed good candidates, and contrast was allowed during the intervention; however, operators were strongly advised to utilize the least volume possible of iodinated agents. This pilot survey included ten patients with symptomatic aortic stenosis and renal dysfunction who underwent zero-contrast multi-modality imaging. RESULTS: All the patients ultimately underwent TAVI. The intervention was successful in all cases, without ≥ moderate residual aortic regurgitation, prosthesis embolization, annulus rupture, major vascular complications, stroke, or death during index hospitalization. The creatinine clearance remained stable throughout the observation period (baseline: 26.85 ± 12.55 mL/min; after multi-modality imaging: 26.76 ± 11.51 mL/min; post-TAVI at discharge: 29.84 ± 13.98 mL/min; p = 0.3 all). CONCLUSION: The proposed contrast-free imaging protocol appears to be a promising clinical tool for pre-TAVI evaluation in patients with severe renal dysfunction.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Multidetector Computed Tomography , Cardiac Catheterization/methods
5.
Int Braz J Urol ; 49(3): 334-340, 2023.
Article in English | MEDLINE | ID: mdl-37115178

ABSTRACT

PURPOSE: To analyze the learning curve regarding complication rates of transrectal prostate biopsy (TRPB) versus transperineal prostate biopsy (TPPB), using real time software-based magnetic resonance imaging ultrasound (MRI-US) fusion techniques, along with first year experience of transperineal approach. MATERIALS AND METHODS: retrospective unicentric cohort study at a quaternary care hospital. Medical records of all consecutive patients that underwent TPPB between March 2021 and February 2022, after the introduction of MRI-US fusion device, and those who underwent TRPB throughout the entire years of 2019 and 2020 were analyzed. All complications that occurred as consequences of the procedure were considered. Descriptive statistics, Chi-squared and Fisher tests were used to describe complications and compare the two groups. RESULTS: A total of 283 patients were included in the transperineal group and 513 in the transrectal group. The analysis of a learning curve for the transperineal method showed lower complications rates comparing the first six months of TPPB procedures (group 1); The complication rate for TPPB was lower than that of TRPB (55.1% versus 81.9%, respectively; p<0.01). TPPB showed specifically lower rates of hematuria (48.8% versus 66.3%;p<0.001) and rectal bleeding(3.5% versus 18.1%; p<0.001). There were no cases of prostatitis after transperineal biopsies and three cases (0.6%) after transrectal procedures. CONCLUSIONS: We evidenced the learning curve for performing the transperineal biopsy, with a lower rate of complications for the experienced team, after 142 cases after 6 months of practice. The lower complication rate of TPPB and the absence of infectious prostatitis imply a safer procedure when compared to TRPB.


Subject(s)
Prostatic Neoplasms , Prostatitis , Male , Humans , Prostate/pathology , Prostatic Neoplasms/pathology , Prostatitis/pathology , Learning Curve , Retrospective Studies , Cohort Studies , Biopsy/methods , Image-Guided Biopsy/methods , Ultrasonography, Interventional/adverse effects , Ultrasonography, Interventional/methods
6.
J Infect Dis ; 224(6): 1005-1014, 2021 09 17.
Article in English | MEDLINE | ID: mdl-33507265

ABSTRACT

BACKGROUND: There is a steady rise in the global incidence of Aedes-borne arbovirus disease. It has become urgent to develop alternative solutions for mosquito vector control. We developed a new method of sterilization of male mosquitoes with the goal to suppress a local Aedes aegypti population and to prevent the spread of dengue. METHODS: Sterile male mosquitoes were produced from a locally acquired Ae. aegypti colony by using a treatment that includes double-stranded RNA and thiotepa. A field study was conducted with sterile mosquito releases being performed on a weekly basis in predefined areas. There were 2 intervention periods (INT1 and INT2), with treatment and control areas reversed between INT1 and INT2. RESULTS: During INT1, releases in the treated area resulted in up to 91.4% reduction of live progeny of field Ae. aegypti mosquitoes recorded over time, while the control neighborhoods (no releases of sterile male mosquitoes) remained highly infested. The successful implementations of the program during INT1 and INT2 were associated with 15.9-fold and 13.7-fold lower incidences of dengue in the treated area compared to the control areas, respectively. CONCLUSIONS: Our data show the success of this new sterile insect technology-based program in preventing the spread of dengue.


Subject(s)
Aedes , Dengue/epidemiology , Mosquito Control/methods , Mosquito Vectors/physiology , Animals , Brazil , Dengue/prevention & control , Dengue/transmission , Incidence , Insecta , Male , Mosquito Vectors/microbiology , Polypyrimidine Tract-Binding Protein , Technology
7.
Catheter Cardiovasc Interv ; 98(3): E370-E378, 2021 09.
Article in English | MEDLINE | ID: mdl-33904638

ABSTRACT

OBJECTIVES: We aimed to explore angiographic patterns and in-hospital outcomes of patients with concomitant coronavirus disease-19 (COVID-19) and myocardial infarction (MI). BACKGROUND: Patients with COVID-19 may experience MI during the course of the viral infection. However, this association is currently poorly understood. METHODS: This is a multicenter prospective study of consecutive patients with concomitant COVID-19 and MI who underwent coronary angiography. Quantitative and qualitative coronary angiography were analyzed by two observers in an independent core lab. RESULTS: A total of 152 patients were included, of whom 142 (93.4%) had COVID-19 diagnosis confirmation. The median time between symptom onset and hospital admission was 5 (1-10) days. A total of 83 (54.6%) patients presented with ST-elevation MI. The median angiographic Syntax score was 16 (9.0-25.3) and 69.0% had multi-vessel disease. At least one complex lesion was found in 73.0% of patients, 51.3% had a thrombus containing lesion, and 57.9% had myocardial blush grades 0/1. The overall in-hospital mortality was 23.7%. ST-segment elevation MI presentation and baseline myocardial blush grades 0 or 1 were independently associated with a higher risk of death (HR 2.75, 95%CI 1.30-5.80 and HR 3.73, 95%CI 1.61-8.61, respectively). CONCLUSIONS: Patients who have a MI in the context of ongoing COVID-19 mostly present complex coronary morphologies, implying a background of prior atherosclerotic disease superimposed on a thrombotic milieu. The in-hospital prognosis is poor with a markedly high mortality, prompting further investigation to better clarify this newly described condition.


Subject(s)
COVID-19 , Myocardial Infarction , Percutaneous Coronary Intervention , COVID-19 Testing , Coronary Angiography , Hospital Mortality , Humans , Myocardial Infarction/diagnostic imaging , Prospective Studies , SARS-CoV-2 , Treatment Outcome
8.
Lancet ; 393(10190): 2503-2510, 2019 06 22.
Article in English | MEDLINE | ID: mdl-31056295

ABSTRACT

BACKGROUND: New-generation drug-eluting stents (DES) have mostly been investigated in head-to-head non-inferiority trials against early-generation DES and have typically shown similar efficacy and superior safety. How the safety profile of new-generation DES compares with that of bare-metal stents (BMS) is less clear. METHODS: We did an individual patient data meta-analysis of randomised clinical trials to compare outcomes after implantation of new-generation DES or BMS among patients undergoing percutaneous coronary intervention. The primary outcome was the composite of cardiac death or myocardial infarction. Data were pooled in a one-stage random-effects meta-analysis and examined at maximum follow-up and a 1-year landmark. Risk estimates are reported as hazard ratios (HRs) with 95% CIs. This study is registered in PROSPERO, number CRD42017060520. FINDINGS: We obtained individual data for 26 616 patients in 20 randomised trials. Mean follow-up was 3·2 (SD 1·8) years. The risk of the primary outcome was reduced in DES recipients compared with BMS recipients (HR 0·84, 95% CI 0·78-0·90, p<0·001) owing to a reduced risk of myocardial infarction (0·79, 0·71-0·88, p<0·001) and a possible slight but non-significant cardiac mortality benefit (0·89, 0·78-1·01, p=0·075). All-cause death was unaffected (HR with DES 0·96, 95% CI 0·88-1·05, p=0·358), but risk was lowered for definite stent thrombosis (0·63, 0·50-0·80, p<0·001) and target-vessel revascularisation (0·55, 0·50-0·60, p<0·001). We saw a time-dependent treatment effect, with DES being associated with lower risk of the primary outcome than BMS up to 1 year after placement. While the effect was maintained in the longer term, there was no further divergence from BMS after 1 year. INTERPRETATION: The performance of new-generation DES in the first year after implantation means that BMS should no longer be considered the gold standard for safety. Further development of DES technology should target improvements in clinical outcomes beyond 1 year. FUNDING: Bern University Hospital.


Subject(s)
Myocardial Infarction/surgery , Percutaneous Coronary Intervention/instrumentation , Stents/adverse effects , Aged , Aged, 80 and over , Drug-Eluting Stents/adverse effects , Equivalence Trials as Topic , Female , Humans , Male , Middle Aged , Myocardial Infarction/mortality , Odds Ratio , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 96(2): 422-423, 2020 08.
Article in English | MEDLINE | ID: mdl-32797747

ABSTRACT

Chronic thrombocytopenia is frequent in patients undergoing TAVR in the real world. Chronic thrombocytopenia is associated with worse in-hospital outcomes after TAVR. Future research is necessary to establish a better way of conducting and monitoring these patients.


Subject(s)
Aortic Valve Stenosis , Thrombocytopenia , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Blood Platelets , Delivery of Health Care , Hospitals , Humans , Platelet Count , Retrospective Studies , Risk Factors , Thrombocytopenia/diagnosis , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 96(4): E484-E492, 2020 10 01.
Article in English | MEDLINE | ID: mdl-32558228

ABSTRACT

OBJECTIVE: The present study evaluated the effect of endovascular administration of calcium chloride to the carotid artery of swines, to create a model of arterial calcification. METHODS: Fifteen Large White pigs were used for the study. Via endovascular treatment, carotid arteries were exposed during 9 min to either calcium chloride (experimental artery) or saline (control artery) with the use of the TAPAS catheter. Intravascular ultrasound (IVUS) imaging was obtained at baseline, postprocedure and at 30 days. Optical coherence tomography (OCT) imaging was obtained in vitro after carotids were harvested. Longitudinally cut parallel arterial segments were placed in a system of delicate clamps and underwent uniaxial strain test. All arteries underwent histopathological examination. RESULTS: Calcium chloride treated segments showed extensive circumferential parietal calcification evident on both IVUS and OCT. Reduction in minimal lumen area on IVUS was evident in experimental arteries both at 24 hr and 30 days postprocedure. Histopathologic assessment (Von Kossa stain) confirmed medial calcification with mild intimal thickening. Biomechanical testing showed treated segments to have smaller breaking strength and less elastic deformation than controls. CONCLUSION: We developed a nonexpensive, reproducible model of early carotid medial calcification in pigs. Our model has the potential to help the development of research to unravel mechanisms underlying arterial calcification, the use of current or new devices to treat calcified lesions as well as to serve as an option for training interventionalists on the use of such devices.


Subject(s)
Calcium Chloride , Carotid Artery Diseases/chemically induced , Carotid Artery, Common/pathology , Vascular Calcification/chemically induced , Animals , Biomechanical Phenomena , Carotid Artery Diseases/diagnostic imaging , Carotid Artery Diseases/pathology , Carotid Artery, Common/diagnostic imaging , Disease Models, Animal , Elasticity , Male , Neointima , Sus scrofa , Time Factors , Tomography, Optical Coherence , Ultrasonography, Interventional , Vascular Calcification/diagnostic imaging , Vascular Calcification/pathology
11.
Int J Qual Health Care ; 32(1): A1-A8, 2020 Apr 21.
Article in English | MEDLINE | ID: mdl-31832665

ABSTRACT

OBJECTIVE: We aim to examine the effect of benchmarking on quality-of-care metrics in patients presenting with ST-elevation myocardial infarction (STEMI) through the implementation of the American College of Cardiology (ACC) National Cardiovascular Data Registry (NCDR) ACTION Registry. DESIGN: From January 2005 to December 2017, 712 patients underwent primary percutaneous coronary intervention PCI-499 before NCDR ACTION Registry implementation (prior to 2013) and 213 after implementation. SETTING: STEMI. PARTICIPANTS: 712 patients. INTERVENTION(S): Primary PCI. MAIN OUTCOME MEASURE(S): We examined hospital performance for the quality indicators in processes and outcomes of the management of patients presenting with STEMI. Outcome measures include door-to-balloon time (DBT), antiplatelet therapy and anti-ischemic drugs prescribed at discharge from pre-NCDR ACTION Registry to post-implementation. RESULTS: There was improvement in DBT, decreasing from 94 min in 2012 (before NCDR adoption) to reach a median of 47 min in 2017 (Ptrend < 0.001). The percentage of cases with the optimal DBT of < 90 min increased from 55.8% before to 90.1% after the implementation of the NCDR ACTION Registry (Ptrend < 0.001). The rate of aspirin (90.3-100%, P < 0.001), P2Y12 inhibitor (70.1-78.4%, P = 0.02), beta-blocker (76.8-100%, P < 0.001) and angiotensin-converting enzyme inhibitors or angiotensin receptor blockers (60.1-99.5%, P < 0.001) prescribed at discharge increased from pre-NCDR ACTION Registry to post-implementation. Adjusted mortality before and after NCDR ACTION Registry implementation showed significant change (from 9.04 to 5.92%; P = 0.027). CONCLUSIONS: The introduction of the ACC NCDR ACTION Registry led to incremental gains in the quality in STEMI management through the benchmarking of process of care and clinical outcomes, achieving reduced DBT, improving guideline-directed medication adherence and increasing patient safety, treatment efficacy and survival.


Subject(s)
Benchmarking/methods , Quality Improvement/organization & administration , ST Elevation Myocardial Infarction/drug therapy , ST Elevation Myocardial Infarction/surgery , Adrenergic beta-Antagonists/therapeutic use , Aged , Angiotensin-Converting Enzyme Inhibitors , Brazil , Female , Humans , Male , Middle Aged , Outcome and Process Assessment, Health Care , Percutaneous Coronary Intervention/statistics & numerical data , Platelet Aggregation Inhibitors/therapeutic use , Registries , ST Elevation Myocardial Infarction/mortality , Time Factors
12.
Catheter Cardiovasc Interv ; 94(4): 644-650, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31334914

ABSTRACT

INTRODUCTION: Chagas disease is one of the most relevant endemic parasitic diseases in Latin America, affecting approximately 6 million people. Overt Chagas heart disease is an ominous condition, occurring in 20-30% of infected individuals, which has besides the persistent myocarditis a peculiar intracardiac ganglionic neuronal depletion and dysautonomy. This study aims to evaluate the safety and feasibility of renal denervation for patients with advanced symptomatic Chagas cardiomyopathy. METHODS: Open-label prospective pilot study that randomized patients with Chagas heart disease to either renal denervation or conservative treatment (2:1 ratio). The primary endpoint was the incidence of major adverse events at 9 months, defined as a composite of all-cause death, myocardial infarction, stroke, need for renal artery invasive treatment, or worsening renal function. RESULTS: A total of 17 patients were allocated for renal denervation (n = 11) or conservative treatment (n = 6). Included patients had severe symptomatic heart disease, with markedly depressed left ventricular function (average ejection fraction 26.7 ± 4.9%). For patients randomized to renal denervation, the procedure was performed successfully and uneventfully. After 9 months, the primary endpoint occurred in 36.4% of patients in the renal denervation group and 50.0% in the control arm (p = .6). After 9 months, clinical, laboratory, functional, echocardiographic, and quality of life parameters were similar between groups. CONCLUSIONS: This pilot study suggests that renal denervation is safe and feasible in patients with Chagas cardiomyopathy, warranting future studies to better evaluate the clinical efficacy of the interventional strategy in improving the prognosis of this high-risk population.


Subject(s)
Autonomic Denervation , Catheter Ablation , Chagas Cardiomyopathy/surgery , Heart Failure/surgery , Kidney/innervation , Aged , Autonomic Denervation/adverse effects , Autonomic Denervation/mortality , Brazil , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Chagas Cardiomyopathy/mortality , Chagas Cardiomyopathy/parasitology , Chagas Cardiomyopathy/physiopathology , Feasibility Studies , Female , Heart Failure/mortality , Heart Failure/parasitology , Heart Failure/physiopathology , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Recovery of Function , Time Factors , Treatment Outcome
13.
Catheter Cardiovasc Interv ; 93(2): 266-274, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30277641

ABSTRACT

OBJECTIVES: To evaluate the diagnostic performance of a novel computational algorithm based on three-dimensional intravascular ultrasound (IVUS) imaging in estimating fractional flow reserve (IVUSFR ), compared to gold-standard invasive measurements (FFRINVAS ). BACKGROUND: IVUS provides accurate anatomical evaluation of the lumen and vessel wall and has been validated as a useful tool to guide percutaneous coronary intervention. However, IVUS poorly represents the functional status (i.e., flow-related information) of the imaged vessel. METHODS: Patients with known or suspected stable coronary disease scheduled for elective cardiac catheterization underwent FFRINVAS measurement and IVUS imaging in the same procedure to evaluate intermediate lesions. A processing methodology was applied on IVUS to generate a computational mesh condensing the geometric characteristics of the vessel. Computation of IVUSFR was obtained from patient-level morphological definition of arterial districts and from territory-specific boundary conditions. FFRINVAS measurements were dichotomized at the 0.80 threshold to define hemodynamically significant lesions. RESULTS: A total of 24 patients with 34 vessels were analyzed. IVUSFR significantly correlated (r = 0.79; P < 0.001) and showed good agreement with FFRINVAS , with a mean difference of -0.008 ± 0.067 (P = 0.47). IVUSFR presented an overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 91%, 89%, 92%, 80%, and 96%, respectively, to detect significant stenosis. CONCLUSION: The computational processing of IVUSFR is a new method that allows the evaluation of the functional significance of coronary stenosis in an accurate way, enriching the anatomical information of grayscale IVUS.


Subject(s)
Algorithms , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Fractional Flow Reserve, Myocardial , Imaging, Three-Dimensional , Ultrasonography, Interventional/methods , Aged , Cardiac Catheterization , Coronary Angiography , Coronary Artery Disease/physiopathology , Coronary Vessels/physiopathology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results
14.
Eur Heart J ; 39(8): 687-695, 2018 02 21.
Article in English | MEDLINE | ID: mdl-29020413

ABSTRACT

Aims: There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. Methods and results: A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14-18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09-0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Conclusion: Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.


Subject(s)
Coronary Occlusion/epidemiology , Multidetector Computed Tomography/methods , Prosthesis Failure/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/etiology , Female , Heart Valve Prosthesis , Humans , Incidence , Male , Multivariate Analysis , Registries , Risk Factors
15.
Fungal Genet Biol ; 118: 10-20, 2018 09.
Article in English | MEDLINE | ID: mdl-29870836

ABSTRACT

Reversible protein phosphorylation is crucial for cell signal transduction in stress response. Fusarium oxysporum is a soil inhabiting fungus that can adapt to a wide range of ecological niches and environmental conditions. Three mitogen activated protein kinase (MAPK) cascades have been shown to orchestrate the response of the fungus to external insults such as high temperature, cell wall, oxidative or hyperosmotic stress in F. oxysporum. However, the protein phosphatases that fine-tune phosphorylation levels of different MAPKs in this fungus are unknown. In this study we show that the serine/threonine phosphatase Ptc1 regulates phosphorylation of the high osmolarity glycerol response (HOG) MAPK Hog1 and the cell wall integrity (CWI) MAPK Mpk1. A Δptc1 mutant showed decreased phosphorylation levels of the Mpk1 and was more sensitive to cell wall damaging agents in comparison to the wild type strain. In contrast, this mutant exhibited higher phosphorylation levels of the p38 MAPK Hog1, increased tolerance to osmotic stress compounds and higher expression of genes induced by osmotic stress. Moreover, Δptc1 contained fragmented vacuoles even in absence of the osmotic stressor, supporting the involvement of Ptc1 in the HOG pathway.


Subject(s)
Fusarium/genetics , Mitogen-Activated Protein Kinases/genetics , Osmotic Pressure , Fusarium/growth & development , Gene Expression Regulation, Fungal , Osmolar Concentration , Phosphorylation , Protein Phosphatase 2/genetics , Saccharomyces cerevisiae/genetics , Saccharomyces cerevisiae Proteins/genetics , Signal Transduction/genetics
16.
Catheter Cardiovasc Interv ; 92(6): 1049, 2018 11 15.
Article in English | MEDLINE | ID: mdl-30478882

ABSTRACT

The most important risk factors and preventive strategies for coronary atherosclerosis are systemic. However, the clinical manifestations of atherosclerotic disease frequently resemble a localized process, instead of a systemic one. In this issue of CCI, Zhang and co-workers described the association between the occurrence of stent failure and the changes in the 3D geometry of coronary segments induced by stent implantation. The investigation of local modulators of coronary disease appears as a large and fertile field of future cardiovascular research.


Subject(s)
Atherosclerosis , Coronary Artery Disease , Coronary Angiography , Humans , Male , Stents , Stress, Mechanical
17.
Catheter Cardiovasc Interv ; 91(6): 1043-1044, 2018 05 01.
Article in English | MEDLINE | ID: mdl-29737029

ABSTRACT

Failed CTO angioplasty was divided in two groups: with and without "subintimal plaque modification." At 1-month, patients treated with "subintimal plaque modification" had larger increases in health status as assessed by the Seattle Angina Questionnaire. The relatively small sample size and the lack of a longer follow-up period does not allow definite conclusion in terms of safety or clinical events.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Occlusion , Chronic Disease , Health Status , Humans , Treatment Outcome
18.
Catheter Cardiovasc Interv ; 92(7): E502-E511, 2018 12 01.
Article in English | MEDLINE | ID: mdl-30079472

ABSTRACT

OBJECTIVES: Based on outcomes of the BIOSOLVE-II study, a novel second generation drug-eluting absorbable metal scaffold gained CE-mark in 2016. The BIOSOLVE-III study aimed to confirm these outcomes and to obtain additional 12-month angiographic data. BACKGROUND: Bioresorbable scaffolds are intended to overcome possible long-term effects of permanent stents such as chronic vessel wall inflammation, stent crushing, and fractures. METHODS: The prospective, multicenter BIOSOLVE-II and BIOSOLVE-III studies enrolled 184 patients with 189 lesions (123 patients in BIOSOLVE-II and 61 patients in BIOSOLVE-III). Primary endpoints were in-segment late lumen loss at 6 months (BIOSOLVE-II) and procedural success (BIOSOLVE-III). RESULTS: Mean patient age was 65.5 ± 10.8 years and mean lesion reference diameter was 2.70 ± 0.43 mm. In BIOSOLVE-III, there were significantly more type B2/C lesions than in BIOSOLVE-II (80.3% versus 43.4%, P < 0.0001) and significantly more moderate-to-severe calcifications (24.2% versus 10.7%, P = 0.014). At 12 months, there was no difference in late lumen loss between the two studies; in the overall population, it was 0.25 ± 0.31 mm in-segment and 0.39 ± 0.34 mm in-scaffold. Target lesion failure occurred in six patients (3.3%) and included two cardiac deaths, one target-vessel myocardial infarction, and three clinically driven target lesion revascularizations. No definite or probable scaffold thrombosis was observed. CONCLUSION: The pooled outcomes of BIOSOLVE-II and BIOSOLVE-III provide further evidence on the safety and performance of a novel drug-eluting absorbable metal scaffold with constant clinical and angiographic performance parameters at 12 months and no definite or probable scaffold thrombosis.


Subject(s)
Absorbable Implants , Coronary Artery Disease/therapy , Coronary Vessels , Drug-Eluting Stents , Metals , Percutaneous Coronary Intervention/instrumentation , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/etiology , Coronary Vessels/diagnostic imaging , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 92(5): 945-953, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29520970

ABSTRACT

OBJECTIVES: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) BACKGROUND: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. METHODS: Patients (n = 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD (≤mild PVL + BPD) and Failed BPD (moderate-severe PVL + BPD). RESULTS: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter ≤0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P = .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P = .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). CONCLUSION: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.


Subject(s)
Aortic Valve Insufficiency/prevention & control , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Balloon Valvuloplasty , Heart Valve Prosthesis , Hemodynamics , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Brazil , Female , Humans , Male , Prosthesis Design , Recovery of Function , Registries , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
20.
Eur Heart J ; 38(25): 1969-1977, 2017 Jul 01.
Article in English | MEDLINE | ID: mdl-28431047

ABSTRACT

AIMS: To assess the impact of the SYNTAX scores I and II in outcomes after percutaneous coronary intervention (PCI) and coronary artery bypass graft (CABG) for patients with diabetes and multivessel disease (MVD). METHODS AND RESULTS: We performed a patient-level pooled analysis of three large randomized trials of patients with MVD. The impact of coronary anatomic complexity as measured by the SYNTAX score in the differences in outcomes following PCI and CABG was assessed at a median follow-up of 5 years. We also assessed the performance of the SYNTAX II score model in patients with and without diabetes. From the 3280 patients enrolled in the three trials, a total of 1068 (32.6%) had diabetes. The rate of the composite of death, myocardial infarction (MI), or stroke was similar in the PCI and CABG arms in patients with low-intermediate (≤32) SYNTAX scores (15.1% vs. 14.9%, respectively; P = 0.93) while it was significantly higher in the PCI arm in patients with high (≥33) SYNTAX scores (24.5% vs. 13.2%, respectively; P = 0.018). The SYNTAX score II showed good calibration and moderate discrimination ability in patients with diabetes (c-index = 0.68) as well as in those without (c-index = 0.67). CONCLUSIONS: Differences in 5 years outcomes following PCI and CABG for patients with MVD and diabetes were influenced by anatomic complexity as measured by the SYNTAX score. The SYNTAX score II mortality prediction model showed similar performance regardless of the diabetes status.


Subject(s)
Coronary Artery Bypass/mortality , Coronary Artery Disease/surgery , Diabetes Mellitus, Type 2/surgery , Diabetic Angiopathies/surgery , Percutaneous Coronary Intervention/mortality , Aged , Coronary Artery Disease/mortality , Coronary Artery Disease/pathology , Diabetes Mellitus, Type 2/mortality , Diabetes Mellitus, Type 2/pathology , Diabetic Angiopathies/mortality , Diabetic Angiopathies/pathology , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Postoperative Complications/etiology , Postoperative Complications/mortality , Pulmonary Disease, Chronic Obstructive/complications , Pulmonary Disease, Chronic Obstructive/mortality , Severity of Illness Index , Stroke/etiology , Stroke/mortality , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL